• Title/Summary/Keyword: Hip Position

Search Result 264, Processing Time 0.023 seconds

Surface Topographic Measurement Method for Assessing Lower Extremity Alignment: Examination on a novel clinical and research Tool (하지 정렬 평가를 위한 체표면 토포그래피를 이용한 측정법: 새로운 임상 및 연구 도구에 대한 검토)

  • Yim, Ji-Young;Yim, Hyun-Seung;Park, Dae-Sung;Lee, Na-Kyung;Lee, Na-Kyung
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.1
    • /
    • pp.37-45
    • /
    • 2016
  • The purpose of this study was to assess the intra-rater, inter-rater and test-retest reliability and validity of frontal plane lower extremity alignment estimated from a rasterstereographic method using ABW-Mapper. Eighteen subjects participated in this study. The S angle (stereographic angle-frontal plane lower extremity alignment estimated from a rasterstereographic method) in standing was measured throughout the two sessions with one week interval by two different readers. In the first session, a reader measured S angle twice per subject with a short break in-between. The Q-angle (quadriceps angle) was measured using a standard goniometer from a photography taken through digital camera with the participant standing in the same position as in the S angle measurement. The HKA(hip-knee-ankle) angle was measured from a computer based digital radiograph with the computerized measurement software. Reliability was tested using intraclass correlation coefficients(ICC). Validity was tested using a Pearson's correlation coefficient. Excellent intra-rater(ICC=0.956~0.974), inter-rater(ICC=0.962), test-retest reliability (ICC=0.945) were demonstrated. There were strong negative correlations between S angle and Q-angle (r=-0.739), and between S angle and HKA angle (r=-0.702). Therefore, the S angle measured using a rasterstereographic mapper may be used to as a preliminary or supplementary tool to evaluate and study LE alignment in the frontal plane in relation to HKA angle or Q-angle.

The Effect of Applying Various Tools to the Stiffness and Muscle Tone of Hamstring Muscles (다양한 도구의 적용이 뒤넙다리근의 뻣뻣함과 근 긴장도에 미치는 영향)

  • Hwang, Sunghyun;Kim, Taeho
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.4
    • /
    • pp.223-230
    • /
    • 2020
  • Purpose : The purpose of this study was to examine the effects of tools (i., extracorporeal shock wave therapy, massage gun, and foam roller) on range of motion, muscle tone and pain threshold among patients with hamstring stiffness. Methods : Fourteen participants with hamstrings stiffness were recruited. Interventions were performed 6 times, and each session was for 30 seconds using the three tools. The range of motion, muscle tone, and pain threshold were measured. The order of the use of the three tools was randomly determined. The foam roller was made to move from the bottom of the hip crease to the upper part of the back of the hamstring. Additionally, velocity 5 vibration stimulation was performed on the hamstring using a massage gun. Moreover, vibration stimulation was performed on the hamstring with extracorporeal shock wave therapy 5 minutes, 5 Hz, and 1,500 strokes. The flexibility of the posterior thigh muscle was based on maintaining the knee and hip joints in a 90 ° bend in the supine position. The joint angle of the knee was measured, when the knee was actively extended, at the maximum point where the posterior thigh muscle was stretched. The elasticity of the posterior thigh muscle was measured while the subject was prone and in a relaxed state without any force. Measurements were made at the muscle abdominal area of the semitendinosus muscle of the posterior femur, and the area to be measured was marked with a pen. The measurement of the tenderness threshold of the posterior femur was measured using a tenderness meter(Commander Algometer, J-Tech, USA). The force value at the point at which the pressure sensation change to pain was measured after applying vertical pressure to the posterior femur muscle, which was the halfway point between the ischial tuberosity and the popliteal surface of the subject lying on their stomach. Results : The extracorporeal shock wave therapy increased stiffness and, muscle tone, and caused changes in the pain threshold, whereas the other two tools had no effect on these indices. Conclusion : Extracorporeal shock wave therapy has important effects on range of motion and muscle stiffness and can be used in warmup protocols.

