• 제목/요약/키워드: Holographic Interferometer

검색결과 33건 처리시간 0.042초

DFB 레이저 다이오드를 위한 홀로그래픽 시스템을 이용한 회절격자 제작 (Grating fabrication for DFB laser diode using holographic interferometer system)

  • 강명구;오환술
    • 전자공학회논문지A
    • /
    • 제33A권6호
    • /
    • pp.108-113
    • /
    • 1996
  • Periodic gratings for 1.55$\mu$m distributed feedback laser diode (DFB LD) have been fabricated by a holographic interference exposure system using an etalon stabilized Ar ion laser. We obtain a good development condition at developer concentration of 65% and obtain etching rate of 1000$\AA$/min at 20.deg. C by the mixed solution HBr:HNO$_{3}$:H$_{2}$O(1:1:10 in volume ratio). We obtain good first order grating with period of 2400${\AA}[\pm}2{\AA}$ at etching time of 45 sec from grating period and diffraction efficiency measurement, and SEM observation of grating fabricated on InP substrate.

  • PDF

발열체와 부분 열림 수직벽을 갖는 사각 공간내 자연대류 특성 해석 (A Study on the Characteristics of Natural Convection in a Partially Opened Enclosure with a Heat Source)

  • 심동식;강보선;차동진;주원종
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.322-327
    • /
    • 2000
  • Natural convection heat transfer in an enclosure with an opening in the right vertical wall and a heat source at the bottom surface is investigated using a holographic interferometric technique. The effects of the opening length, divider length attached to the top wall, and heater temperature on the temperature distribution are examined. The openging length as well as the divider length greatly affects the degree of inflow and outflow of air. With a small opening, the opening doesn't affect much the upward warm air flow resulting in the symmetric temperature distribution. On the other hand, with the increase of the opening length, the inward cold flow moves the upward flow to the left direction. With the increase of the divider length, temperature in the lower region of enclosure becomes higher for the small opening and lower for the large opening.

  • PDF

Wavefront 3D Reconstruction and Measurement for Natural 3D Display System

  • Matoba, Osamu;Nitta, Kouichi;Awatsuji, Yasuhiro
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.935-938
    • /
    • 2008
  • Three-dimensional (3D) display systems based on wavefront reconstruction are presented. To obtain the wavefront of 3D objects, we present holographic recording using temporally or spatially phase-shifting interferometer. In the 3D display systems, phase-only reconstruction using a spatial light modulator and an approach to increase the reconstructed power are presented.

  • PDF

LCD를 이용한 복소홀로그램의 실시간적 복원 (Real-time reconstruction of complex holograms using LCDs)

  • 김수길;김규태;이병호;김은수;손중영
    • 전자공학회논문지D
    • /
    • 제34D권4호
    • /
    • pp.54-61
    • /
    • 1997
  • In this paper, a new holographic display system that can in real-time reconstruct the complex hologram without the bias and the conjugate image, which is obtained form the modified triangular interferometer, is presented. The proposed system is made of adding liquid crystal displays(LCDs), a $\lambda$/2 wave plate, and a polarizing beam splitter to the conventional mach-zehnder interferontric configuration. We demonstrate through theoretical analysis and experiment that real-time image reconstruction from the complex hologram is possible using the proposed system.

  • PDF

층 밀리 간섭계를 이용한 고체침지렌즈의 광학적 성능 평가 (Optical Performance Evaluation of SIL Assembly with Lateral Shearing Interferometer)

  • 이진의;김완진;최현;김태섭;윤용중;박노철;박영필
    • 정보저장시스템학회논문집
    • /
    • 제2권4호
    • /
    • pp.224-229
    • /
    • 2006
  • There has been studied flow to minimize the spot size to increase data capacity. Optical data storage devices are being developed near practical limits with wavelength and NA of 405nm and 0.85. There has been studied many types of next generation storage devices such as blu-ray multilayer system, probe based data storage and holographic data storage. Among these data storage devices, solid immersion lens(SIL) based near field recording (NFR) has been widely studied. In this system, SIL is the key component that focuses the laser beam with a very small size which enables ultra high data capacity. Therefore, optical performance evaluation system is required for SIL assembly. In this dissertation, a simple and accurate SIL assembly measurement method is proposed with wedge plate lateral shearing interferometer(LSI). Wedge plate LSI is cheaper than commercialized interferometer, robust to the vibration and the moving distance for phase shifting is large that is order of micrometer. We designed the thickness, wedge angle, material, surface quality and wavelength of wedge plate as 1mm, 0.02degree, fused silica, lamda/10(10-5) and 405nm, respectively. Also, we confirmed simulation and experimental results with quantitative analysis. This simple wedge plate LSI can be applied to different types of SIL such as solid immersion mirror(SIM), hemispherical, super-hemispherical and elliptical SIL.

