• Title/Summary/Keyword: Hook

Search Result 681, Processing Time 0.026 seconds

Spontaneous Healing of Acromial Stress Fracture Caused by Clavicle Hook Plate in Acromioclavicular Joint Dislocation - A Case Report

  • Kim, Gang-Un;Kim, Seong-Hwan;Lee, Jae-Sung;Kim, Jae Yoon
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.1
    • /
    • pp.36-39
    • /
    • 2014
  • Clavicular hook plate is known to be an effective treatment on acromioclavicular (AC) joint injury, but there have been some reports of complications, like osteolysis and bony erosion of the undersurface of acromion. Fifty-five year old male underwent open reduction and hook plate insertion on Rockwood type 5 acromioclavicular joint dislocation. He complained of protrusion of posterior acromion at 1 month after the surgery, and acromial fracture was noted in simple radiographs. The hook plate was removed and any other treatment for osteosynthesis was refused by the patient. At the 18 months after the surgery, the patient had no pain and a full range of motion with no tenderness around the shoulder joint. After two years, plain radiographs revealed complete bony union of the acromion fracture.

Development of a Hook-type Finger Force Measuring System with Force Sensors (힘센서를 이용한 후크형 손가락 힘 측정 장치 개발)

  • Kim, Gab-Soon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.6
    • /
    • pp.663-668
    • /
    • 2014
  • This paper presents a hook-type finger force measuring system with force sensors. The system is composed of a body, two three-axis force sensors, a hook, and so on. The two three-axis force sensors system was specially designed using FEM(Finite Element Method) and fabricated using strain-gages. The sensors measure the finger forces of both normal people and handicapped people in the system, and the forces are combined. The developed hook-type finger force measuring system can measure the pulling finger force of both normal and handicapped people. The pulling force tests of men and women were performed using the developed the system. It is thought that the developed system can be used to measure the pulling force of fingers.

A Study on the Performance of Car Active Suspension System by the output Feedback and Sky-hook Control Method (출력귀환과 스카이 훅 제어 방식에 의한 차량 현가 장치의 성능에 관한 연구)

  • 김재열
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.5 no.4
    • /
    • pp.7-16
    • /
    • 1996
  • The dynamic model of the suspension system is developed by using both sky-hook control and output feedback control techniques. based on the performance sensitivity index, Many vehicles use sky-hook control theory operated with only one sensor, due to relatively low cost and easy implementation. On the other hand, output feedback control implemented with state variables has difficulties in measuring such as tire deflection, etc.

  • PDF

Crossbar Technique for the Failed Clavicular Hook Plate Fixation in an Acute Acromioclavicular Joint Dislocation: Salvage for Acromial Fracture after Clavicular Hook Plate

  • Koh, Kyoung Hwan;Shin, Dong Ju;Hwang, Seong Mun
    • Clinics in Shoulder and Elbow
    • /
    • v.22 no.3
    • /
    • pp.149-153
    • /
    • 2019
  • We experienced acromial erosion and subsequent fracture after the treatment of Rockwood type V acromioclavicular dislocation with hook plate and coracoclavicular ligament augmentation. It was treated by using a surgical technique to address an acromial fracture and subsequent losses of reduction in acromioclavicular joint with two trans-acromial cortical screws (crossbar technique). The reduction state of acromioclavicular joint could be maintained by these two screws. Our crossbar technique could be considered as a good salvage procedure for the reduction loss caused by cutout or significant erosion of acromion after insertion of clavicular hook plate.

