• Title/Summary/Keyword: High-rise Building

Search Result 1,780, Processing Time 0.035 seconds

Bamboo Architecture: Structure, Construction and Space: Part 1

  • Vo Trong Nghia
    • International Journal of High-Rise Buildings
    • /
    • v.13 no.2
    • /
    • pp.113-145
    • /
    • 2024
  • Bamboo is seen as a low cost, lightweight, widely available and environmental-friendly material. In Vietnam, it also connects deeply to our culture. However, it wasn't seen as a viable material for large structures before VTN Architects. Furthermore, Vietnamese cities are facing the same environmental problems as many developing metropolises in the world. Globally, climate change is a serious issue. The need for sustainable construction material is clear. The increasing development of eco-tourism in Vietnam and Asia is also a background. These become the background to the foundation and the development of bamboo architecture by VTN Architects. The journal analyses our development of bamboo construction, joints, structures, and how to use them to realise space and to create eco-friendly architecture. We will talk about our process of bamboo procurement, our construction methods, our unique joint system, how we make a frame unit and how we construct VTN bamboo structures from units.

The Thermal Analysis of Pole Mount Mold Transformer with One-body Molding by Duct Condition (일체형 주상용 몰드변압기의 덕트에 따른 열해석 특성 연구)

  • Cho, Han-Goo;Lee, Un-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1135-1138
    • /
    • 2003
  • The transformer is major equipment in power receiving and substation facilities. Necessary conditions required for the transformer are compactness, lightness, high reliability, economic advantages, and easy maintenance. The pole-mount transformer installed in distribution system is acting direct role in supply of electric power and it is electric power device should drive for long term. Most of modem transformer are oil-filled transformer and accident is happening considerable. The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss. One body molding transformer needs some cooling method because heat radiation between each winding is difficult. In this paper, The thermal analysis of pole mount mold transformer with one body molding by duct condition is investigated and the test result of temperature rise is compared with simulation data.

  • PDF

A Simplified Steel Beam-To-Column Connection Modelling Approach and Influence of Connection Ductility on Frame Behaviour in Fire

  • Shi, Ruoxi;Huang, Shan-Shan;Davison, Buick
    • International Journal of High-Rise Buildings
    • /
    • v.7 no.4
    • /
    • pp.343-362
    • /
    • 2018
  • A simplified spring connection modelling approach for steel flush endplate beam-to-column connections in fire has been developed to enable realistic behaviour of connections to be incorporated into full-scale frame analyses at elevated temperature. Due to its simplicity and reliability, the proposed approach permits full-scale high-temperature frame analysis to be conducted without high computational cost. The proposed simplified spring connection modelling approach has been used to investigate the influence of connection ductility (both axial and rotational) on frame behaviour in fire. 2D steel and 3D composite frames with a range of beam spans were modelled to aid the understanding of the differences in frame response in fire where the beam-to-column connections have different axial and rotational ductility assumptions. The modelling results highlight that adopting the conventional rigid or pinned connection assumptions does not permit the axial forces acting on the connections to be accurately predicted, since the axial ductility of the connection is completely neglected when the rotational ductility is either fully restrained or free. By accounting for realistic axial and rotational ductilities of beam-to-column connections, the frame response in fire can be predicted more accurately, which is advantageous in performance-based structural fire engineering design.

Tall Buildings as Urban Habitats: A Quantitative Approach for Measuring Positive Social Impacts of Tall Buildings' Lower Public Space

  • Zhou, Xihui;Ye, Yu;Wang, Zhendong
    • International Journal of High-Rise Buildings
    • /
    • v.8 no.1
    • /
    • pp.57-69
    • /
    • 2019
  • After decades of high-speed development, designing tall buildings as critical components of urban habitat, rather than simply standing aloof from their environments, has become an important concern in many Asian cities. Nevertheless, the lack of quantitative understanding cannot support efficient architectural design or urban renewal that targets better place-making. This study attempts to fill the gap by providing a typological approach for measuring the social impact of tall buildings' ground conditions: that is, public space, podiums, and interfaces. The central business districts (CBD) of three Asian cities, Shanghai, Hong Kong, and Singapore, were selected as cases. Typical patterns and categories of lower-level public spaces among the three CBDs were abstracted via typological analyses and field study. The following evaluation is achieved through the analytic hierarchy process (AHP). This quantified approach helps to provide a visualization of high or low positive social impacts of tall buildings' lower-level public spaces among the three cases. This study also helps to suggest a design code for tall buildings aimed at a more human-oriented urban habitat.

