• 제목/요약/키워드: Holdup time

검색결과 16건 처리시간 0.023초

Precise Analytical Solution for the Peak Gain of LLC Resonant Converters

  • Hong, Sung-Soo;Cho, Sang-Ho;Roh, Chung-Wook;Han, Sang-Kyoo
    • Journal of Power Electronics
    • /
    • 제10권6호
    • /
    • pp.680-685
    • /
    • 2010
  • Although LLC resonant converters have the advantages of a wide operation range and high efficiency, the lack of an analytical solution for the peak gain makes it difficult to optimize the resonant tank design, when considering not only the normal condition but also the holdup time requirement. In this paper, based on a mathematical analysis of a LLC resonant converter at the peak gain point, an analytical solution for the peak gain has been developed. By using the developed analytical solution, the peak gain with given resonant tank parameters can be obtained. To confirm the validity of the developed analytical solution, simulations and experimental results are compared.

액체-입자 Swirling 유동층에서 유동입자 흐름 및 열전달 특성 (Characteristics of Particle Flow and Heat Transfer in Liquid-Particle Swirling Fluidized Beds)

  • 손성모;강석환;강 용;김상돈
    • Korean Chemical Engineering Research
    • /
    • 제44권5호
    • /
    • pp.505-512
    • /
    • 2006
  • 직경이 0.102 m이고 높이가 2.5 m인 액체-입자 swirling(나선)흐름 유동층에서 유동 입자의 흐름 및 열전달 특성을 고찰하였다. 액체유속($U_L$), 유동 입자의 크기($d_p$) 그리고 연속상인 액체의 나선 유도흐름 액체량의 비($R_s$)가 유동층 내 유동입자의 체류량 유동층 내부 열원과 유동층간의 총괄 열전달 계수에 미치는 영향을 검토하였다. 액체-입자 나선흐름 유동층에서 입자 체류량은 입자의 크기와 나선유도흐름 액체량의 비가 증가함에 따라서 증가하였으나, 액체유속의 증가에 따라서는 감소하였다. 유동층 내부에서 나선 유도 흐름 액체량의 비가 0.1~0.3인 경우에 유동 입자의 국부체류량은 유동층 중심부에서 큰 값을 나타내었으나, $R_s$의 값이 0.5일 때는 반경 방향 입자 체류량은 거의 균일한 분포를 보이며, $R_s$의 값이 0.7일 때는 유동층 중심부의 입자 체류량이 상대적으로 감소하는 경향을 나타내었다. 유동층 내부열원과 유동층간의 열전달 특성은 열원 표면과 유동층간의 온도차 요동 자료의 위상공간 투영과 kolmogorov 엔트로피 해석으로 고찰할 수 있었으며, 나선 유도 흐름 액체량의 비($R_s$)가 0.1에서 0.5까지 증가할수록 온도차 요동 자료의 위상공간 투영은 점점 안정되고 규칙성이 증대되는 상태를 나타내고, kolmogorov 엔트로피 값은 감소하는 경향을 나타내었다. 열원 표면과 유동층간의 온도차 요동 자료의 kolmogorov 엔트로피 값은 액체의 유속이 증가함에 따라 최대값을 나타내었다. 열원과 유동층간의 총괄 열전달 계수는 액체유속, 층공극률, 나선 유도 흐름 액체량의 비가 증가함에 따라서 최대값을 나타내었으며, 유동 입자의 크기가 증가함에 따라 증가하였다. 내부 열원과 유동층간의 총괄 열전달 계수가 최대값을 나타낼 때의 액체의 유속 조건에서 온도차 요동자료의 kolmogorov 엔트로피의 값도 최대값을 나타내었다. 액체-입자 나선흐름 유동층에서 입자 체류량과 열전달 계수를 무차원군의 상관식으로 나타낼 수 있었다.

