• 제목/요약/키워드: High-line

검색결과 8,123건 처리시간 0.038초

20∼30대 인터넷 쇼핑몰 이용자의 강박적 구매성향과 인터넷 중독성향에 관한 연구 (A Study in Compulsive Buying Behaviors and Internet Addiction among E-Commerce Users between the Ages of 20~30)

  • 강이주;이영애
    • 대한가정학회지
    • /
    • 제48권1호
    • /
    • pp.67-81
    • /
    • 2010
  • Consumer researchers found that compulsive buying was a part of a category of compulsive consumption that was interrelated to addictive and repetitive behaviors. The present study empirically examined the co-morbidity of compulsive buying and Internet addiction among e-commerce users in terms of consumption disorders. Although the prevalence of Internet use and on-line sales remarkably increase in recent years, almost no study examines on-line compulsive buying behavior. This study explored the link between compulsive buying and Internet addiction among e-commerce users, and investigated the characteristics of on-line shoppers with respect to two forms of compulsive consumption, which were divided into compulsive buying and Internet addiction. Additionally, factors that related to compulsive buying behaviors among e-commerce users were also examined. The present research was conducted using a convenience sample of 394 young adults between the ages of 20-30, and the Faber and O'Guinn's DSCB scale and the Widyanto's Internet addiction scale (IA) were used. Confirmatory factor analyses were utilized to evaluate the structure of the DSCB and IA, and a Probit model was used to examine determinants for the compulsive buying behaviors of e-commerce users. E-commerce users were classified into four groups; high compulsion and high addiction, low compulsion and low addiction, high compulsion and low addiction, and low compulsion and high addiction. Consumers with high compulsion and high addiction spent higher amounts of money on their on-line purchases and were frequently connected with the Internet compared to the three other consumer groups. Consumers with compulsive buying behaviors were also found to have significantly greater Internet addiction tendencies than typical buyers. Compulsive buyers were more likely to engage in Internet addiction and the number of purchasing via on-line shopping mall, and had higher materialism. Policy implications and suggestions for consumer education programs were discussed.

고집적 메모리에서 BLSFs(Bit-Line Sensitive Faults)를 위한 새로운 테스트 알고리즘 (A New Test Algorithm for Bit-Line Sensitive Faults in High-Density Memories)

  • 강동철;조상복
    • 전기전자학회논문지
    • /
    • 제5권1호
    • /
    • pp.43-51
    • /
    • 2001
  • 메모리의 집적도가 올라갈수록 원치 않는 셀간의 간섭과 동시에 bit-line간의 상호 노이즈도 증가하게 된다. 그리고 높은 고장 검출율을 요구하는 고집적 메모리의 테스트는 많은 테스트 백터를 요구하게 되거나 비교적 큰 추가 테스트 회로를 요구하게 된다. 지금까지 기존의 테스트 알고리즘은 이웃 bit-line의 간섭이 아니라 이웃 셀에 중점을 두었다. 본 논문에서는 NPSFs(Neighborhood Pattern Sensitive Faults)를 기본으로 한 NBLSFs(Neighborhood Bit-Line Sensitive Faults)를 위한 새로운 테스터 알고리즘을 제안한다. 그리고 제안된 알고리즘은 부가 회로를 요구하지 않는다. 메모리 테스트를 위해 기존의 5개의 셀 레이아웃이나 9개의 셀 레이아웃을 사용하지 않고 NBLSF 검출에 최소한 크기인 3개의 셀 레이아웃을 이용하였다. 더구나 이웃 bit-line에 의한 최대의 상호잡음을 고려하기 위해 테스트 동작에 refresh 동작을 추가하였다(예 $write{\rightarrow}\;refresh{\rightarrow}\;read$). 또한 고착고장, 천이고장, 결합고장, 기존의 pattern sensitive 고장, 그리고 이웃 bit-line sensitive 고장 등도 검출될 수 있음을 보여준다.

  • PDF

Assessment of 23 kV Capacitive Coupler for On-line Partial Discharge Measurements

  • Jeong, J.Y.;Kang, D.S.;Sun, J.H.;Heo, J.C.;Park, C.H.
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권1호
    • /
    • pp.123-130
    • /
    • 2009
  • The partial discharge (PD) measurement is a very effective method to assess the winding insulation condition of high-voltage machines, since most of the insulation failure processes are directly or indirectly caused by PD. On-line PD measurements, which can detect insulation defects of winding in the early stages on rotating machines in operation, have been accepted as the most important technique. The epoxy mica capacitive coupler is currently and extensively used for on-line detection of PD pulses of high-voltage rotating machines. To evaluate the feasibility of developing a capacitive coupler that is easier to manufacture at a lower cost compared to epoxy mica couplers, a 100pF capacitive coupler made of ceramic material is designed, fabricated and tested for on-line PD measurements of 23 kV electrical machines. A series of electrical tests and accelerated aging tests are performed on the ceramic coupler to evaluate the performance requirements, long-term reliability and thermal stability for in field application. The test results show that the newly developed ceramic coupler provides equal and improved performance at a lower cost compared to epoxy mica couplers, and estimated voltage life is anticipated to surpass 100 years.

전력선 통신을 이용한 plant 감시 제어 시스템 (Spread Spectrum Method based Power Line Communication for Plant Monitoring and Control System)

  • 서민상;성석경;안병규
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1997년도 전력전자학술대회 논문집
    • /
    • pp.211-215
    • /
    • 1997
  • Localized communication networks for office automation, security monitoring, environmental management of buildings, computer communications, and other applications enjoy every increasing demand. This paper proposes a direct sequence spread spectrum communication system for use in power line data transmission. Advantages of power distribution circuits include reasonably universal coverage and easy access vis a standard wall plug. Disadvantages include limited communication bandwidth, relatively high noise levels, and varying levels of impedance, noise, and attenuation. Spread spectrum signalling provides immunity to narrow-band signal impairments and multiplexing capability. Our prototype power line communication module supports completely physical and data link layers based on the international standard ISO 10368 for reliable high-speed power line communication system. Moreover it provides useful functions to compose a plant monitoring and control system. All the circuits of the communication module are included in one compact circuit. Thus a functional communication system for the power line plant monitoring and control is implemented.