Analysis of Body Surface Change from 3D Scan Data of Men's Upper Bodies in Twenties - Focus on Application of Motorcycle Jacket Pattern - (3차원 인체데이터에 의한 20대 성인남성 상반신 체표변화 분석 - 모터사이클복 패턴설계시 적용을 중심으로 -)

  • Do, Wol-Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.4
    • /
    • pp.530-541
    • /
    • 2008
  • The early stage of 3D anthropometry data has been used to obtain qualitative rather than quantitative information. However recent 3D body scanners as a common research tool for anthropormatric measurments have made it possible to obtain body surface data of sufficient resolution and accuracy. The purpose of this study is finally to develop motorcycle jacket for enhanced comfort and fit, to test the accuracy and reliability of 3D measurments of motorcycle riding posture, and to analyze the change in 20's adult male's body surface measurements between the standard anthropometric position and motorcycle riding posture. The results of this study were as follows: There were no significant differences between the study and Size Korea measurments in total traditional measuring items and most of measuring items, such as length, circumference antropometric items and interscye items though not waist back length and upper arm circumference. A comparison of 3D body surface measurments in the two different measuring postures, the bodysurface measurments such as waist front length, biacromion length, front interscye, arm length, underarm length in the motorcycle riding posture decreased than that in basic posture, whereas waist back length, back interscye, C.T.W length increased. The body surface measurments such as chest, bust, upper circumference in the motorcycle riding posture decreased than that in basic posture, whereas neck, waist, hip, elbow circumference increased.

A Study on the Fatigue Phenomena of Woven Fabrics -On the Changes of Mechanical Properties and Handle of Woven Fabrics Caused by the Wearing- (직물의 피노에 관한 연구 -착용에 의한 역학적 성질과 태의 변화-)

  • Suh Young Sook
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.10 no.1
    • /
    • pp.47-57
    • /
    • 1986
  • The purpose of this study is to investigate fatigue phenomema of woven fabric. In order to obtain the basic data which is available for predicting the fabric fatigue phenomena, the change of mechanical properties of woven fabrics caused by the wearing and the changes of mechanical properties of woven fabrics which were subjected to repeated tensile-shearing deformation using fabric testing machine has been investigated and compared. The fatigue of woven fabrics was examined with the value of basic mechanical properties of specimens measured by the KES-F fabric testing system and their hand value and wearing ability. The results were as follows. 1) The fatigue phenomena of woven fabrics by the wearing for 800 hours are different on the position of the body: On the portion of hip, the change of surface property was the greatest, bending hysterisis was greatly increased, thickness weight, stiffness, fullness shearing hysterisis were more increased than original fabric and T.H.V. was decreased. On the portion of knee, decreasing of tensile resilience and increasing of bending, shearing hysterisis were observed greater than any other part, and increasing of stiffness, crispness was more than original fabric. On the bottom area, the changes of mechanical property was comparatively small, H.V. and T.H.V. showed near the value of the original fabric. 2) By drycleaning most of mechanical properties showed the tendency to recover the value of the original fabric, but bending hysterisis and thickess were increased, tensile and com-pression resilience were decreased more than original fabric in all parts. 3) The fatigue phenomena caused by fabric fatigue testing machine were as follows. The decreasing of hystersis in the repeated deformation such as bending, shearing was appeared at the $10^2$ deformation, but with the increasing cycle, the tendency was slightly regained. Handle value was also appeared the lowest value at the $10^2$ deformation.

  • PDF

The Kinetic Analysis of the Approach and Take-off Motion between Performance in Woman's High Jump (여자 높이뛰기에서 경기력 간 도움닫기와 발구름 동작의 운동역학적 분석)

