• Title/Summary/Keyword: Home-healthcare

Search Result 353, Processing Time 0.03 seconds

A Study on Research Framework and Research Trends in the Healthcare Information Technology Area (헬스케어 정보기술 분야의 연구 프레임워크 및 연구동향)

  • Lee, N.K.;Lee, J.O.;Hwang, K.T.
    • Informatization Policy
    • /
    • v.21 no.3
    • /
    • pp.3-32
    • /
    • 2014
  • Recent developments of smart phone and ICT, and explosive developments of wireless sensor area drive radical changes on traditional health care service. To accommodate the changes, many researchers have studied to expand traditional healthcare service areas including home care for independent living and public care for preventive and collaborative wellness area. This study proposes a research framework for healthcare information technology area based on Mettler and Raptis's(2012) work. Then, the study analyze the research trends in the area based on the framework. The area of monitoring patients health status at home using smart phone, providing innovative healthcare service by out-patients monitoring, and implementing preventive healthcare services are identified most active and emerging research agenda. It is expected that the research framework and implications of this study can assist future research efforts and practical utilization of healthcare information technologies.

A Design and Implementation of Mobile Healthcare System based on Smart Gateway (스마트 게이트웨이 기반 모바일 헬스케어시스템의 설계 및 구현)

  • Kang, Sung-In;Oh, Am-Suk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.9
    • /
    • pp.1970-1976
    • /
    • 2012
  • Home healthcare system has lot of things to do for the integration with medical instruments in the sense of standardization. We will design and implement mobile healthcare system based on smart gateway thru adaptation of ISO/IEEE 11073, and HL7 standard. And also we are willing to research heart rate monitor, pulse-oxygen meter and ECG monitor in order to develop mobile healthcare system for medical appliance. We studied the connection of standard medical devices, i.e, continua health alliance under the Android 4.x Bluetooth HDP(Health Device Profile) environments. We also tried to implement healthcare system which can support diagnosis for healthcare provider and user based on HL7 standard.

A Development of Home Nursing Service System based Service Oriented Architecture (SOA) (SOA 기반의 가정간호서비스 시스템 개발)

  • Hong, Hae-Sook;Park, Chun-Bok;Kim, Hwa-Sun;Cho, Hun
    • Journal of Korea Multimedia Society
    • /
    • v.12 no.11
    • /
    • pp.1680-1691
    • /
    • 2009
  • To improve the quality of healthcare and build up the health delivery system, electronic health record system is important for healthcare institutions providing health services. However, the systems currently operated in domestic healthcare institutions use independent software interface with distributed environment for data search and process. Therefore, it raises an additional expense to buy or develop each interface module when there is a link to new system and the problem of complexity. To solve these problems, this study implemented the service oriented architecture basis for home nursing service and carried out an assessment. The study defined the process modeling and business requirements based on the scenario of service and drew 17 suitable services based on five verification items for service design. To draw the final service, seven services were selected by service litmus test (SLT). The study found that, by the improvement of business process for healthcare service support department, SOA based information system has an effect of time reduction of patient processing time. In conclusion, to enable the hospital information system to cope with various demands of healthcare consumers, it is necessary to consider the application of SOA technology which has excellent interoperability, reusability and maintenance.

  • PDF

Critical Pathway of Home Healthcare for COPD clients (COPD 대상자의 가정간호를 위한 Critical pathway)

  • Cho, Won-Jung;Han, Mi-Kyung
    • Research in Community and Public Health Nursing
    • /
    • v.12 no.2
    • /
    • pp.329-337
    • /
    • 2001
  • Purpose: This study was to develop a critical pathway for COPD clients in home health care. Method: Review of literature. Analysis of 10 cases of home health records of COPD clients without other major chronic illness, and Contents validity test Results 1. Vertical axis(l4 activities) physical and mental assessment, family assessment. environment assessment, rights and duties of client, oxygen use and safety, education of disease process and symptom, medication, nutrition and elimination, tests, activities, respiratory exercise, sleeping pattern. consultations and discharge planning. 2. Horizontal axis was set by the number of visits(average number of visits is 6.4) and vertical axis was set with 14 activities and the contents which should have occurred, according to the time frames of the horizontal axis. 3. According to the contents validity test, among the total of 234 items, 176 items showed over 83% agreement and 58 items showed less than 83% agreement. Those items with less than 83% agreements were either deleted or revised. Conclusion this critical pathway is applicable to the home health care of COPD clients to provide quality home nursing care services at lower cost.

  • PDF

A Study on the End-Of-Life Care and Healthcare Costs in Japan (일본의 말기의료와 경제적 비용에 관한 연구)

  • Oh, Eun-Hwan
    • The Korean Society of Law and Medicine
    • /
    • v.10 no.1
    • /
    • pp.307-322
    • /
    • 2009
  • More than 80% of Japanese still want to face death at home, but only 10% of them can have his/her last moments of life at home. On the other hand, the end-of-life care has been a big issue in both ethical and economic aspect because of euthanasia and healthcare costs. It is generally known that the end-of-life care spends much more than the care for nonterminal years. This study approaches the key for the end-of-life care and suggests a desirable solution.

