• Title/Summary/Keyword: Holding Power

Search Result 280, Processing Time 0.032 seconds

Structural and Physicochemical Properties of Dried Aloe Vera Gel Using DIS (Dewatering & Impregnation Soaking) Process (삼투탈수 알로에 건조제품의 구조적 및 물리화학적 특성)

  • Kim, Sung-A;Baek, Jin-Hong;Lee, Shin-Young
    • Food Engineering Progress
    • /
    • v.13 no.1
    • /
    • pp.24-31
    • /
    • 2009
  • The structural and physicochemical properties of dried aloe vera gel by DIS (dewatering impregnation soaking) process under optimum conditions were investigated. FT-IR spectra for dried samples of DIS aloes showed the typical patterns of standard aloe polysaccharide, and surface structures by SEM (scanning electron microscopy) were similar to a gel-like structure. In case of physicochemical properties of dried aloe samples by DIS process, solubilities and swelling powers of control (not osmotic treated aloe), DIS (S) and DIS (G), samples treated by osmotic solution of 60% sucrose/0.25% NaCl and 50% glucose/0.5% NaCl, were 48.3-57.3% and 8.3-11.7%, respectively, showing no significant differences among samples, but swelling power of DIS (PEG), sample treated by using 50% polyethylene glycol as an osmotic agent was about 5 times higher that of control. Also, water holding capacities of control, DIS (S) and DIS (G) were similar to each other, but that of DIS (PEG) was about 5 times higher that of control. Oil holding capacities of control and DIS aloes maintained the 50.9-86.4% levels of water holding capacities showing no significant differences among samples. Rehydration ratio of DIS (PEG) aloes were significantly dependent on the temperature of rehydrated solvent (water), and rehydration ratio of not-fileted aloe was about two folds higher than that of fileted aloe.

Structural stability analysis of jellyfish blocking net using numerical modeling (수치모델링을 활용한 해파리 차단 그물의 안정성 해석)

  • LEE, Gun-Ho
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.58 no.1
    • /
    • pp.19-31
    • /
    • 2022
  • Damages by jellyfish are occurring frequently around the world. Among them, accidents caused by jellyfish stings are serious enough to cause death. So we designed a jellyfish blocking net and analyzed its stability to prevent sting caused by jellyfish entering the beach. To this end, the dynamic behavior of the jellyfish blocking net according to the current speed (0.25-1.0 m/s) and the net type (50, 100 and 150 mm) on the upper part of the blocking net was modeled using the mass spring model. As a result of simulations for the model, the horizontal tension (horizontal component of the mooring tension) of the mooring line increased with the decrease in the mesh size on the upper part of the blocking net at all current speeds, but exceeded the holding force at high tides faster than 0.5 m/s and exceeded the holding force at all current speeds at low tide. Therefore, the jellyfish blocking nets showed poor stability overall. The depth of the float line had a little difference according to the upper mesh size and increased lineary proportional to the current speed. However, the float line sank too much to block the incoming jellyfish. These analysis results helped us find ways to improve the stability of the jellyfish blocking net, such as adjusting the length of the mooring line and improving the holding power. Therefore, it is expected that this technology will be applied us various underwater structures to discover the weaknesses of the structures and contribute to increasing the stability in the future.

Effect of Hot Isostatic Pressing on Elimination of Internal Defects in IN738LC Superalloy for Gas Turbine Blade (HIP 처리에 의한 가스터빈 블레이드용 IN738LC 초합금의 내부결함 소멸 효과)

  • Park, Young-Kyu;Kim, Soo-Hyung;Kim, Jae-Cheol;Lee, Young-Chan;Kim, Doo-Soo;Choi, Cheol;Kim, Gil-Moo
    • Journal of Korea Foundry Society
    • /
    • v.19 no.5
    • /
    • pp.427-432
    • /
    • 1999
  • Most investment castings contain some porosities and microcavities. In this study, we investigated the elimination trends of various internal defects in IN738LC investment castings for industrial gas turbine blade by hot isostatic pressing. The results showed that cylindrical defects which are under $0.6mm{\Phi}{\times}7mm$ size are mostly eliminated and aspect ratio of defects is more sensitive factor than their cross section shape in removing these defects. Increasing hot isostatic pressure and holding time doesn't affect the elimination trend of cylindrical defects over $0.6mm{\Phi}{\times}7mm$ size because first step(plastic deformation) of HIP densification doesn't occur under these HIPping conditions.

