The purpose of this study is to present the direction of the plan to transform the residential complex into a space that can provide an open residential environment that can lead to social communication and exchange without being closed to the urban residential environment, especially in the apartment complex environment, which is becoming more dense. As a result of the Openness analysis of the 'Codan Shinonome Canal Court', the overall accessibility was good in terms of space utilization, and the openness was low in terms of the spatial composition, which is a physical environment due to the dense block type. When looking at the overall openness of the Codan Sinonome complex in terms of analysis by block, the corrected openness index (C.O.I) for all six blocks was 0.245, the corrected accessibility index (C.A.I) was 1.447 and the openness composite index (O.C.I) was assessed at 1.692. This was due to the formation of high-density block-type urban dwellings and the introduction of S-shaped streets and the layout of low-rise urban support facilities and commercial facilities. The Codan Sinonome Canal Court, which is considered an "open city residence," quantitatively confirmed that it embodies macro-space structure and human-scale space environment even in high-precision environments.
The purpose of this study is to analyze the typological characteristics of super high-rise housings in Hong Kong. The results are as follows; 1) Most of the plan types of the residential building in Hong Kong are tower types and they show lots of curves on the external resident blocks so that each resident families can face maximum open air. 2) Each residential unit is arranged symmetrically and systematically around the central core. 3) The most of core types are central core types which are usually planned to place void light well to improve lighting and ventilation. 4) Rooms are arranged in line from entrance to kitchen, to living & dinning room, and finally bedroom and bathroom. Dinning area is arranged together with living area. 5) At least, more than two sides of the each unit were facing the open air; one side is for the view from a bedroom or a livingroom, the other side is for the ventilation of a kitchen or a bathroom.
An attempt is made to illuminate the characteristics of Korean high-rise apartment plans built after the 1990s in Seoul. Unlike the typical slab block plans of the past century, these plans were accommodated in a super-highrise building which normally integrates some portion of commercial areas on the lower floors. Thus, they are much different from the pre-1990s plans, so needs to have different strategy to adapt to the Korean dwellers' domestic requirements. This study reveals the topological patterns that appear in these new plans, and tries to relate these patterns to the old configuration patterns of the slab-type apartment houses. From the analysis, it was found that some important Korean dwellers' characteristics are still preserved, but at the same time, some unprecedented patterns were beginning to be absorbed into the spatial arrangement. At the end, suggestions are made on how this emerging trend of super-high rise can be better understood and evolved to enhance the living quality in a new multi-unit setting.
Proceeding of Spring/Autumn Annual Conference of KHA
/
2004.11a
/
pp.43-48
/
2004
The purpose of this study is to analyze the typological characteristics of super high-rise housings in Hong Kong. The results are as follows; 1) The Plan types of the residential building in Hong Kong are mostly tower types and they show lots of curves on the external resident blocks so each resident families can face maximum open air. 2)Household arrangements or resident families form are shown as symmetrical and systematic type of structures that centers around the core. 3)The core types are mostly central core types and a portion of central core is planned to place void and alight garden for improving the lighting and ventilating problems. 4)If we review our room arrangements, they are arranged from entrance kitchen, livingroom bedroom to bathroom to the end. Livingrooms and dinning rooms are normally formed together. 5)If external resident blocks are facing the open air, one of the surface is on view axis, kitchen or bathroom are symmetrically located on the other side which faces the units for the purpose of ventilating.
Proceedings of the Korea Concrete Institute Conference
/
2000.10b
/
pp.1181-1186
/
2000
The crack of concrete induced by the heat of hydration is a serious problem, particularly in concrete structures such as biers, thick walls, box type walls, mat-slab of nuclear reactor buildings, dams or foundations of high rise buildings, etc.. As a result of the temperature rise and restriction condition of foundation, the thermal stress which may induce the cracks can occur. Therefore the various techniques of the thermal stress control in massive concrete have been widely used. One of them is prediction of the thermal stress, besides low-heat cement which mitigates the temperature rise, design change which considers steel bar reinforcement, operation control and so on. In this study, firstly it introduce the thermal cracks control technique by employing low-heat cement concrete, thermal stress analysis considering season. Secondly it shows the application of the cracks control technique like block placement.
Street-in-the-air has been regarded as a device which supplements the defects of high-rise blocks. It should be, however, noted that most of street-in-the-air has been based on the concept of urbanity in the automobile era as well. Based on this point of view, the 5 types of approaches to the street-in-the-air in this paper were introduced. Throughout the research, it was figured out that the types of approaches focusing the urban spatial system tended to neglect the essential properties of street itself as place for everyday life. In considering that street is defined by relationship with building or units, it is necessary to secure the correlation of street-in-the-air with units prior to considering the urban spatial system.
