• 제목/요약/키워드: High-frequency stimulator

검색결과 18건 처리시간 0.022초

저주파/고주파와 냉자극을 이용한 의료용 조합 자극기의 설계 및 구현 (Design and Implementation of Medical Compound Stimulator Using Low/High Frequency and Cooling Stimulation)

  • 윤완오;강석엽;정진하;최상방
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권1호
    • /
    • pp.82-87
    • /
    • 2008
  • In this paper, the study was carried out to design and implement the medical compound stimulator based on the preexisting individual medical stimulators with Low frequency, High frequency and cooling stimulation. The proposed equipment is designed to compound all the functions including a cooling stimulation with a range of $0{\sim}20^{\circ}C$ and the verified low and high frequencies of 250Hz, 500Hz, 1KHz and 1MHz respectively from the previous clinical experiment with a consideration of its credibility and efficiency. Also, it was constructed by using a new technique, thermoelectricity semiconductor with a consideration of miniaturization and stability. In accordance with patients' treatment purpose, the hand piece of low frequency/cooling stimulation and High frequency/cooling stimulation were separately designed for convenience. The frequency, accuracy and other factors of implemented medical compound stimulator was satisfied according to its measurement. It was also tested by Korean Testing Laboratory (KTL) for its stability and efficacy and it confirmed that the medical compound stimulator is suitable for use as it fits in with the medical equipment standards.

개인용 저주파 자극기의 특성분석 및 Prototype개발 (A Prototype Development of Personal Low-frequency Stimulator with Characteristic Analysis)

  • 이기송;이동하;유재택
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.349-352
    • /
    • 2003
  • A personal low-frequency stimulator is a portable device to relax muscle pains of a person. The stimulator generates combined low-frequency pulses to be applied to pads attached to painful muscles. This paper reports a development of such device with its characteristic analyses. The major components of our stimulator are MCU, high-voltage generating circuit part, high-voltage switching circuit part, input switch part and display unit. High-voltage generating circuit is designed by using a boost converter circuit and allows user control of the output voltage. High-voltage switching circuit, controlled by MCU, generates output voltage to be applied to pads. Input switch part is composed of power supply, intensity selection, mode selection and memory. Display unit adopts a text LCD module to display modes, Intensity, output frequency and user set-up time. Our designed safety circuit, to protect human body from possible electric shock, slowly increases the output voltage to the selected output intensity. It continuously checks the output pulse shape and disable the output when dangerous pulses are detected. This paper also shows some experimental results.

  • PDF

저주파 플라이백 스위칭회로를 이용한 고성능 자기자극기 (A Magnetic Stimulator Adopting a Low-Frequency Fly-Back Switching Circuit)

  • 이정한;김형식;허문창;김정회
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권6호
    • /
    • pp.343-350
    • /
    • 2006
  • Medical magnetic stimulator generates strong magnetic field pulses. Clinical applications of the magnetic pulse are the stimulation of nervous system and the contraction of muscle. The unique source of the strong magnetic pulse is a capacitor-inductor resonator and this inductor generates a strong sinusoidal magnetic pulse by discharging the capacitor with high initial voltage. Continuous muscle contraction needs sequential generation of the magnetic pulses. However, to keep the magnitude of sequential pulses identical, an expensive high-voltage power supply have to support voltage drop of the capacitor between the pulses. A protection circuit between the supply and the resonator is necessary to protect the supply from reverse current caused by capacitor voltage reversal. In this paper, a new circuit structure of the magnetic stimulator adopting a low-frequency fly-back switching is proposed. The new circuit supports sequential pulse generation and allows the reverse current without damage. Performance of the new circuit is examined and a low-cost magnetic stimulator for urinary incontinence therapy is being developed using the presented method.

