• 제목/요약/키워드: Hip Rotation

검색결과 184건 처리시간 0.027초

로지스틱 회귀 분석을 이용한 고관절 내회전 각도와 단분절 요추 추간판 탈출증 발생 부위의 상관성 분석 (Analysis of the Relationship between Hip Internal Rotation Angle and the Site of Herniation of Single Level Lumbar Intervertebral Disc Using Logistic Regression)

  • 김신웅;남항우;김세준;손슬기;김종수;정재현;윤영웅;최영준;문병헌;유수빈;임한빛;김동환
    • 한방재활의학과학회지
    • /
    • 제24권4호
    • /
    • pp.117-127
    • /
    • 2014
  • Objectives The purpose of this study is to find out the relationship between the hip internal rotation angle and the site of herniation of single level lumbar intervertebral disc. Methods This study was carried out to 418 patients with lumbar disc herniation diagnosed by M.R.I, who visited Bu-Chun Jaseng Hospital of Korean Medicine with low back pain. Researchers measured their hip internal rotation angle and analyzed the relationship between the hip internal rotation angle and the site of herniation of single level lumbar intervertebral disc. Results 1. Excessive right internal rotation of hip joint increases risk of L5/S1 HIVD. 2. Limited left internal rotation of hip joint decreases risk of L4/L5 HIVD. 3. In cases of L4/L5 HIVD level, there was evidence that the prevalence of HNP in men was 1.85 times as higher than that in women. 4. In cases of L5/S1 HIVD level, there was the evidence that the prevalence of HNP in men was 0.64 times as lower than that in women. Conclusions In single-segment lumbar HIVD patients, limited left internal rotation of hip joint decreases risk of HIVD of L4/5 and excessive right internal rotation of hip joint mainly leads to L5/S1 HIVD.

계단 오르고 내리기시 엉덩관절 내회전이 무릎관절 폄근과 엉덩관절 벌림근 근활성도에 미치는 영향 (Effects of Hip Internal Rotation on Knee Extensor and Hip Abductor Electromyographic Activity During Stair Up and Down)

  • 오재섭;권오윤;이충휘;전혜선
    • 한국전문물리치료학회지
    • /
    • 제15권2호
    • /
    • pp.54-63
    • /
    • 2008
  • The purpose of this study was to examine the effect of the hip internal rotation on knee extensor and hip abductor electromyographic (EMG) activity during stair up and stair down mobility. Eighteen healthy subjects were recruited. All subjects performed stair up and down movements on a step of 30cm height while maintaining the hip in neutral (condition 1) and hip in internal rotation (condition 2). Surface EMG activity was recorded from five muscles (gluteus maximus, vastus lateralis (VL), vastus medialis oblique (VMO), posterior gluteus medius (Gmed), and tensor fascia latae (TFU)) and hip internal rotation angle was measured using a three dimensional motion analysis system The time period for stair up and down was normalized using the MatLab 6.5 program, and EMG activity was normalized to the value of maximal voluntary isometric contraction (%MVIC). The EMG activities according to the hip rotation (neutral or internal rotation) during the entire time period of stair up and down in each phase were compared using a paired t-test. During the entire period of stair up, the EMG activities of VL and TFL in condition 2 were significantly greater than in condition 1 (p<.05). During the entire period of stair down, the EMG activities of VL and TFL in condition 2 were significantly greater than in condition 1 (p<.05). However, the EMG activities of the other muscles were not significantly different between the conditions (p>.05). These results suggest that the stair up and down maintaining hip internal rotation was could be a contributing factor on patellar lateral tracking.

