• Title/Summary/Keyword: Hollow Fiber Membrane Module

Search Result 99, Processing Time 0.028 seconds

Simulation of Separation Properties of Propylene/propane in Silver Nanoparticle Containing Facilitated Transport Membrane (전산모사 프로그램을 이용한 은나노함유 촉진수송막의 프로필렌/프로판 분리특성 예측)

  • Park, Chae Young;Han, Sang Hoon;Kim, Jeong Hoon;Lee, Yongtaek
    • Membrane Journal
    • /
    • v.24 no.5
    • /
    • pp.409-415
    • /
    • 2014
  • This study is aimed to separate propylene and propane using membrane process instead of NCC(Naphtha Cracking Center) $C_3$ splitter. Membrane process is a low energy consumption and eco-friendly process while $C_3$ splitter requires high energy consumption in petrochemical processes. In this study, high performance facilitated transport membrane (FTM) is used for propylene/propane separation. FTM module was prepared on top of porous polyetherimide hollow fiber using PVP/$AgBF_4$/TCNQ. We developed simulation program predicting the membrane separation properties under operation conditions. Separation properties of FTM module for propylene and propane were obtained from the simulation program based on the pure gas permeation data. Based on these results, it is predicted that an one-stage membrane process provides 99.5% of propylene at permeate side from a binary gas mixture of 95/5 vol% $C_3H_6$ / vol% $C_3H_8$ supplied as a feed gas.

Development of High-rate Nitrogen Removal Process Using Submerged MBR Packed with Granular Sulfur of Pilot Scale Plant (Pilot Scale Plant의 황 충진 MBR을 이용한 고효율의 질소제거 공법 개발)

  • Mun, Jin-Yeong;Hwang, Yong-U;Jo, Hyeon-Jeong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.3
    • /
    • pp.383-390
    • /
    • 2011
  • In this study, a process combined biofiltration with sulfur-utilizing autotrophic denitrification and membrane separation was proposed to examine the efficiency of nitrogen removal. As an experimental device, hollow-fiber module was installed in the center of reactor to generate the flux forward sulfur layer in the cylinder packed with granular sulfur. In addition, a simple module was installed in activated sludge aeration tank which inside and outside of sulfur-using denitrification module was covered with microfilter and the module was considered as an alternative of clarifier. The experiment for developing new MBR process was carried out for three years totally. As the results of first two-year experiment, successful nitrogen removal performance was revealed with lab-scale test and pliot scale plant using artificial wastewater and actual plating wastewater. In this year, pilot scale test using actual domestic wastewater was performed to prove field applicability. As the results, high-rate nitrogen removal performance was confirmed with about 0.19 kg ${NO_3}^--N/m^3$ day of rate. Also significant fouling and pressure increase were not found during the experiment. And, the production ratio of sulfate and the consumption ratio of alkalinity showed a slightly higher value about 311 mg ${SO_4}^{2-}/L$ and 369 mg $CaCO_3$/L, respectively. In conclusion, the developed MBR process can be utilized as an alternative for retrofiting existing wastewater plants as well as new construction of advanced sewage wastewater treatment plants, with cost-effective merit.

Separation of dissolved gases from water using synthesized gases based on exhalation characteristics

  • Heo, Pil Woo;Park, In Sub
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.10
    • /
    • pp.1347-1353
    • /
    • 2014
  • It's possible for a human to breathe under water, if dissolved oxygen is effectively used. Fish can stay under water using the gill which extracts dissolved oxygen from water. Water includes small amounts of oxygen, so a human needs larger amounts of water to acquire oxygen enough for underwater breathing. The exhalation gas from a human is another method to get higher amounts of oxygen under water. It mainly composes of oxygen, nitrogen and carbon dioxide. So, if only carbon dioxide is decreased, the exhalation gas has good characteristics for breathing of a human under water. In this paper, composition of the exhalation gas from a human was analyzed using GC. Based on these results, the synthesized gas was prepared and mixed into water which was used for experimental devices to analyze separation characteristics of dissolved gases from water. Experimental devices included a water pump, a hollow fiber membrane module and a vacuum pump. The effects of pressure and water flow on separation characteristics of synthesized gas were investigated. The compositions of gases separated from water using synthesized gas were investigated using GC. These results expect to be applied to the development of underwater breathing technology for a human.