  • Kim, Young-Suk;Ryu, Jae-Kyun;Jang, Jae-Kwan
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.1
    • /
    • pp.1-10
    • /
    • 2015
  • Objective : The purpose of this study was to find some kinetic variable's relationships between personal records and low records in female high jump. Methods : Collected data of the subjects(N=8, ages: $25.5{\pm}1.85$, height: $173{\pm}5.83$, mass: $54.75{\pm}6.36$ personal record: $1.71{\pm}0.04$, low record: $1.62{\pm}0.03$) were used for the last three strides and take-off phase. Five video cameras set in 30frames/s were used for recording. After digitizing motion, the Direct Linear Transformation(DLT) technique was employed to obtain 3-D position coordinates. The kinematic and kinetic factors of distance, velocity, angle, impulse, jerk variables were calculated. A paired t-test was applied for the difference of variables between personal records and lower records and for correlation with performances and variables. The significance level was accepted at p<.05. Results : There was no relationship between pattern of stride and performance. However, rate of change of velocity was related with cental of mass height(CMH) at peak point(PP). Knee, hip, backward lean, foot plant, approach and take off angle showed no difference between best record and low record. Vertical impulse momentum also showed no difference between performances. Conclusion : According to a t-test result, there were significant differences in CMH at PP and jerk at touch down between best record and low record.

Immediate Effects of Various Contract-Relax Techniques on the Peck Force and Range of Motion of Knee Extension -A Pilot Study- (수축-이완 기법 방법에 다른 최대 힘과 무릎관절 가동 범위에 미치는 즉각적인 효과 비교 -예비연구-)

  • Shin, Seung-Sub
    • PNF and Movement
    • /
    • v.16 no.2
    • /
    • pp.229-238
    • /
    • 2018
  • Purpose: This study aimed to compare the immediate effects of various contract-relax (CR) techniques on the peck force and passive range of motion (ROM) of knee extension. Methods: This study recruited 17 adult males and females who obtained below $90^{\circ}$ in straight leg raising. The subjects randomly performed one of three different CR techniques (direct CR, indirect CR, and modified CR) on the right knee extension four times per day for three days. The subjects' peck force during each CR and their passive knee extension on the hip at a $90^{\circ}$ flexed position before and after each CR were measured. Results: The peck force was significantly higher in the direct and modified CR than in the indirect CR. The ROM in the passive knee extension significantly increased after direct and indirect CR. Comparing between each CR, the passive knee extension range was significantly more improved in the direct and indirect CR than in the modified CR. Conclusion: Direct and indirect CR are more effective than modified CR in the ROM of passive knee extension. The study results suggest that the modified CR did not have the same effect on the ROM of the knee extension as the direct and indirect CR and that further research is needed to recruit more subjects and to determine the effects on different muscles after modified CR.

Development of the Nurse Uniform to Improve Nursing Service - Focused on the Summer Uniform in the General Ward - (간호업무 능률향상을 위한 간호사복 개발 - 일반병동 하복을 중심으로 -)

  • Lee, Mi Kyung;Lee, Jeong Ran
    • Journal of the Korean Society of Costume
    • /
    • v.66 no.6
    • /
    • pp.32-45
    • /
    • 2016
  • The purpose of this study is to propose changes that can be made to improve nurse uniforms in terms of outfit and functionality based on actual wearing conditions and nurse's preference. The proposed nurse uniform was composed of a blouse and pants. The design was as follows: the blouse had short set-in sleeve with China collar, a princess line, and it came down to middle hip. Armhole action pleats and back inverted pleats were embedded for convenient arm movements. The pants waist had a rubber band at the back waist, and the crotch length and the knee width were increased for activity. To make the pocket more accommodative, separate pocket slots treated with silicone were added to prevent belongings from coming out of the pocket. The pink tone of the uniforms, as well as the stripes on the blouses and spandex incorporated pants were based on nurses' preference. the nurse uniforms were produced after measuring the size of women in the age of 25 to 29, and the uniform patterns were corrected after two wearing experiments. Wearing test was examined in terms of appearance and functionality. For appearance, experts gave the uniforms a mean rating of 4.30, and nurses gave a mean rating of 4.00. Functionality was evaluated in terms of ease of activity and storage aspects. The total mean of ease of activity in nursing service was 4.30, whereas the evaluation of storage in terms of pocket position and convenience was 3.80.

