• Title/Summary/Keyword: Hip Fracture

Search Result 178, Processing Time 0.024 seconds

Correlation Analysis between the Factors Associated with Osteoporosis and the Fat Infiltration Rate of the Multifidus and Erector Spinae Muscles in Osteoporotic Vertebral Compression Fracture Patients (골다공증성 척추 압박 골절 환자에서 다열근과 척추기립근의 지방 침투율과 골다공증 관련 인자의 상관 관계 분석)

  • Jun, Deuk Soo;Baik, Jong-Min;Choi, Ji Uk
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.4
    • /
    • pp.318-323
    • /
    • 2020
  • Purpose: To examine the relationship between total fat infiltration (TFI) rate, which quantifies the reduction of muscles around the spine and is an important factor for sarcopenia, and the factors affecting osteoporotic vertebral compression fracture. Materials and Methods: Patients treated for osteoporotic compression fractures of the lumber spine from January 2012 to December 2016 were analyzed retrospectively. Among them, this study included ninety-eight patients who were 1) diagnosed with osteoporosis with a bone mineral density (BMD) T score of less than 2.5 g/cm2, 2) received vertebroplasty or kyphoplasty for lumbar fractures, 3) involved one segment of the lumbar spine, and 4) were followed-up for more than one year. The TFI rate confirmed by analyzing magnetic resonance imagings with the Image J program was studied. Based on this, the relationship between the TFI of the multifidus and erector spinae muscles and the factors of osteoporosis were analyzed. Results: The mean TFI of the multifidus and erector spinae was 14.66±10.16. The spine BMD showed a positive correlation with the hip BMD, but a negative correlation with the TFI. A positive correlation was observed between the hip BMD and body mass index. In addition, vitamin D was positively correlated with both the hip and spine BMD but negatively correlated with the TFI rate. Conclusion: Muscle growth helps treat osteoporosis, and can prevent fractures that occur frequently in osteoporosis patients. Increasing the vitamin intake can also slow the progression of muscle atrophy.

A Study on the Mechanical Properties of Al2O3 Cutting Tools by DLP-based 3D Printing (DLP 기반 3D 프린팅으로 제조된 Al2O3 절삭공구의 기계적 물성 연구)

  • Lee, Hyun-Been;Lee, Hye-Ji;Kim, Kyung-Ho;Kim, Kyung-Min;Ryu, Sung-Soo;Han, Yoonsoo
    • Journal of Powder Materials
    • /
    • v.26 no.6
    • /
    • pp.508-514
    • /
    • 2019
  • In the development of advanced ceramic tools, material improvements and design freedom are critical in improving tool performance. However, in the die press molding method, many factors limit tool design and make it difficult to develop innovative advanced tools. Ceramic 3D printing facilitates the production of prototype samples for advanced tool development and the creation of complex tooling products. Furthermore, it is possible to respond to mass production requirements by reflecting the needs of the tool industry, which can be characterized by small quantities of various products. However, many problems remain in ensuring the reliability of ceramic tools for industrial use. In this study, alumina inserts, a representative ceramic tool, was manufactured using the digital light process (DLP), a 3D printing method. Alumina inserts prepared by 3D printing are pressurelessly sintered under the same conditions as coupon-type specimens prepared by press molding. After sintering, a hot isostatic pressing (HIP) treatment is performed to investigate the effects of relative density and microstructure changes on hardness and fracture toughness. Alumina inserts prepared by 3D printing show lower relative densities than coupon specimens prepared by powder molding but indicate similar hardness and higher fracture toughness values.

Comparison of the Outcomes after Primary Total Hip Arthroplasty Using a Short Stem between the Modified Anterolateral Approach and Direct Anterior Approach with a Standard Operation Table (일반 수술 침대와 짧은 대퇴 주대를 이용한 인공 고관절 전 치환술의 직접 전방 도달법과 변형된 전 측방 도달법에 따른 결과 비교)

  • Park, Myung-Sik;Yoon, Sun-Jung;Choi, Seung-Min;Cho, Hong-Man;Chung, Woochull;Kang, Kyung-Rok
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.3
    • /
    • pp.244-253
    • /
    • 2019
  • Purpose: Total hip arthroplasty was performed using a direct anterior approach (DAA) on an ordinary operation table and a short femoral stem. The clinical radiographic results were evaluated by a comparison with those performed using the modified hardinge (anterolateral approach, ALA) method. Materials and Methods: From January 2013 to November 2015, 102 patients who underwent total hip arthroplasty using DAA (DAA group) and the same number of patients using ALA (ALA group), both performed by a single surgeon, were compared and analyzed retrospectively. The operation time and amounts of bleeding were compared, and the improvement in post-operative pain, ambulatory capacity and functional recovery of the hip joint were checked. The location of insertion of the acetabular cup and femoral stem were evaluated radiologically, and the complications that occurred in the two groups were investigated. Results: The amount of bleeding was significantly smaller in the DAA group (p=0.018). Up to 3 weeks postoperatively, recovery of hip muscle strength was significantly higher in the DAA group (flexion/extension strength p=0.023, abduction strength p=0.031). The Harris hip score was significantly better in the DAA group for up to 3 months (p<0.001) and the Koval score showed significantly better results in the DAA group up to 6 weeks (p≤0.001). The visual analogue scale score improvement was significantly higher in the DAA group by day 7 (p=0.035). The inclination angle (p<0.001) and anteversion angle (p<0.001) of the acetabular cup were located in the safe zone of the DAA group more than in the ALA group, and there was no statistically significant difference in the position of the femur stem and leg length difference. During surgery, two cases of greater trochanter fracture occurred in the DAA group (p=0.155). Conclusion: The DAA performed in the ordinary operation table using a short femoral stem showed post-operative early functional recovery. Because a simple to use fluoroscope was used during surgery with an anatomical position familiar to the surgeon, it is considered to be useful for the insertion of implants into the desired position and for an approach that is useful for the prevention of leg length differences.

