• Title/Summary/Keyword: High-speed imaging

검색결과 241건 처리시간 0.028초

고속 트립토판 자가형광 이미징을 위한 시공간적 집중 기반의 라인 스캐닝 이광자 현미경 개발 (Development of line-scanning two-photon microscopy based on spatial and temporal focusing for tryptophan based auto fluorescence imaging)

  • 이준호;남효석;김기현
    • 한국가시화정보학회지
    • /
    • 제11권2호
    • /
    • pp.41-45
    • /
    • 2013
  • Two-photon microscopy (TPM) is minimally-invasive 3D fluorescence microscopy based on nonlinear excitation, and TPM can visualize cellular structures based on auto-fluorescence. Line-scanning TPM is one of high-speed TPM methods without sacrificing the image resolution by using spatial and temporal focusing. In this paper, we developed line-scanning TPM based on spatial and temporal focusing for auto-fluorescence imaging by exciting the tryptophan. Laser source for this system was an optical parametric oscillator (OPO) and it made near 570 nm femtosecond pulse laser. It had 200fs pulse width and 1.72 nm bandwidth, so that the achievable depth resolution was 2.41um and field of view (FOV) is 10.8um. From the characterization, our system has 3.0 um depth resolution and 12.3 um FOV. We visualized fixed leukocyte cell sample and compared with point scanning system.

흉추에 적용한 척추교정이 피부온도와 주관적 피로에 미치는 영향 (The Changes of Skin Temperature and Subjective Fatigue of the Thoracic Vertebrae by the Chiropractic Adjustments)

  • 윤정규;이건철
    • 대한물리치료과학회지
    • /
    • 제10권1호
    • /
    • pp.102-108
    • /
    • 2003
  • The purpose of this study was to determine the changes of skin temperature and subjective fatigue of the thoracic vertebrae by the chiropractic adjustments. Stimulation of the sympathetic nervous system will cause the changes in the skin blood flow which can be detected by measuring the skin surface temperature. This study was to see whether chiropractic adjustments could affect the activity of the sympathetic nervous system as reflected by changes in skin temperature of the thoracic. Skin temperature and subjective fatigue on 16 subjects was measured before, within 10 sec, 10min, 20min and 30 min after a thoracic adjustment with Digital Infrared Thermal Imaging(DITI) and Visual Analogue Scale(VAS). The adjustments consisted of a straight posterior-to-anterior high-speed, low-amplitude thrust to the transverse process of T3-T10 using a reinforced hypothenar contact. The average temperature and fatigue changed when the spine was considered as an entire unit. These results illustrate that the blood flow through the soft tissue can be affected by specific adjustments to the spine. This study might be served as an useful baseline data for the changes of the circulation and fatigue after the chiropractic adjustments.

  • PDF

Transmission Characteristics of Indoor Infrared Diffuse Links Employing Three-Beam Optical Transmitters and Non-Imaging Receivers

  • 왕잔;반재경
    • 한국통신학회논문지
    • /
    • 제33권12A호
    • /
    • pp.1251-1260
    • /
    • 2008
  • Diffuse wireless optical communication offers more robust optical links in terms of coverage and shadowing than line-of-sight links. However, traditional diffuse wireless infrared (IR) transceiver systems are more susceptible to multi-path distortion and great power decrease, which results in limiting high-speed performance. Multi-beam is an effective technique to compensate for multi-path distortion in a wireless infrared environment. The goal of this paper is to analyze the transmission characteristics by replacing traditional diffuse system (TDS) which contains single wide angle transmitter and single element receiver by system consisting of three-beam transmitter and non-imaging receiver (TNS) attached with compound parabolic concentrator (CPC). In the simulation, we use the recursive model developed by Barry and Kahn and build the scenario based on 10 different cases which have been listed in Table 1. Moreover, we also check the reliability of the TNS diffuse link channel by BER test on the basis of different receiver positions and room sizes. The simulation results not only show the basic transmission characteristics of TNS diffuse link, but also are references to design more efficient and reliable indoor infrared transmission systems.

