• Title/Summary/Keyword: Horizontal Pipe Flow

Search Result 93, Processing Time 0.026 seconds

Study on Pneumatic Transport for Pulverized coal Combustion (미분탄 연소를 위한 공기압 수송에 관한 연구)

  • Oh, C.S.;Choi, B.S.;Hong, S.S.;Hwang, K.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.4
    • /
    • pp.299-305
    • /
    • 1992
  • Saltation occurs in horizontal flow of solid and gas when the carrier gas velocity is small enough to permit enough to settling of the solid particles within the transport line. So we should examine the pneumatic flow system to lessen the unbured carbon in the power plant. In this paper the saltation velocity was studied on the various solid flow rate in the constant pipe diameter and on the various temperatures of the flow gas. The air velocity in the power plant transport lines was also surveyed in order to compare with the saltation velocity. As the solid flow rate increased in the constant diameter, saltation velocity increased and as the temperater of the flow gas inereased in the transport line, saltation velocity also increased.

  • PDF

Improved Convective Heat Transfer Correlations for Two-Phase Two-Component Pipe Flow

  • Kim, Dongwoo
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.403-422
    • /
    • 2002
  • In this study, six two-phase nonboiling heat transfer correlations obtained from the recommendations of our previous work were assessed. These correlations were modified using seven extensive sets of two-phase flow experimental data available from the literature, for vertical and horizontal tubes and different flow patterns and fluids. A total of 524 data points from five available experimental studies (which included the seven sets of data) were used for improvement of the six identified correlations. Based on the tabulated and graphical results of the comparisons between the predictions of the modified heat transfer correlations and the available experimental data, appropriate improved correlations for different flow patterns, tube orientations, and liquid-gas combinations were recommended.

Ice slurry transporting and branching characteristics for the district cooling (지역냉방을 위한 아이스슬러리 시스템의 수송 및 분기 특성)

  • Lee, Sang-Hoon;Yoo, Ho-Seon;Lee, Yoon-Pyo;Lee, Chang-Jun;Kwon, Hyeok-Min
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.662-667
    • /
    • 2009
  • The research are performed to check the characteristics of the ice slurry transport system for the district cooling. The system are installed at the 1st floored building which is as large as the $1204\;m^2$ ($86\;m{\times}14\;m$), and the pumping power and branching characteristics are measured by transporting of the ice slurry. The ice slurry transporting pipe is as long as 200 m. For the same cooling load, the higher IPF is, the lower the transporting flow rate and the pumping power are. But when the IPF is higher than 15%, no less decrease of the pumping power does happen. For the branching characteristics, through the branch pipe where the flow resistance is higher, the higher IPF is measured. A little higher IPF is measured at the thermal expansion branch.

  • PDF

An Effect of Heat Input on Thermal Storage for Horizontal Thermal Storage Tank with Heat pipe (열 파이프용 수평 축열조에서의 열 입력이 축열에 미치는 영향)

  • Pak, Ee-Tong;Jeong, Un-Chul
    • Solar Energy
    • /
    • v.16 no.2
    • /
    • pp.39-47
    • /
    • 1996
  • The horizontal thermal storage tank with heat pipe which is suitable for the sensible heat storage system is able to store a hot water from the heat source such as heating pad efficiently and to supply a hot water to load rapidly. And arrangement of heating pad play an important role in thermal flow and thermal storage efficiency. In this experiments, number of heating pad is ranged from three, five and nine, and when there is no change on number of heating pad, arrangements are two types of concentration-type and dispersion-type. Strong entrainment take place in the case of concentration-type of heating pad, and rapid temperature rise(${\Delta}{\doteqdot}1.6{\sim}3.2^{\circ}C$) in the tank is obtainable on the concentration-type than dispersion-type. In the constant number of heating pad, the concentration-type has the higher efficiency with about $5{\sim}6%$ than the dispersion-type Therefore, concentration-type of heating pad is an efficient design in constant number of heating pad.

  • PDF

Explicit Design of Uniformly-Rough Pipe on a Slope with Pumping Power (균일조도 동력경사관의 양해법 설계)

  • 유동훈;강찬수
    • Water for future
    • /
    • v.29 no.3
    • /
    • pp.163-176
    • /
    • 1996
  • When a pipe is deployed on a sloping bed, pumping power required for a discharge can be estimated immediately without any iteration process with an explicit form of a friction factor equation. Pumping power being given, however, traditional method requires an iteration process for the solution of discharge and pipe diameter even for the uniformly-rough pipe. You (1955b) has suggested explicit equations for the estimation of discharge and pipe diameter particularly for the cases of pipe on a slopintg bed without pumping and pipe on a horizontal bed with a pumping power. Based on his approach and previous results, the present researchers have developed explicit equations of discharge and pipe diameter for the general case of pipe on a sloping bed with a pumping power. The equations of boundary criteria are also presented in explicit way which render proper choice of various equations suitable for the flow condition between five characteristics. Verification studies are also carried out by applying the explicit equations to a practical example.

