• Title/Summary/Keyword: Horizontal Joint

Search Result 382, Processing Time 0.026 seconds

An Approach to Ergonomics Evaluation of Grip Strength - Case by the Manual Lifting - (악력의 인간공학적 평가를 위한 접근 방법 -들기 작업 자세의 경우-)

  • Yang, S.H.;Kal, W.M.;Park, P.
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.4
    • /
    • pp.209-213
    • /
    • 1997
  • Manual lifting techniques are commonly defined in terms of the postures adopted at the start of the lift. Quantitative definition is problematic, however, because the absolute joint angles adopted to lift an object are influenced by task parameters, such as the initial height of the load. The main objective of this study is to investigate the grip strength of the both hands at the initial lifting points. The survey is conducted by measuring the compression force, anthropometric data and grip strength at the lifting postures for the subjects(n=50) who is assigned to their job as usual. The experiment is peformed at the four lifting postures which involving the combination of two horizontal factors(H1 : 35 cm, H2 : 55 cm) and two vertical factors(V1 : 20~80 cm, V2 : 47~102 cm). The analysis result of lifting posture indicated that each H1-V1, H2-V1 combinations are about 60$^{\circ}$ and each H1-V2, H2-V2 combinations are about $30^{\circ}$. There are significant differences on grip strength between $60^{\circ}$ and $30^{\circ}$ stooped posture. The results of this study can be provided a method defining lifting postures at the minimum grip strength. Also, it is eliminated a hazard of the injuries which are cumulative trauma disorders(CTDs) and back pain, increased a productivity and improved a welfare of workers.

  • PDF

Mechanical performance of a new I-section weak-axis column bending connection

  • Lu, Linfeng;Xu, Yinglu;Lim, James B.P.
    • Steel and Composite Structures
    • /
    • v.26 no.1
    • /
    • pp.31-44
    • /
    • 2018
  • This paper reports a novel steel beam-to-column connection suitable for use in the weak axis of I-section column. Monotonic and cyclic loading experimental investigations and numerical analysis of the proposed weak-axis connection were conducted, and the calculation procedure of the beam-column relative rotation angle and plastic rotation angle was developed and described in details. A comparative analysis of mechanical property and steel consumption were employed for the proposed I-section column weak-axis connection and box-section column bending connection. The result showed that no signs of fracturing were observed and the plastic hinge formed reliably in the beam section away from the skin plate under the beam end monotonic loading, and the plastic hinge formed much closer to the skin plate under the beam end cyclic loading. The fracture of welds between diaphragm and skin plate would cause an unstable hysteretic response under the column top horizontal cyclic loading. The proposed weak-axis connection system could not only simplify the design calculation progress when I-section column is adopted in frame structural design but also effectively satisfy the requirements of 'strong joint and weak member', as well as lower steel consumption.

Discoid Medial Meniscus in the Knee - A case report - (슬관절 내측 원판형 연골 - 1례 보고 -)

  • Kyung, Hee-Soo;Kim, Kyung-Hoon;Oh, Chang-Wug
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.1
    • /
    • pp.58-62
    • /
    • 2009
  • A discoid medial meniscus is a relatively rare pathology of the knee joint, and we recently encountered a patient with discoid medial meniscus, and this report is a case of therapeutic experience in this patient. The patient was twenty years old man who had a persistent dull pain for several years without specific trauma history. He was presumptively diagnosed as discoid medial meniscus by MRI, and arthroscopic examination confirmed the presence of the complete type of discoid medial meniscus with horizontal tear. We performed arthroscopic partial meniscectomy, and the patient could get free from symptom.

