• 제목/요약/키워드: Historic earthquakes

검색결과 18건 처리시간 0.018초

점성 감쇠기를 이용한 인접 비대칭 강성 구조물의 내진보강 최적설계 (Optimal Seismic Reinforcement Design of Adjacent Asymmetric-Stiffness Structures with Viscous Dampers)

  • 성은희
    • 한국안전학회지
    • /
    • 제37권6호
    • /
    • pp.60-70
    • /
    • 2022
  • This paper proposes an optimal design method of a seismic reinforcement system for the seismic performance of adjacent asymmetric-stiffness structures with viscous dampers. The first method considers plan asymmetry for efficient seismic reinforcement, and evaluates the seismic performance of optimal design applied to two cases of modeling: adjacent stiffness-asymmetric structures and adjacent stiffness-symmetric structures. The second method considers the response of asymmetric structures to derive the optimal objective function, and evaluates seismic efficiency of the objective function applied to two cases of responses: horizontal displacement and torsion. Numerical analyses are conducted on 7- and 10-story structures with a uni-asymmetric-stiffness plan using six cases of historic earthquakes, normalized to 0.4g. The results indicate that the seismic performance is excellent as modeled by adjacent asymmetric-stiffness structures and how much horizontal displacement is applied as the objective function.

원자력시설물 부지의 장기적 안전성 확보를 위한 지질구조 평가 (Evaluation on Geological Structures to Secure Long-term Safety of Nuclear Facility Sites)

  • 진광민;김영석
    • 자원환경지질
    • /
    • 제51권2호
    • /
    • pp.149-166
    • /
    • 2018
  • 전 세계적으로 대규모 지진의 발생과 이로 인한 인명피해와 재산피해는 끊임없이 발생하고 있다. 특히 일본의 동일본 대지진(M=9.0; 2011. 3. 11.)은 이로 인한 쓰나미의 발생으로 상당한 인명피해와 경제적 손실을 가져왔고, 후쿠시마 원전사고를 유발하였다. 대부분의 지진은 기존 활성단층들의 재활성에 의해 발생한다. 따라서 활성단층에 의한 지진의 재발특성을 이해하기 위한 고지진학적 연구가 활발히 수행되고 있다. 우리나라는 유라시아판 내부에 위치하여 이웃한 일본이나 대만과 같은 나라들에 비해 지진으로부터 안전지대로 여겨져 왔다. 그러나 최근 경주지진(M=5.8; 2016. 9. 12.)과 포항지진(M=5.4; 2017, 11. 15.)으로 인해 우리나라에서도 지진재해에 대한 불안감이 증가하고 있다. 특히 이 지역은 많은 원자력관련 시설물들과 대규모 산업단지가 밀집되어 있는 지역들로 지진재해로부터 극도의 안전성이 확보되어야 한다. 그러나 한반도 남동부의 경우 대규모 지진들이 제4기뿐만 아니라 역사시대에도 자주 발생한 것으로 보고되고 있다. 따라서 지진에 의한 피해를 줄이기 위해서는 활성단층을 추적하고, 활성단층을 따른 지표파열의 특성을 파악하여 해당지역에서의 지진과 단층의 거동특성을 이해하는 것이 중요하다. 이 연구에서는 극도의 안전성 확보가 필요한 원자력관련시설물들의 부지 선정을 위한 활성단층, 단층손상대, 지진과 활성단층의 상관성, 그리고 이격거리 등의 구조지질학적 평가방법을 설명하고, 이를 통해 안전한 원자력관련 시설물의 부지선정뿐만 아니라 지진재해와 방재에 유용한 정보를 제공하고자 한다.

북한 평양의 지진위험도 분석 선행연구 (A Preliminary Study of Seismic Risk in Pyongyang, North Korea)