Comparative Evaluation of Sky-Hook Controllers for a Full Car Model with Active or Semi-Active Suspension Systems (능동과 반능동 현가장치로 된 전차량 모델에 대한 스카이훅 제어기의 비교 평가)

  • Yun, Il-Jung;Im, Jae-Pil
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.7 no.7
    • /
    • pp.614-621
    • /
    • 2001
  • The controllers for a full car 7-DOF model with 4 active or semi-active suspension units are designed and evaluated in this research. The control algorithms for suspension systems, such as full state feedback active, full state feedback semi-active, sky-hook active, sky-hook semi-actvie, and on-off suspension systems, are analyzed and evaluated with respect to ride comfort. The vehicle dynamic performances are expressed by response curves to a bump input, performance indices for asphalt road input, and frequency characteristic curves. Heaving, rolling, and pitching inputs are applied to the vehicle dynamic system to evaluate frequency characteristics. The simulation results show that the ride quality of the sky-hook controller approaches that the full state feedback controller more closely in semi-active suspension system than in active suspension system. For the implementation of a vehicle with sky-hook suspension control systems in this paper, 7 velocity sensors are required to measure the states.

  • PDF

Magnetic Field Simulation and Analysis for Monitoring Safety Hook Fastening (안전고리 체결 감지를 위한 자기장 시뮬레이션 및 분석)

  • Lee, Hoo-Sung;Heo, Jun;Park, Yong-Bae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.6
    • /
    • pp.1169-1174
    • /
    • 2020
  • In this paper, in order to prevent a fall accident that occurs while working without fastening the safety hook at a construction site, a method to detect whether the safety hook is fastened using two coils is proposed. Ansys' Maxwell, an electromagnetic wave analysis simulator, was used to analyze the magnetic field before and after the safety hook fastening, and the possibility of confirming the fastening of the safety hook using the difference in the mutual inductance change and the resulting current induced in the receiving coil was shown.

Treatment of Acromioclavicular Joint Injuries Using Clavicle Hook Plates (Clavicle Hook Plate를 이용한 견봉 쇄골 관절 손상의 치료)

  • Kim, Myung-Ho;Seo, Joong-Bae;Moon, Sang-Young
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.92-98
    • /
    • 2010
  • Purpose: To analyze results of treating acromioclavicular injuries using clavicle hook plates. Materials and Methods: Between February 2008 and April 2010, 18 patients with acromioclavicular joint injury treated by clavicle hook plates were reviewed. Using the Rockwood classification, 7 dislocations were classified as type III injuries and 11 as type V injuries. Implant removal was done at least 3 months from initial fixation. Simple X-rays were taken for comparing the state of reduction, and clinical outcomes were evaluated by the Korean Shoulder Scoring System and the American Shoulder Elbow Society score. The average follow-up period was 9 months. Results: On weight bearing X-rays, the average coracoclavicular distance showed a 114% increase compared to the contralateral side at the time of injury. It decreased to 23% by the last follow-up. The mean Korean Shoulder Scoring System and the American Shoulder Elbow Society score were 80 and 74 at the last follow-up. Conclusion: The immediate stability these plates provide allows rapid rehabilitation. Clavicle hook plate fixation for acromioclavicular joint dislocation is considered an effective method for ensuring satisfactory results both radiologically and clinically.

Effects of Hook and Bait Types on Bigeye Tuna Catch Rates in the Tuna Longline Fishery (다랑어 연승어업에서 눈다랑어 어획률에 미치는 낚시 및 미끼의 효과)

  • Kim, Soon-Song;Moon, Dae-Yeon;An, Doo-Hae;Hwang, Seon-Jae;Kim, Yeong-Seung;Bigelow, Keith;Curran, Daniel
    • Korean Journal of Ichthyology
    • /
    • v.20 no.2
    • /
    • pp.105-111
    • /
    • 2008
  • A pelagic tuna longline research cruise in the eastern and central Pacific Ocean from September to October of 2006 was conducted to compare catch rates with the use of different hook type and bait combinations. Traditional tuna hooks (J 4) and three circle hook types (C15, C16, C18), along with five bait types (chub mackerel (CM), jack mackerel (JM), milkfish (MF), sardine (SD), and squid (SQ)) and hook number as a proxy for hook depth were evaluated for their effect on bigeye tuna catch rates (fish per 1,000 hooks) using Generalized Linear Models (GLMs). Results from 28 sets indicated significant differences in bigeye catch rates between individual longline sets and hook number. The GLM explained 33% of the deviance in bigeye catch rates with these two factors. An alternative model formulation included bait type which had a small effect (explaining 2.7% of the deviance) on catch rates. Hook type had a negligible and non-significant effect in the GLMs. These results indicate that all of the hooks and baits tested are equally effective at catching bigeye tuna and that hook number (depth) was the paramount operational factor in explaining bigeye tuna catch rates.