  • PDF

고관절 운동 프로그램이 만성 요통이 있는 아마추어 골퍼의 통증과 골프수행 수준에 미치는 즉각적인 효과 (Immediate Effect of Hip Joint Exercise Program on Low Back Pain and Performance Level in Amateur Golfers with Chronic Low Back Pain)

  • 장세희;김선엽
    • 대한물리의학회지
    • /
    • 제13권1호
    • /
    • pp.49-62
    • /
    • 2018
  • PURPOSE: This study investigated the influence of a specific hip joint exercise program on the characteristics of chronic low back pain (LBP), hip joint range of motion (ROM), and performance level in amateur golfers with LBP. METHODS: The study included 28 adult male amateur golfers with LBP and reduced internal rotation (IR) of the lead side hip joint. Subjects were randomly assigned to an experimental (EG) (n=14) or control group (CG) (n=14). The Numerical Rating Scale score for pain, ROM of the hip joint and trunk rotation, performance parameters for golfing were evaluated. A specific exercise program designed to improve IR of the lead side hip joint was performed by the EG, but not the CG. Post-intervention evaluation was performed and the collected data were analyzed. RESULTS: After the intervention, the severity of LBP was significantly reduced (p<.05) and the IR ROM of the lead side hip joint was significantly increased (p<.01) in the EG. Moreover, the trunk rotation range was significantly increased in the EG (p<.01). The drive distance was significantly difference between the EG and CG (p<.05). CONCLUSION: A specific hip joint exercise program can help to reduce pain level and improve performance level in amateur golfers with LBP and increased IR ROM of the lead side hip joint. A significant increase in ROM of the lead side hip joint reduce LBP and was related to driving distance in the EG.

엉덩관절 안쪽돌림 조절을 위한 비탄력 테이핑 방법이 엉덩관절 근활성도에 미치는 영향 -예비연구- (Effect of the Non-Elastic Taping Method of Controlling Internal Hip Joint Rotation on Hip Muscle Activity: A Preliminary Study)

  • 배송의;정주현;문동철
    • PNF and Movement
    • /
    • 제21권3호
    • /
    • pp.281-289
    • /
    • 2023
  • Purpose: This study investigated the effects of the non-elastic taping method for controlling internal hip joint rotation on internal and external hip rotator muscle activity in healthy people. Methods: In this study, 18 healthy volunteers were instructed to perform the small knee bending (SKB) test. All participants completed the test following two methods (using non-elastic taping and not using taping). Muscle activation during the two methods was measured using a surface electromyography (EMG) device. Surface EMG data were collected from the gluteus medius, gluteus maximus, and tensor fasciae femoris muscles while performing the SKB test with and without non-elastic taping. Results: Muscle activity in the gluteus maximus was significantly higher during the SKB test with non-elastic taping than during the conventional SKB test with taping (p < 0.05). Tensor fasciae latae muscle activity was lower during the SKB test with non-elastic taping than during the conventional SKB test (p < 0.05). Conclusion: The findings suggest that the non-elastic taping method for controlling internal hip joint rotation effectively activates the hip's external rotator muscles and minimizes unwanted internal rotator muscle use during the SKB test. Therefore, the non-elastic taping method for controlling internal hip joint rotation could be an effective intervention for those who cannot control the internal rotation of their hips.

A Statistical Model for Marker Position in Biomechanics

  • Kim, Jinuk
    • 한국운동역학회지
    • /
    • 제27권1호
    • /
    • pp.67-74
    • /
    • 2017
  • Objective: The purpose of this study was to apply a general linear model in statistics to marker position vectors used to study human joint rotational motion in biomechanics. Method: For this purpose, a linear model that represents the effect of the center of hip joint rotation and the rotation of the marker position on the response was formulated. Five male subjects performed hip joint functional motions, and the positions of nine markers attached on the thigh with respect to the pelvic coordinate system were acquired at the same time. With the nine marker positions, the center of hip joint rotation and marker positions on the thigh were estimated as parameters in the general linear model. Results: After examining the fitted model, this model did not fit the data appropriately. Conclusion: A refined model is required to take into account specific characteristics of longitudinal data and other covariates such as soft tissue artefacts.