  • PDF

Effectiveness of some conventional seismic retrofitting techniques for bare and infilled R/C frames

  • Kakaletsis, D.J.;David, K.N.;Karayannis, C.G.
    • Structural Engineering and Mechanics
    • /
    • v.39 no.4
    • /
    • pp.499-520
    • /
    • 2011
  • The effectiveness of a technique for the repair of reinforced concrete members in combination with a technique for the repair of masonry walls of infilled frames, damaged due to cyclic loading, is experimentally investigated. Three single - story, one - bay, 1/3 - scale frame specimens are tested under cyclic horizontal loading, up to a drift level of 4%. One bare frame and two infilled frames with weak and strong infills, respectively, have been tasted. Specimens have spirals as shear reinforcement. The applied repair technique is mainly based on the use of thin epoxy resin infused under pressure into the crack system of the damaged RC joint bodies, the use of a polymer modified cement mortar with or without a fiberglass reinforcing mesh for the damaged infill masonry walls and the use of CFRP plates to the surfaces of the damaged structural RC members, as external reinforcement. Specimens after repair, were retested in the same way. Conclusions concerning the effectiveness of the applied repair technique, based on maximum cycles load, loading stiffness, and hysteretic energy absorption capabilities of the tested specimens, are drawn and commented upon.

A Test on the Aseismic Capacity of a Traditional Three-bay-straw-roof House(I) : Rock Site Condition (전통 초가삼간 가옥의 내진성능 평가 실험(I) : 암반지반 조건)

  • 서정문;최인길;전영선;이종림;신재철
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.1 no.4
    • /
    • pp.11-20
    • /
    • 1997
  • The aseismic capacity of a traditional three-bay-straw-roof wooden house for rock site condition is quantitatively estimated. One 1/4 scale model was tested for the Nahanni Earthquake with peak ground accelerations from 0.1g to 0.6g. The natural frequency of the wooden house in elastic range is 1.66 Hz and 2.15 Hz in longitudinal and transversal direction, respectively. Damping ratio of the house in elastic range is 7%. The horizontal acceleration response of the house is significantly reduced compared with the input motion due to the nonlinear inelastic characteristics of the Sagae-machum joint of the frame. The traditional wooden house has high aseismic capacity in the rock site condition where high frequency contents of motion are predominant.

  • PDF

A Study on Stable Grasping Control of Dual-fingers with Soft-Tips (소프트-팁이 장착된 듀얼-핑거의 안정적 파지 제어에 관한 연구)

  • 심재군;한형용;양순용;이병룡;안경관;김성수
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.219-224
    • /
    • 2002
  • This paper aims to derive a mathematical model of the dynamics of handling tasks in robot finger which stable grasping and manipulates a rigid object with some dexterity. Firstly, a set of differential equation describing dynamics of the manipulators and object together with geometric constraint of tight area-contacts is formulated by Lagrange's equation. Secondly, problems of controlling both the internal force and the rotation angle of the grasped object under the constraints of area-contacts of tight area-contacts are discussed. The effect of geometric constraints of area-contacts on motion of the overall system is analyzed and a method of computer simulation for overall system of differential-algebraic equations is presented. Thirdly, simulation results are shown and the effects of geometric constraints of area-contact is discussed. Finally, it is shown that even in the simplest case of dual single D.O.F manipulators there exists a sensory feedback from sensing data of the rotational angle of the object to command inputs to joint actuators and this feedback connection from sensing to action eventually realizes secure grasping of the object, provided that the object is of rectangular shape and motion is confined to a horizontal plane.

  • PDF

Seismic reflection imaging ahead of tunnel face using 3 component geophones (3성분 지오폰을 이용한 막장전방 예측 탄성파탐사)

  • Jo Churl Hyun;Cha Young Ho;Yang Jong Hwa;Bang Ki Moon
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.412-417
    • /
    • 2005
  • To ensure the safety of the tunnelling without the loss of economy, the tunnel seismic profiling(TSP) method for the prediction ahead of tunnel face, begins to be used routinely in these days. TSP method does not interfere the tunnelling works while the horizontal drilling does, and its prediction length is longer than that of the drilling. Yet the most frequently adopted technique of TSP in Korea is the multi-shot and 2 receiver array using in-hole receivers, even though this array requires as many as 26 drill-holes for receiver installation and ballasting, which results in 3-6 hours of suspension in excavation work. In this paper, multi-receiver and lesser shot array using side-wall attached 3 component geophones is to be described to prove the efficiency in terms of the survey time as well as the reliability of the method by comparison of the predicted weak points and the face mapping results. The predictions mostly agreed with the real fractures or joint developed zones which have been confirmed during the excavation. It also has been found that TSP method can be effectively applied to perform draining ground water ahead of tunnel face by imaging the geologic discontinuities.