  • 강수영;김광희
    • 암석학회지
    • /
    • 제25권4호
    • /
    • pp.325-334
    • /
    • 2016
  • 한반도에서는 크고 작은 지진이 꾸준히 발생하고 있음을 역사문헌과 계기지진 관측 자료를 통해 알 수 있다. 본 연구에서는 역사지진과 계기지진 자료를 이용해 지리정보시스템(GIS)의 공간분석 결과, 북한의 평양지역이 지진으로부터 가장 위험한 지역으로 결정되었다. 평양은 북한의 수도로서 인구와 구조물의 밀집도가 높아 지진뿐만 아니라 재해로 인해 큰 위험에 처할 수 있다. 502년 평양에서 발생한 규모 6.7의 지진을 토대로 지진동 지도를 작성한 결과, 0.24 g보다 높은 지진동을 느낄 수 있는 지역이 평양지역의 약 51.1%를 차지한다. 또한 통계청 자료에 의하면 북한은 우리나라보다 재해로부터 열악한 환경에 처해 있음을 확인할 수 있었다. 이번 연구결과는 향후 북한을 포함한 우리나라의 포괄적인 지진재해예측 연구에 유용한 정보로 사용될 수 있다.

국내 석탑의 강성, 고유진동수 및 감쇠비에 관한 연구 (Study on the Joint Stiffness, Natural Frequency and Damping Ratio of Stone Pagodas in Korea)

  • 이성민;최희수;이기학;이찬희;조영훈
    • 한국공간구조학회논문집
    • /
    • 제18권1호
    • /
    • pp.45-53
    • /
    • 2018
  • Following the earthquake that shook the city of Gyeongju, Korea, in 2016, it became apparent that research on the safety of cultural heritages against the seismic hazards is necessary in Korea. Predictions of how historically significant stone pagodas would behave the earthquakes anticipated in near future, which are the subject of this study, is also required. In this study, the dynamic characteristics of 15 cultural heritage designated stone pagodas of Korea were investigated, including natural frequency and damping ratio, and the stiffness of the stone material and its contact area were determined using eigenvalue analysis by assuming the stone pagodas to be multi-degree-of-freedom structures. The results of this study enable the structural modeling of stone pagodas using a finite element analysis program and the method is expected to be useful in assessing the structural safety of stone pagodas against vertical loads as well as lateral forces, including earthquakes. Also, by identifying the dynamic characteristics of the structures, the results of this study can be utilized as a nondestructive testing method to determine the rigidity of cultural heritage structures and to identify inherent problems. The natural frequencies of the Korean stone pagodas were measured to be within 3.5~8.3Hz, excluding cases with distinct natural frequency results, and it was determined that the natural frequencies of the stone pagodas are influenced by various parameters including the height and joint stiffness of the structures.

Pinning retrofit technique in masonry with application of polymer-cement pastes as bonding agents

  • Shrestha, Kshitij C.;Pareek, Sanjay;Suzuki, Yusuke;Araki, Yoshikazu
    • Earthquakes and Structures
    • /
    • 제5권4호
    • /
    • pp.477-497
    • /
    • 2013
  • This paper reports extensive experimental study done to compare workability and bond strength of five different types of polymer-based bonding agents for reinforcing bars in pinning retrofit. In pinning retrofit, steel pins of 6 to 10 mm diameters are inserted into holes drilled diagonally from mortar joints. This technique is superior to other techniques especially in retrofitting historic masonry constructions because it does not change the appearance of constructions. With an ordinary cement paste as bonding agent, it is very difficult to insert reinforcing bars at larger open times due to poor workability and very thin clearance available. Here, open time represents the time interval between the injection of bonding agent and the insertion of reinforcing bars. Use of polymer-cement paste (PCP), as bonding agent, is proposed in this study, with investigation on workability and bond strengths of various PCPs in brick masonry, at open times up to 10 minutes, which is unavoidable in practice. Corresponding nonlinear finite element models are developed to simulate the experimental observations. From the experimental and analytical study, the Styrene-Butadiene Rubber polymer-cement paste (SBR-PCP) with prior pretreatments of drilled holes showed strong bond with minimum strength variation at larger open times.

모달 퍼지 이론을 이용한 지진하중을 받는 구조물의 능동제어 (Active control for Seismic Response Reduction using Modal-fuzzy Approach)