주상골 하강이 하지 배열의 임상적 평가에 미치는 영향 (The Effect of Navicular Drop on The Clinical Measures of Lower Extremity Alignment)

  • 김준우;이은희;고경희;김선엽
    • 대한정형도수물리치료학회지
    • /
    • 제16권1호
    • /
    • pp.1-8
    • /
    • 2010
  • Purpose : This study aimed to examine the relationships among five clinical measures for functional alignment of the lower extremity. Methods : Thirty healthy subjects (15 males and 15 females) were recruited for the study. The five clinical measures of functional alignment of the lower extremity included navicular drop, quadriceps angle, internal rotation of hip, and anterior and lateral pelvic tilt angles. The level of navicular drop was calculated by the difference between the height of the navicular bone in the sitting (non-weight bearing) and standing (weight bearing) positions. The quadriceps angle and internal rotation of hip were measured using a standard goniometer with photographic markers while the subjects were lying in a prone position on a table with their knee at $90^{\circ}$ flexion. Anterior and lateral pelvic tilt angles were determined using a inclinometer. Results : Correlation and a simple linear regression analysis were used to assess relationships between the clinical measures. There were significant correlations between navicular drop and quadriceps angle (p<.05), between navicular drop and internal rotation of hip (p<.05), and between quadriceps angle and internal rotation of hip (p<.01). In simple linear regression analysis, the navicular drop appeared to be a factor affecting the quadriceps angle and internal rotation of hip (p<.05). The findings suggest that navicular drop has a great impact on lower extremity alignment. Conclusion : This study might help us to examine lower extremity function and clarify its role as a potential injury risk factor.

  • PDF

CT기반 3차원 모델을 이용한 고관절 운동범위 예측 (Hip Range of Motion Estimation using CT-derived 3D Models)

  • 이연수
    • 한국방사선학회논문지
    • /
    • 제12권1호
    • /
    • pp.115-122
    • /
    • 2018
  • 본 연구에서는 CT영상기반 3차원 고관절모델을 이용한 컴퓨터시뮬레이션을 통해서 고관절의 운동범위(Range of Motion)를 측정하는 방법을 제시하였다. 본 연구에서는 그 측정방법에 대한 기술적인 사항을 제시하고, 그 기술이 재현성 있게 실현할 수 있도록 대퇴골두 중심점의 결절, 대퇴골 외전(Abduction)/내전(adduction)회전축, 굽힙(flexion)/신전(extension) 회전축을 정의하고 측정하는 명확한 방법을 제시하였다. 외전각은 해부학적인 시상면(Sagittal plane)상의 Anterior-Posterior축에 대해 아래쪽(Inferior)면으로부터 Lateral 쪽으로의 회전각으로 정의된다. 최대외전각은 대퇴골두가 엉덩이뼈(Pelvis)의 절구(Acetabulum)의 테두리와 겹치지 않고 Anterior-Posterior축을 중심으로 회전할 수 있는 최대 외전각으로 결정된다. 굴곡각은 해부학적인 관상면(Coronal plane)상의 Medial-Lateral축에 대해 아래쪽(Inferior)면으로부터 회전각으로 정의된다. 최대굴곡각은 대퇴골이 Medial-Lateral축을 중심으로 엉덩이뼈(Pelvis)의 절구(Acetabulum)의 테두리와 겹치지 않고 회전할 수 있는 최대 굴곡각으로 결정된다. 정상고관절에 비해 인공고관절술을 받은 해당 환자의 경우, 외전에서는 60도 정도, 굽힘에서는 4도 정도 운동범위가 줄어들 수 있다는 예측이 나왔다. 본 연구에서 행한 시뮬레이션을 해보고 외전의 경우 운동범위의 감소가 예측되므로, 대퇴골두를 조금 큰 것을 고르거나 대퇴골목부의 길이 (femoral neck offset)를 길게 시술해야 할 필요가 있음을 의미한다.