Study on the Ventilation System Applicability of High-rise Hog Building for Growing-fattening (고상식 육성비육돈사에 적합한 환기시스템에 관한 연구)

  • Yoo, Yong-Hee;Song, Jun-Ik;Choi, Dong-Yoon;Chung, Eui-Soo;Jeon, Kyoung-Ho;Lee, Poong-Yeon;Kim, Sang-Woo;Jeung, Jong-Won
    • Journal of Animal Environmental Science
    • /
    • v.16 no.1
    • /
    • pp.41-50
    • /
    • 2010
  • The goal of this study was to develop a suitable ventilation system for high-rise hog building (HRHB) for growing-fattening with combined slatted floor pen in second story and in situ manure management system in Korea. The HRHB was constructed as 29m long, 9m wide and 7.6m high for outer dimension with an indoor height of 3.1m and 2.4 for lower and upper floor, respectively. Ventilation systems for each treatment were installed in separated rooms of HRHB. The ventilation types installed in each room were following 3 types: ventilation type 1 (V1), where air was pulled through a circular duct inlet and exhausted by fans; ventilation type 2 (V2), where air was pulled through eave inlet (side ceiling inlet) and exhausted by fans; and ventilation type 3 (V3), where air was pulled through baffled ceiling inlet and exhausted by fans. For each ventilation system, investigated air velocity under minimum, medium and maximum ventilation ratio and air flow pattern inside. The results were as follows; For air flow pattern from top to bottom, V1 showed a homogeneous vertical type, V2 showed a bilateral symmetry type and V3 showed an vertical umbrella type. Under minimum ventilation ratio, air velocity in upper floor (80cm above the slated floor) was similar for V1, V2, and V3. Under maximum ventilation ratio, air velocity in upper floor was undeviating for V1 (0.10~0.26m/s) and varied for V2 (0.12~0.63m/s) while those for V3 was relatively slow and less varied (0.07~0.15m/s). In conclusion, Duct inlet type (V1) can be applied to the development of a new HRHB with additional evaluations such as field test hog feeding.

Development and Application of a Self Climbing Safety Fence for Construction Building (건축공사용 안전펜스 공법의 개발 및 적용)

  • Choi Min-Woo;Roh Whan-Gil;Lee Jae-Yong;Lee Hyun-Soo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.1 no.3 s.3
    • /
    • pp.108-115
    • /
    • 2000
  • The average height of buildings in most cities is increasing in an effort to more effectively use land. In addition, as construction technology develops, rapid construction methods have been pursued. However, while there have been great strides in construction technology, the development of a temporary structure that can support the high-rise building under construction and the rapid construction methods has been relatively limited. If the temporary structure is not built on an outer wall of a building being constructed, a worker may be injured or killed in a fall and building materials such as blocks and other objects may fall to the ground, causing the build-up of trash around the building and possible injuries to persons in proximity to the building. This paper proposes a Self Climbing Safety Fence for construction building(SCfence). SCfence was developed to solve the above problems, a tent has been setup to cover the outer wall of the building, or a falling preventing net has been pitched in a direction perpendicular to the outer wall of the building. A case study was performed to verify the validity of SCfence through comparing the safety and cost experience between SCfence and the existing method.

  • PDF

A Study on the Size of Buildings for Utilizing the Limit Slenderness Ratio Approximation Equation of Outrigger Structural System (아웃리거 구조시스템의 한계세장비 근사식 활용을 위한 건물규모에 대한 연구)

  • Yang, Jae-Kwang;Choi, Hyun-Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.11
    • /
    • pp.19-26
    • /
    • 2019
  • To construct buildings on limited land, the size of the building is important. The development process needs to be minimized because determining the size of a structurally safe building at the planning stage incurs considerable time and cost. This study proposes the Limit Slenderness Ratio Approximation Equation. This study examined an outrigger structure system among several systems proposed for controlling the lateral displacement in tall buildings. This study compared the Limit Slenderness Ratio Approximation Equation with the approximate equation by changing the variables of the building model, and examined the size of the building using the approximate Equation. As an analysis program, the MAIDAS architectural structural analysis program was used to conduct model-specific analysis. The appropriate scale of the building to minimize the error between the approximate value calculated by the Limit Slenderness Ratio Approximation Equation and the analysis result of the structural analysis program is as follows. As the number of outrigger installation increases, the error can be reduced; the ratio of the cores is reasonable, from 20% to 30%, and the arrangement of the column is suitable only for the outer column without an internal column.

