• Title/Summary/Keyword: Horizontal Design

Search Result 2,048, Processing Time 0.034 seconds

Optical Configurations for an Achromatic Transflective Liquid Crystal Cell

  • Lee, Gak-Seok;Kim, Jae-Chang;Yoon, Tae-Hoon;Kim, Young-Sik;Kang, Tae-Hoon;Kang, In-Byeong
    • Journal of Information Display
    • /
    • v.7 no.1
    • /
    • pp.19-24
    • /
    • 2006
  • We propose optical configurations of a double-cellgap liquid crystal cell for transflective displays with wide viewing angle and high contrast ratio. The reflective part is designed in the wide-band quarter wave structure to achieve good dark state. For the transmissive part, the compensation method is applied to achieve the super-achromatic dark state, and three switching methods are used : which are vertical switching, horizontal switching to $30^{\circ}$and horizontal switching to $120^{\circ}$, to achieve the bright state.

Introduction to Archimedean Horizontal Stars on Geometric Tube Design (기하학적 튜브디자인과 아르키메데스 수평별 입문)

  • Hwang, Hongtaek
    • Communications of Mathematical Education
    • /
    • v.29 no.2
    • /
    • pp.241-254
    • /
    • 2015
  • We have announced a series of Archimedean stars on the mathematical art galleries of Bridges conference since 2012. We are developing a systematic approach and methodology about the composition process of Archimedean stars on geometric tube design. We will introduce the various information about the Archimedean horizontal stars under certain introductory level as well as the underlying information of Archimedean stars to provide them as useful sources for certain creative experimental mathematics education.

Evaluation of Conventional Prediction Model for Soil Thermal Conductivity to Design Horizontal Ground Heat Exchanger (수평형 지중열교환기 설계를 위한 토양 열전도도 예측 모델 평가)

  • Sohn, Byong-Hu;Wi, Ji-Hae;Han, Eun-Seon;Lim, Jee-Hee;Choi, Hang-Seok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.813-824
    • /
    • 2010
  • Thermal conductivity of soils is one of the most important parameters to design horizontal ground heat exchangers. It is well known that the thermal conductivity of soil is strongly influenced by its density and water content because of soil's particulate structure. This paper reviewed and evaluated some of the commonly used prediction models for thermal conductivity of soils with the experimental data available in the literature. Semi-theoretical models for two-component materials were found inappropriate to estimate the thermal conductivity of dry state sands. It came out that the model developed by Cote and Konrad gave the best overall prediction for unsaturated sands available in the literature. Also, a parametric analysis is conducted to investigate the effect of thermal conductivity and water content, soil type on the horizontal ground heat exchanger design. The analysis shows that a required pipe length for the horizontal ground heat exchanger is reduced with the increase of soil thermal conductivity and water content. The calculation results also show that the dimension of the horizontal ground heat exchanger can be reduced to a certain extent by using backfilling material with a higher thermal conductivity of solid particles.

  • PDF

Evaluation of Design Method and Shear Transfer Capacity on the Horizontal Interface of PC Composite Beams (PC 합성보의 수평접합면 전단력 전달성능 평가 및 설계법 분석)

  • Moon, Jeong-Ho;Oh, Young-Hun
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.1
    • /
    • pp.81-90
    • /
    • 2013
  • The purpose of this study is to evaluate the horizontal shear strength on the interface between PC and cast-in-place concrete for PC composite beams. Six specimens were tested to examine the structural performance of the horizontal interface with different surface condition and stirrup detailing. Except for SF-291B specimen failed in flexural compression, strengths and deformation capacities of five specimens were determined by horizontal shear failure. Horizontal shear strengths by composite horizontal shear or shear friction in current codes could be used to predict the horizontal shear capacity of the interface for specimens. Also detailing for stirrup by PCI design provision could be used to accomplish the composite action in the interface.

Efficiency of CFT column plastic design approach for frame structures subjected to horizontal forces

  • SeongHun Kim;Hyo-Gyoung Kwak
    • Computers and Concrete
    • /
    • v.32 no.5
    • /
    • pp.527-541
    • /
    • 2023
  • This paper emphasizes the use of CFT columns in frame structures subjected to strong horizontal forces and shows that the efficiency of using CFT columns is increased when the plastic design approach is adopted. Because the plastic design approach is based on redistribution of the force of the internal member, a double node for the rotational degrees of freedom, where the adjacent two rotational degrees of freedom can be connected by a non-dimensional spring element, is designed and implemented into the formulation. In addition, an accompanying criterion is considered in order to make it possible to describe the continuous moment redistribution in members connected to a nodal point up to a complete plastic state. The efficiency of CFT columns is reviewed in comparison with RC columns in terms of the cost and the resistance capacity, as defined by a P-M interaction diagram. Three representative frame structures are considered and the obtained results show that the most efficient and economical design can be expected when the use of CFT columns is considered on the basis of the plastic design, especially when a frame structure is subjected to significant horizontal forces, as in a high-rise building.

