• 제목/요약/키워드: High-rise Apartment Building

검색결과 183건 처리시간 0.023초

A Study on Securing Safety for High Rise Building Fires - Applying Active Fire Escape Systems -

  • Myung Sik, Lee;Sung Jae, Han
    • 국제초고층학회논문집
    • /
    • 제11권3호
    • /
    • pp.227-240
    • /
    • 2022
  • Under the Korean Enforcement Decree of the Building Act, all high story apartment houses more than 5 stories high are mandated to install a fire evacuation system to ensure safe evacuation from fire accidents and providing quick and easy bidirectional escape route when main entrance is blocked by flame or toxic smoke. However, the current fire evacuation system shows a lack of understanding from residents and thus is widely ignored for having insufficient safety functions, especially vis-à-vis fire emergencies. Studies have found that an alternative evacuation method, the escapable fire evacuation system, has been analyzed for safety evaluation compared with the conventional passive fire escape system and can bring efficient and safer solutions, providing high rise residents escape from fire accidents. Evaluation for safety evacuation has been performed by the Fire Dynamics Simulation and applying Pathfinder simulation. This resulted in providing appropriate escape routes within the safety escape time and allowed for people in high rise building fires to get to safety.

대구시 도시풍도에 대한 연구 (A Study on the City Wind Trail in Daegu)

  • 최영식
    • 한국산업융합학회 논문집
    • /
    • 제9권1호
    • /
    • pp.29-35
    • /
    • 2006
  • The population of Daegu, the third biggest city in Korea, is two point six million. Daegu is known as a basin or a city where it is not only too hot in summer but also too cold in winter. Recently with redevelopment apartment house boom, a 40-story or more apartment complexes are under construction near Shin-cheon and Dondaegu-ro, the south-north axis of Daegu. It is necessary to raise several points about blocking a road of the wind by high-rise apartment buildings and apartment complexes. As a kind of the green policy, Daegu enlarge the distance between apartment building by reconstructing low-rise apartment into high-rise and impose a duty of a green space on the ground by making a parking zone into an underground. Through this process, apartment complexes changed from a '一'shape to a '口'shape. It increases heat island phenomenon of a city by blocking a road of the wind that comes from Shin-cheon and Dondaegu-ro. To circulate the polluted air of Daegu basin, we need local wind. There are four effective measures. 1) Throw three greens into one in the center of the road at the north side in the same way of the south side of Dongdaegu-ro, 2) reflect the information of roads of the wind including heights, spaces and directions of buildings, 3) steer clear of a high-rise buildings and development apartment house constructions, and 4)select a city for benchmarking to be the environmental capital.

  • PDF

우리나라 고층건축화재의 문제점과 그 대책의 기본방향에 관한 연구 (A Study on Problems of High-rise Building Fires in Korea and the Basic Directions for Fire Safety of High-rise Building Design)

  • 이강훈
    • 한국화재소방학회논문지
    • /
    • 제4권2호
    • /
    • pp.15-26
    • /
    • 1990
  • Building become higher. larger and more complex than ever before, showing abrupt changes in building structures. forms and mechanical systems. Likewise hazads of fire and the scale of fire losses become more and more greater. Therefore. considerations for fire safety take up great portion of the building design process. In this study, problems of high-rise building fires and basic directions for fire safety of high-rise building design were studied through the statistical analysis of 138 fire cases. The results of this study are summarized as follows : ·Most of the fires in high-rise building occur on the low floors and the fire frequencies are very low on the upper floors. Fire casualties are liable to be more on the upper floors than on tile floor of fire origin. ·The important causes of evacuation failures were analyzed as being late in escape and lack of stairwell enclosures. ·The main cause of vertical fire spread is lack of stairwell enclosures. However, the fire spreads mainly through the enterior windows in apartment houses. The combustible materials in buildings act on as the major factors of horizontal fire spread and the improper fire doors play role of another the critical causes. ·The basic directions for fire safety of high-rise building design put much stress firstly on the compartmentation of the buildings effectively performing the provision of safe escape routes and the safe refuse places in buildings.