심부투열용 2MHz 고주파 재활치료기의 개발에 관한 연구 (A Study on Development of 2MHz High-frequency Rehabilitation Treatment Device for Deep Part)

  • 안종복;김상범;원철희;김성훈;박철원
    • 전기학회논문지P
    • /
    • 제66권3호
    • /
    • pp.117-122
    • /
    • 2017
  • Due to the aging and obesity population in Korea, degenerative musculoskeletal diseases and people suffering from degenerative arthritis are increasing day by day. So, it is necessary to develop rehabilitation treatment device. Conventional high-frequency treatment devices have disadvantages in that therapeutic range is narrow, cost is high, image is adversely affected, treatment time is long, and failure rate is high. This paper proposes a customized therapy device that is stable and effective in reducing treatment time and output to target body part using 2MHz switching frequency, feedback control technique, and joint insulation flexible multipolar electrode. The device can be a new concept high-frequency stimulator to accommodate the advantages of CET and RET.

혈압조절을 위한 모선 제어되는 체내 이식형 전기 자극기의 개발 및 체외 성능 평가 (Development and Estimation of a Wireless Controlled Implantable Electric-stimulator for the Blood Pressure Regulation)

  • 김유석;박성민;심은보;최성욱
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권5호
    • /
    • pp.395-400
    • /
    • 2010
  • Hypertension is the chronic disease that the 16% of total population are suffering, and it needs to be studied to find alternative treatment because of the tolerance and side effect of medications that may bother some patients. in this paper, we verified practicality of implantable electrical stimulator that can readily change stimulus magnitude and frequency. And this device is possible to stimulate baroreflex or parasympathetic nerve. Therefore we performed in vitro tests and animal experiment for device's operating conditions. This device consist of implantable electrical stimulator and extracorporeal control/monitoring system. Stimulator was designed to make 1Hz~100Hz pulses and it can change continuous or periodic pulse train type. And this device can control stimulator's function and monitor stimulator's status and patients' blood pressure at exterior of body using ZigBee module as wireless telecommunication. We verified that stimulator have error rate under 5% at 50mm depth of organs and, stimulator makes high-efficiency energy with closer position of two electrodes. Also we can confirm the performance of device that decreasing blood pressure and heart rate of a rat by electrical stimulation.

Chopper Application for Magnetic Stimulation

  • Choi, Sun-Seob;Lee, Sun-Min;Kim, Jun-Hyoung;Kim, Whi-Young
    • Journal of Magnetics
    • /
    • 제15권4호
    • /
    • pp.213-220
    • /
    • 2010
  • Since the hypothalamus immediately reacts to a nerve by processing all the information from the human body and the external stimulus being conducted, it performs a significant role in internal secretion; thus, a diverse and rapid stimulus pulse is required. By detecting Zero Detector accurately via the application of AVR on-Chip (ATMEL) using commercial electricity, chopping generates a stimulus pulse to the brain using an IGBT gate to designate a new magnetic stimulation following treatment and diagnosis. To simplify and generate a diverse range of stimuli for the brain, chopping can be used as a free magnetic stimulator. Then, commercial frequency (60Hz) is chopped precisely at the first level of the leakage transformer to deliver an appropriate stimulus pulse towards the hypothalamus when necessary. Discharge becomes stable, and the chopping frequency and duty-ratio provide variety after authorizing a high-pressure chopping voltage at the second level of the magnetic stimulator. These methods have several aims. The first is to apply a variable stimulus pulse via accurate switching frequency control by a voltaic pulse or a pulse repetition rate, according to the diagnostic purpose for a given hypothalamus. Consequently, the efficiency tends to increase. This experiment was conducted at a maximum of 210 W, a magnetic induced amplitude of 0.1~2.5 Tesla, a pulse duration of $200{\sim}350\;{\mu}s$, magnetic inducement of 5 Hz, stimulus frequency of 0.1~60 Hz, and a duration of stimulus train of 1~10 sec.