Interface Horizontal Shear Strength between UHPC Deck and Concrete Girder with Stirrups (스터럽을 이용한 UHPC 바닥판과 콘크리트 거더 연결부의 수평전단강도)

  • Yoo, Dong-Min;Hwang, Hoon-Hee;Kim, Sung-Tae;Park, Sung-Yong
    • Composites Research
    • /
    • v.25 no.5
    • /
    • pp.164-168
    • /
    • 2012
  • The purpose of this experimental research was to evaluate interface shear requirements between UHPC deck and concrete girder with stirrups according to Korean Highway Bridge Design Code and AASHTO LRFD Bridge Design Specifications. The push-out tests are performed to analize the composite behavior in interface of connection. The test results were compared to the values of interface horizontal shear strength predicted by current codes. As the results, it was observed that the test results provided more conservative estimate for horizontal shear strength than the values by current codes equation.

Horizontal Active Thrusts and Design of GRS-RW System for Distanced Surcharge (상재하중 이격거리를 고려한 GRS-RW 공법의 토압해석 및 설계)

  • 방윤경
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.1
    • /
    • pp.15-29
    • /
    • 1999
  • This study presents an analytical method of estimating the developed horizontal active thrusts against GRS-RW( Geosynthetic Reinforced Soil Retaining Wall) system adapted to the case of distanced surcharge. In addition, the design charts that could be used for preliminary design of GRS-RW system are presented. The proposed method of analysis uses two body translation mechanism as well as force polygon concept. taking into account the effect of facing's rigidity. Besides. the effect of tension cracks in c-\Phi$ soils, seismic effects and horizontal distance from the back face of wall to uniformly distributed surcharge loadings are also included. The results of horizontal active thrusts obtained from the developed method of analysis are compared with those from Jarquio's modified Boussinesq equation.

  • PDF

Performance Analysis of High Efficiency Horizontal Axis Tidal Current Turbine (고효율 수평축 조류발전 터빈의 성능해석)

  • Kim, Ki-Pyoung;Kim, Jung-Min;Kim, Beom-Seok;Lee, Young-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.632-635
    • /
    • 2009
  • Nowadays renewable energy has undergone major development, however most renewable energy resources still have demerit which is under the influence of environmental factors that can not be set up the power plants or can not be generated the rated power. To wander from the point of environmental instability, the present paper looks at the tidal current energy which can supply regular electric power. It has an important merit which is more predictable than others, however the place which can be set up is limited and the turbine system must be optimized. The development of the optimized rotor blades design is urgent to obtain regular electric power using the tidal current energy. Therefore, the paper expands on this idea and presents a conceptual design of 100kW horizontal axis rotor blade for the tidal current turbine using blade element momentum (BEM) analysis. The compatibility of horizontal axis tidal turbine (HATT) is verified using a commercial computational fluid dynamics (CFD) code, ANSYS-CFX. This paper presents results of the numerical analysis, such as pressure, streak line and the performance curves with torque data for the inflow of the horizontal axis tidal current turbine (HATT).

  • PDF

Effect of Soil Thermal Conductivity and Moisture Content on Design Length of Horizontal Ground Heat Exchanger (토양 열전도도와 수분함량이 수평형 지중열교환기 설계 길이에 미치는 영향)

  • Sohn, Byong-Hu
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.1
    • /
    • pp.21-31
    • /
    • 2012
  • This paper reviewed and evaluated some of the commonly used prediction models for thermal conductivity of soils with the experimental data. Semi-theoretical models for two-component materials were found inappropriate to estimate the thermal conductivity of dry state soils. It came out that the model developed by Cote and Konrad gave the best overall prediction results for unsaturated soils available in the literature. However, it still needs to be improved to cover a wider range of soil types and degrees of saturation. In the present study, parametric analysis is also conducted to investigate the effect of soil type and moisture content on the horizontal ground heat exchanger design. The analysis shows that horizontal ground heat exchanger pipe length is reduced with the increase of soil thermal conductivity and water content. The calculation results also show that horizontal ground heat exchanger size can be reduced to a certain extent by using backfilling material with a higher thermal conductivity of solid particles.

Effect of Vanes on Flow Distribution in a Diffuser Type Recuperator Header (디퓨저 타입 레큐퍼레이터 헤더에서 유동분배에 미치는 베인의 영향)

  • Jeong Young-Jun;Kim Seo-Young;Kim Kwang-Ho;Kwak Jae-Su;Kang Byung-Ha
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.10
    • /
    • pp.819-825
    • /
    • 2006
  • In a SOFC/GT (solid oxide fuel cell/gas turbine) hybrid power generation system, the recuperator is an indispensible component to enhance system performance. Since the expansion ratio to the recuperator core is very large, generally, the effective header design to distribute the flow uniformly before entering the core is crucial to guarantee the required performance. In the present study, we focus on the design of a diffuser type recuperator header with a 90 degree turn inlet port. To reduce the flow separation and recirculation flows, multiple horizontal vanes are used. The number of horizontal vanes is varied from 0 to 24. The air flow velocity is measured at 40 points just behind the core outlet by using a hot wire anemometer. Then, the flow non-uniformity is evaluated from the measured flow velocity. The experimental results showed that inlet air velocity did not effect on relative flow non-uniformity. According to increasing the number of horizontal vanes, flow non-uniformity reduced about $40{\sim}50%$ than without using horizontal vanes.