• 제목/요약/키워드: High-rise Office Buildings

검색결과 87건 처리시간 0.019초

사무용 건물의 화재 대피 시뮬레이터 개발에 관한 연구 (A study on the simulator development for fire evacuation of office buildings)

  • 박양수;임동진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.543-545
    • /
    • 1999
  • In case of fire in the high-rise buildings, the appropriate and safe evacuation plans for the building residents are very important to minimize the number of casualties. Since the evacuation time usually depends on the floor plans of the buildings, the evacuation plans should be considered while the architectural design is done. Conventionally, the calculation of the evacuation time in the case of fire breakout is based on the approximate mathematical equations which are prone to error. In this study, the simulator model is developed to help the architectural designers to access the more accurate evacuation time and find out the floor plans which offers the most safe evacuation plans for the residents in case of fire.

  • PDF

첨단 태양광채광시스템의 개발현황 및 활용실태 분석에 관한 연구 (An Analysis on Development and Application of Solar Sunlighting Systems)

  • 김정태;황민구;한봉수
    • KIEAE Journal
    • /
    • 제2권1호
    • /
    • pp.63-68
    • /
    • 2002
  • Solar sunlighting systems are useful to apply for most buildings. This study aims to analysis the development and architectural application of solar sunlighting systems. For the purpose, abroad developing situation of solar sunlighting systems were investigated and analyzed literally. And, by case studies, architectural application methods are analyzed. As results, light pipe systems are mainly used for small building and houses. Also solar mirror systems are used for atrium and underground spaces. Lens-fiber systems are applied for high rise buildings and office buildings which internally have no influx of sunlighting. Some application suggestion in our country are discussed.

Shear strength formula of CFST column-beam pinned connections

  • Lee, Seong-Hui;Kim, Young-Ho;Choi, Sung-Mo
    • Steel and Composite Structures
    • /
    • 제13권5호
    • /
    • pp.409-421
    • /
    • 2012
  • Recently, as the height of building is getting higher, the applications of CFST column for high-rise buildings have been increased. In structural system of high-rise building, The RC core and exterior concrete-filled tubular (CFST) column-beam pinned connection is one of the structural systems that support lateral load. If this structural system is used, due to the minimal CFST column thickness compared to that of the CFST column width, the local moment occurred by the eccentric distance between the column flange surface from shear bolts joints degrades the shear strength of the CFST column-beam pinned connections. This study performed a finite element analysis to investigate the shear strength under eccentric moment of the CFST column-beam pinned connections. The column's width and thickness were used as variables for the analysis. To guarantee the reliability of the finite element analysis, an actual-size specimens were fabricated and tested. The yield line theory was used to formulate an shear strength formula for the CFT column-beam pinned connection. the shear strength formula was suggested through comparison on the results of FEM analysis, test and yield lime theory, the shear strength formula was suggested.

Multi-Dimensional Hybrid Design and Construction of Skyscraper Cluster -Innovative Engineering of Raffles City Chongqing-

  • Wang, Aaron J.
    • 국제초고층학회논문집
    • /
    • 제6권3호
    • /
    • pp.261-269
    • /
    • 2017
  • Designed by star architect of Moshes Safdie, Raffles City Chongqing includes a total of 6 mega high-rise towers 250 to 380 m tall, a sky conservatory, a 5-storey high shopping mall and a 3-storey basement car parking. Located at the confluence of the Yangtze and Jailing Rivers, the site for the project is imbued with a significance that is immediately symbolic, both as a sign of Chongqing's important past and as a vivid indicator of the city's thriving present and future. The design for the project to be situated at this gateway takes as its governing idea the image of powerful sails upon the water. The outer facades of the project's eight towers - the transparent surfaces that will face the water to the north - are meant to recall a fleet of ancient Chinese ships, with their huge rectangles of white canvas filled by the wind. This is a $1.13million\;m^2$ mega scale integrated project of office, retail, hotel, service residence and high-end residence with the transportation hub and traffic circulation at various levels of the project. This paper presents the multi-dimensional hybrid design, engineering and construction of this mega scale project. The innovations and the cutting-edge technology used in this project are introduced and discussed benchmarking the design and construction of the skyscraper cluster in a major city like Chongqing of China.

사무소 건물의 거주밀도 분포와 피난시간 예측 (A Occupant Load Density and Computer Modelling of Evacuation time in Office Buildings)

  • 김운형;;김홍
    • 한국화재소방학회논문지
    • /
    • 제13권3호
    • /
    • pp.35-42
    • /
    • 1999
  • 건물 화재 시 인명안전설계의 목표는 피난에 필요한 최소한의 시간을 확보하는 것이다. 본 논문에서는 적정 피난 설계를 위하여 다음과 같은 내용을 연구하였다.-국내 사무소 건물의 거주밀도 분포를 조사 분석하였다. -고층 사무소 건물에서 대피훈련을 시행하여 예상 피난시간을 관측하였다. -피난전용 프로그램의 하나인 SIMULEX를 적용하여 컴퓨터 피난모델의 특성과 적용상의 한계를 연구하였다. -거주밀도와 파난시간과의 상관성을 분석하였다. 연구 결과 국내 사무소 건물의 거주밀도는 총 바닥면적(Gross Area)기준으로 13.14$m^2$/인 -22.69$m^2$/인이며 평균 19.72$m^2$/인 (193ft\sup 2\인)으로 조사되었다. (95% 신뢰도 기준) 또한 고층 사무소 건물의 대피훈련과 SIMULEX 모델 결과를 비교하여 피난시간에 큰 차이가 나타나 현 모델의 가정과 계산 방법에 한계가 있음을 보여주었다. 한편, 거주밀도와피난시간과의 분석 결과, 동일용도에서도 차이를 보이고 있어 용도별 거주밀도 기준 마련이 시급한 것으로 판단된다.