  • PDF

발열체와 부분 열림 수직벽을 갖는 사각 공간 내 자연대류 특성 해석 (A Study on the Characteristics of Natural Convection in a Partially Opened Enclosure with a Heat Source)

  • 심동식;강보선;차동진;주원종
    • 대한기계학회논문집B
    • /
    • 제24권12호
    • /
    • pp.1588-1595
    • /
    • 2000
  • Natural convection heat transfer in an enclosure with an opening in the right veritcal wall and a heat source at the bottom surface is investigated using a holographic interferometric technique. The effects of the opening length, divider length attached to the top wall, and heater temperature on the temperature distribution are examined. The opening length as well as the divider length greatly affects the degree of inflow and outflow of air. In the case of small opening length, the opening doesnt affect much the upward warm air flow resulting in the symmetric temperature distribution .The upward flow in hindered by the divider resulting in the decrease of heat transfer from the heater region to the upper region. The longest divider shows the highest temperature in the lower region of enclosure. In the case of large opening length, the inward cold flow moves the upward flow to the left direction. Among the cases of different divider length, the case of H(sub)d=0.25H shows the highest temperature in the lower region of enclosure.

Two-step Holographic Imaging Method based on Single-pixel Compressive Imaging

  • Li, Jun;Li, Yaqing;Wang, Yuping;Li, Ke;Li, Rong;Li, Jiaosheng;Pan, Yangyang
    • Journal of the Optical Society of Korea
    • /
    • 제18권2호
    • /
    • pp.146-150
    • /
    • 2014
  • We propose an experimental holographic imaging scheme combining compressive sensing (CS) theory with digital holography in phase-shifting conditions. We use the Mach-Zehnder interferometer for hologram formation, and apply the compressive sensing (CS) approach to the holography acquisition process. Through projecting the hologram pattern into a digital micro-mirror device (DMD), finally we will acquire the compressive sensing measurements using a photodiode. After receiving the data of two holograms via conventional communication channel, we reconstruct the original object using certain signal recovery algorithms of CS theory and hologram reconstruction techniques, which demonstrated the feasibility of the proposed method.

홀로그래픽 방법을 사용한 다중 광섬유 격자 제작과 이를 이용한 온도 센서 시스템 (Fabrication of multiple fiber Bragg grating by holographic method and its application to the temperature sensor system)

  • 이경신;유은미;손주연;김근진;윤재순;최기선;백세종;임기건
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2009년도 동계학술발표회 논문집
    • /
    • pp.295-296
    • /
    • 2009
  • 다중 브래그 파장의 안정성 확보하고 제작비용을 줄이기 위하여 본 연구에서는 하나의 위상마스크와 스텝당 0.004도의 분해능을 갖는 탤봇 간섭계(Talbot Interferometer)로 이루어진 홀로그래픽 격자제작장치를 구성하였다. C-밴드와 L-밴드 파장 범위 내의 다중 브래그 파장 특성을 실험적으로 확인하고, 이 방법을 사용하여 서로 다른 파장의 브래그 격자를 센서부로 두고, $1{\times}6$ 광분배기와 결합시켜 화학반응조 내의 액체 온도를 측정하는 시스템을 제작하였다.

  • PDF

Using Pulse-Front Tilt to Measure Laser Pulses Less Than 100 Picoseconds in Duration

  • Jeong, Hoon
    • 한국광학회지
    • /
    • 제26권6호
    • /
    • pp.318-321
    • /
    • 2015
  • We demonstrate a frequency-resolved optical grating (FROG) device for measuring the intensity and phase versus time of several-tens-of-picoseconds laser pulses, using a thick nonlinear optical crystal. The huge pulse-front tilt generated by a holographic grating increases the temporal range of the device, which can make a single-shot measurement of laser pulses less than 100 ps in duration. To verify the measurement technique, we generate double pulses using a Michelson interferometer. The measured duration of a single pulse is about 300 fs and the measured maximum delay of two pulses is 60 ps, which implies that the proposed FROG device can measure laser pulses with maximum pulse width of about 120 ps.

인코히런트 광원을 이용한 영상의 동기 가감 (Simultaneous Addition and Subtraction of Optical Images by Using the Extended Incoherent Source)

  • 박형래;전석희;박한규
    • 대한전자공학회논문지
    • /
    • 제23권6호
    • /
    • pp.961-967
    • /
    • 1986
  • A technique of optical image synthesis with an extended incoherent source is presented and compared with the coherent method. A holographic diffraction grating is fabricated by using Michelson interferometer, and by equalizing the 8th-order to the 2nd-order diffraction efficiency, complex amplitude addition and subtracdtion of optical images are simultaneously realized. The experiment shows that the quality of synthesized optical images in the incoherent method is improved in comparison with that of the coherent method by suppressing the coherent artifact noise.

  • PDF