• 제목/요약/키워드: High-strength rebar

검색결과 131건 처리시간 0.023초

Predicting the bond between concrete and reinforcing steel at elevated temperatures

  • Aslani, Farhad;Samali, Bijan
    • Structural Engineering and Mechanics
    • /
    • 제48권5호
    • /
    • pp.643-660
    • /
    • 2013
  • Reinforced concrete structures are vulnerable to high temperature conditions such as those during a fire. At elevated temperatures, the mechanical properties of concrete and reinforcing steel as well as the bond between steel rebar and concrete may significantly deteriorate. The changes in the bonding behavior may influence the flexibility or the moment capacity of the reinforced concrete structures. The bond strength degradation is required for structural design of fire safety and structural repair after fire. However, the investigation of bonding between rebar and concrete at elevated temperatures is quite difficult in practice. In this study, bond constitutive relationships are developed for normal and high-strength concrete (NSC and HSC) subjected to fire, with the intention of providing efficient modeling and to specify the fire-performance criteria for concrete structures exposed to fire. They are developed for the following purposes at high temperatures: normal and high compressive strength with different type of aggregates, bond strength with different types of embedment length and cooling regimes, bond strength versus to compressive strength with different types of embedment length, and bond stress-slip curve. The proposed relationships at elevated temperature are compared with experimental results.

수정압축장이론에 의한 탄소보강근-콘크리트 부재의 면내전단강도 평가 (Evaluation of In-plane Shear Strength of CFRP Rebar-Concrete Member Using Modified Compression Field Theory)

  • 강수태;양은익;최명성
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제28권4호
    • /
    • pp.13-20
    • /
    • 2024
  • 이 연구에서는 전단벽과 같은 면내 전단을 받는 경우에 대해, 종방향 보강근비를 2.96%로 일정하게 하고, 횡방향 보강근비를 0.30에서 2.98%까지 변화시켰을 때, CFRP 보강근을 사용한 콘크리트 부재의 거동특성을 MCFT 이론에 기반하여 평가하고, 철근을 사용한 콘크리트 부재의 경우와 비교하여 분석하고자 하였다. 보강근비 0.30에서 1.19% 사이에서는 CFRP 보강근을 사용한 경우가 철근을 사용한 경우보다 높은 전단강도를 보였으며, 그 이상의 1.79% 및 2.98%에서는 상대적으로 낮은 전단강도를 나타내었다. 최대전단변형률은 낮은 보강근비에서 철근을 사용한 경우가 더 크게 나타났으며, 0.97% 이상에서는 CFRP 보강근을 사용한 경우에 더 크게 나타났으며 보강근비가 커질수록 철근 대비 전단변형률 증가율이 더 크게 나타났다. 철근 및 CFRP 보강근의 기계적 성질 차이로 인해 발생하는 보강근에서의 변형률 차이 및 요소에서의 주변형률 차이 분석을 통해 보강근비 변화에 따른 철근 및 CFRP 보강근을 사용한 경우의 전단강도 및 전단변형률 변화를 비교하여 분석할 수 있었다.

GFRP로 보강된 순환골재콘크리트 블록의 성능평가 (Performance Evaluation of Recycled Aggregate Concrete Block Reinforced with GFRP)

  • 김용재;이현기;박철우;심종성
    • 한국산학기술학회논문지
    • /
    • 제14권12호
    • /
    • pp.6565-6574
    • /
    • 2013
  • 세굴방지, 하천사면보호, 하상구조물보호 등을 위해 국내에서는 프리캐스트 콘크리트 블록이 주로 사용되고 있다. 그러나 이러한 콘크리트 블록은 항상 물 또는 습윤한 환경에 접하게 되므로 내부보강재로 사용된 철근에 부식이 발생될 확률이 높으며 이로 인해 블록의 성능과 내구성이 크게 감소될 수 있다. 따라서 본 연구에서는 내부보강재를 GFRP 보강근으로 대체하여 철근부식에 따른 성능저하문제를 근본적으로 해결하고자 하였으며, 콘크리트 블록에 사용되는 콘크리트에는 순환골재와 조강시멘트를 적용하여 현장적용성을 높이고자 하였다. 실험결과 조강시멘트를 사용한 순환골재콘크리트는 기존 콘크리트에 비해 작업성과 탈형강도는 유사하였으며, 재령 28일 압축강도는 약 18% 증가되었다. 하중저항성능을 측정한 결과, GFRP 보강근이 적용된 순환골재콘크리트 블록은 기존 콘크리트 블록에 비해 약 10~30%의 하중저항성능이 향상되는 것으로 측정되었다.