  • PDF

CFD에 의한 아파트 단지의 빌딩풍에 관한 사례연구 - 천안지역 2개 단지를 중심으로 - (Example Study on Building Wind of Apartment Complex by Computational Fluid Dynamics - About Two apartment Complex in Cheon-An Region -)

  • 노지웅
    • KIEAE Journal
    • /
    • 제8권4호
    • /
    • pp.37-42
    • /
    • 2008
  • In the case that high-rise building is constructed, the surrounding wind velocity increase more than 50~100%. From this cause, many wind environmental problems can be occurred. For example, ordinary wind environmental disaster may be occurred in a region, or walking disturbed. In developed countries including USA, EU, and Japan, many efforts have been made for building wind prevention by grasping previously the effects before building constructed. But, We are bearing risk of wind environmental disaster because we have not enough recognition about building wind, and have not architectural prevention counterplans. This study aims to examine wind environmental characteristics of domestic apartment complex, and effective architectural counterplans. As the basic stage for this, we investigated pre-estimate tools and risk assessment methods of building wind in apartment complex, applied to two apart complex in Cheon-An region by CFD. As the result, serious damages were not presented. But, it is obvious that various architectural counterplans will be presented by this example researches.

Canopy Model 적용을 통한 도심지 풍환경 예측 CFD 시뮬레이션 결과의 보정 (Modification of CFD results for Wind Environment in Urban area with Tree Canopy Model)

  • 정수현;홍인표;최종규;송두삼
    • 한국태양에너지학회 논문집
    • /
    • 제32권spc3호
    • /
    • pp.185-193
    • /
    • 2012
  • Recently rapid urbanization facilitates development of high-rise building complex including apartment and office building in urban area. Many problems related with high -rise building are reported. Especially, unpleasant strong winds in pedestrian area are frequently encountered around the high-rise building. CFD simulation methods are used to analyze the wind environment of pedestrian level in high-rise building block. However, the results show differences between CFD and measurement. This difference is attributed to improper use of CFD. Conventional CFD simulation for wind environment around high-rise building does not describe the effect of trees, shrubs and plants near ground which affect the wind environment of pedestrian level. Canopy model can be used to reproduce the aerodynamic effects of trees, shrubs and plants near ground. In this paper, CFD simulation methods coupled with the tree canopy model to predict wind environment of pedestrian level in high-rise residential building block were suggested and the validity was analyzed by comparison between measurement and CFD results.

초고층고층 건축물의 개구부에 대한 화재안전 설계방법 조사 (A Study on the Fire Safety Design Methods of Opening in High-rise Building)

  • 권영진;진승현;이병흔
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.8-9
    • /
    • 2018
  • In recent years, the fire risk in the aged housing facilities in high-rise building has been closing up due to the fire in the Grenfell Tower. In the case of these high-rise residential facilities, fire cases of residential facilities such as Uijeongbu Apartment Fire The fire hazard has been reexamined mainly. Especially, the fire of these residential facilities is very closely related to the window, so measures are needed. On the other hand, in Korea, there is almost no fire safety measures against these openings. Therefore, this study suggests improvement measures by comparison with advanced countries based on fire safety measures for domestic windows.

