• Title/Summary/Keyword: Hollow fiber membrane

Search Result 425, Processing Time 0.03 seconds

Development of High-Permeability Ceramic Hollow Fiber and Evaluation of CH4/CO2 Separation Characteristics of Membrane Contactor Process (고투과성 세라믹 중공사 개발과 접촉막 공정의 CH4/CO2 분리 특성 평가)

  • Lee, Seung Hwan;Kim, Min Kwang;Jeong, Byeong Jun;Zhuang, Xuelong;Park, Jung Hoon
    • Membrane Journal
    • /
    • v.30 no.4
    • /
    • pp.269-275
    • /
    • 2020
  • In this study, CO2 separation experiment was performed on a CH4/CO2 mixed gas using a ceramic hollow fiber membrane contactor (HFMC). In order to fabricate high-performance HFMC, experiments were conducted to manufacture high-permeability hollow fiber membranes, and the prepared hollow fiber membranes were evaluated through N2 gas permeation experiments. HFMC for CH4/CO2 mixed gas separation was manufactured using the manufactured high-permeability hollow fiber membrane. In the experiment, mixed gas of CH4/CO2 (34.5% CO2, CH4 balance) and monoetanolamine (MEA) was used, and the effect of CO2 removal efficiency on the flow rate of the absorbent was evaluated. The CO2 removal efficiency increased as the liquid flow rate increased, and the CO2 absorption flux also increased with the liquid flow rate.

Fabrication of Organic Solvent Resistant Polyketone Hollow Fiber Membranes (유기용매 저항성 Polyketone 중공사 분리막의 제조)

  • Park, Yeji;Jang, Wongi;Choi, Jinwon;Woo, Yunha;Hou, Jian;Jeon, Sungil;Byun, Hongsik
    • Membrane Journal
    • /
    • v.31 no.5
    • /
    • pp.363-370
    • /
    • 2021
  • Organic solvent resistant hollow fiber membranes were fabricated via a thermally induced phase separation (TIPS) method using Polyketone polymer, a material with excellent resistance to organic solvents. The PEG300, DMSO2 and Glycerine called the "green solvents" were used as diluents for TIPS method. The spherulite structure was formed with DMSO2 by S-L phase separation behavior whereas the bicontinuous structures were formed with PEG300 and Glycerine, respectively. The morphology of the PK hollow fiber membranes was investigated using SEM. The pure water permeability and the durability test were conducted to understand the permeation properties of PK hollow fiber membranes. The tensile strength test was conducted for the property of mechanical strength. In this study, the fabrication of PK hollow fiber membranes with various diluents was discussed to understand the correlation between diluent and polymer in detail.

Performance of a Hellow Fiber Membrane Diffuser for the Biological Removal of Gaseous BTX (Diffuer 형태의 중공사막 생물반응기를 이용한 기체상 BTX 제거)

  • Son, Young-Gyu;Khim, Jee-Hyeong;Song, Ji-Hyeon
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.4
    • /
    • pp.25-32
    • /
    • 2006
  • In this study, a novel bioreactor system using a diffuser type hollow fiber membranes (hollow fiber membrane diffuser, HFMD) was applied to investigate the feasibility and biodegradation capacity for the treatment of a gaseous mixture consisting of benzene, toluene and p-xylene(BTX). First, A mixed culture pre-acclimated to toluene effectively biodegraded the BTX mixture at an overall removal efficiency of approximately 70% for a 20-day operational period. It was found that the biodegradation of toluene was slightly inhibited because of the presence of benzene and p-xylene. Second, the elimination capacity (EC) of total BTX increased up to 360 $g/m^3/hr$, which was substantially higher than maximum ECs for BTEX reported in the biofiltration literature. Consequently, the hollow fiber membrane diffuser was considered as an alternative method over other conventional VOC-treating technologies such as biofilters.

