• Title/Summary/Keyword: High-resolution image transmission

Search Result 98, Processing Time 0.04 seconds

Multi-Channel High Speed Data Link Design for Small SAR Satellite Image Data Transmission

  • Kwag, Young K.
    • Proceedings of the IEEK Conference
    • /
    • 2002.07c
    • /
    • pp.1436-1439
    • /
    • 2002
  • In this paper, based on the data link model characterized by the spaceborne small SAR system, the high rate multi-channel data link module is designed including link storage, link processor, transmitter, and wide-angle antenna. The design results are presented with the performance analysis on the data link budget as well as the multi-mode data rate in association with the SAR imaging mode of operation from high resolution to the wide swath.

  • PDF

Resource Reservation Based Image Data Transmission Scheme for Surveillance Sensor Networks (감시정찰 센서 네트워크를 위한 자원예약 기반 이미지 데이터 전송 기법)

  • Song, Woon-Seop;Jung, Woo-Sung;Ko, Young-Bae
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39C no.11
    • /
    • pp.1104-1113
    • /
    • 2014
  • Future combat systems can be represented as the NCW (Network Centric Warefare), which is based on the concept of Sensor-to-Shooter. A wireless video sensor networking technology, one of the core components of NCW, has been actively applied for the purpose of tactical surveillance. In such a surveillance sensor network, multi-composite sensors, especially consisting of image sensors are utilized to improve reliability for intrusion detection and enemy tracing. However, these sensors may cause a problem of requiring very high network capacity and energy consumption. In order to alleviate this problem, this paper proposes an image data transmission scheme based on resource reservation. The proposed scheme can make it possible to have more reliable image data transmission by choosing proper multiple interfaces, while trying to control resolution and compression quality of image data based on network resource availability. By the performance analysis using NS-3 simulation, we have confirmed the transmission reliability as well as energy efficiency of the proposed scheme.

High-resolution Transmission Electron Microscopy of Ordered Structure for Lead Magnesium Niobate Solid Solutions ($Pb(Mg_{1/3}Nb_{2/3})O_3$ 고용체에서 고분해능 투과전자현미경을 이용한 구조 규칙화에 대한 연구)

  • Park, Kyeong-Soon
    • Applied Microscopy
    • /
    • v.27 no.1
    • /
    • pp.101-109
    • /
    • 1997
  • The nonstoichiometric ordering of Mg and Nb cations in undoped and La-doped lead magnesium niobate solid solutions has been investigated by means of high-resolution transmission electron microscopy and computer image simulation. High-resolution lattice images were obtained under various microscope imaging conditions and objective apertures. Computer image simulations were performed for a wide range of sample thickness, defocusing value, and long-range order parameter. The simulated images revealed that the lattice images of the ordered regions were predominantly dependent on the long-range order parameter. From the comparisons of the experimental and simulated images for the ordered regions, the long-range order parameter approximately ranged 0.2 to 0 7. It was also found that the ordered structure has a $(NH_4)_3-FeF_6$ structure, which consists of alternating Mg- and Nb-preferred sublattices along the (111) directions.

  • PDF

HIGH-SPEED SOFTWARE FRAME SYNCHRONIZER USING SSE2 TECHNOLOGY

  • Koo, In-Hoi;Ahn, Sang-Il;Kim, Tae-Hoon;Sakong, Young-Ho
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.522-525
    • /
    • 2007
  • Frame Synchronization is applied to not only digital data transmission for data synchronization between transmitter and receiver but also data communication with satellite. When satellite image data with high resolution and mass storage is transmitted, hardware frame synchronizer for real-time processing or software frame synchronizer for post-processing is used. In case of hardware, processing with high speed is available but data loss may happen for Search of Frame Synchronization. In case of software, data loss does not happen but speed is relatively slow. In this paper, Pending Buffer concept was proposed to cope with data loss according to processing status of Frame Synchronization. Algorithm to process Frame synchronization with high speed using bit threshold search algorithm with pattern search technique and SIMD is also proposed.