  • PDF

철도에서 DSL 모뎀을 사용한 데이터 전송에 관한 고찰 (An investigation of data transmission scheme using DSL modem)

  • 조봉관;최규형;장석각
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.1446-1448
    • /
    • 2004
  • Communication line used in the rail-road have different use from subscriber line in the public telecommunication. But, when an existing communication equipment is replaced, by applying new high-speed transfer technology, we can anticipate the increase of transmission rate and decrease of waiting time according to high-speed of communication line. cost reduction of infrastructure construction and maintenance/repair according to centralization of communication line and transmission equipment. In this study, the transmission scheme of several xDSL(Digital Subscriber Line) modems were compared and analyzed. The way of applying xDSL modem to the metal cable which is used in the JR(Japan Railroad) is analyzed. In addition, the result tested in railroad communication line was reviewed.

  • PDF

기존선-고속선 연결선 구간에서 최대부하용량 평가 (Estimation of Maximum Load Capacity at Interconnection Line of High-Speed and Conventional Line)

  • 이장무;이한민;오세찬;김길동;장길수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1069-1070
    • /
    • 2008
  • At the coupling area linking high speed line and conventional line, according to distance between trains due to speed limit of conventional line, the power load of substation supplying to this conventional line increase. At the coupling area between Kimcheon SS and Kyoungsan SS, train operation have problems caused by instantaneous voltage drop. So, this paper propose evaluation method of maximum load capacity at current normal feeding condition.

  • PDF

GIC를 이용한 전력선통신용 송수신 분리형 라인커플러의 개발 (Development of the separated transmission and reception Line Coupler using GIC for Power Line Communication)

  • 최원호;박준용;박종연
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 I
    • /
    • pp.238-241
    • /
    • 2003
  • The purpose of this study is to improve the frequency response of the Line coupler for Power Line Communication. We separate transmission and reception line coupler and design the reception line coupler using GIC. It was found from the result that separation transmission and reception line coupler using GIC have the advantage of a design and high Q.

  • PDF

고속 라인 스캔 방식을 이용한 CFRP 가공 홀 표면 및 내부 결함 검사 (Measurements of Defects after Machining CFRP Holes Using High Speed Line Scan)

  • 김택겸;경대수;손운철;박선영
    • 한국정밀공학회지
    • /
    • 제33권6호
    • /
    • pp.459-467
    • /
    • 2016
  • Using a line scan camera and a Galvano mirror, we constructed a high-speed line-scanning microscope that can generate 2D images ($8000{\times}8000pixels$) without any moving parts. The line scanner consists of a Galvano mirror and a cylindrical lens, which creates a line focus that sweeps over the sample. The measured resolutions in the x (perpendicular to line focus) and y (parallel to line focus) directions are both $2{\mu}m$, with a 2X scan lens and a 3X relay lens. This optical system is useful for measuring defects, such as spalling, chipping, delamination, etc., on the surface of carbon fiber reinforced plastic (CFRP) holes after machining in conjunction with adjustments in the angle of LED lighting. Defects on the inner wall of holes are measured by line confocal laser scanning. This confocal method will be useful for analyzing defects after CFRP machining and for fast 3D image reconstruction.

분산전원 계통 연계 전용선로에 설치된 보호 계전기의 정정에 관한 연구 (A Study on Correction of the Protective Relay Equipped in the Dedicated Line Used for Connecting Distributed Generators to Power Network)

  • 정종찬;장성일;최돈만;김광호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.141-144
    • /
    • 2002
  • This paper describes the correction of the protective relay equipped in the dedicated line used for connecting distributed generators (DG) to power grid. The fault current measured in a relaying point might be changed according to the fault conditions. Generally, the fault current of the line to line fault or the line to ground fault at the dedicated line is much higher than the protective set value due to the large fault level. However. when the high impedance fault is occurred in the dedicated line, we may not detect it because its fault level can be lower than the generating capacity of DG. And, the protective relay with conventional set value may generate a trip signal for insertion of DG due to the large transient characteristics of generators. Through the various simulations such as the fault in the dedicated line and the insertion of DG, we show that it would be necessary to modify the protective relay set value for detecting the high impedance fault occurred in the dedicated line and for preventing the mis-operation of protective relay caused by the insertion of DG.

  • PDF

기존선 해빙시스템 구성을 위한 해빙전류 예측기법 (Estimation Technique of deicing current for configuration of deicing system in conventional line)

  • 정호성;권삼영;박영;안병립;이주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.288-290
    • /
    • 2005
  • Deicing system operated in high speed line is to melt frost or ice freezed in catenary line when the temperature is lower than 0 in winter. The principle of deicing system is to m디t frost or ice by Joule heat of catenary impedance. The performance of deicing is dependant of deicing current determined by the length of deicing section, deicing impedance and current division ratio of catenary line and messenger line. So, We present technique for estimating deicing current in convention line. Deicing impedance is estimated using Carson - Pollaczek, current division ratio of catenary line and messenger line is estimated using voltage drop, and deicing current is estimated using power system data of operation secion for deicing system in this technique. To verify the validity of technique, we compare the estimated current using technique of this paper with deicng current of high speed line.

  • PDF