Improvement of Separation of Polystyrene Particles with PAN Membranes in Hollow Fiber Flow Field-Flow Fractionation

  • Shin, Se-Jong;Chung, Hyun-Joo;Min, Byoung-Ryul;Park, Jin-Won;An, Ik-Sung;Lee, Kang-Taek
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.9
    • /
    • pp.1333-1338
    • /
    • 2003
  • Hollow Fiber flow field-flow fractionation (HF-FlFFF) has been tested in polyacrylonitrile (PAN) membrane channel in order to compare it with polysulfone (PSf) membrane channel. It has been experimentally shown that the separation time of 0.05-0.304 ${mu}m$ polystyrene latex (PSL) standards in PAN membrane channel is shorter than that in PSf channel by approximately 65%. The optimized separation condition in PAN membrane is ${\dot V}_{out}/{\dot V}_{rad}=1.4/0.12\;mL/min$, which is equal to the condition in PSf membrane channel. In addition both the resolution ($R_s$) and plate height (H) in PAN membrane channel are better than that in PSf membrane channel. The membrane radius was obtained by back calculation with retention time. It shows that the PSf membrane is expanded by swelling and pressure, but the PAN membrane doesn't expand by swelling and pressure.

Clinical Application of OXYREX Hollow Fiber Membrane Oxygenator (국산 막형 산화기 (OXYREX)의 체외순환 임상 성적 - 개심수술 40례 적용 -)

  • 김형묵
    • Journal of Chest Surgery
    • /
    • v.23 no.6
    • /
    • pp.1049-1056
    • /
    • 1990
  • The OXYREX hollow fiber membrane oxygenator developed by joint work of KIST and Green Cross Medical company has been evaluated by experimental investigation and clinical application, In this oxygenator gas exchanges occur through small pores of 0.1pm size which are distributed on 70% of surface of polypropylene hollow fiber. The Oxyrex membrane oxygenator consists of 36 thousand hollow fibers and it has 3.3m2 of gas exchange surface. The Oxyrex membrane oxygenator has unique blood flow path: blood enters the oxygenator passes between the hollow fibers and exits through outlet ports, that provides low transmembrane pressure drop. In the animal experiment and in vitro investigations of Oxyrex oxygenator, it showed low transmembrane pressure difference, effective heat exchanger performance, stable gas transfer function and less blood trauma. The Oxyrex oxygenator been used from March, 1990, to October, 1990, in 40 patients undergoing open heart operations. In the clinical applications of Oxyrex, adequate oxygenation[PaO2, 283$\pm$70mmHg] and carbon dioxide removal[PaCO2, 27\ulcorner6mmHg]were maintained under the condition of FiO2: below 0.6, Hct; 25%, perfusion flow; 2.4 L/min, gas flow: 2.1 L/min. During maximum 365 minutes of cardiopulmonary bypass[CPB] time period, the Oxyrex oxygenator maintained stable condition of PaO2, PaCO2 respectively and it also kept low plasma hemoglobin level. The complement proteins C3 and CH50 were not significantly changed pre to post CPB. There were no complications related to the oxygenator during and after the CPB.

  • PDF

Measurement of Liquid Entry Pressure of PE and PVDF Hollow Fiber Membranes in Membrane Distillation Process (막증류 공정에서 PE 및 PVDF 중공사막의 액체투과압력 측정에 관한 연구)

  • Min, Ji Hee;Park, Min Soo;Kim, Jinho
    • Membrane Journal
    • /
    • v.25 no.3
    • /
    • pp.216-222
    • /
    • 2015
  • The method measuring LEP (liquid entry pressure) was optimized to evaluate the wettabilities of hydrophobic membranes which might affect long-term durability of membrane in MD (membrane distillation) process. Conductivity of the permeate was monitored to measure the LEPs of PE (polyethylene) and PVDF (polyvinylidene di-fluoride) hollow fiber membranes from highly concentrated synthetic feed water of 20 wt% NaCl. Holding time over 5 min and the ratio of membrane area to the tank volume more than $10m^2/m^3$ were required to ensure LEP value.

Study on a Gas Separation Using Circulatory Membrane Absorber Conditioned with non-Watted Hollow-Fibers (비젖음성 중공사조건의 순환식 막 흡수기에 의한 기체분리에 관한 연구)