Aero-Optical Diagnostic Technique for the Hypersonic Boundary Layer Transition on a Flat Plate

  • Li, Ruiqu;Gong, Jian;Bi, Zhixian;Ma, Handong
    • International Journal of Aerospace System Engineering
    • /
    • 제2권2호
    • /
    • pp.6-9
    • /
    • 2015
  • A new cross disciplinary conception of transitional aero-optics is built up during analyzing and measuring the linkage between the hypersonic boundary layer transition on a flat plate and the jittering characteristics of the small-aperture beam through that boundary layer. Based on that conception, the Small-Aperture Beam Technique (SABT) and high-speed Imaging Camera System (ICS) used in aero-optical studies are considered as new techniques for the assessment of the hypersonic transition in the boundary layer on a flat plate. In the FD-20 gun tunnel, for the free stream parameters with Mach number of 8 and unit Reynolds number of $1{\times}10^7$ (1/m), those two optical techniques are used to measure the jitter of the small-aperture beam. At the same free stream parameters, the distribution of the heat transfer along the centerline of the flat plate is also measured by the thin film resistance gauge technique. The results show the similarity of the increase trend between the heat transfer and the jitter of the small-aperture beam in the transitional region. It helps us to surmise that it may be feasible to diagnose the transition in a hypersonic boundary layer on a flat plate by means of those above optical techniques.

Fast Dimming Associated with a Coronal Jet Seen in Multi-Wavelength and Stereoscopic Observations

  • 이경선;;문용재;;이진이
    • 천문학회보
    • /
    • 제37권1호
    • /
    • pp.89.1-89.1
    • /
    • 2012
  • We have investigated a coronal jet observed near the limb on 2010 June 27 by the Hinode/X-Ray Telescope (XRT), EUV Imaging Spectrograph (EIS), and Solar Optical Telescope (SOT), and the SDO/Atmospheric Imaging Assembly (AIA), Helioseismic and Magnetic Imager (HMI), and on the disk by STEREO-A/EUVI. From EUV (AIA and EIS) and soft X-ray (XRT) images we have identified both cool and hot jets. There was a small loop eruption in Ca II images of the SOT before the jet eruption. Using high temporal and multi wavelength AIA images, we found that the hot jet preceded its associated cool jet by about 2 minutes. The cool jet showed helical-like structures during the rising period. According to the spectroscopic analysis, the jet's emission changed from blue to red shift with time, implying helical motions in the jet. The STEREO observation, which enabled us to observe the jet projected against the disk, showed that there was a dim loop associated with the jet. We have measured a propagation speed of ~800 km/s for the dimming front. This is comparable to the Alfven speed in the loop computed from a magnetic field extrapolation of the HMI photospheric field measured 5 days earlier and the loop densities obtained from EIS Fe XIV line ratios. We interpret the dimming as indicating the presence of Alfvenic waves initiated by reconnection in the upper chromosphere.

  • PDF

직접 디지탈 방사선 촬영시스템과 Ektaspeed 및 Ektaspeed Plus 필름을 이용한 방사선 사진용 디지탈 영상시스템과의 비교 연구 (COMPARATIVE STUDY OF DIRECT DIGITAL RADIOGRAPHIC SYSTEM WITH FILM-BASED DIGITAL IMAGING SYSTEM USING EKTASPEED AND EKTASPEED PLUS FILM)