Numerical Analysis for Separation of Methane by Hollow Fiber Membrane with Cocurrent Flow (병류흐름 중공사 분리막에 의한 메탄 분리 수치해석)

  • Lee, Seungmin;Seo, Yeonhee;Kang, Hanchang;Kim, Jeonghoon;Lee, Yongtaek
    • Korean Chemical Engineering Research
    • /
    • v.53 no.3
    • /
    • pp.295-301
    • /
    • 2015
  • A theoretical analysis was carried out to examine the concentration behavior of methane from a biogas using a polysulfone membrane. After the governing equations were derived for the cocurrent flow mode in a membrane module, the coupled nonlinear differential equations were numerically solved with the Compaq Visual Fortran 6.6 software. At the typical operating condition of mole fraction of 0.7 in a feed stream, the mole fraction of methane in the retentate increased to 0.76 while the normalized retentate flow rate to the feed flow rate decreased from 1 to 0.79. When either the mole fraction of methane in a feed increased or the pressure of the feed stream increased, the methane mole fraction in the retentate increased. On the other hand, it was found that as either the membrane area decreased or the ratio of the permeate pressure to the feed pressure increased, the methane mole fraction in the retentate decreased. In case that the stage cut increased, the methane mole fraction in the retentate increased while the recovery of methane slightly decreased.

Optimum Operating Condition for Micro-Filtration Process as a Seawater Desalination Pretreatment (해수담수화 전처리로서 가압식 MF 공정의 최적 운전조건 도출)

  • Kim, Youngmin;Jang, Jung-Woo;Kim, Jin-Ho;Choi, June-Seok;Lee, Sangho;Kim, Sukwi
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.9
    • /
    • pp.624-629
    • /
    • 2013
  • The relation between performance maintenance conditions and those cost efficiency was studied to choose an optimum operating condition in the seawater desalination pretreatment system. A hollow fiber microfiltration module, which was developed with domestic technology, was tested with the various operating conditions such as chemically enhanced backwash cycles and design dosages of a cleaning chemical. Transmembrane pressure was measured to investigate membrane fouling status and cleaning degree. In addition, economic analysis was performed to compare water production costs by the operation condition. As a result, The operation mode III, chemically enhanced backwash at once a day with 100 mg/L of sodium hypochlorite (NaOCl) was selected. The concurrent evaluation between membrane filtration performance and its economic analysis will be suitable to choose an efficient optimum condition.

A Study of the Effect of the Permeability and Selectivity on the Performance of Membrane System Design (분리막 투과도와 분리도 인자의 시스템 설계 효과 연구)

  • Shin, Mi-Soo;Jang, Dongsoon;Lee, Yongguk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.12
    • /
    • pp.656-661
    • /
    • 2016
  • Manufacturing membrane materials with high selectivity and permeability is quite desirable but practically not possible, since the permeability and selectivity are usually inversely proportional. From the viewpoint of reducing the cost of $CO_2$ capture, module performance is even more important than the performance of membrane materials itself, which is affected by the permeance of the membrane (P, stagecut) and selectivity (S). As a typical example, when the mixture with a composition of 13% $CO_2$ and 87% of $N_2$ is fed into the module with 10% stage cut and selectivity 5, in the 10 parts of the permeate, $CO_2$ represents 4.28 parts and $N_2$ represents 5.72 parts. In this case, the $CO_2$ concentration in the permeate is 42.8% and the recovery rate of $CO_2$ in this first separation appears as 4.28/13 = 32.9%. When permeance and selectivity are doubled, however, from 10% to 20% and from 5 to 10, respectively, the $CO_2$ concentration in the permeant becomes 64.5% and the recovery rate is 12.9/13 = 99.2%. Since in this case, most of the $CO_2$ is separated, this may be the ideal condition. For a given feed concentration, the $CO_2$ concentration in the separated gas decreases if permeance is larger than the threshold value for complete recovery at a given selectivity. Conversely, for a given permeance, increasing the selectivity over the threshold value does not improve the process further. For a given initial feed gas concentration, if permeance or selectivity is larger than that required for the complete separation of $CO_2$, the process becomes less efficient. From all these considerations, we can see that there exists an optimum design for a given set of conditions.

The Evaluation of Artificial Lung Using Blood Substitutes (대체혈액을 이용한 인공폐의 평가에 관한 연구)

  • Kim K.B.;Hong S C.;Kim M.H.;Jheong G.R.;Lee S.C.
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.3 s.61
    • /
    • pp.311-320
    • /
    • 2000
  • In this paper a newly designed oxygenator module was used to perform the experiments for pressure drop and oxygen transport in order to evaluate the efficiency of the artificial lung. Also, distilled water. sodium sulfite solutions used in this experiment were evaluated for the performance of other artificial lungs. Substituted bloods have many advantages over whole blood in studying pressure drop and oxygen uptake. They are relatively inexpensive, and require fewer variables to be controlled. Furthermore, deoxygenation is not necessary when those solutions are used. In addition to these advantages. assays and interpretation of the experimental results are relatively easy. In the case of using the sodium sulfite solution having the same oxygen partial pressure as whole blood. the oxygen transfer rate of the sodium sulfite solution was basically same as that of whole blood. It was concluded in evaluating the function of artificial lungs that the sodium sulfite solution was suited for measuring oxygen transfer rate. In our module, artificial blood was flowed into the outside of hollow fiber membrane. The artificial lung created in this experiment showed that pressure drop was reduced to $1/3\~1/6$ of that compared to the inside-flow case.