The objective of this study is to investigate the functional conformity based on the analysis of the spatial connectivity of block housing using space syntax. Three cases were selected which have important meanings in 1920s. The properties of spatial configuration were derived from an urban-context approach and without urban context analysis, and spatial connectivity and functional conformity were analyzed using references. The results of the study revealed that the arrangement of block housing were different from one another notwithstanding their similar layout characteristics. The relationships between urban streets and housing complexes were identified, and the public spaces were being arranged as semi-public spaces, whereas blocks as private spaces by separating functions. This study provides the implications for the planning of low rise-high density housings by means of analyzing the spatial connectivity of the spatial layout characteristics of European block housing, recognizing the relationships between urban communities and housing complexes.
Proceedings of the Korean Institute of Navigation and Port Research Conference
/
v.2
/
pp.173-177
/
2006
From the viewpoint of coastal hydrodynamics, one of the most important effects of global warming is a sea-level rise in coastal areas. In the present study, impacts on port facilities against sea-level rise were investigated. The sea-level rise causes the increase of the water depth, and it generates variations on the wave height, buoyancy, tidal system and nearshore current system and so on. The increase of water depth gives rise to the decrease of crown height of the structure and it causes increase of wave overtopping quantity. It may flood the port zone and its facilities, and may decrease harbor tranquility. It also leads to difficulties on navigation, mooring and loading/unloading at the port. Increase in water depth also causes increase of wave height in surf zone. This high wave makes structures unstable and may cause them to collapse during storm. In addition, increase in buoyant force due to sea-level rise also makes the gravity type structures unstable. Consequently, theses variations due to sea-level rise will cause functional deterioration of port facilities. In order to protect port facilities from the functional deterioration, reinforcement plan is required such as raising the crown height and increase in block weight and so on. Hence proper estimation method for the protection cost is necessary in order to protect port facilities efficiently. Moreover response strategies and integrated coastal zone management plan is required to maintain the function of port facilities. A simple estimation of cost for breakwaters in Korea was performed in the present study.
Journal of the Architectural Institute of Korea Planning & Design
/
v.35
no.10
/
pp.71-82
/
2019
This study tried to prove why a low-rise residential block is more vitalized than in a superblock consisted of an apartment housing complex. To do this, two adjacent superblocks in Yeoksam 2-dong were selected as a case study among superblocks of residential area in Gangnam, Seoul. It adopted the concept of 'complexity', 'Osmosis', 'Vitality' and 'Permeability' for evaluation indexes to measure street vitality. As a result, four indexes were clearly higher in low-density residential superblocks than apartment housing complex superblocks. First, the superblocks for apartment housing complexes showed a lower 'complexity' because large-scale parcels for an apartment housing complex reduces a possibility for various land uses. Second, smaller blocks improved "osmosis" compared to larger blocks, and the larger the block, the less likely it is that buildings and streets penetrate activity. Third, as the apartment complex block became larger, the number of accesses decreased. Thus, it did not provide vitality to the streets. Fourth, high permeability was shown in the low-density superblocks, while that of the superblock consisted of apartment housing complexes was very low because the entrance of the complexes entrance is closed to the public. The results of this study demonstrated that an apartment housing complex may hamper street vitality and deteriorate the quality of urban environments.
Presently, The Regular Block System(Automatic, Interlocking block system) is usually used during the operation of block section. However, In case that the regular block system fails because of the failure of the fixed signals and block equipment or in case of the unexpected emergency which should drive on the single line due to the accidents in the double line section or the repair work of the single line, the Substitute Block System to use the driving permission license(mapping ticket and paper) is used. In case of the operation of the opposite line and the temporary one line, the safety gets worse and the SBS may cause the fatal accidents such as a head-on & a rear-end collision. Also, the unmanned railroad stations has recently increased owing to the effective operation of the stations, for it is difficult to execute the SBS in their absence. As a result, the increase of the operation time made the train delayed. Being on the rise of these problems, in this study, we analyzed the problems and difficulties of the SBS on one line which is lacking stability and safety and on the sections combined between maned and unmaned railroad stations. And we proposed the suitable method in KORAIL referring to the examples of European & Japan railways lately. According to the passing of the high tech time, If the new SBS equipped with stability and safety is executed, it will contribute to the effective operation of trains and the satisfaction of KORAIL customers in the future.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.