  • PDF

초고층 공동주택의 배기겸용 소형풍력발전 적용을 위한 기초연구(1) (A Basic Study on Application of Small Wind Power System Combined Ventilator in Super High-rise Apartment (1))

  • 박정하;김진우;장호진;박진철;황정하
    • 한국태양에너지학회 논문집
    • /
    • 제31권3호
    • /
    • pp.126-132
    • /
    • 2011
  • Recently, high-rise apartment is being briskly built but there are problems such as lack of ventilation, stack effect and much energy consumption. Therefore It is recommended to develop a Small Wind Power System Combined Ventilator as a solution to solve these problems. The purpose of this study is to provide basis for Small Wind Power System Combined Ventilator in super high-rise apartment. This study conducted CFD simulation (Star-CCM) according to the shape of structures, building height and distance of two structures to identify the effect of wind speed increase when the structure is installed. As a result, pyramidal type was best suited for increase of wind speed. The best place was the front of the roof to main wind direction, and the best building height was 200m rather than 300m. If two or more small wind turbines combined ventilator are installed closely, vertical position to main wind direction is recommended. Horizontal position must necessarily be avoided, but height difference between two blades more than 3m showed good performance.

초고층 공동주택의 이중외피 창호 유형별 실내기류 특성 비교 (Indoor Airflow of High-Rise Apartment with Different Types of Box-Windows)

  • 최태환;전미숙;이정현;김태연;이승복
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.993-998
    • /
    • 2006
  • High-rise apartments have a problem using natural ventilation because of the strong outdoor wind velocity. Conventional high-rise apartments have adopted mechanical ventilation systems to maintain the indoor air quality. However, it leads to the overuse of electricity and the sick house syndrome. Double-skin facade is the alternative for the high-rise building to use natural ventilation and this study is focused on the performance of the box-window, which is a kind of double-skin facades. Indoor wind velocity and HCHO concentrations are analyzed with three types of box-windows: the diagonal type, parallel type and perpendicular type. The airflow is simulated by computational fluid dynamics program. Box-windows reduce the maximum value of indoor wind velocity about 50% compared with the single window and the HCHO concentrations do not have the big difference. Box-windows could be the alternative to enhance the use of the natural ventilation and indoor air quality of the high-rise apartment.

  • PDF

A MULTI-STORY FIRE IN HIGH-RISE APARTMENT BUILDING DEVELOPED THROUGH BALCONIES - INVESTIGATION AND EXPERIMENTS -

  • Hasemi, Yuji;Hayashi, Yoshihiko;Hokugo, Akihiko;Yoshida, Masashi
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.361-368
    • /
    • 1997
  • Summary of experiments for the investigation of a fire which caused an upward fire spread for over 12 floors through balconies in a high-rise apartment complex is reported. The experiments include indoor tests to obtain fire properties of vertical PMMA fences and outdoor ones with a full scale model of the balcony. The test results suggest significance of the increase of total flame height by the merging of flames and a cooperative effect of the burning of the PMMA fence and combustibles on the balconies for the generation of a tall flame enough to cause ignition on the upper floors.

  • PDF

초고층 주상복합 건물의 하자 발생 유형 및 분석 연구 (The analysis of defects types and patterns in high-rise residential buildings)

  • 서장우;강경인
    • 한국건축시공학회지
    • /
    • 제9권2호
    • /
    • pp.93-101
    • /
    • 2009
  • Recently, public interest in housing defects, such as construction errors, occupiers' complaints, faults in production, and so on, is increasing. In addition, the construction requirements of high-rise residential buildings have increased, due to the higher prices of urban areas, especially in metropolitan areas. While previous research has focused on the defects occurring in apartment housing complexes, research has not been carried out on the defects occurring in high-rise residential buildings. In this paper, the defects patterns and characteristics of high-rise residential buildings are examined and analyzed and a defect management plan is then suggested. In order to do this, we collected the defects data of high-rise residential buildings recorded by 2,299 of 2,327 occupants. The defect occurrence rate (DOR) in the residential area is 98.8%. The frequency rate of defect occurrence over the total defect occurrence since building completion is 63.28% during the first year, 24.63% (second year), 6.88% (third year), 2.27% (fourth year), and 2.53% (fifth year). The result of correlation analysis between work types showed that there is a relationship between the built-in furniture and electronics (F&E) and painting works, and the F&E and masonry works, such as marble finishing. We expect that this research will assist in the efforts to decrease the number of defects in high-rise buildings.