• Title/Summary/Keyword: High-resolution ultrasonography

Search Result 20, Processing Time 0.011 seconds

Usefulness of High-Resolution Ultrasonography after Foreign Body Injection on Aesthetic Plastic Surgery (성형외과 영역에서 이물질 주사에 대한 고해상초음파 검사의 유용성)

  • Ko, Eung-Yeol;Sung, Ha-Min;Cho, Geon;Park, Young-Kyu;Tak, Kyoung-Seok;Suh, In-Suck;Yang, Ik
    • Archives of Plastic Surgery
    • /
    • v.37 no.4
    • /
    • pp.385-390
    • /
    • 2010
  • Purpose: The purpose of this study is to demonstrate the usefulness of the high resolutional ultrasonographic features in patients with foreign body. Methods: From September 2007 to August 2009, we retrospectively reviewed high resolutional ultrasonogram using 5~12 MHz linear transducer of 13 patients presenting with inflammation after foreign body injection. They were referred for complications after foreign body injection. Injected foreign bodies were 4 silicone, 4 paraffin, 2 artecoll, and 3 unknown. We treated them with foreign body removal (7), foreign body removal and corrective plastic surgery (4), and conservative treatment with antibiotics and steroid injection (2). Results: High resolutional ultrasonography well demonstrated the existence of foreign body and it's overall size, location within the tissue layer, and vascularity. Comparison between preoperative and postoperative ultrasonographic findings was useful not only to evaluate the prognosis but also to plan the treatment. These ultrasonographic findings aided in precise assessment of the contour and location of the foreign body and led to an accurate surgery. We were able to acquire various information in order to set a detailed plan for the operation which in turn, led to a precise, successful surgery. After the treatment, complication did not occur in 12 patients, except 1 patient. But this patient was also treated after reoperation. Postoperative high resolutional ultrasonography shows almost foreign body removed and inflammation disappeared. Conclusion: Considering the usefulness of highresolution ultrasonography in foreign body injection, highresolution ultrasonography would be necessary for both the patient and the doctor. Preoperative and postoperative high resolutional ultrasonography is highly accurate, safe, inexpensive and easy. It can be a useful modality in foreign body after plastic surgery.

Technique of ultrasonographic scanning of the shoulder joint (견관절의 초음파 검사 방법)

  • Jeon, Woong-Kyo
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.4 no.1
    • /
    • pp.42-49
    • /
    • 2011
  • Ultrasonography is a powerful and useful method for the examination of the various shoulder diseases. The use of high-resolution transducer and technical evolution allowed the improvement of the accuracy of detection of various shoulder pathology including the rotator cuff disease. However, its limitation is that there is marked disparity in the interpretation according to the operators' experience. This article describes the appropriate scan technique of ultrasonography around shoulder.

  • PDF

Correlation of Ultrasonography, MR and Arthroscopy of Rotator Cuff Disease (회전근 개 질환에서 초음파, 자기공명영상, 관절경 소견의 연관성)

  • Jeong, Woong-Kyo
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.1 no.2
    • /
    • pp.122-127
    • /
    • 2008
  • Ultrasonography is a powerful and useful method for the examination of the various shoulder diseases. The use of high-resolution transducer and technical evolution allowed the improvement of the accuracy of detection of the rotator cuff disease. However, its limitation is that there is marked disparity in the interpretation according to the operators' experience. This article describes the ultrasonographic findings of rotator cuff pathology compared to the MR (magnetic resonance) imaging and arthroscopic findings for helping the interpretation of ultrasonographic picture.

  • PDF

Role of contrast-enhanced harmonic endoscopic ultrasonography (EUS) and EUS elastography in pancreatic lesions

  • Yasunobu Yamashita;Masayuki Kitano
    • Clinical Endoscopy
    • /
    • v.57 no.2
    • /
    • pp.164-174
    • /
    • 2024
  • Pancreatic cancers have a poor prognosis, and their incident rates have risen. Endoscopic ultrasonography (EUS) is an efficient and reliable diagnostic modality for pancreatic lesions, providing high spatial resolution. However, while EUS helps to detect minor pancreatic lesions, nearly all solid pancreatic lesions are hypoechoic, which creates difficulty in making differential diagnoses of pancreatic lesions. When diagnosing pancreatic lesions, the performance of image-enhanced EUS techniques is essential, such as EUS elastography or contrast-enhanced harmonic EUS (CH-EUS). CH-EUS diagnosis is based on assessing the vascularity of lesions, whereas tissue elasticity is measured via EUS elastography. Elastography is either strain or shear-wave, depending on the different mechanical properties being evaluated. The usefulness of enhanced EUS techniques is demonstrated in this review for the differential diagnosis of pancreatic lesions, including solid and cystic lesions, and pancreatic cancer staging.