  • PDF

The Design of High-Speed, High-Resolution D/A Converter for Digital Image Signal Processing with Deglitching Current Cell (글리치 방지 전류원을 이용한 고속 고정밀 디지탈 영상 신호 처리용 D/A 변환기 설계)

  • Lee, Seong-Dae;Jeong, Gang-Min
    • The Transactions of the Korea Information Processing Society
    • /
    • v.1 no.4
    • /
    • pp.469-478
    • /
    • 1994
  • In this paper, a high speed, high resolution information processing digital- analog converter was designed for high definition color graphic, digital image signal processing, HDTV. For high speed operation, matrix type current cell array, latch which is not use pipelined, and two dimensional structure decoder using transmission gate were designed. It is adopted to fast-conversion, low-power implementation and exhibited high performance at linearity and accuracy. To reduce silicon area and to maintain resolution, current cell array composed of weighted and non-weighted current cells. In this paper, deglitching current cell design for high accuracy, new switching algorithm assert to reduce switching error. It's This circuit dissipates 130W with a 5-V power supply, and operate above 100MHz with 10 bit resolution.

  • PDF

The optical characteristics study of sandwich structure based liquid crystal for the radiation detector application (방사선 검출기 적용을 위한 액정 기반 다층 구조의 광 특성 평가)

  • Shin, Jung-Wook;Kang, Sang-Sik;Park, Ji-Koon;Cho, Sung-Ho;Cha, Byung-Yul;Kim, Jin-Young;Lee, Gun-Hwan;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.390-392
    • /
    • 2005
  • The digital radiation detectors are used clinically by diagnostic apparatus. However the digital radiation detector are some problem like high operating voltage, light blurring, low conversion efficiency, low fill factor, etc. Thus we propose a new radiation detector that the photoconductor layer and liquid crystal layer are coupled in sandwich structure. X-ray absorption in the photoconductor layer controls the state of the liquid crystal via creation of charge carrier and the light modulation of liquid crystal make image formation. The advantage of the new radiation detector is that high resolution image is acquired and the signal amplification is possible by external visible light source. In this study, we study the optical properties and electrical properties of the new radiation detector to irradiate X-ray. The Mercury Iodide($HgI_2$) was used by photoconductor material, and the aluminum is used by reflective layer. The thickness of Mercury Iodide is about $200{\mu}m$, the operating voltage of the liquid crystal is 1.5~5V. The electrical properties of Mercury Iodide was measured, and the transmission efficiency of liquid crystal was measured by modulation potential.

  • PDF

The Fabricating and Utilizing of the Transmission Scan Tool for I-131 Whole Body Scan (I-131 전신 스캔을 위한 Transmission Scan Tool 제작과 활용)

  • Shin, Chae-Ho;Pyo, Sung-Jai;Kim, Bong-Su;Cho, Yong-Gyi;Jo, Jin-Woo;Kim, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.40-46
    • /
    • 2009
  • Purpose: A whole body scan using a radioactive iodine (I-131) for the patients with differentiated thyroid cancer is generally an useful method to detect the remnant thyroid tissue, recurred lesion or metastasis lesion after a surgery. The high dose treatment using the radioactive iodine recently tends to increase, and a hospitalization wait for the treatment has been delayed for several months. In this hospital, the treatable patients per week were increased in number through expanding a water-purifier tank and the examination time also increased as the I-131 whole body scan patients increased. Improvement for this problem, this research reduce the existing examination time and classifying the lesion's exact position intended to by fabricating and utilizing the transmission scan tool and an excellent resolution for whole body imaging. Materials and Methods: After conducting the whole body scan for patients who visited the department from February to July 2008 and received the I-131 whole body scan using the ORBITER Gamma Camera. A rail was installed in the examination table for the transmission scan for show a contour of surface area and then the transmission image was obtained and fused to the whole body scan through fabricating the tool to put a flood phantom of diluted 2 mCi $^{99m}Tc$-pertechnetate. Results: Fused image of I-131 whole body scan and the transmission scan had the excellent resolution to discriminate an oral cavity or salivary gland region, neck region's lesion, and metastasis region's position through a simple marking, and could reduce the examination time of 8~28 minutes because without the additional local image. Conclusions: In I-131 whole body scan, the transmission scan can accurately show a contour of surface area through the attenuation of radioactivity, and is useful to indicate the remnant thyroid tissue or metastasis lesion's position by improving the resolution through the fusion image with alreadyexecuted I-131 whole body scan. Also, because the additional local image is not necessary, it can reduce the time required for the examination. It will extensively apply to other clinical examinations to be helpful for identifying an anatomical position because it shows the contour of surface area.

