• 제목/요약/키워드: Holographic Particle Velocimetry

검색결과 17건 처리시간 0.027초

펄스 홀로그래프를 이용한 입자 속도 측정 시스템의 검증 실험 (Validation Experiments for a Holographic Particle Velocimetry System)

  • 오대진;추연준;강보선
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.714-719
    • /
    • 2001
  • The Holographic Particle Velocimetry system can be a promising optical tool for the measurements of three dimensional particle velocities. In this research, the optical system for double pulse holographic recording and reconstruction of particle images was developed. Validation experiments for the developed system were conducted measuring the velocities of glass beads on a rotating disk. Uncertainty analysis was performed to identify the sources of all relevant errors and to evaluate their magnitude. The measurement results of distance between glass beads, size, and velocities of them using holographic method compared reasonalbly well with the known values within acceptable range of errors.

  • PDF

홀로그래피를 이용한 분무 액적 속도 측정시스템 개발을 위한 실험적 검증 (Experimental Validation for the Development of Holographic Particle Velocimetry System for Spray Droplets)

  • 강보선;오대진;추연준
    • 대한기계학회논문집B
    • /
    • 제26권4호
    • /
    • pp.539-546
    • /
    • 2002
  • The Holographic Particle Velocimetry system can be a promising optical tool leer the measurements of three dimensional particle velocities. In this research, validation experiments for the development of holographic particle velocimetry system for spray droplets were conducted with measuring the velocities of glass beads on a rotating disk. Uncertainty analysis was performed to identify the sources of all relevant errors and to evaluate their magnitude. The measurement results of distance between glass beads, size, and velocities obtained with holographic method are compared reasonably well with the known values within acceptable range of errors.

홀로그래피 입자속도 측정시스템의 개발과 분무 액적에의 적용 (Development of Holographic Particle Velocimetry System and Its Application to Spray Droplets)

  • 추연준;강보선
    • 한국분무공학회지
    • /
    • 제10권3호
    • /
    • pp.17-28
    • /
    • 2005
  • The Holographic Particle Velocimetry system can be a promising optical tool for the measurements of three dimensional particle velocities. In this study, diffused illumination holographic system to measure the sizes and 3D velocities of moving particles based on automatic image processing was developed. First of all basic optical systems for pulse laser recording, continuous laser reconstruction, and image acquisition, were constructed. To determine the position of particles in the optical axis, new three auto-focusing parameters(AEP), namely, Correlation Coefficient, Sharpness Index, and Depth Intensity were introduced and verified. The developed system was applied to spray droplets to validate the capability of the system. Three dimensional positions of particles viewed from two sides were decided using AFP and then 3D velocities of Particles were extracted by particle tracking algorithm. Comparison of measurement results of sizes and 3D velocities of particles with those obtained by laser instrument, PDPA, showed good consistency of the developed holographic system.

  • PDF

Digital Holographic Particle Tracking Velocimetry 기법을 사용한 동물성 플랑크톤(요각류 Calanus sinicus)의 헤엄침 양태 연구 (Swimming Behavior Study of the Zooplankton(Copepod Calanus sinicus) by Using a Holographic Particle Tracking Velocimetry Technique)

  • 손명환;박병화;최용석;이상준;강영실;강양순
    • 한국군사과학기술학회지
    • /
    • 제13권5호
    • /
    • pp.941-949
    • /
    • 2010
  • The present study investigated the swimming pattern and appendage postures of a copepod species, Calanus sinicus, which prevails in the south-east sea of the Korean peninsula, by employing a digital holographic particle tracking velocimetry(PTV) technique. The results showed that the copepod Calanus sinicus had various swimming patterns such as hover, hop, sink, cruise, and downward cruise. Most frequent pattern was the 'hop and sink'. The average swimming speeds ranged from 1.1 to 45.7 body-lengths/s, and the corresponding flow Reynolds number ranged from $10^0$ to $10^2$.

Measurements of Three-Dimensional Velocities of Spray Droplets Using the Holographic Velocimetry System

  • Choo, Yeon-Jun;Kang, Bo-Seon
    • Journal of Mechanical Science and Technology
    • /
    • 제17권7호
    • /
    • pp.1095-1103
    • /
    • 2003
  • The Holographic Particle Velocimetry system can be a promising optical tool for the measurements of three dimensional particle velocities. In this study, the holographic particle velocimetry system was used to measure the sizes and velocities of droplets produced by a commercial full cone spray nozzle. As a preliminary validation experiment, the velocities of glass beads on a rotating disk were measured with uncertainty analysis to identify the sources of all relevant errors and to evaluate their magnitude. The error of the particle velocity measured by the holographic method was 0.75 ㎧, which was 4.5% of the known velocity estimated by the rotating speed of disk. The spray droplet velocities ranged from 10.3 to 13.3 ㎧ with average uncertainty of ${\pm}$ 1.6 ㎧, which was ${\pm}$ 14% of the mean droplet velocity. Compared with relatively small uncertainty of velocity components in the normal direction to the optical axis, uncertainty of the optical axis component was very high. This is due to the long depth of field of droplet images in the optical axis, which is inherent feature of holographic system using forward-scattering object wave of particles.