  • PDF

Sustainable Tall Buildings: Summary of Energy-Efficient Design

  • Kheir Al-Kodmany;Mir M. Ali;Paul J. Armstrong
    • 국제초고층학회논문집
    • /
    • 제12권2호
    • /
    • pp.107-120
    • /
    • 2023
  • Tall buildings are frequently decried as unsustainable due to their excessive energy usage. Early skyscrapers used natural light and ventilation to facilitate human comfort and applied organic materials such as stone, glass, wood, concrete, and terra cotta for cladding and finishes. With the advent of fluorescent lighting, modern heating, ventilation, air-conditioning (HVAC) systems, and thermally sealed curtain walls, tall office buildings no longer had to rely on natural light and ventilation to provide comfort. Energy efficiency was not a significant factor when the operational costs of buildings were relatively inexpensive. However, today's skyscrapers must become more energy-efficient and sustainable due to energy crises and climate change. This paper highlights vital energy-efficient design principles and demonstrates with illustrative case studies how they are applied to tall buildings in various parts of the world. It shows how sustainable environmental systems do not act alone but are integrated with advanced curtain wall systems, sky gardens, and atria, among others, to regulate and sustain thermal comfort and conserve energy.

Design and Construction of GINZA KABUKIZA

  • Kawamura, Hiroshi;Ishibashi, Yoji;Morofushi, Tsutomu;Saragai, Yasuyuki;Inubushi, Akira;Yasutomi, Ayako;Fuse, Naohiko;Yoshifuku, Manabu;Saitoh, Kouji
    • 국제초고층학회논문집
    • /
    • 제5권3호
    • /
    • pp.233-241
    • /
    • 2016
  • This paper describes the structural solution for the design of a 29-story high-rise tower, which features a large office space above the Kabukiza Theatre. Kabuki is a type of Japanese traditional drama, and Kabukiza is the home building of Kabuki. GINZA KABUKIZA is the fifth generation of the Kabukiza Theatre, the first of which was built in 1889. In order to support 23 stories of office space above the theater - featuring a large void in plan - two 13-meter-deep mega-trusses, spanning 38.4 meters, are installed at the fifth floor of the building. Steelwork is used as a primary material for the structure above-ground, and a hybrid response control system using a buckling-restrained brace and oil damper is adopted in order to achieve a high seismic performance. This paper also describes the erection process of installing hydraulic jacks directly above the mega-truss at column bases, in order to keep the structure above the truss level during construction. The temple architecture of the previous Kabukiza is carefully restored by incorporating contemporary light-weight materials supported by steelwork.

Why Healthy Workplaces Matter

  • Best, Robert S.
    • 국제초고층학회논문집
    • /
    • 제6권4호
    • /
    • pp.297-300
    • /
    • 2017
  • Employers are realizing that workplaces have an immense impact on productivity. And, because people typically represent about 90% of a company's costs, even a slight improvement in productivity hits the bottom-line in a very big way. The focus is shifting away from saving money by reducing space needs or cutting energy requirements, and moving toward making the workplace friendlier and healthier. What is a healthy workplace, exactly? The answer should be clear by now. Mountains of research have expounded on this very topic, and then news outlets cover the latest discoveres ad infinitum. The problem is, research is rather dense, while the news isn't comprehensive. Office managers trying to improve workplace wellness want neither a 55-page report nor a half dozen articles to convince their landlord that their space can do better. Recognizing this gap, Harvard researchers have released a concise-yet-complete list of healthy building features. Here, we're sharing these nine features with a few insights of our own on the value of being healthy and productive. Find out: ${\bullet}$ What makes a healthy building and why is it so important ${\bullet}$ How to improve the health of your own office ${\bullet}$ What happens for your people and your bottom line when you make health a priority.

The First Performance-based Structural Fire Design for Office Building in Korea

  • Min Jae Park
    • 국제초고층학회논문집
    • /
    • 제12권3호
    • /
    • pp.235-239
    • /
    • 2023
  • In this study, the fire resistance performance of the concrete-filled steel tube (CFT) columns and thin steel-plate composite (TSC) beams installed at a 20-story office building were designed using a performance-based structural fire design. Because of the lack of any specific provisions in the building code and guidelines for structural engineers about the performance-based approach, the only prescriptive approach has been selected for designing fire-resistant structures in Korea. To evaluate the fire resistance performance of the CFT columns and TSC beams, finite element analysis verified by the experimental results studied by several researchers was conducted with ABAQUS. From the fire scenario, the temperature distributions of the CFT columns and TSC beams were found via finite element analysis and the behaviors of the CFT columns and TSC beams were investigated in the structural field based on the temperature distribution.

Strength Evaluation for Cap Plate on the Node Connection in Circular Steel Tube Diagrid System

  • Lee, Seong-Hui;Kim, Jin-Ho;Choi, Sung-Mo
    • 국제초고층학회논문집
    • /
    • 제1권1호
    • /
    • pp.21-28
    • /
    • 2012
  • Diagrid system has been in the spotlight for its superiority in terms of the resistance to lateral force when applied to skyscrapers. In diagrid system, most of columns can be eliminated because vertical loads (gravity loads) and horizontal loads (lateral loads) are delivered simultaneously thanks to the triangular shape of diagrid. However, lack of studies on connection shape and node connection details makes it hard to employ the system to the buildings. In this study, the structural safety of the node connections in circular steel tube diagrid system which has been considered in the Cyclone Tower in Korea (Seven stories below and fifty-one above the ground) was evaluated using the 4 full-scale specimens. The parameters are the extended length (20 mm, 40 mm & 60 mm), thickness (40 mm & 50 mm).