철근 이음조정률의 개선을 위한 설계견적 수량과 현장시공 정산 수량의 비교분석 연구 (Comparison of the quantity estimations from the design phase and the settlement quantities of construction field to improve the extra rates of bar splice)

  • 김상연;최보미
    • 토지주택연구
    • /
    • 제8권4호
    • /
    • pp.257-266
    • /
    • 2017
  • LH has been using ultra high strength reinforcing bars (SD500 and SD600), since 2011. Such a change requires an adjustment of the old extra rates of bar splice to reflect use of ultra high strength reinforcing bars, as these rates had been set based on SD400 bars. It is particularly difficult to calculate precisely rebar lap-splice locations for large areas, such as those in apartment buildings. This research aims to adjust the extra rates of bar splice to reflect a reasonable rate; the rebar lap-splice length is not an exact estimation, but instead, an extra rates of bar splice is set and the rebar lap-splice length is increased by 2% (D 10) - 7% (025) depending on the bar size. The subjects of this study are LH apartments undergoing frame construction. We studied the quantity estimations from the design drawings, and analyzed the settlement quantities of construction field. The results of the study revealed that, when each of the quantities are analyzed, consider adjusting the extra rates of bar splice of some rebar to 1% - 3.5%. This was caused by an overuse of reinforcing bars in onsite construction and the use of supporting bars that have not been reflected in the documents, among other reasons. Based on the results of our study, an improvement plan for the current extra rates of bar splice seems to be necessary, cutting or raising the rate depending on the analysis of the data. Through this study, we expect to contribute to the calculation of reasonable construction costs, improvements in the quality of rebar work, and improvements in the capacity of design techniques for apartment buildings.

고유동 자기충전 콘크리트와 이형철근의 부착특성 (The Bond Characteristics of Deformed Bars in High Flowing Self-Compacting Concrete)

  • 최연왕;정재권;김경환;안태호
    • 대한토목학회논문집
    • /
    • 제29권5A호
    • /
    • pp.511-518
    • /
    • 2009
  • 본 연구에서는 콘크리트와 철근과의 부착강도에 영향을 미치는 요인 중 철근의 위치를 수평하부철근(Horizontal reinforcement at Bottom position, HB), 수평상부철근(Horizontal reinforcement at Top position, HT), 및 수직철근(Vertical reinforcement type, V)으로 변화시킨 시험체를 제작하여 3수준의 콘크리트 강도 변화(30, 50 및 70 MPa)에 따른 고유동 자기충전 콘크리트(High flowing Self-compacting Concrete, HSCC) 및 일반콘크리트(Conventional Concrete, CC)와 이형철근의 부착 특성을 비교 분석 하였다. HSCC 및 CC의 상부근 철근계수를 평가하기 위하여 HB/HT 철근의 부착강도비를 측정한 결과 50 및 70 MPa의 경우 HB/HT의 부착강도비는 1.3이하로 나타났으며, 30 MPa의 경우 HSCC 및 CC에서 각각 1.2 및 2.1로 나타났다. 따라서 HSCC 30, 50 및 70 MPa의 경우 콘크리트구조설계기준(2007) 정착길이 설계시 상부근 계수에 제시되는 수평상부철근에 대한 정착길이 보정계수를 CC의 1.3보다는 감소시켜 적용하는 것이 바람직할 것으로 판단된다.

Bending-shear Strength of Concrete-filled Double Skin Circular Steel Tubular Beams with SMA and Rebar in Normal-and-High-strength Concrete

  • Lee, Seung Jo;Park, Jung Min
    • Architectural research
    • /
    • 제23권1호
    • /
    • pp.11-17
    • /
    • 2021
  • A concrete-filled circular steel tube beam was fabricated, and a bending test was performed to analyze its failure modes, displacement ductility, bending-shear strength, and load-central deflection relationship. For the bending test, the installation position of the shape memory alloy (SMA) inside and outside the double-skin steel tube was used, and the rebar installation position, the concrete strength, the mixing of fibers, and the inner-outer diameter ratio as the main parameters. The test results showed that the installation positions of the reinforcements inside and outside the double-skin steel tube and the inner-outer diameter ratio of the steel tube affected the ductility, maximum load, and failure mode. In general, the specimen made of general concrete with SMA installed outside and inside (OI) the double-skin steel tube showed the best results.