  • 도정주;김은경
    • 치과방사선
    • /
    • 제25권1호
    • /
    • pp.51-70
    • /
    • 1995
  • The purpose of this investigation was to compare the direct digital radiographic system with film-based digital imaging system using Ektaspeed and Ektaspeed Plus film with respect to image characteristics and detectability and evaluate the sensor noise with the use of subtraction method. Direct digital radiographic system which used was Sens-A-Ray system(Regam Medical Systems, Sundsvall, Sweden) and film-based digital imaging system was composed of Macintosh II ci computer, high resolution Sony XC-77 CCD camera and intraoral x-ray film(Kodak Ektaspeed film, Kodak Ektaspeed Plus film). Images were taken by using CCD sensor of Sens-A-Ray system, Ektaspeed film and Ektaspeed Plus film with variable exposure time(0.06s, 0.1s, 0.16s, 0.2s, 0.3s, 0.4s, 0.5s, 0.6s, O.8s, LOs), 5 times at each exposure time. And then ektaspeed films and ektaspeed plus films were digitized using CCD camera. Image groups were divided into 3 groups; Sens-A-Ray group(direct digital radiographic system), Ektaspeed group and Ektaspeed Plus group (film-based digital imaging system) They were assessed by the following three aspects; image density, image contrast and detectability and sensor noise of Sens-A-Ray system was also evaluated. The results were as follow : 1. S group showed higher density than E , EP group except at the low exposure time(p<0.01). 2. S group showed higher contrast than E,EP group except at the high exposure time(p<0.01). 3. All groups showed good detectability at the each proper exposure time. Lowest exposure time which shows maximum detectability in S,EP group(0.5s) was lower than that in E group(0.6s). 4. Sensor noise of Sens-A-Ray system generally increased according to exposure time. On the basis of the above results, it was considered that Sens-A-Ray system could show higher speed, higher contrast than Ektaspeed, Ektaspeed Plus film except at too high and low exposure time and the same detectability as the conventional intraoral film.

  • PDF

통합 센서 시스템을 이용한 고기능 순찰 로봇의 연구모델 제안 (Proposal for Research Model of High-Function Patrol Robot using Integrated Sensor System)

  • 유병천;신승중
    • 한국인터넷방송통신학회논문지
    • /
    • 제24권3호
    • /
    • pp.77-85
    • /
    • 2024
  • 본 논문에서는 열화상 카메라, 스피드돔 카메라, PTZ 카메라, 레이더, 라이다 센서와 스마트폰을 통합한 순찰 로봇을 설계하고 구현하였다. 이 로봇은 복잡한 환경에서도 효율적으로 감시하고 대응할 수 있는 능력을 갖추고 있으며, 특히 야간이나 가시성이 낮은 조건에서도 높은 성능을 발휘할 수 있도록 설계되었다. 로봇의 이동성을 위해 궤도 이동체계를 선택하였고, 실시간 데이터 처리와 의사결정을 위해 스마트폰 기반의 제어 시스템을 개발하였다. 다양한 센서의 조합은 로봇이 환경을 포괄적으로 인식하고 위험 요소를 신속하게 감지할 수 있게 해준다. 열화상 카메라는 야간 감시에, 스피드돔과 PTZ 카메라는 광범위한 영역 모니터링에, 레이더와 라이다는 장애물 탐지와 회피에 활용된다. 스마트폰 기반 제어 시스템은 사용자 친화적인 인터페이스를 제공한다. 제안된 로봇 시스템은 보안, 감시, 재난 대응 등 다양한 분야에서 활용 가능하다. 향후 연구에서는 로봇의 자율 순찰 알고리즘 개선, 다중 로봇 협업 시스템 개발, 실제 환경에서의 장기 테스트 등이 수행되어야 할 것이다. 본 연구는 지능형 감시 로봇 분야의 발전에 기여할 것으로 기대된다.

JPEG2000의 하드웨어 구현을 통한 최적 DWT 레벨의 정지영상 화질개선 (Still Image Improvement of Adaptative DWT(Discrete wavelet transform) Decomposition Level Through the Implementation of JPEG2000 Hardware)

  • 이철;유재정;이정석
    • 한국전자통신학회논문지
    • /
    • 제13권6호
    • /
    • pp.1343-1352
    • /
    • 2018
  • 본 논문은 특정응용분야인 디지털사진, 원격탐사, 이동 중 항공 원격 촬영, 의학영상의 고해상도와 고압축 원격촬영이 필요로 하는 분야에 JPEG2000의 표준을 적용한 하드웨어 설계 제작하였다. 영상 압축을 하기 위한 JPEG2000의 표준을 이용한 소프트웨어로 구현은 처리속도가 기존의 JPEG에 비하여 매우 느리다는 단점을 갖고 있으며, 또한 JPEG2000 표준의 DWT(: Discrete wavelet transform) 레벨을 향상시킬 경우 영상 데이터 압축에 대한 연산 처리 속도가 저하되는 현상을 갖고 있다. 이러한 해결을 위해서 JPEG2000 압축/복원기를 설계 제작하여 적용하였다. 본 논문에서는 최적 DWT(Discrete wavelet transform) 레벨을 변화시켜서, JPEG-2000 압축/저장기의 하드웨어가 최적의 압축과 정지 영상에 대한 빠른 연산처리속도와 화질개선을 보여줬다.