Fascicular Involvement of the Median Nerve Trunk in the Upper Arm: Manifestation as Anterior Interosseous Nerve Syndrome With Unique Imaging Features

  • Jae Eun Park;Darryl B. Sneag;Yun Sun Choi;Sung Hoon Oh;SeongJu Choi
    • Korean Journal of Radiology
    • /
    • v.25 no.5
    • /
    • pp.449-458
    • /
    • 2024
  • Selective fascicular involvement of the median nerve trunk above the elbow leading to anterior interosseous nerve (AIN) syndrome is a rare form of peripheral neuropathy. This condition has recently garnered increased attention within the medical community owing to advancements in imaging techniques and a growing number of reported cases. In this article, we explore the topographical anatomy of the median nerve trunk and the clinical features associated with AIN palsy. Our focus extends to unique manifestations captured through MRI and ultrasonography (US) studies, highlighting noteworthy findings, such as nerve fascicle swelling, incomplete constrictions, hourglass-like constrictions, and torsions, particularly in the posterior/posteromedial region of the median nerve. Surgical observations have further enhanced the understanding of this complex neuropathic condition. High-resolution MRI not only reveals denervation changes in the AIN and median nerve territories but also illuminates these alterations without the presence of compressing structures. The pivotal roles of high-resolution MRI and US in diagnosing this condition and guiding the formulation of an optimal treatment strategy are emphasized.

The Usefulness of Ultrasound Diagnosis of Acute Tendon Injury in Hand (급성 건 손상 환자에서 초음파의 유용성)

  • Choi, Chang Yong;Lee, Han Jeong;Choi, Hwan Jun;Kim, Mi Sun
    • Archives of Plastic Surgery
    • /
    • v.35 no.6
    • /
    • pp.729-734
    • /
    • 2008
  • Purpose: The evaluation and management of a completely transected tendon of the hand is relatively clear. In most cases, the integrity is assessed by physical examination(eg, broken normal cascade, motion loss) but occasionally, It happens in troubles. because of pain, limited patient cooperation(eg, child, unconscious patient), and other associated injuries(eg, fractures, foreign bodies). Methods: From september 2006 to August 2007, 28 patients were evaluated with real time ultrasonography preoperatively and postoperatively. Twenty eight patients with injured tendon were evaluated using an HDI 5000 Sono CT(Philips Medical Systems, Bothell, WA) machine with a high resolution, 7.5MHz hockey stick linear probe. Dynamic evaluation was performed in real time. Results: Surgery was performed after the ultrasonographic evaluation. Sonographic diagnosis and intraoperative findings were correlated. Ultrasonographic findings show tendon discontinuity, gaps, and fluid collection. Conclusion: We conclude that ultrasonography is helpful in evaluating and managing acute tendon injury. Especially, in cases of completely lacerated tendon, ultrasonography can identify the location of the proximal tendon stump and partial lacerated tendon, ultrasonographic diagnostic tool can decrease misdiagnosis.

The Value of High Resolution Ultrasonography in Diagnosis of Thyroid Nodule (갑상선 결절의 진단에 있어서 고해상능 초음파검사의 가치)

  • Shim Hyung-Jin;Choung Hue-Moon;Yoon Jung-Han;JeGal Young-Jong;Park Jin-Gyoon
    • Korean Journal of Head & Neck Oncology
    • /
    • v.6 no.2
    • /
    • pp.114-118
    • /
    • 1990
  • A clinical study of 37 cases with thyroid nodules, which were treated by surgical excision and confirmed pathologically at the Department of Surgery, Chonnam National University Medical School, from Dec. 1988 to Feb. 1990, was conducted and following results were obtained in ultrasonographic evaluation of thyroid nodules. 1) The thyroid adenoma were showed well-defined margin, homogenous internal echo and surrounding Halo, but thyroid cancer were showed ill-defined margin, inhomogenous internal echo and no surrounding Halo. 2) The sensitivity of high resoution ultrasonography compared with pathologic diagnosis to thyroid cancer was 87.5%, specificity 94.1%, accuracy 88%, false positive 5.88%, and negative 12.5%.

