• Title/Summary/Keyword: Higher mode

Search Result 2,340, Processing Time 0.028 seconds

A Wide-band Multi-layer Antenna Design using Double Resonance (이중공진을 사용한 적층기판용 광대역 안테나 설계)

  • Lee, Kook-Joo;Zhang, Mei-Shan;Lee, Jung-Aun;Han, Myeong-Woo;Kim, Moon-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.2
    • /
    • pp.431-434
    • /
    • 2011
  • In this paper, bandwidth enhanced design of dielectric resonator antenna fabricated in multi-layer substrate is introduced. The proposed dielectric resonator antenna is operating with fundamental TE101 mode and higher-order TM111 mode. Each resonance frequency is dependent on resonator dimensions. As increasing the height of radiating aperture, the higher-order TM111 mode resonance frequency approach the fundamental TE101 mode resonance frequency and the antenna bandwidth increase by double resonance. Three different aperture height size antennas that operated at 7GHz are fabricated in FR4 multi-layer substrate. Measured 10 dB matching bandwidth is 8 percent for single resonace antenna and 18 percent for double resonance antenna.

Dispersion Analysis of Higher-Order Modes for Planar Transmission Lines Using the 2-Dimensional Finite-Difference Time-Domain Method (2차원 유한차분-시간영역 방법을 이용한 평면형 전송선로의 고차 모드 분산 특성 해석)

  • 전중창;박위상
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.6
    • /
    • pp.847-854
    • /
    • 1999
  • In this paper, we have analysed frequency-dispersion characteristics of higher-order modes for uniform planar transmission lines, using the 2-dimensional finite-difference time-domain method. The method presented in this paper uses both informations of amplitude and phase of the electromagnetic spectrum to determine resonant frequencies, while methods previously reported use the magnitude only. This algorithm is very useful when a resonant mode has a relatively small magnitude, where the identification of the resonant mode is quite difficult. Numerical results show that a strip line supports few higher-order modes within the frequency range of 20 GHz, but there occur many higher-order modes in the structure of grounded coplanar waveguide, where resonant frequencies of the first higher-order mode is very close to those of the fundamental mode and there occur lots of very adjacent higher-order modes. As in this example, for the analysis of planar transmission lines which support many resonant modes very close each other, the method presented in this paper can be applied very efficiently.

  • PDF

Influence of higher order modes and mass configuration on the quality of damage detection via DWT

  • Vafaei, Mohammadreza;Alih, Sophia C
    • Earthquakes and Structures
    • /
    • v.9 no.6
    • /
    • pp.1221-1232
    • /
    • 2015
  • In recent decades, wavelet transforms as a strong signal processing tool have attracted attention of researchers for damage identification. Apart from the wide application of wavelet transforms for damage identification, influence of higher order modes on the quality of damage detection has been a challenging matter for researchers. In this study, influence of higher order modes and different mass configurations on the quality of damage detection through Discrete Wavelet Transform (DWT) was studied. Nine different damage scenarios were imposed to four cantilever structures having different mass configurations. The first four mode shapes of the cantilever structures were measured experimentally and analyzed by DWT. A damage index was defined in order to study the influence of higher order modes. Results of this study showed that change in the mass configuration had a great impact on the quality of damage detection even when the changes altered natural frequencies slightly. It was observed that for successful damage detection all available mode shapes should be taken into account and measured mode shapes had no significant priority for damage detection over each other.

Approximate Analysis for Shear Force Amplification Effect in Ordinary RC Shear Walls (철근콘크리트 보통전단벽의 전단력 증폭효과 근사해석)

  • Jeon, Seong-Ha;Park, Ji-Hun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.24 no.3
    • /
    • pp.129-139
    • /
    • 2020
  • An approximate analysis method is proposed to predict the dynamic amplification of shear forces in ordinary reinforced concrete shear walls as a preliminary study. First, a seismic design for three groups of ordinary reinforced concrete shear walls higher than 60 m was created on the basis of nonlinear dynamic analysis. Causes for the dynamic amplification effect of shear forces were investigated through a detailed evaluation of the nonlinear dynamic analysis result. A new modal combination rule was proposed on the basis of that observation, in which fundamental mode response and combined higher mode response were summed directly. The fundamental mode response was approximated by nonlinear static analysis result, while higher mode response was computed using response spectrum analysis for equivalent linear structural models with the effective stiffness based on the nonlinear dynamic analysis result. The proposed approximate analysis generally predicted vertical distribution of story shear and shear forces of individual walls from the nonlinear dynamic analysis with comparable accuracy.

An Investigation of Higher Order Modes in Widthwise in Parallel Plate Waveguide (평행평판 도파관에서 너비 방향으로 발생하는 고차 모드에 관한 연구)

  • Cho, Gyu-Yeong;Jo, Hyun-Dong;Park, Wee-Sang
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.6
    • /
    • pp.731-739
    • /
    • 2012
  • Transverse electric modes in parallel plate waveguide of which cut-off frequency is much lower than that of $TE_1$ and $TM_1$ mode generally known as the lowest higher order mode are investigated. Electric and magnetic field components of the modes are evaluated with the assumption that boundaries at both sides are perfect magnetic conductor. The existence of these modes are verified by simulation and experimental measurement of parallel plate waveguide cavity. Changed characteristics from the fact that the boundaries are imperfect are studied.