  • PDF

Influence of Frequency on Electromagnetic Field of Super High-Speed Permanent Magnet Generator

  • Qiu, Hongbo;Wei, Yanqi;Wang, Wei;Tang, Bingxia;Zhao, Xifang;Yang, Cunxiang
    • Journal of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.980-988
    • /
    • 2019
  • When compared with traditional power frequency generators, the frequency of a super high-speed permanent magnet generator (SHSPMG) is a lot higher. In order to study the influence of frequency on the electromagnetic field of SHSPMGs, a 60000rpm, 117kW SHSPMG was taken as a research object. The two-dimensional finite element model of the generator was established, and the two-dimensional transient field of the generator was simulated. In addition, a test platform of the generator was set up and tested. The reliability of the simulation was verified by comparing the experiment data with that of the simulation. Then the generator electromagnetic field under different frequencies was studied, and the influence mechanism of frequency on the generator electromagnetic field was revealed. The generator loss, voltage regulation rate, torque and torque ripple were analyzed under the rated active power load and different frequencies. The influences of frequency on the eddy current density, loss, voltage regulation rate and torque ripple of the generator were obtained. These conclusions can provide some reference for the design and optimization of SHSPMGs.

Studies on the Pulmonary Functions of the Korean Adolescents (한국인(韓國人) 청소년(靑少年)에 대(對)한 폐기능(肺機能)에 관한(關) 연구(硏究))

  • Shim, Dong-Won;Yoon, Pyung-Jin
    • The Korean Journal of Physiology
    • /
    • v.10 no.2
    • /
    • pp.17-21
    • /
    • 1976
  • In Pulmonary functions which is important Place which national physical power, especially, in under growth course whom aged from 13 to 16 young boys that whole members of 207 person, and had taken pulmonary functions eyamination record, and took as the following results. 1) Frequency of breathing: Pertaingof the frequency of breathing are 18 times per minute at boys and girls whom age is 13.41 (primary student 6 grade), and at 14.18 and with age 16.41 (middle student, & high school student) are per minute was about 16 times. 2) Vital capacity: Measures of vital capacity are in case of boy student, whom was a primary student was 3 liter, and middle student was 3.2 liter, and at high school students was 3.9 liter, and which different boys and girls student was more low quantify at girls student with comparison student. 3) Breathing holding time. Breathing holding time was nor less in boys student and with girls student, but, that prinary student which middle student and high school student was shown, that is to say, more higher age shown high quantity.

  • PDF

Analysis of a Parasitic-Diode-Triggered Electrostatic Discharge Protection Circuit for 12 V Applications

  • Song, Bo Bae;Lee, Byung Seok;Yang, Yil Suk;Koo, Yong-Seo
    • ETRI Journal
    • /
    • v.39 no.5
    • /
    • pp.746-755
    • /
    • 2017
  • In this paper, an electrostatic discharge (ESD) protection circuit is designed for use as a 12 V power clamp by using a parasitic-diode-triggered silicon controlled rectifier. The breakdown voltage and trigger voltage ($V_t$) of the proposed ESD protection circuit are improved by varying the length between the n-well and the p-well, and by adding $n^+/p^+$ floating regions. Moreover, the holding voltage ($V_h$) is improved by using segmented technology. The proposed circuit was fabricated using a $0.18-{\mu}m$ bipolar-CMOS-DMOS process with a width of $100{\mu}m$. The electrical characteristics and robustness of the proposed ESD circuit were analyzed using transmission line pulse measurements and an ESD pulse generator. The electrical characteristics of the proposed circuit were also analyzed at high temperature (300 K to 500 K) to verify thermal performance. After optimization, the $V_t$ of the proposed circuit increased from 14 V to 27.8 V, and $V_h$ increased from 5.3 V to 13.6 V. The proposed circuit exhibited good robustness characteristics, enduring human-body-model surges at 7.4 kV and machine-model surges at 450 V.

Analysis of Characteristics of Load Movement in Mobile Hydraulic Equipment (모바일 유압장치에서 부하의 유지와 내림 특성 비교)

  • Jo, Mi Hyeon;Huh, Jun Young
    • Journal of Drive and Control
    • /
    • v.15 no.4
    • /
    • pp.17-22
    • /
    • 2018
  • Mobile hydraulics require higher energy efficiency, and a simpler as well as robust design, than general industrial hydraulics. The 6/3-way directional control valve is widely used as a mobile hydraulic control valve. However, since the 6/3-way directional control valve is a spool type valve, it is difficult to maintain the load. A counterbalance valve is typically used, to maintain the load, and lift down. However, in an industrial field using a mobile hydraulics device, a pilot controlled check valve may be used to implement holding and lifting operation of the self-weight load, and a relief valve may be used simply to exert back pressure. But no comparative analysis of advantages and disadvantages of each method was revealed. In this study, various methods of holding and unloading load with self-weight in mobile hydraulics are investigated, and compared through simulation using AMESim software. This is experimentally verified by using Festo's mobile hydraulic test rig TP800.