A Study on the Correlation between Spatial Distance and Cognitive Intensity of High-rise Buildings - Focusing on High-rise Buildings of More than 30 Stories in Seoul - (초고층 랜드마크의 공간적 거리 및 인지강도와의 상관성 분석 - 서울시 30층 이상 고층건물을 대상으로 -)

  • Byeon, Jae-Sang;Im, Seung-Bin;Joo, Shin-Ha
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.35 no.4
    • /
    • pp.90-104
    • /
    • 2007
  • Landmarks like high-rise building are one of the important elements for the enhancement of city identity and provides the hierarchy of city streets, playing a central and symbolic role in cities. Research on physical attribute of landmarks, such as height, distance, location and shape, which are suitable for a city scale, can help a city create a distinct image and maintain comprehensible structure. To achieve this purpose, it is necessary to understand the spatial and cognitive characteristics of a landmark for the establishment and management of it. The results of this study can be summarized as follows: 1. The level of representativeness of a landmark increases in proportion to the degree of cognitive intensity on it. The relation between representativeness and cognitive intensity can be explained as the log-function as follows: Log(the number of people who respond "It has representativeness")=$-1.2579+1.5908{\times}$(cognitive intensity); 2. There are a few differences based on the attributes of respondents: while gender has no distinct influence, residential period and age show statistically meaningful influence on cognitive intensity of a vertical landmark Cognitive intensity of an individual landmarks especially, differs according to the class of main users. Because of frequent changes in occupation or employment, respondents consider the distance from a residential area more important than the distance from a working area in evaluating cognitive intensity of landmarks; 3. landmark can be classified into two kinds: a district landmark and an urban landmark A district landmark is closely connected with physical attributes of the landmark itself, such as distance, size and height. An urban landmark is mainly related to cognitive attributes such as the image and identity of a city as a whole. As a result, the landmark analysis data in this research provides spatial order and identity in a city. It is difficult to establish and reinforce the image of a city as a single element ike a landmark. However, withy steady follow-up research, this study could be seen as a systematic and logical model to improve urban landscape and image.

Interrelationship Study about Pilotis space utilization in high-rise apartment complex and indicator values related with Space Syntax circulation -Focusing on Hwaseong Dongtan Newtown Area Apartment- (고층아파트단지 필로티 공간의 이용도와 공간구문론 동선관련 지표값과의 상관성 연구 -화성동탄신도시아파트를 중심으로-)

  • Song, Byung-Ha;Lee, Ki-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.8
    • /
    • pp.5673-5682
    • /
    • 2015
  • Purpose of this study is to examine and investigate the utilization of low-rise floor Pilotis space which is frequently selected as a major planning element in recent high-rise apartment complex and to identify the interrelationship between the placement of Pilotis space in the complex and space utilization frequency by comparing circulation related indicators of Connectivity, Control Value, Global Integration and Local Integration through Space Syntax axial analysis. Conclusions of this study are, first, Pilotis space is not used as a space to improve regional community consciousness because it is mostly used as a 'simple movement space'. Second, regarding space utilization frequency differences in Pilotis space in each apartment building, projecting entry access+pilotis addition type complex shows more significant utilization frequency than pilotis access type complex, and the vandalism phenomenon is observed more often. Third, Pilotis space utilization is related with Connectivity, Control Value, Global Integration and Local Integration which are circulation related indicators in Space Syntax, and Pilotis spaces with high indicator values over 2 tend to show higher utilization frequency and those with low indicator values over 2 tend to show low utilization frequency.

Wind Tunnel Test Study on the Characteristics of Wind-Induced Responses of Tall Buildings with Openings (중공부(中空部)를 가진 고층건축물(高層建築物)의 풍응답(風應答) 특성(特性)에 관한 풍동실험(風洞實驗) 연구(硏究))

  • Kim, Dong Woo;Kil, Yong Sik;Ha, Young Cheol
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.4 s.77
    • /
    • pp.499-509
    • /
    • 2005
  • The excessive wind-induced motion of tall buildings most frequently result from vortex-shedding-induced across-wind oscillations. This form of excitation is most pronounced for relatively flexible, lightweight, and lightly damped high-rise buildings with constant cross-sections. This paper discusses the aerodynamic means ofmitigating the across-wind vortex shedding induced in such situations. Openings are added in both the drag and lift directions in the buildings to provide pressure equalization. Theytend to reduce the effectiveness of across-wind forces by reducing their magnitudes and disrupting their spatial correlation. The effects of buildings with several geometries of openings on aerodynamic excitations and displacement responses have been studied for high-rise buildings with square cross-sections and an aspect ratio of 8:1 in a wind tunnel. High-frequency force balance testshave been carried out at the Kumoh National University of Technology using rigid models with 24 kinds of opening shapes. The measured model's aerodynamic excitations and displacement were compared withthose of a square cylinder with no openings to estimate the effectiveness of openings for wind-induced oscillations. From these results, theopening shape, size, and location of buildings to reduce wind-induced vortex shedding and responses were pointed out.