(O/W)/O 에멀젼형 액막을 이용한 탄화수소 혼합물의 분리 (Separation of Hydrocarbon Mixture Using (O/W)/O Emulsion Liquid Membrane)

  • 정민조;박함용;오준택;김종국;신명훈;김우식
    • 공업화학
    • /
    • 제8권5호
    • /
    • pp.763-770
    • /
    • 1997
  • (O/W)/O 에멀젼형 액막을 이용하여 비점이 비슷한 벤젠-싸이클로헥산 혼합물을 분리하였다. 액막 제조 조건이 선택도, 회수율 및 에멀젼 액적의 크기에 주는 영향을 고찰하였으며, 다단 맥동 추출탑을 이용한 연속 추출 실험을 통하여 비정상상태와 정상상태에서의 추출거동을 검토하였다. 추출실험결과 유화 교반 속도 4000rpm, Tween 80 농도 0.4%, 내유상에 대한 막상의 부피비 0.75, 연속상에 대한 분산상의 부피비 0.5, 투과시간10 분에서 선택도 및 벤젠의 회수율이 가장 좋았다. 에멀젼 액적의 크기 분포 측정 결과, 교반속도가 커질수록 또는 분산상의 microdrop holdup이 작을수록 분산상 액적의 평균크기가 작았으며, 분산상 microdrop holdup의 영향을 고려한 modified Calabrese의 식을 적용한 결과 turbulence damping constant의 값은 2.28이었다. 연속 추출 실험 결과 탑내 교반속도 300 rpm, 맥동 횟수 2 times/sec, 연속상 유속 30ml/min, 에멀젼상 유속 12.0ml/min에서 가장 좋은 추출 효과를 얻을 수 있었다.

  • PDF

Numerical convergence and validation of the DIMP inverse particle transport model

  • Nelson, Noel;Azmy, Yousry
    • Nuclear Engineering and Technology
    • /
    • 제49권6호
    • /
    • pp.1358-1367
    • /
    • 2017
  • The data integration with modeled predictions (DIMP) model is a promising inverse radiation transport method for solving the special nuclear material (SNM) holdup problem. Unlike previous methods, DIMP is a completely passive nondestructive assay technique that requires no initial assumptions regarding the source distribution or active measurement time. DIMP predicts the most probable source location and distribution through Bayesian inference and quasi-Newtonian optimization of predicted detector responses (using the adjoint transport solution) with measured responses. DIMP performs well with forward hemispherical collimation and unshielded measurements, but several considerations are required when using narrow-view collimated detectors. DIMP converged well to the correct source distribution as the number of synthetic responses increased. DIMP also performed well for the first experimental validation exercise after applying a collimation factor, and sufficiently reducing the source search volume's extent to prevent the optimizer from getting stuck in local minima. DIMP's simple point detector response function (DRF) is being improved to address coplanar false positive/negative responses, and an angular DRF is being considered for integration with the next version of DIMP to account for highly collimated responses. Overall, DIMP shows promise for solving the SNM holdup inverse problem, especially once an improved optimization algorithm is implemented.

삼상유동층에서 동력학적 기체유출 측정방법에 의한 큰 기포와 작은 기포의 체류량 특성 해석 (Analysis of Holdup Characteristics of Large and Small Bubbles in Three-Phase Fluidized Beds by using a Dynamic Gas Disengagement Method)

  • 임현오;임대호;서명재;강용;정헌;이호태
    • Korean Chemical Engineering Research
    • /
    • 제49권5호
    • /
    • pp.605-610
    • /
    • 2011
  • 내경이 0.105 m이고 높이가 2.5 m인 삼상(기체-액체-고체) 유동층에서 상대적으로 큰 기포와 작은 기포의 체류량 특성을 고찰하였다. 기체유속(0.01~0.07 m/s), 액체유속(0.01~0.07 m/s) 그리고 입자크기($0.5{\sim}3.0{\times}10^{-3}m$)가 상대적으로 큰 기포와 작은 기포의 체류량에 미치는 영향을 검토하였다. 삼상 유동층에서 이들 두 종류 기포들의 체류량은 동력학적 기체 유출 방법(Dynamic gas disengagement method)에 의해 측정된 각각 기포들에 의한 압력강하 정보로부터 정압강하법(static pressure drop method)에 의해 산출되었다. 기체조절기에 의해 조절되는 건조되고 여과된 공기와 물 그리고 밀도가 2,500 $kg/m^3$인 유리구슬을 각각 기체, 액체 및 고체유동입자로 사용하였다. 삼상유동층에서 이들 두 종류의 기포, 즉 상대적으로 큰 기포와 작은 기포들은 유동층 탑에 유입되는 기체와 액체의 흐름을 정지시킨 후 경과시간에 따른 탑 내부의 압력강하를 측정함으로써 효과적으로 조사하고 분리할 수 있었다. 이들 두 종류의 기포들은 경과시간에 따라 증가하는 압력강하의 기울기가 서로 매우 다르게 나타났다. 실험결과 상대적으로 큰 기포들의 체류량은 기체의 유속이 증가함에 따라 증가하였으나 액체의 유속이 증가함에 따라서는 감소하였다. 그러나, 이들 큰 기포의 체류량은 유동입자의 크기가 변화함에 따라 국부적인 최소값을 나타내었다. 상대적으로 작은 기포들의 체류량은 기체유속 또는 고체입자의 크기가 증가함에 따라 증가하였으나 액체의 유속이 증가함에 따라서는 약간 감소하였다. 이들 두 종류 기포들의 체류량들은 각각 본 연구의 실험 범위 내에서 조작변수들의 상관식으로 나타낼 수 있었다.