Effects of Tensor Fasciae Latae-Iliotibial Band Self-Stretching on Lumbopelvic Movement Patterns During Active Prone Hip Lateral Rotation in Subjects With Lumbar Extension Rotation Syndrome

  • Lim, One-Bin;Yi, Chung-Hwi;Kwon, Oh-Yun;Cynn, Heon-Seock
    • 한국전문물리치료학회지
    • /
    • 제19권4호
    • /
    • pp.61-69
    • /
    • 2012
  • The purpose of this study was to identify the effects of tensor fasciae latae-iliotibial band (TFL-ITB) self-stretching exercise on the lumbopelvic movement patterns during active prone hip lateral rotation (HLR) in subjects with lumbar extension rotation syndrome accompanying TFL-ITB shortness. Eleven subjects (9 male and 2 female) were recruited for the two-week study. A three dimensional ultrasonic motion analysis system was used to measure the lumbopelvic movement patterns. The TFL-ITB length was measured using the modified Ober's test and was expressed as the hip horizontal adduction angle. The subjects were instructed how to perform TFL-ITB self-stretching exercise program at home. A paired t-test was performed to determine the significant difference in the angle of lumbopelvic rotation, movement onset time of lumbopelvic rotation, TFL-ITB length, and LBP intensity before and after the two-week period of performing the TFL-ITB self-stretching exercise. The results showed that after the intervention, the lumbopelvic rotation angle decreased significantly (p<.05), the movement onset time reduced significantly (p<.05), and LBP intensity decreased slightly but not significantly (p=.07). The hip horizontal adduction angle increased significantly (p<.05) after the intervention. These findings indicate that TFL-ITB stretching exercise increased TFL-ITB length, decreased lumbopelvic rotation angle, and delayed the movement onset time of lumbopelvic rotation after two-weeks. In conclusion, the TFL-ITB self-stretching exercise performed over a period of two weeks may be an effective approach for patients with lumbar extension rotation syndrome accompanying TFL-ITB shortness.

Effects of Counter-rotation Position on Knee/Hip Angulation, Center of Mass Inclination, and Edging Angle in Simulated Alpine Skiing

  • Yoon, Sukhoon;Kim, Jin-Hae;Park, Jae-Hyeon;Ryu, Jiseon;Park, Sang-Kyoon;Kim, Joo-Nyeon
    • 한국운동역학회지
    • /
    • 제27권2호
    • /
    • pp.91-97
    • /
    • 2017
  • Objective: To investigate rotation movement of segment for performing each position and its effect on knee/hip angulation, COM inclination, and edging angle changes. Method: Twelve Alpine skiers (age: $25.8{\pm}4.8years$, height: $173.8{\pm}5.9cm$, weight: $71.4{\pm}7.4kg$, length of career: $9.9{\pm}4.6years$) participated in this study. Each skier was asked to perform counter-rotation, neutral, and rotation positions. Results: Shank and thigh were less rotated in the counter-rotation position than in other positions, whereas the trunk and pelvis were more counter-rotated (p<.05). Hip angulation, COM inclination, and edging angle were significantly greater in the counter-rotation position than in other positions (p<.05). Conclusion: Our finding proved that the counter-rotation position increases hip angulation, COM inclination, and edging angle. Consequently, we suggest that skiers should perform counter-rotation of the trunk and pelvis relative to the ski direction in the vertical axis for the counter-rotation position. Further analysis will continue to investigate the effects of the counter-rotation position in real ski slope with kinetic analysis.

인공고관절 생체재료 마멸평가를 위한 시뮬레이터 개발 (Development of Hip Joint Simulator to Evaluate The Wear of Biomaterials Used in Total Hip Joint Replacement)

  • 이권용;윤재웅;전승범;박성길
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2001년도 제33회 춘계학술대회 개최
    • /
    • pp.265-270
    • /
    • 2001
  • Hip joint simulator which Is an essential device for evaluating the wear of biomaterials (ultrahigh molecular weight polyethylene, Co-Cr alloy, alumina, etc.) used in total hip joint replacement was developed. This hip joint simulator mimics the joint motion and joint loading of human gait by adapting the 4 degree of freedom in kinematic motion (flexing/extension, adduction/abduction, Internal rotation/external rotation) and axial loading, Four stations are operated by 8 servo-motors and harmony drives. Joint leading was imposed by displacement control from a ball screw, LM guide, and spring system. Each kinematic link system operates separately or coupled modes. A heater and a thermocouple were installed for keeping the body temperature in each station.

  • PDF