A Performance Estimation of Ground Source Heat Pump System Used both for Heating and Snow-melting (난방.융설 겸용 지열원 히트펌프시스템의 운전성능 평가)

  • Choi, Deok-In;Kim, Joong-Hun;Hwang, Kwang-Il
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.1
    • /
    • pp.7-12
    • /
    • 2012
  • This study proposes a hybrid geothermal system combined with heating mode and snow-melting mode for winter season in order to increase the annual operating efficiency of the GSHP(Ground Source Heat Pump). The purpose of this study is to get effectiveness of the hybrid geothermal system by the site experiments. In case of snow-melting only mode, the GSHP COP is 0.7 higher than system COP in average. And in case of hybrid mode, heating GSHP COP is 0.5 higher than snow-melting GSHP COP. And it is also found out that all COP obtained through measurement periods is higher than nominal COPs given by GSHP manufacturer. As a conclusion, it is clear that the proposed hybrid geothermal system is expected as a highly efficient system.

Hybrid Component Mode Synthesis Considering Residual Dynamic Flexibility Attachment Mode (잔여 동연성 부가 모드를 고려한 혼합 부분 모드 합성법)

  • Cha Hyun Joo;Kim Jin Ho;Lee Shi Bok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.5 s.236
    • /
    • pp.716-725
    • /
    • 2005
  • The method of substructure synthesis o. component mode synthesis(CMS) provides an effective means of dynamic analysis of very large and/or complex structures. In this study, residual dynamic flexibility attachment modes in hybrid component mode synthesis are considered for the purpose of exactly compensating the effect of higher order truncated modes. Following this way, the analysis accuracy of the synthesized structure can be improved effectively with less computational effort. In order to show the accuracy and effectiveness of the proposed hybrid component mode synthesis(HCMS), numerical experiments were carried out for the models of a clamped-clamped beam. The results verified the effectiveness of the proposed method.

Temperature effects on brittle fracture in cracked asphalt concretes

  • Ayatollahi, Majid-Reza;Pirmohammad, Sadjad
    • Structural Engineering and Mechanics
    • /
    • v.45 no.1
    • /
    • pp.19-32
    • /
    • 2013
  • Cracking at low temperatures is one of the frequently observed modes of failure in asphalt concretes. In this investigation, fracture tests were performed on cracked asphalt concrete subjected to pure mode I and pure mode II loading at different subzero temperatures. An improved semi-circular bend (SCB) specimen containing a vertical crack was used to conduct the experiments. The SCB specimens produced from the gyratory compacted cylindrical samples were compressively loaded, and critical stress intensity factors, $K_{If}$ and $K_{IIf}$, were then calculated using peak loads obtained from the tests. The experimental results showed that with decreasing the temperature, mode I and mode II critical stress intensity factors increased first but below a certain temperature they both decreased. It was also found that at a fixed temperature, the mode II fracture resistance of the asphalt concrete was higher than its mode I fracture resistance.

Improved Vertically-Aligned Nematic Mode for High Performance Displays

  • Jhun, Chul Gyu;Gwag, Jin Seog
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.6
    • /
    • pp.783-787
    • /
    • 2014
  • This paper presents an improved vertical alignment nematic liquid crystal mode characterized by the protrusions or slits of the top substrate and additional stripe type common electrodes with polarity switching of the bottom substrate to improve multi-domain vertically aligned (MVA) and patterned vertically aligned (PVA) nematic modes. MVA and PVA modes have disadvantages such as an LC disclination in the vicinity of the middle region of electrodes between the top and bottom protrusions in MVA mode or the top and bottom slits in PVA mode. Therefore, the stripe type common electrode generating a horizontal electric field and the protrusion or slit producing some pretilt of liquid crystals (LCs) were used to improve the LC disclination, which influences the transmittance and response speed. The simulation results showed that the proposed VA mode has higher transmittance than the MVA and PVA modes. As a result, the proposed VA mode can improve the response speed and transmittance remarkably, which makes it useful for upgrading the LCD display quality.

An intelligent master controller with mixed mode for teleoperation (혼합제어모드를 이용한 텔레오퍼레이션 작업용 지능형 매스터 컨트롤러)

  • 이영우;권동수
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.461-465
    • /
    • 1996
  • Position and rate control modes arc the two common modes for controlling remote manipulators with joysticks or hand controllers. Generally, position mode is easier for teleoperation than rate modes, when the manipulation work space is small or comparable to the human operator's control space. When the telemanipulator's work space is very large, human operator's control motion range must be large to allow telemanipulator's full range of motion resulting poor control resolution. One way to solve the poor resolution problem is to use indexing. However, rate mode can provide any higher degree of resolution without use of indexing. If two modes are mixed, master controller will be more convenient. The mixed mode algorithm, changes operating mode from position mode to rate mode or vise versa using fuzzy logic. The fuzzy logic algorithm, which has been designed to recognize the teleoperator's intended motion properly, provides an intelligence to a master controller.

  • PDF