세포 이미징 기능을 겸비한 생체 유세포 분석기 (In vivo Imaging Flow Cytometer)

  • 이호
    • 한국가시화정보학회지
    • /
    • 제5권1호
    • /
    • pp.9-11
    • /
    • 2007
  • 유(流)세포분석기(flow cytometer)는 일정한 체적 내에 존재하는 세포의 종류 및 개체 수 등을 계측하는 장비로써 생체에서 추출한 유액상태(혈액 또는 림프액)의 세포를 모세관(micro-channel)을 통과시킬 때 발생하는 산란 및 형광 빛을 이용하여 계측한다. 유세포 분석기는 신약의 투석 후 세포수의 증감, 암세포의 전이 및 세포주기의 분석 등을 연구하는 데 사용되며 현재 Becton-Dickinson's 등에서 상용화된 제품을 생산 판매하고 있으며, 계측을 위해서는 생체에서 세포를 추출해야 한다는 단점을 가지고 있다. Harvard 의과대학에서 최근에 개발한 생체 유세포분석기(In vivo Flow Cytometer)는 생체에서 세포를 추출하지 않고 세포의 수를 계측할 수 있다[1]. 레이저가 혈관의 특정한 부위에 조사되고 있고, 이곳을 세포가 통과하면서 발생하는 형광을 계측함으로써 주어진 시간 동안 특정세포군이 얼마나 지나가는 지를 계측할 수 있는 장비이다. 본 특별기사에서는 혈류 가시화 분야의 독자를 위해 최근에 "Optics Express"에 "In vivo imaging flow cytometer"라는 제목으로 최근에 개제된 논문의 내용을 하여 소개한다[2].

DCE 3D Breast MRI 검사 시 30 sec 이내에 혈류 역학적 정보에 대한 연구 : Experienced Reports (A study on Hemo-Dynamic information Within 30 seconds in DCE 3D Breast MRI : Experienced Reports)

  • 구은회
    • 대한디지털의료영상학회논문지
    • /
    • 제16권1호
    • /
    • pp.27-33
    • /
    • 2014
  • The purpose of this study evaluated the hemo-dynamic information within 30 seconds clinically in 3D breast MRI. From January to March 2014, A total of 40 people were examined at 1.5 Tesla(Philips, Medical System, Achieva, The Netherlands) MRI equipments using 16 channel SENSE breast coil. The imaging parameters on vibrant are fellow as: $TR/TE/FA^{\circ}$/Matrix size/Slice thickness/Slab($5ms/2ms/10^{\circ}/180{\times}139{\times}2mm/80$). This study used a Gadovist and injected it with injection speed of 4 ml /sec by auto injector with 15 ml saline flushing. Firstly, for the delay time study, it divided three different delay time from immediately, 20 seconds, and 30 seconds. In quantitative analysis, the ROI signal intensities of tumor and surrounding tissues were measured retrospectively. In qualitative analysis, the image quality was scored from 1 to 5 point by one experienced radiological technologists as a visual test. The significance level of each delay time was evaluated with a one-way ANOVA(p<0.05). In the visual test, score levels on 30 seconds delay time was a little bit higher than others(p<0.05). The signal intensity of the tumor were $1445{\pm}360$, $1410{\pm}320$, $1510{\pm}415$ on immediately, 20 seconds, and 30 seconds and score levels were $4.18{\pm}0.85$, $3.54{\pm}0.94$, $4.45{\pm}0.74$(p<0.05). The data on immediate images showed better results than that others(p<0.05). Conclusively, Although it has been high scored in 30sec delay time for visual test in order to avoid failure in 20second, 30seconds delay time after contrast media administration, we recommend that the DCE 3D breast MRI commence immediately.

  • PDF