A ROENTGENOGRAPHIC STUDY OF THE APPEARANCE ON THE HOOK OF THE HAMATE (유구골구의 출현에 관한 방사선학적 연구)

  • Lee, Seong Bok
    • The korean journal of orthodontics
    • /
    • v.7 no.1
    • /
    • pp.13-22
    • /
    • 1977
  • The author investigated the timing of land and wrist ossification events taking place in the hamate and pisiform by means of roentgenographic examination and its relation to the peak growth velocities in body height. Materials obtained included 493 sheets of X-ray films taken from 257 boys ana 236 girls aged between 7 and 17 years lived in Seoul area. The results indicate that; 1) The average ages at occurrence of initial ossification of the hook of the hamate were 12 years 3 months in boys and 10 years 1 month in girls. 2) The average ages at which advanced ossification of the hook of the hamate occurred were 13 years 7 months in boys and 11 years 11 months in girls. 3) Initial ossification of the pisiform appeared at 13 years 0 month in boys and 10 years 2 months in girls. 4) All three ossification events in hand and wrist, and peak growth velocity in body height occurred earlier in girls than in boys. 5) Initial ossification in the hook of the hamate and pisiform preceded or coincided with peak growth in body height in most boys and girls, on the other hand, advanced ossification in the hook of the hamate occurred around peak growth in body height but in girls did it after peak growth in body height. 6) It would appear that initial ossification in the hook of the hamate or in the pisiform, both for boys and girls, provides a better indication of approaching peak adolescent growth in body height. 7) Advanced ossification in the hook of the tamale would indicate that the period of cercumpuberal peak growth had teen entered or finished.

  • PDF

Position Change of the Neurovascular Structures around the Carpal Tunnel with Dynamic Wrist Motion

  • Kwon, Jae-Yoel;Kim, Ji-Young;Hong, Jae-Taek;Sung, Jae-Hoon;Son, Byung-Chul;Lee, Sang-Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.4
    • /
    • pp.377-380
    • /
    • 2011
  • Objective : The purpose of this study was to determine the anatomic relationships between neurovascular structures and the transverse carpal ligament so as to avoid complications during endoscopic carpal tunnel surgery. Methods : Twenty-eight patients (age range, 35-69 years) with carpal tunnel syndrome were entered into the study. We examined through wrist magnetic resonance imaging in three different positions (neutral, radial flexion, and ulnar flexion) and determined several anatomic landmark (distance from the hamate hook to the median nerve, ulnar nerve, and ulnar vessel) based on the lateral margin of the hook of the hamate. The median nerve and ulnar neurovascular structure were studied with the wrist in the neutral, ulnar, and radial flexion positions. Results : The ulnar neurovascular structures usually passed just over or ulnar to the hook of the hamate. However, in 12 hands, a looped ulnar artery coursed 0.6-3.3 mm radial to the hook of the hamate and continued to the superficial palmar arch. The looped ulnar artery migrates on the ulnar side of Guyon's canal (-5.2-1.8 mm radial to the hook of the hamate) with the wrist in radial flexion. During ulnar flexion of the wrist, the ulnar artery shifts more radially beyond the hook of the hamate (-2.5-5.7 mm). Conclusion : It is appropriate to transect the ligament greater than 4 mm apart from the lateral margin of the hook of the hamate without placing the edge of the scalpel toward the ulnar side. We would also recommend not transecting the transverse carpal ligament in the ulnar flexed wrist position to protect the ulnar neurovascular structure.