Kinematic Analysis of Samdan Didimsae Movement for Jajinmori Jangdan (자진모리장단에 따른 한국무용3단 디딤새 동작에 관한 운동학적 분석)

  • Ahn, Wan-Sik
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.1
    • /
    • pp.203-212
    • /
    • 2008
  • The purpose of this study is to propose appropriate model for 3 staged Didimsae movement to Jajinmori rhythm and to provide information for ideal foot step movements. For the locational change of body center, the height of body center is lowered at the moment of forward step and during forward intersection of the feet, forward direction linear motion is converted to vertical motion to maintain stability. Speed change of body center reduces flow of body on step forward moment and controls rapid forward movement for stabled movement and position when preventing fast forward horizontal direction movement of centroid speed while knee joint and foot joint are vertically risen for heel bone contacts the ground. For angle changes of joints, in order to prevent hyperextension of lower leg, hip joint is extended and knee joint is curved to secure stability of movement for smooth curves and extension. When centroid of foot joint is moved from top of the feet to whole foot sole and when left foot makes dorsal curve, stabled movement is accomplished.

The Case Study of A Kinematic Analysis of the Right-Straight Punch in Korean National Representative Boxers (복싱 국가대표선수 라이트 스트레이트 펀치 동작의 Kinematic 특성분석-사례연구)

  • Kim, Eui-Hwan;Kim, Jin-Pyo;Lee, Jin-Wook
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.3
    • /
    • pp.293-309
    • /
    • 2003
  • The purpose of this study was to analyze the kinematic variables of the right-straight punch(RSP) in boxing with three-dimensional analysis technical methods. The subjects are boxers who have been playing in national boxing representative team and the RSP is their special favorite technique, The right-straight punches were filmed on 16mm video cameras(30frames/sec.) The kinematic variables were temporal, postural and center of gravity(COG). The mean and the standard deviation of variables have been obtained and used as basic factors for examining characteristics of the RSP by out-boxers. From the data analysis and discussion, the following conclusions have been drawn. 1) Temporal variables It is a significant characteristic that LDJ and KDM s' the amount of elapsed time(EF) needed for both an attack and a defense were similar : ET for stretch-out of attack-arm was $0.52{\pm}0.04\;sec$. and return was $0.54{\pm}0.01\;sec$. Therefore, a defense motion is as important as an attack motion. 2) Posture variables When the subjects performed a RSP, the significant characteristic of the ankle angle was that it wasn't completely returned to the original position after stretching-out. Therefore it is necessary to do supplementary exercises, such as side steps, to move the center of gravity more effectively. The hee angle was not fully stretched either. In regard to the hip angle, it should be rotated with all strength to harmonize with the direction of movement. 3) Center of Gravity(COG) variables When both LDJ and KDM performed a RSP, a significant characteristic was the transformation of sagittal view rather than transverse or frontal views.

Development of a Pattern and Visual Image for a One-Piece Dress using a 3D Virtual Clothing System (3D 가상 착의 시스템을 활용한 원피스 드레스의 원형 개발 및 시각적 이미지 연구)

  • Uh, Mi-Kyung
    • The Research Journal of the Costume Culture
    • /
    • v.19 no.3
    • /
    • pp.597-611
    • /
    • 2011
  • The purpose of this study is to propose a design method for one-piece dress patterns with high body fitness through an appearance evaluation of one-piece dress patterns with the application of the 3D Virtual Clothing System known as i-designer. Measures consisted of an optical illusion effect in visual imagery and mutual influence according to a change in the length and princess line, in a silhouette of a one-piece dress. The data was assessed by a t-test and a multi-way ANOVA and factor analysis using SPSS 17.0. The results were as follows; The design of the study pattern was done by modifying the ease of the bust circumference, ease of the abdominal circumference, ease of the hip circumference, the position of the side seam line, and the appearance of horizontality in the hem line, which received a low evaluation in appearance evaluations of a one-piece dress pattern. As a result of analyzing the visual image according to a change in the length and princess line, in the form of a silhouette of a one-piece dress, four factors were selected; the whole-body optical illusion factor, the upper-body optical illusion factor, the bust optical illusion factor, and the lower-body optical illusion factor. As a result of analyzing the effect of the interaction in the visual image according to the design variables, the influence of the main effect was found to be great in each factor. In the upper-body optical illusion factor, a significant difference was not noted in the two-way interaction between the length and the princess line. However, the influence on three-way interaction among the length, princess line, and silhouette was significant.