  • PDF

Comparative Analysis of Coding Performance of Several ECG Compression Methods (ECG 압축 방법들의 코딩 성능 비교 분석)

  • Jang, Seung-Jin;Song, Sang-Ha;Yun, Yeong-Ro
    • Proceedings of the KIEE Conference
    • /
    • 2008.04a
    • /
    • pp.137-138
    • /
    • 2008
  • 수많은 방식의 ECG 압축 코딩 알고리즘이 개발되어왔고 현재도 개발 중이지만 각자의 알고리즘의 성능에 유리한 특정 데이터만을 분석하고 압축율이 다름으로 인해 다른 알고리즘과의 성능 비교를 객관화하고 있지 못하였다. 본 연구에서는 기존의 MIT-BIH에서 제공하는 ECG 신호와 달리 시뮬레이션된 ECG 신호를 기반으로 각각의 알고리즘에 대한 성능비교를 하여 ECG신호의 특성에 따른 코딩 알고리즘의 압축율 및 평균 오차 에러의 정도를 분석비교하였다. 비교 대상 알고리즘으로는 상용화되어 널리 사용되는 Delta 코팅 방식의 문턱치를 갖는 Discrete Pulse Code Modulation과 Discrete Cosine Transform, Lifting Wavelet Transform과 Wavelet 기반 Linear Prediction 4가지 알고리즘을 대상으로 분석하였다. Compression Ratio (CR)을 2,4로 고정하고 Percentage of Root-mean-square difference (PDR)를 분석 한 결과, EMG 잡음의 진폭변 화에는 0.1mV이하의 경우 OCT, Wavelet Lifiting Transform이 낮은 PDR을 보였고, 01.mV이상의 경우 Wavelet based Linear Prediction (WLP)이 낮은 PDR을 보였다. Heart Rate의 간격에 변화를 주어 불규칙성이 있는 경우 WLP가 가장 안좋은 PDR 결과를 보였으며, DCT가 가장 낮고 안정된 PDR 결과를 보였다. DPCM은 노이즈와 진폭간격의 변화에 상관없이 압축율에 의해 크게 PDR 성능 결과가 변화함을 나타내었다.

  • PDF

The Unconstrained Sleep Monitoring System for Home Healthcare using Air Mattress and Digital Signal Processing (공기 매트리스와 디지털 신호처리를 이용한 홈헬스케어용 무구속 수면 모니터링 시스템)

  • Chee, Young-Joon;Park, Kwang-Suk
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.493-496
    • /
    • 2005
  • For home healthcare, the unconstrained measurement of physiological signal is highly required to avoid the inconvenience of users. The recording and analysis of the fundamental parameters during sleep like respiration and heart beat provide valuable information on his/her healthcare. Using the air mattress sensor system, the respiration and heart beat movements can be measured without any harness or sensor on the subject's body. The differential measurement technique between two air cells is adopted to enhance the sensitivity. The balancing tube between two air cells is used to increase the robustness against postural changes during the measurement period. The meaningful frequency range could be selected by the pneumatic filter with balancing tube. ECG (Electrocardiography) and respiration sensor (plethysmography) were measured for comparison with the signal from air mattress. To extract the heart beat information from air pressure sensor, digital signal processing technique was used. The accuracy for breathing interval and heart beat monitoring was acceptable. It shows the potentials of air mattress sensor system to be the unconstrained home sleep monitoring system.

  • PDF

Development of Wearable Electro-stethoscope Module for Home-healthcare (홈 헬스케어를 위한 무구속 전자청진 모듈의 개발)

  • Kim, Dong-Jun;Lee, Hyun-Min;Woo, Seung-Jin;Lee, Ju-Shin;Lee, Jeong-Whan;Kim, Kyeong-seop
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.1 no.3
    • /
    • pp.41-47
    • /
    • 2008
  • This paper describes a wearable electro-stethoscope module for home-healthcare system. The module is consisted of a microphone, an instrumentation amplifier, a filter, a power amplifier etc. and is light and small. The phonogram signal from the module shows good performance. The test for the material and size of the sound collector of the chest piece is performed and the results is reflected on the prototype product. If the module is connected to wired or wireless communication network, so people can check their health without going hospital.

  • PDF

A Study on Standardization of Home Gateway for U-Healthcare Services (U-Healthcare 서비스를 위한 홈게이트웨이 표준안 모델 연구)

  • Yu, Jin-Keun;Seo, Dae-Young
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2007.06d
    • /
    • pp.425-430
    • /
    • 2007
  • 본 연구에서는 가정내 환자가 Zigbee 등의 센서로 측정한 생체정보들을 통하여 U-Healthcare 서비스를 하려고 할 때 고려하여야 하는 홈네트워크의 표준화를 위하여 홈네트워크 미들웨어들의 동향을 간단히 알아보고 그에 준하여 홈게이트웨이의 표준을 연구하고 최적 모델을 도출하여 그에 따라 프로토타입을 설계 후 구현하였다.

  • PDF