Evaluation of the Femoral Stem Implant in Canine Total Hip Arthroplasty: A Cadaver Study

  • Cho, Hyoung Sun;Kwon, Yonghwan;Kim, Young-Ung;Kang, Jin-Su;Lee, Kichang;Kim, Namsoo;Kim, Min Su
    • Journal of Veterinary Clinics
    • /
    • v.36 no.1
    • /
    • pp.53-61
    • /
    • 2019
  • Total hip arthroplasty (THA) is a successful surgical treatment for both patients with chronical lameness and dogs who are nonresponsive to medical treatments, providing excellent joint function for returning dogs to the normal gait in 80% to 98% of hip dysplasia (HD) patients. The THA surgical implant system manufactured by BioMedtrix and Kyon are today widely accepted. When comparing the BioMedtrix biological fixation (BFX) system to the BioMedtrix cemented fixation (CFX) system, the many advantages of BFX, which include longer potential implant life, decreased risk of postoperative or later infection, and better implant stability, become evident. However, BFX implies a greater risk of femoral fracture during reaming and requires a more precise surgical technique to achieve good implant fit, given the press-fit nature of cementless THA. The purposes of this study are to both describe the mistakes and complications during stem implantation for beginner surgeons with both the BFX and the CFX systems and to document the initial result of 12 implantations in canine cadavers. Given the detailed evaluations of 3 specialists, who are Diplomate American College of Veterinary Surgeons (DACVS), only 3 of 11 stems were appropriately sized. Specifically, 6 stems were anteverted rather than being retroverted; further, although 7 stems were coaxial with the femoral long axis in the frontal plane, the other stems were in the varus at the frontal plane, with the proximal medial stem adjacent to the medial femoral cortex. Moderate angulation from the cranial to the caudal directions was found in 4 cases in the sagittal plane. Additionally, 1 case of femoral fissure and 1 case of perforated femoral cortex were reported. It is not easy for surgeons performing cementless THA for the first time to achieve a good result, even though they completed an educational course about it and given that catastrophic complications often occurred during early surgical clinical cases. Therefore, ex-vivo studies are sincerely required to get an expertise by rehearsing the preparation of the femoral envelop in isolated bones. Further studies should be conducted to achieve both highly accurate implant size and correct orientation during the preoperative planning. Additionally, surgeons' learning curve should be examined in future investigations.

Influence of porosity on the behavior of cement orthopaedic of total hip prosthesis

  • Ali, Benouis;Boualem, Serier;Smail, Benbarek
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.2 no.4
    • /
    • pp.197-206
    • /
    • 2015
  • This paper presents three-dimensional finite element method analyses of the distribution of equivalents stress of Von Mises. Induced around a cavity located in the bone cement polymethylmethacrylate (PMMA). The presences and effect of its position in the cement was demonstrated, thus on the stress level and distribution. The porosity interaction depending on their positions, and their orientations on the interdistances their mechanical behaviour of bone cement effects were analysed. The obtained results show that micro-porosity located in the proximal and distal zone of the prosthesis is subject to higher stress field. We show that the breaking strain of the cement is largely taken when the cement, containing the porosities very close adjacent to each other.

Predicted the behavior of the femur according to the loading condition using FEM (유한요소해석을 이용한 하중조건에 따른 대퇴골의 거동예측)

  • Song, Seung-Youp;Choi, Seong Dae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.4
    • /
    • pp.3-9
    • /
    • 2013
  • Falling related injuries are categorized as the most serious and common medical problems experienced by the elderly. Hip joint fracture, one of the most serious consequences of falling in the elderly, occurs in only about 1% of falling. In this study, according to the loading conditions, the analysis is the behavior of the femur. The CT images using the commercial program "Mimics" the bones of three-dimensional CAD data generated, and we will analyze the results of finite element analysis. The boundary conditions on the basis of existing research has been simplified. In this paper, the whole femur was assumed to be isotropic linear elastic material. Predicted the behavior of the femur according to the loading condition, it can be help the development of high-precision artificial bones and joints can be treated with surgery and will be able to perform efficiently.

Pulmonary Embolism after Arthroscopic Rotator Cuff Repair - A Case Report

  • Gwark, Ji Yong;Koh, Jin-Sin;Park, Hyung Bin
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.1
    • /
    • pp.31-35
    • /
    • 2014
  • Pulmonary embolism (PE) is a serious complication that can occur after orthopedic surgery. Most instances of PE in the orthopedic field have occurred after hip or knee arthroplasties or after fracture surgeries. The occurrence of PE related to arthroscopic shoulder surgery is very rare. We report a case of PE that developed after arthroscopic rotator cuff repair, in which the patient did not show preoperatively any remarkable risk factors for PE. We also review the current literature related to this topic.

Three Cases of Unusual patterns of Pyogenic Spondylitis (척추의 비전형적 감염 3례)

  • Ahn, Myun-Whan;Suh, Dae-Jin;Ahn, Jong-Chul;Ihn, Joo-Chul
    • Journal of Yeungnam Medical Science
    • /
    • v.7 no.2
    • /
    • pp.189-195
    • /
    • 1990
  • Pyogenic vertebral osteomyelitis is rare. It most commonly occurs at the lumbar area and in the fifth to seventh decades of life. Most individuals present with back pain, abdominal pain, hip pain and meningeal syndrome. We experienced three cases of unusual patterns of pyogenic osteomyelitis. The first case developed after sepsis. The second case developed after open fracture and infection of other site. The third case was misdiagnosed as metastatic cancer. We present these cases with a brief review of literatures.

  • PDF