  • 전명석;이규호
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1994.10a
    • /
    • pp.36-37
    • /
    • 1994
  • Sirkar등[1]이 많이 연구한 hollow-fiber contained liquid membrane방식보다 막내부에서의 물질전달 저항을 크게 낮출 수 있는 이른바 flowing liquid membrane방법을 Teramoto등[2]은 제안하였다. 좀더 발전된 membrane absorber방식으로서 평판형(flat-sheet type)막으로 흡수(absorption) 및 탈착(desorption)모듈을 구성하고, monoethanolamine 흡수제(absorbent)로 $Co_2/CH_4$ 분리에 적용하여 선택도를 크게 향상시킨 기존의 실험결과도 볼 수 있다. 막에서의 기-후 접촉과 반응이 수반된 물질전달에 의한 기체흡수 현상에 관해 많은 이론해석과 실험결과가 연구된 바 있다. 본 연구에서는 이산화탄소와 같은 산성기체(acid gas)의 분리에 주로 적용될 새로운 방식의 순환식 중공사막 흡수기 (circulatory hollow-fiber membrane absorber: HFMA)를 제안하고 이의 실제적용에 대한 기초로서 모델해석에 의한 분리성능을 예측하였다.

  • PDF

Separation of Colloidal Particles by Osmotic Sink Field Flow Fractionation Using UF Hollow Fiber Membranes

  • Shin, Se-Jong;Min, Byoung-Ryul;Park, Jin-Won;Ahh, Ik-Sung;Lee, Kang-Taek;Lee, Jae-Hoon
    • Korean Membrane Journal
    • /
    • v.3 no.1
    • /
    • pp.59-68
    • /
    • 2001
  • Unlike existent field flow fractionation, new method, osmotic sink field flow fractionation is introduced and used ultrafiltration hollow fiber membranes as separation channel. This hollow fiber osmotic sink field flow fractionation is called HF-OSFFF. A theory that describes the retention, relaxation, resolution, plate number for the system, has been developed and experimentally verified by separation model of po1ystyrene latex beads. At external field, it is measured that radial flow rates change according to various concentrations of PEG solutions. Concentration of PEG solution vs. radial flow rate is a linear relation. For diameter distribution of unknown polymer sample, HF-OSFFF compared with the commercial capillary hydrodynamic flow fractionation (CHDF).

  • PDF

Prepration of Hydoxy Polyimde Membranes and Their Carbon Dioxide Permeation Property (Hydroxy Polyimide 막의 제조와 이산화탄소 투과 특성)

  • Woo, Seung-Moon;Choi, Jong-Jin;Nam, Sang-Yong
    • Membrane Journal
    • /
    • v.22 no.2
    • /
    • pp.128-134
    • /
    • 2012
  • In this study, hydroxy polyimide (HPI) was prepared for non-porous membrane by solvent evaporation method. As the result of gas permeance properties measurement, $CO_2$ permeability was 85 Barrer and the $CO_2/N_2$ selectivity was 23 at $30^{\circ}C$. Flat sheet membrane and hollow fiber membrane were prepared by using ternary system of polymer, solvent and non-solvent additive. Morphologies and gas permeance properties were measured by FE-SEM and bubble flow meter. Each $CO_2$ permeability of 18.28 GPU, 70 GPU and $CO_2/N_2$ selectivity of 6.72, 8.63 at $30^{\circ}C$ in the flat sheet membrane and hollow fiber membrane. Hollow fiber membrane has gas permeance property better than flat sheet membrane.

PEI Hollow Fiber Membranes Modified with Fluorinated Silica Nanoparticles for the Recovery of Biogas from Anaerobic Effluents (불화 실리카로 개질된 폴리에테르이미드 중공사막을 이용한 혐기성 유출수로부터 바이오가스 회수)

  • Yun, Kang Hee;Wongchitphimon, Sunee;Bae, Tae-hyun
    • Membrane Journal
    • /
    • v.30 no.5
    • /
    • pp.326-332
    • /
    • 2020
  • In this study, polymer-fluorinated silica composite hollow fiber membranes were fabricated and applied to a membrane contactor for the recovery of methane dissolved in the anaerobic effluent. To prepare the composite membranes, porous hollow fiber substrates were fabricated with Ultem®, a commercial polyetherimide (PEI). Subsequently, fluorinated silica particles were synthesized and coated on the surface via strong covalent bonding. Due to the high porosity, our membrane showed a CH4 flux of 8.25 × 10-5 ㎤ (STP)/㎠·s at the liquid velocity of 0.03 m/s which is much higher that that of commercial polypropylene membrane designed for degassing processes. This is attributed to our membrane's high porosity as well as a superior surface hydrophobicity (120~122°) resulted from the coating with fluorinated silica nanoparticles.