  • PDF

Simultaneous Nitrification and Denitrification using Submerged MBR packed with Granular Sulfur and Non-woven Fabric (부직포 및 황 충진 MBR을 이용한 포기조내 동시 질산화/탈질에 관한 연구)

  • Moon, Jin-Young;Hwang, Yong-Woo;Park, Ji-Hyoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.4
    • /
    • pp.439-446
    • /
    • 2009
  • This study was performed to evaluate SND(simultaneous nitrification and denitrification)efficiency, nitrogen removal efficiency and filtration function of non-woven fabric by using submerging MBR packed with granular sulfur covered with non-woven fabric filter. Synthetic wastewater was used as influent wastewater. Concentration of $NH_4{^+}-N$ in influent was maintained about 40 mg/L and the experiment was performed in four phases according to the flow rate. Nitrogen loading rate divided four phases ranging from $0.04 kg\;NH_4{^+}-N/m^3-day$ to $0.16 kg\;NH_4{^+}-N/m^3-day$. As a result, the maximum $NH_4{^+}-N$ removal rate was accomplished at $0.142 kg\;NH_4{^+}-N/m^3-day$ in nitrogen loading of $0.147 kg\;NH_4{^+}-N/m^3-day$. Nitrification efficiency was higher than 95% in all phases. $NO_3{^-}-N$ loading rate was adjusted ranging from $0.22 kg\;NO_3{^-}-N/m^3-day$ to $0.89 kg\;NO_3{^-}-N/m^3-day$. The maximum $NO_3{^-}-N$ removal rate was accomplished up to $0.71 kg\;NO_3{^-}-N/m^3-day$ in $NO_3{^-}-N$ loading of $0.89 kg\;NO_3{^-}-N/m^3-day$. The maximum $NO_3{^-}-N$ removal efficiency was 95% in $NO_3{^-}-N$ loading of $0.22 kg\;NO_3{^-}-N/m^3-day$. T-N removal rate was 90% and concentration of T-N in effluent was 3.7 mg/L in T-N loading rate of $0.039 kg\;NO_3{^-}-N/m^3-day$. In this study, TMP in reactor with and without non-woven fabric filter were observed to define fouling of hollow-fiber membrane module. Reaching time to standard washing pressure(22 cm Hg) of two reactors were 29 days with non-woven fabric But the reactor without non-woven fabric reached standard washing pressure only after 4 days. Accordingly, non-woven fabric was demonstrated the superiority as a filtration ability. With high nitrogen removal rate and decreasing of fouling of membrane, MBR packed with granular sulfur covered with non-woven fabric filter submerging in activated sludge aeration tank can be used as an advanced treatment process.

Value Addition of Jujube Wine using Microfiltration and Ultrafiltration (미세여과와 한외여과를 이용한 대추술의 고품질화)

  • Kang, Hyun-Ah;Chang, Kyu-Seob;Min, Young-Kyoo;Choi, Yong-Hee
    • Korean Journal of Food Science and Technology
    • /
    • v.30 no.5
    • /
    • pp.1146-1151
    • /
    • 1998
  • To prevent deterioration of the jujube wine quality by using heat sterilization while commercial production, ultrafiltration and microfiltration were applied. The permeate flux and physicochemical properties of jujube wine determined by MF and UF membrane ($0.2\;{\mu}m$ pore size and 50 K dalton cut off) were investigated. The permeate flux increasing caused the increased operating pressure. The Hunter L value of jujube wine treated MF and UF was increased and that of b value was decreased. The turbidity of jujube wine treated MF and UF was largely decreased. And the values of pH, ethanol, total acid and soluble solid were decreased or were at the same level comparing with untreated jujube wine. Retention percentage of sugar and organic acid was more than 80% and was not influenced by operating pressure. Results of sensory evaluation indicated that the color of UF was superior to un-treatment and commercial ones. And the flavor and taste were not significantly different with untreated jujube wine. The quality deterioration of commercial jujube wine could be improved by MF and UF. According to the sensory evaluation, there was also not difference between MF and UF for preference test. Therefore, the quality of jujube wine could be improved by MF having better separation yield efficiency than UF.

  • PDF