  • PDF

Study on the Piezoelectric Bender Actuator for Small Walking Robots

  • Park, Min Ho;Park, Jong Man;Song, Chi Hoon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.4
    • /
    • pp.276-280
    • /
    • 2020
  • A linear piezoelectric actuator that utilizes the elliptical motion of the two tips of the actuator is proposed. This device is easy to fabricate owing to its simple structure, consisting of three piezo ceramic benders and is suitable for use in micro robotic applications. A π-shaped structure, which was composed of four piezo ceramic benders, was constructed. Two of the benders were positioned on the center of the actuator, and the joints were attached at the ends of the cantilever. The other two benders were positioned on the side of the actuator and were attached between the joint and the tips. The actuator structure was designed to obtain the first bending mode of the horizontal vibration and the vertical vibration at the same frequency, resulting in elliptical motions at the tips. When two sinusoidal wave voltages with a 90-degree phase difference were applied to the two pairs of the actuator benders, elliptical motions were obtained at the tips. The driving characteristics of the prototype actuator were then measured using a laser doppler vibrometer.

Cyclic behavior of steel beam-concrete wall connections with embedded steel columns (I): Experimental study

  • Li, Guo-Qiang;Gu, Fulin;Jiang, Jian;Sun, Feifei
    • Steel and Composite Structures
    • /
    • v.23 no.4
    • /
    • pp.399-408
    • /
    • 2017
  • This paper experimentally studies the cyclic behavior of hybrid connections between steel coupling beams and concrete shear walls with embedded steel columns. Four beam-to-wall connection specimens with short and long embedded steel columns are tested under monotonic and cyclic loads, respectively. The influence of embedment length of columns on the failure mode and performance of connections is investigated. The results show that the length of embedded steel columns has significant effect on the failure mode of connections. A connection with a long embedded column has a better stiffness, load-bearing capacity and ductility than that of a short embedded column. The former fails due to the shear yielding of column web in the joint panel, while failure of the latter is initiated by the yielding of horizontal reinforcement in the wall due to the rigid rotation of the column. It is recommended that embedded steel columns should be placed along the entire height of shear walls to facilitate construction and enhance the ductility.

Retrofitting of squat masonry walls by FRP grids bonded by cement-based mortar

  • Popa, Viorel;Pascu, Radu;Papurcu, Andrei;Albota, Emil
    • Earthquakes and Structures
    • /
    • v.10 no.1
    • /
    • pp.125-139
    • /
    • 2016
  • For seismic retrofitting of masonry walls, the use of fibre reinforced cement-based mortar for bonding the fibre grids can eliminate some of the shortcomings related to the use of resin as bonding material. The results of an experimental testing program on masonry walls retrofitted with fibre reinforced mortar and fibre grids are presented in this paper. Seven squat masonry walls were tested under unidirectional lateral displacement reversals and constant axial load. Steel anchors were used to increase the effectiveness of the bond between the fibre grids and the masonry walls. Application of fibre grids on both lateral faces of the walls effectively improved the hysteretic behaviour and specimens could be loaded until slip occurred in the horizontal joint between the masonry and the bottom concrete stub. Application of the fibre grids on a single face did not effectively improve the hysteretic behaviour. Retrofitting with fibre reinforced mortar only prevented the early damage but did not effectively increase deformation capacity. When the boundaries of the cross sections were not properly confined, midplane splitting of the masonry walls occurred. Steel anchors embedded in the walls in the corners area effectively prevented this type of failure.