Semi-batch Jet Loop Reactor에서 연소 배가스중 CO2를 이용한 알칼리 폐수 중화 (Neutralization of Synthetic Alkaline Wastewater with CO2 in a Semi-batch Jet Loop Reactor)

  • 손민기;성호진;이제근
    • 한국연소학회지
    • /
    • 제18권2호
    • /
    • pp.17-22
    • /
    • 2013
  • In this study, we tested the absorption of $CO_2$ in combustion gas into an alkaline wastewater to simultaneously control $CO_2$ and wastewater. During the experiment, we investigated the effects of operating parameters on neutralization characteristics of the wastewater by using $CO_2$ in a bench-scale semi-batch jet loop reactor (0.1 m diameter and 1.0 m in height). The operating parameters investigated in the study are gas flow rate of 1.0-2.0 L/min, liquid recirculation flow rate of 4-32 L/min, and liquid temperature of $20-25^{\circ}C$. It was shown that the initial pH of wastewater rapidly decreased with increased gas flow rate for a given liquid recirculation flow rate. This was due to the increase in the gas holdup and the interfacial area at higher gas flow rate in the reactor. At constant gas flow rate, the time required to neutralize the wastewater initial pH of 10.1 decreased with liquid recirculation flow rate ($Q_L$), reached a minimum value in the range of $Q_L$ = 16-24 L/min, and then increased with further increase in $Q_L$. Further, the time required to neutralize the wastewater was shortened at higher temperatures.

Semi-batch Jet Loop Reactor에서 연소 배가스중 CO2를 이용한 알칼리 폐수 중화 (Neutralization of Synthetic Alkaline Wastewater with CO2 in a Semi-batch Jet Loop Reactor)

  • 손민기;성호진;이제근
    • 한국연소학회지
    • /
    • 제18권3호
    • /
    • pp.38-43
    • /
    • 2013
  • In this study, we tested the absorption of $CO_2$ in combustion gas into an alkaline wastewater to simultaneously control $CO_2$ and wastewater. During the experiment, we investigated the effects of operating parameters on neutralization characteristics of the wastewater by using $CO_2$ in a bench-scale semi-batch jet loop reactor (0.1 m diameter and 1.0 m in height). The operating parameters investigated in the study are gas flow rate of 1.0-2.0 L/min, liquid recirculation flow rate of 4-32 L/min, and liquid temperature of $20-25^{\circ}C$. It was shown that the initial pH of wastewater rapidly decreased with increased gas flow rate for a given liquid recirculation flow rate. This was due to the increase in the gas holdup and the interfacial area at higher gas flow rate in the reactor. At constant gas flow rate, the time required to neutralize the wastewater initial pH of 10.1 decreased with liquid recirculation flow rate ($Q_L$), reached a minimum value in the range of $Q_L$ = 16-24 L/min, and then increased with further increase in $Q_L$. Further, the time required to neutralize the wastewater was shortened at higher temperatures.