  • PDF

Applying a Two-channel Video Streaming Technology Front and Rear Vehicle Wireless Video Monitoring System (2채널 영상 스트리밍 기술을 적용한 차량용 전. 후방 무선 영상 모니터링 시스템)

  • Na, HeeSu;Won, YoungJin;Yoon, JungGeun;Lee, SangMin;Ahn, MyeongIl;Kim, DongHyun;Moon, JongHoon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.12
    • /
    • pp.210-216
    • /
    • 2014
  • In this paper, it was proposed to develop front and rear image monitoring system for vehicle that help a driver to cope with urgent situation about a dangerous element. When parking a vehicle, the risk factors to be formed by the dead zone can be resolved by using anterior and posterior cameras of the vehicle. In embedded system environment, a SoC(System on Chip) and two high-resolution CMOS (Complementary metal-oxide-semiconductor) image sensors were used to transfer two high-resolution image data through he TCP/ IP-based network. To transfer image data through he TCP/ IP-based network, the images received by two cameras were compressed by using H.264 and they were transmitted with wireless method(Wi-Fi) by using real-time transport protocol (Real-time Transport Protocol). Transmission loss, transmission delay and transmission limit were solved in wireless (Wi-Fi) environment and the bit-rate of two image data compressed by H.264 was adjusted. And the system for the optimal transmission in wireless (Wi-Fi) environment was materialized and experimented.

High resolution structural analysis of biomolecules using cryo-electron microscopy (초저온 전자현미경법을 통한 고분해능 생물분자 구조분석)

  • Hyun, Jaekyung
    • Vacuum Magazine
    • /
    • v.4 no.4
    • /
    • pp.18-22
    • /
    • 2017
  • Transmission electron microscopy (TEM) is a versatile and powerful technique that enables direct visualization of biological samples of sizes ranging from whole cell to near-atomic resolution details of a protein molecule. Thanks to numerous technical breakthroughs and monumental discoveries, 3D electron microscopy (3DEM) has become an indispensable tool in the field of structural biology. In particular, development of cryo-electron microscopy(cryo-EM) and computational image processing played pivotal role for the determination of 3D structures of complex biological systems at sub-molecular resolution. Here, basis of TEM and 3DEM will be introduced, especially focusing on technical advancements and practical applications. Also, future prospective of constantly evolving 3DEM field will be discussed, with an anticipation of great biological discoveries that were once considered impossible.

Theory of High Resolution TEM Image Formation: Coherence (2) (TEM 관련 이론해설(7): 투과전자현미경의 고분해능 영상이론: 결맞음 (2))

  • Lee, Hwack-Joo
    • Applied Microscopy
    • /
    • v.36 no.1
    • /
    • pp.1-6
    • /
    • 2006
  • In this review, the important ideas of coherence theory are introduced. The transfer function and damping envelopes of the microscope due to temporal and spatial coherence are described. The passbands and the condition of Scherzer focus are discussed in associated with the resolution of transmission electron microscope. The characterization of coherence is also described.