  • PDF

Condensation and evaporation heat transfer characteristics of HFC-134a in a horizontal smooth and a micro-finned tube (수평 평활관과 마이크로핀 관내에서 HFC-134a의 응축 및 증발열전달 특성)

  • Lee, Sang-Cheon;Park, Byeong-Deok;Han, Un-Hyeok;Lee, Jae-Hui
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.5
    • /
    • pp.1725-1734
    • /
    • 1996
  • Experimental condensation and evaporation heat transfer coefficients were measured in a horizontal smooth tube and a horizontal micro-finned tube with HFC-134a. The test sections are straight, horizontal tubes with have a 9.52mm outside diameter and about 5000mm long. The micro-finned tube had 60 fins with a height of 0.12mm and a spiral angle of 25.deg.. The condensation test section was a double-pipe type with counter flow configuration. The evaporation test section employed an electic heating method. Enhancement factors which is defined as a ratio of the heat transfer coefficient for micro-finned tube to that for smooth tube, varied from 1.3 to 1.6(mass flux:110~190kg/m$^{2}$s) for condensation and 1.2 to 1.5 (mass flux:70~160kg/m$^{2}$s) for evaporation. The experimental data of condensation and evaporation heat transfer coefficients were compared to several empirical correlations. Based on these comparisons, modified correlations of the condensation and evaporation heat transfer coefficient for both smooth and micro-finned tubes were proposed.

On the validation of ATHLET 3-D features for the simulation of multidimensional flows in horizontal geometries under single-phase subcooled conditions

  • Diaz-Pescador, E.;Schafer, F.;Kliem, S.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.9
    • /
    • pp.3567-3579
    • /
    • 2022
  • This paper provides an assessment of fluid transport and mixing processes inside the primary circuit of the test facility ROCOM through the numerical simulation of Test 2.1 with the system code ATHLET. The experiment represents an asymmetric injection of cold and non-borated water into the reactor coolant system (RCS) of a pressurized water reactor (PWR) to restore core cooling, an emergency procedure which may subsequently trigger a core re-criticality. The injection takes place at low velocity under single-phase subcooled conditions and presents a major challenge for the simulation in lumped parameter codes, due to multidimensional effects in horizontal piping and vessel arising from density gradients and gravity forces. Aiming at further validating ATHLET 3-D capabilities against horizontal geometries, the experiment conditions are applied to a ROCOM model, which includes a newly developed horizontal pipe object to enhance code prediction inside coolant loops. The obtained results show code strong simulation capabilities to represent multidimensional flows. Enhanced prediction is observed at the vessel inlet compared to traditional 1-D approach, whereas mixing overprediction from the descending denser plume is observed at the upper-half downcomer region, which leads to eventual deviations at the core inlet.

A Fundamental Study on Development of a Rotating Horizontal Heat Pipe (회전식 수평 Heat Pipe의 개발에 관한 기초 연구)

  • 임광빈;이진성
    • Journal of Energy Engineering
    • /
    • v.8 no.2
    • /
    • pp.325-332
    • /
    • 1999
  • When a rotating heat pipe is in operation, liquid condensate returns from the condenser to the evaporator along the inside surface by both components of gravitational and centrifugal forces. It was known that its performance was largely dependent on how to increase the flow rates of condensate and keep the condensate film thickness as thin as possible. Most of research works were focussed on this goal, and various inner wall structures such as tapered wall, stepped wall or coil inserted pipe etc. were developed. In the present study, a stepped wall structure with 3 internal grooves in the condenser and adiabatic zone was examined. For this system, the condensate would flow down to the evaporator through the grooves, resulting a reduced film thickness over the condenser surface. Experimental data showed an enhancement of heat transfer coefficient in the condenser zone. An analytical solution to the condensate film thickness showed that the analytically calculated values of heat transfer coefficient were considerably higher than the experimental data.

  • PDF

Hydraulic consideration to improve the tractive force of sewage in sewer pipes using a storage tank (관로내 하수흐름의 전단응력 향상을 위한 저수조의 활용에 관한 수리적 고찰)

  • Park, Kyoohong;Yu, Soonyu;Lee, Taehoon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.2
    • /
    • pp.121-129
    • /
    • 2019
  • If sewage flows for an extended time at low velocities, solids may be deposited in the sewer. Sufficient velocity or tractive force should be developed regularly to flush out any solids that may have been deposited during low flow periods. This study aims to evaluate the periods (T) during which sewage flow greater than the minimum tractive force maintains on a spot in sewer pipe system with lower tractive force or lower velocity than expected in the design step, when a storage tank installed in a place upsteam pours water into the sewer. The effect to T of design factors of storage tank and sewer pipes was evaluated assuming the uniform flow in sewers. When the area of orifice in the storage tank is $0.062m^2$(or 0.28 m diameter), the maximum T of 31sec was maintained using the usually used preset range of values of several design factors. As the horizontal cross section of storage tank and water depth of storage tank and roughness in sewers increase, T linearly increases. Also, T linearly decreases as the diameter of a sewer pipe increases. Although T gradually decreases as the sewer pipe slope decreases to around 0.005, T decreases sharply when the slope is less than 0.003.