홀로그래피를 이용한 분무 액적의 3차원 속도 측정 (Measurements of Three-Dimensional Droplet Velocities Using the Holographic System)

  • 오대진;추연준;강보선
    • 한국분무공학회지
    • /
    • 제6권4호
    • /
    • pp.31-38
    • /
    • 2001
  • The Holographic Particle Velocimetry system can be a promising optical tool for the measurements of three dimensional particle velocities. In this study, the holographic panicle velocimetry system was used to measure the sizes and velocities of droplets formed by a commercial full cone spray nozzle. Uncertainty analysis was performed to identify the sources of all relevant errors and to evaluate their magnitude. The droplet velocities ranged from 10.3 to 13.3 m/s with average uncertainty of ${\pm}1.6m/s$, which is ${\pm}14%$ of the mean droplet velocity. Compared with relatively small uncertainties of velocity components in the normal direction to the optical axis, the uncertainty of the optical axis component is ${\pm}3.6m/s$. This is due to the long depth of field of droplet images in the optical axis, which is inherent feature of holographic system using forward-scattering object wave of particles.

  • PDF

입자 홀로그래피에서 입자의 광축 방향 위치 특성에 관한 연구 (The Characteristics of the Particle Position Along an Optical Axis in Particle Holography)

  • 추연준;강보선
    • 대한기계학회논문집B
    • /
    • 제30권4호
    • /
    • pp.287-297
    • /
    • 2006
  • The Holographic Particle Velocimetry system can be a promising optical tool for the measurements of three dimensional particle velocities. One of inherent limitations of particle holography is the very long depth of field of particle images, which causes considerable difficulty in the determination of particle positions in the optical axis. In this study, we introduced three auto-focusing parameters corresponding to the size of particles, namely, Correlation Coefficient, Sharpness Index, and Depth Intensity to determine the focal plane of a particle along the optical axis. To investigate the suitability of the above parameters, the plane image of dot array screens containing different size of dots was recorded by diffused illumination holography and the positions of each dot in the optical axis were evaluated. In addition, the effect of particle position from the holographic film was examined by changing the distance of the screen from the holographic film. All measurement results verified that the evaluated positions using suggested auto-focusing parameters remain within acceptable range of errors. These research results may provide fundamental information for the development of the holographic velocimetry system based on the automatic image processing.

디지털 Micro Holographic PTV기법을 이용한 미세 곡관 내부 3차원 유동 측정 (Measurement of 3-D Flow inside a Micro Curved-tube using Digital Micro Holographic Particle Tracking Velocimetry)

  • 김석;이상준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2579-2584
    • /
    • 2007
  • A digital micro holographic particle tracking velocimetry (HPTV) system consisting of a high-speed camera and a single laser with acoustic optical modulator (AOM) chopper was established. The digital micro HPTV system was applied to water flow in a micro curved-tube for measuring instantaneous 3-D velocity field data consecutively. The micro curved-tube is using to reproduce the dorsal aorta or utilize in various lap-on-a-chip. The temporal evolution of a three-dimensional water flow in the micro curved-tube (the curvature, ${\kappa}$=1/${\phi}$, 2/${\phi}$, 4/${\phi}$, 8/${\phi}$) of 100 ${\mu}m$ and 300 ${\mu}m$ inner diameters was obtained and mean velocity field distribution was obtained by statistical-averaging the instantaneous velocity fields.

  • PDF

입자 농도가 Digital Holographic PTV 측정에 미치는 영향에 관한 연구 (Effect of Particle Concentration on Digital Holographic PTV Measurement)

  • 김석;이상준
    • 대한기계학회논문집B
    • /
    • 제30권10호
    • /
    • pp.929-934
    • /
    • 2006
  • The digital HPTV(holographic particle tracking velocimetry) velocity field measurement system consists of four steps: recording, numerical reconstruction, particle extraction and velocity extraction. In the velocity extraction process, we improved the two frame PTV algorithm to extract 3-D displacement information of each particle located in 3D space. Because a digital CCD camera was used, some factors such as spatial resolution, numerical aperture, and particle concentration influenced on the performance of the developed digital HPTV. Especially, the particle concentration $(C_o)$ affected the reconstruction efficiency and recovery ratio in the numerical reconstruction and particle extraction procedure. In this paper, the effect of particle concentration reconstruction efficiency and recovery ratio were analyzed experimentally. Optimal particle concentration was found to be in the range of $C_o=11{\sim}17\;particles/mm^3$.

디지털 홀로그래픽 입자유속계를 이용한 미세곡관 내부유동 측정 (Measurement of Flow inside Curved Microtube Using a Digital Micro Holographic Particle Velocimetry)

  • 김석;이상준
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2007년도 추계학술대회
    • /
    • pp.116-118
    • /
    • 2007
  • Three-dimensional (3D) velocity field information of a laminar flow in a curved micro tube of circular cross-section has been measured using a digital micro holographic particle tracking velocimetry (HPTV). The temporal evolution of instantaneous velocity field of a water flow in a curved micro tube of $100\;{\mu}\;m$ and $300\;{\mu}\;m$ in inner diameter was obtained. The 3D mean velocity field distribution was obtained quantitatively by statistical-averaging of instantaneous velocity fields. At low Dean number (De), a secondary flow was not generated in the curved tube. With increasing Dean number, the secondary flow constituted of two large-scale counter-rotating vortices was formed due to enhanced centrifugal force. To reveal the flow characteristics of high Dean numbers, trajectories of fluid particles were evaluated experimentally from the 3D velocity fields data measured by the HPTV technique. The present experimental results, especially the 3D particle trajectories, would be helpful to design and to understand the mixing phenomena in 3D curved passages of various curved micro-tubes or micro-channels.

  • PDF