과학기술혁신을 위한 National Project의 성공적 정책집행의 요인 (Factors of Successful Policy Implementation in National Projects for Technology Innovation)

  • 조국현
    • 기술혁신연구
    • /
    • 제12권3호
    • /
    • pp.73-96
    • /
    • 2004
  • This research began by recognizing the development of telecommunication skill in a short period of time as one achievement of launching the national research and development (R&D) project for the diversification of telephone service and for the solution of telephone holdup rate. Under this concern, this research is focusing on searching the influential elements on successful outcome by analyzing the case of Time Division Exchange R&D Project carried out by Korea. Those variables for analyzing the case is limited to 7 definite variables, which are "willingness of policy making organization", "participation of manufacturers and buyers", "support from research and development group", "economy of operating methods and selection of machinery", "rate of technology transfer", "support from Fixer", and "quality management". Summarizing the result of analysis, in order to bring about technological innovation, knowledge creation activity leading to upward efficiency through competition and cooperation making a harmony should be done in one mechanism. I.e., launching an innovative policy should be done in an arena of competition and cooperation, where stability of implementing system is achieved, the entity of "Fixer" is an adequate operator, and competition and cooperation is efficiently managed, among where agreement on purpose and professional opinions are reflected.

  • PDF

기포탑에서 작은기포와 큰기포의 크기 구별 (Size Verification of Small and Large Bubbles in a Bubble Column)

  • 서명재;진해룡;임대호;임호;강용;전기원
    • Korean Chemical Engineering Research
    • /
    • 제50권2호
    • /
    • pp.304-309
    • /
    • 2012
  • 동력학적 기체유출방법(dynamic gas disengagement method)과 이중전기저항 탐침방법(dual electrical resistivity probe method)을 동시에 사용하여 기포탑에서 큰 기포와 작은 기포의 크기를 구별하였다. 기포탑의 일정한 운전조건에서 기포탑 내부에 체류하는 큰 기포와 작은 기포의 체류량은, 기포탑에 유입되는 기체의 유입을 차단한 후 시간의 흐름에 따른 기포탑 내부의 압력강하 변화를 측정하여 동력학적 기체유출방법에 의해 측정하였다. 기포의 크기와 빈도수는 동력학적 기체유출방법에 의해 큰 기포와 작은 기포의 체류량을 측정하는 동일한 운전조건에서 측정하였으며 이들 자료들로부터 기포의 크기에 따른 기포의 체류량을 결정하였다. 기포탑에서 큰 기포와 작은 기포의 크기결정은 동력학적 기체유출방법에 의해 얻은 큰 기포와 작은 기포의 체류량과 이중전기저항 탐침법에 의해 구한 크기의 범위를 아는 기포들의 체류량을 비교하여 결정하였다. 여과된 압축 공기와 물을 기체상과 연속액상을 사용하였으며, 기포탑의 직경은 0.102 m이고 높이는 1.5 m이었다. 기포탑에서 큰 기포와 작은 기포의 경계 크기는 4.0~5.0 mm 이었는데, 기체의 유속이 낮은 범위에서는 큰 기포와 작은 기포의 경계 크기가 5.0 mm 정도이었으나 기체의 유속이 상대적으로 큰 범위에서는 큰 기포와 작은 기포의 경계 크기가 4.0 mm 정도가 되었다.

기포탑 반응기에서 조작변수가 meta 붕산 생성반응 전환율에 미치는 영향 (Effects of Operating Variables on the Conversion of Meta Boric Acid Formation in a Bubble Column Reactor)

  • 조수행;도재범;강용
    • 공업화학
    • /
    • 제7권3호
    • /
    • pp.573-579
    • /
    • 1996
  • 공업적 기포탑 반응기의 설계, scale-up, 조절, 개발 및 운전에 매우 긴요한 기초자료들을 얻기 위하여 실험 실적 규모의 기포탑 반응기에서 각 실험변수들이 ortho 붕산으로부터 meta 붕산의 생성 반응전환율에 미치는 영향을 연구하였다. 반응시간 및 압력, 반응물의 입자크기 및 기체 유속 등을 실험변수로 선택하였으며, 이들 실험변수들이 기포탑 반응기내의 기체 체류량에 미치는 영향들을 반응의 전환율과 연계하여 또한 검토하였다. 연구의 결과, 다음과 같은 최적 반응조건을 얻을 수 있었다 : 반응시간 ; 35~40(분), 반응압력 ; 92~95(kPa), 반응입자의 크기 ; $0.6{\times}10^{-3}(m)$ 이하, 기체 유속 ; 0.07~0.08(m/s).

  • PDF