  • PDF

Usefulness of Ultrasonography in Diagnosis of Small Foreign Bodies (체내 소형 이물질 진단에서 초음파 검사의 유용성)

  • Kim, Chol Jin;Chung, Yang Guk;Park, Tae Yong
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.5 no.2
    • /
    • pp.75-80
    • /
    • 2012
  • Purpose: The purpose of this study is to evaluate the usefulness of ultrasonographic examination for diagnosis and removal of small sized foreign bodies, which invaded extremity but difficulty to find on physical examination and/or plane radiographs. Materials and Methods: Since March, 2009 to February, 2012, we performed preoperatively ultrasonography and operation in 9 cases of foreign bodies of hand or foot. Mean symptom duration periods was 32 months. The location were fingers in 5, palms in 2, hand dorsum in 1, heel in 1 case. In 2 cases, foreign bodies were seen on plane radiographs. In the remaining 7 cases, foreign bodies could be diagnosed by ultrasonography only. Using high resolution stick probe, we performed evaluation on size, location, character of foreign bodies and compared preoperative ultrasonographic findings to intraoperative ones. Results: The site of foreign bodies in preoperative ultrasonography corresponded well with intraoperative findings. Foreign bodies were glass particles in 5, plant thorns in 4, pencil lead in 1. Mean size was 3.9 mm (2~7 mm). Conclusion: Ultrasonography is usefull evaluation tool for diagnosis and treatment in whom residual foreign bodies were suspected.

  • PDF

Role of fetal ultrasound in prenatally diagnosed de novo balanced translocations

  • Seong, Eui Sun;Youn, Hye Jin;Park, Min Kyung;Boo, Hye Yeon;Lee, Bom Yi;Ryu, Hyun Mee;Han, You Jung
    • Journal of Genetic Medicine
    • /
    • v.15 no.1
    • /
    • pp.8-12
    • /
    • 2018
  • Purpose: This study aimed to investigate fetal ultrasonographic findings in cases of prenatally diagnosed de novo balanced translocations and the role of fetal ultrasound in prenatal genetic counseling. Materials and Methods: We collected cases with de novo balanced translocations that were confirmed in chorionic villus sampling, amniocentesis, and cordocentesis between 1995 and 2016. A detailed, high-resolution ultrasonography was performed for prediction of prognosis. Chromosomes from the parents of affected fetuses were also analyzed to determine whether the balanced translocations were de novo or inherited. Results: Among 32,070 cases with prenatal cytogenetic analysis, 27 cases (1/1,188 incidence) with de novo balanced translocations were identified. Fourteen cases (51.9%) showed abnormal findings, and the frequency of major structural anomalies was 11.1%. Excluding the major structural anomalies, all mothers who continued pregnancies delivered healthy babies. Conclusion: Results of a detailed, high-resolution ultrasound examination are very important in genetic counseling for prenatally diagnosed de novo balanced translocations.

Imaging of the Brachial Plexus (상완신경총의 영상)

  • Suh, Kyung-Jin;Lee, Jeong-Hyun;Lee, Gyung Kyu
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.2
    • /
    • pp.119-126
    • /
    • 2007
  • MR (magnetic resonance) imaging of the brachial plexus is challenging because of the complex and tangled anatomy of the brachial plexus and the multifariouness of pathologies that can put on it. Improvements in imaging techniques, including the availability of high resolution MR image systems and high channels multidetector computed tomography (CT), have led to more accurate diagnoses and improved serve for treatment planning. For the purpose of imaging and treatment of the brachioplexopathy, it is considerate to divide traumatic and nontraumatic diseases affecting the brachial plexus. MRI is the current gold standard imaging modality for nontraumatic brachial plexopathy. CT myelography is the preferred for the diagnosis of nerve root avulsions affecting the brachial plexus. Other modalities, such as CT, ultrasonography and positron emission tomography, have a limited role in the evaluation of brachial plexus pathology. High-quality, high-resolution MRI remains the main tool for imaging the brachial plexopathy.

  • PDF