UV-cured Pressure Sensitive Adhesive for Protective Film Application (보호필름용 자외선경화형 점착제)

  • Jamaluddin, Jamarosliza;Lee, Myung Cheon
    • Journal of Adhesion and Interface
    • /
    • v.18 no.3
    • /
    • pp.134-140
    • /
    • 2017
  • In this study, we made UV cured acrylic pressure sensitive adhesive containing silicone-urethane-acrylate (SUA) oligomer for a coating on protective film and investigated the effect of SUA oligomer content and UV-dose on adhesion properties. The results illustrated that peel strength decreases with increasing oligomer content and UV-dose, while holding power increases. The gel fractions sharply increased after UV irradiation and then remain constant with prolonged UV exposure. From peel-off test, sample S70 (70% oligomer content) shows the best peelability and removability without remaining any mark or adhesive material on the test substrate than S50 (50% oligomer content) and S60 (60% oligomer content). Sample S70 also showed a surface energy lower than $26mJ/m^2$ and a transmittance higher than 95% at UV-dose 1857 and $2270mJ/cm^2$ which met the required properties for protective film application.

A Study on the Limit of Anchor Dragging for Ship at Anchor( I ) (묘박 중인 선박의 주묘 한계에 관한 연구( I ))

  • Lee, Yun-Sok;Jung, Yun-Chul;Kim, Se-Won;Yun, Jong-Hwui;Bae, Suk-Han;Nguyen, Phung-Hung
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.29 no.1
    • /
    • pp.165-171
    • /
    • 2005
  • When typhoon approaches, ship normally drops her anchor at proper anchorage for sheltering. If an anchoring ship is under the influence of typhoon, she can keep her position when the external force and counter force is balanced. Where, external force is induced by wind, wave and tidal currents while counter force is induced by holding power of anchor/chain and thrust force of main engine. In this study, authors presented a method to analyze theoretically the limit of external force for the ship to keep her position without being dragged and, to check the validity of method, applied this to the ship which had been anchored in Jinhae Bay when the typhoon MAEMI passed on September 2003.

  • PDF

Quality Assessment of Longissimus and Semitendinosus Muscles from Beef Cattle Subjected to Non-penetrative and Penetrative Percussive Stunning Methods

  • Sazili, A.Q.;Norbaiyah, B.;Zulkifli, I.;Goh, Y.M.;Lotfi, M.;Small, A.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.26 no.5
    • /
    • pp.723-731
    • /
    • 2013
  • This study provides a comparative analysis of the effects of pre-slaughter penetrative and non-penetrative stunning and post-slaughter stunning on meat quality attributes in longissimus lumborum (LL) and semitendinosus (ST) muscles in heifers. Ten animals were assigned to each of four treatment groups: i) animals were subjected to conventional Halal slaughter (a clean incision through the structures at the front of the upper neck - the trachea, oesophagus, carotid arteries and jugular veins) and post-cut penetrating mechanical stun within 10 to 20 s of the neck cut (Unstunned; US); ii) high power non-penetrating mechanical stunning followed by the neck cut (HPNP); iii) low power non-penetrating mechanical stunning followed by the neck cut (LPNP); and iv) penetrative stunning using a captive bolt pistol followed by the neck cut (P). For each carcass, muscle samples were removed within 45 min of slaughter, portioned and analysed for pH, cooking loss, water holding capacity (WHC), tenderness (WBS), lipid oxidation (TBARS) and color, over a two week storage period. Stunning did not affect pH and cooking loss. Significant differences in water holding capacity, tenderness, lipid oxidation and color were present at different storage time points. HPNP stunning resulted in lower WHC and color values, particularly lightness ($L^*$), higher TBARS values and peak force values compared with those stunned using LPNP, P and US. These adverse effects on quality were mostly encountered in the ST muscle. In conclusion, the meat quality achieved using P, LPNP and US treatments was comparable, and no treatment stood out as considerably better than another.