  • Choi, Kang-Min;Cho, Sang-Won;Oh, Ju-Won;Lee, In-Won
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2004년도 봄 학술발표회 논문집
    • /
    • pp.409-416
    • /
    • 2004
  • An active modal-fuzzy control method using hydraulic actuators is presented for seismic response reduction. In the proposed control system, a new fuzzy controller designed in the modal space produces the desired active control force. This type controller has all advantages of the fuzzy control algorithm and modal approach. Since it is very difficult to select input variables used in fuzzy controller among an amount of state variables in the active fuzzy control system the presented algorithm adopts the modal control algorithm which is able to consider more easily information of all state variables in civil structures that are usually dominated by first few modes. In other words, all information of the whole structure can be considered in the control algorithm evaluated to reduce seismic responses and it can be efficient for especially civil structures. In addition, the presented algorithm is expected to magnify utility and performance caused by efficiency that the fuzzy algorithm can handle complex model more easily. An active modal-fuzzy control scheme is applied together with a Kalman filter and a low-pass filter to be applicable to real civil structures. A Kalman filter is considered to estimate modal states and a low-pass filter was used to eliminate spillover problem. The results of the numerical simulations far a wide amplitude range o f loading conditions and for historic earthquakes having various frequency components show that the proposed active modal-fuzzy control system can be beneficial in reducing seismic responses of civil structures.

  • PDF

베수비오 화산의 79년 분화 기록에 대한 화산학적 해석 (Volcanological Interpretation of Historic Record of AD 79 Vesuvius eruption)

  • 양은정;윤성효
    • 한국지구과학회지
    • /
    • 제44권2호
    • /
    • pp.148-160
    • /
    • 2023
  • 지구 상에서 최초로 화산 분화와 화산재해에 대한 역사기록인 '플리니 편지'를 고찰하여 베수비오 화산의 서기 79년 분화에서는 어떠한 분화 양상을 보였는지 분석하였다. 8월 24일 오전 1시에 시작된 분화는 이틀동안 지속되었고 다량의 화산재와 부석이 분출되었으며, 바람에 따라 이동하여 인근 도시들에 떨어졌다. 그 외에도 화산 측면을 따라 빠른 속도로 화성쇄설류(또는 화쇄난류)가 흘렸으며, 분화와 동반된 여러 차례의 지진과 쓰나미 등의 여러 현상들도 발생하였다. 이로 인해 베수비오 화산 인근에 위치한 도시들은 화산재와 화성쇄설류에 의해 묻혀 매몰되었다. 이에 대한 피해 범위를 폼페이, 헤르쿨라네움, 스타비아에, 오플론티스를 대상으로 선정하여 선행연구를 수집·분석하여 조사하였다. 각 지역별로 베수비오 화산과의 거리와 위치에 따라 차이가 나는 퇴적 층서와 층후를 보이고 있으며, 퇴적층 안에서는 당시 분화에 의해 사망한 주민들의 유골도 발견되었다. 현재까지 발견된 유골은 폼페이에서 1,150구, 헤르쿨라네움 306구, 스타비아에 111구, 오플론티스 54구이며, 분화로 인해 사망한 사람의 수가 정확하게 알려지지 않았다. 플리니의 편지의 상세한 분화 현상 기술로 인해 서기 79년 베수비오 화산 분화 양상을 보이는 분화를 플리니의 이름에서 착안하여 플리니안 분화라고 명명되어 새로운 분화유형으로 정의되었다.

고층 건물에 적용한 면진 시스템의 설치 위치에 따른 지진 응답 분석 (Analysis of Seismic Response According to Installation Location of Seismic Isolation System Applied to High-Rise Building)

  • 김민주;김동욱;김현수;강주원
    • 한국공간구조학회논문집
    • /
    • 제18권4호
    • /
    • pp.81-88
    • /
    • 2018
  • Seismic isolation systems have typically been used in the form of base seams in mid-rise and low-rise buildings. In the case of high-rise buildings, it is difficult to apply the base isolation. In this study, the seismic response was analyzed by changing the installation position of the seismic isolation device in 3D high - rise model. To do this, we used 30-story and 40-story 3D buildings as example structures. Historic earthquakes such as Mexico (1985), Northridge (1994) and Rome Frieta (1989) were applied as earthquake loads. The installation position of the isolation device was changed from floor to floor to floor. The maximum deformation of the seismic isolation system was analyzed and the maximum interlaminar strain and maximum absolute acceleration were analyzed by comparing the LB model with seismic isolation device and the Fixed model, which is the base model without seismic isolation device. If an isolation device is installed on the lower layer, it is most effective in response reduction, but since the structure may become unstable, it is effective to apply it to an effective high-level part. Therefore, engineers must consider both structural efficiency and safety when designing a mid-level isolation system for high-rise buildings.