초고강도 콘크리트를 활용한 고온가열 이후의 탄소 보강근과 철근의 잔류 부착성능 평가 (Evaluation of Residual Bond Stress between Carbon-fiber Reinforced Polymer and Steel Rebar Using Ultra-High-Performance-Concrete after Elevated Temperature)

  • 유선재;이호진;원천봉;윤영수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권6호
    • /
    • pp.169-176
    • /
    • 2021
  • 본 연구에서는 고온가열 이후의 탄소 보강근의 잔류 부착 강도 평가를 위하여 상온, 150℃에 따른 부착실험을 수행하였으며, 탄소 보강근과의 비교를 위한 D10 및 D13 철근도 고온 가열한 이후 잔류 부착 강도를 평가하였다. 실험 결과, 150℃ 가열 이후 탄소 보강근의 부착 강도는 상온 대비 약 9.94% 감소하였다. 반면 가열 이후 D10 철근 및 D13 철근 모두 탄소 보강근 대비 부착 강도 감소율이 적게 나타났다. 또한 온도 가열 이후 최대부착 강도에서 발생한 슬립도 탄소 보강근과 철근 모두 줄어드는 경향을 보였다. 이를 통해 고온가열에 따른 부착 강도와 슬립 감소의 상관관계를 확인하였으며, 부착-슬립 곡선을 나타내었다. 최종적으로는 실험 결괏값을 상대부착 강도로 나타냄으로써 가열 이후 탄소 보강근 및 철근의 잔류 부착성능을 확인하고자 하였다.

Pullout Test of Headed Reinforcing Bar in RC or SFRC Members with Side-Face Blowout Failure

  • Lee, Chang-Yong;Kim, Seung-Hun;Lee, Yong-Taeg
    • Architectural research
    • /
    • 제22권1호
    • /
    • pp.33-39
    • /
    • 2020
  • In this study, side-face blowout failure strength of high strength headed reinforcing bar, which is vertically anchoring between RC or SFRC members, is evaluated throughout pullout test. The major test parameters are content ratio of high strength steel fibers, strength of rebar, length of anchorage, presence of shear reinforcement, and the side concrete cover thickness planned to be 1.3 times of the rebar. In pullout test, tensile force was applied to the headed reinforcing bar with the hinged supports positioned 1.5 and 0.7 times the anchorage length on both sides of the headed reinforcing bar. As a result, the cone-shaped crack occurred where the headed reinforcing bar embedded and finally side-face blowout failure caused by bearing pressure of the headed reinforcing bar. The tensile strength of specimens increased by 13.0 ~26.2% with shear reinforcement. The pullout strength of the specimens increased by 3.6 ~15.4% according to steel fiber reinforcement. Increasing the anchoring length and shear reinforcement were evaluated to reduce the stress bearing ration of the total stress.

Seismic behavior of rebar-penetrated joint between GCFST column and RGC beam

  • Li, Guochang;Fang, Chen;An, Yuwei;Zhao, Xing
    • Steel and Composite Structures
    • /
    • 제19권3호
    • /
    • pp.547-567
    • /
    • 2015
  • The paper makes the experimental and finite-element-analysis investigation on the seismic behavior of the rebar-penetrated joint between gangue concrete filled steel tubular column and reinforced gangue concrete beam under low cyclic reversed loading. Two specimens are designed and conducted for the experiment to study the seismic behavior of the rebar-penetrated joint under cyclic loading. Then, finite element analysis models of the rebar-penetrated joint are developed using ABAQUS 6.10 to serve as the complement of the experiment and further analyze the seismic behavior of the rebar-penetrated joint. Finite element analysis models are also verified by the experimental results. Finally, the hysteretic performance, the bearing capacity, the strength degradation, the rigidity degradation, the ductility and the energy dissipation of the rebar-penetrated joint are evaluated in detail to investigate the seismic behavior of the rebar-penetrated joint through experimental results and finite element analysis results. The research demonstrates that the rebar-penetrated joint between gangue concrete filled steel tubular column and reinforced gangue concrete beam, with full and spindle-shaped load-displacement hysteretic curves, shows generally the high ductility and the outstanding energy-dissipation capacity. As a result, the rebar-penetrated joint exhibits the excellent seismic performance and meets the earthquake-resistant requirements of the codes in China. The research provides some references and suggestions for the application of the rebar-penetrated joint in the projects.

Prediction of bond strength between concrete and rebar under corrosion using ANN

  • Shirkhani, Amir;Davarnia, Daniel;Azar, Bahman Farahmand
    • Computers and Concrete
    • /
    • 제23권4호
    • /
    • pp.273-279
    • /
    • 2019
  • Corrosion of the rebar embedded in concrete has a fundamental role in the determination of life and durability of the concrete structures. Researches have demonstrated that artificial neural networks (ANNs) can effectively predict issues such as expected damage in concrete structures in marine environment caused by chloride penetration, the potential of steel embedded in concrete under the influence of chloride, the corrosion of the steel embedded in concrete and corrosion current density in steel reinforced concrete. In this study, data from different kind of concrete under the influence of chloride ion, are analyzed using the neural network and it is concluded that this method is able to predict the bond strength between the concrete and the steel reinforcement in mentioned condition with high reliability.