심부투열용 고주파 치료기의 제작과 RET 전극조건에 따른 온도 분포 특성 (Fabrication of high-frequency therapy device for deep part and temperature distribution characteristic according to electrode condition of RET)

  • 정재원;김병주;김기선
    • 공학기술논문지
    • /
    • 제11권4호
    • /
    • pp.267-271
    • /
    • 2018
  • A high-frequency therapy device with improved output by modifying a high-frequency stimulator was fabricated. The details of the design include generating part design, high-frequency transformer design, large output FET installation, DC voltage input part design and gate input driver design. Based on the real test using the pork meat, the temperature distributions according to the current electric transfer method, penetration depth, electrode diameter size were measured. In the CET method, the penetration depth was 0.5 cm and in the RET method, the penetration depth was 20 cm or more. In addition, it was confirmed that the temperature rise according to the penetration depth in the RET system was substantially constant, and the temperature rise was remarkable as the electrode diameter was small. As a result, it has been confirmed that the high frequency therapy device is highly affected by various conditions of the electrode.

반복적 경두부 자기자극이 운동학습과 뇌 운동영역 활성화에 미치는 영향 : 예비연구 (Effect of rTMS on Motor Sequence Learning and Brain Activation : A Preliminary Study)

  • 박지원;김종만;김연희
    • 한국전문물리치료학회지
    • /
    • 제10권3호
    • /
    • pp.17-27
    • /
    • 2003
  • Repetitive transcranial magnetic stimulation (rTMS) modulates cortical excitability beyond the duration of the rTMS trains themselves. Depending on rTMS parameters, a lasting inhibition or facilitation of cortical excitability can be induced. Therefore, rTMS of high or low frequency over motor cortex may change certain aspects of motor learning performance and cortical activation. This study investigated the effect of high and low frequency subthreshold rTMS applied to the motor cortex on motor learning of sequential finger movements and brain activation using functional MRI (fMRI). Three healthy right-handed subjects (mean age 23.3) were enrolled. All subjects were trained with sequences of seven-digit rapid sequential finger movements, 30 minutes per day for 5 consecutive days using their left hand. 10 Hz (high frequency) and 1 Hz (low frequency) trains of rTMS with 80% of resting motor threshold and sham stimulation were applied for each subject during the period of motor learning. rTMS was delivered on the scalp over the right primary motor cortex using a figure-eight shaped coil and a Rapid(R) stimulator with two Booster Modules (Magstim Co. Ltd, UK). Functional MRI (fMRI) was performed on a 3T ISOL Forte scanner before and after training in all subjects (35 slices per one brain volume TR/TE = 3000/30 ms, Flip angle $60^{\circ}$, FOV 220 mm, $64{\times}64$ matrix, slice thickness 4 mm). Response time (RT) and target scores (TS) of sequential finger movements were monitored during the training period and fMRl scanning. All subjects showed decreased RT and increased TS which reflecting learning effects over the training session. The subject who received high frequency rTMS showed better performance in TS and RT than those of the subjects with low frequency or sham stimulation of rTMS. In fMRI, the subject who received high frequency rTMS showed increased activation of primary motor cortex, premotor, and medial cerebellar areas after the motor sequence learning after the training, but the subject with low frequency rTMS showed decreased activation in above areas. High frequency subthreshold rTMS on the motor cortex may facilitate the excitability of motor cortex and improve the performance of motor sequence learning in normal subject.

  • PDF

좌골신경통을 수반하는 요추부 추간판탈출증 환자에 대한 외이치료의 동통조절 효과 (The Effects of Auriculotherapy for Pain Control in HIVLD with Sciatica)

  • 오영택;권혁철
    • The Journal of Korean Physical Therapy
    • /
    • 제11권3호
    • /
    • pp.45-55
    • /
    • 1999
  • This study was compared with each 2 groups (Intermittent traction therapy alone group1: Control group and Intermittent traction therapy plus Auriculotherapy group 2: Experimental group) on 20 HIVLD(Hemiated Intervertebral Lumbar Disk) patients with sciatics Each subjects were divided to control and experimental. Each group were applied Intermittent traction therapy (HOld:25, Rest:15) for 15 minute and control group were not received auricular stimulation. However experimental groups were applied auricular stimulation simultaneosly. Auricular acupuncture points(max-17, min=13) were stimulated with low frequency. high intensity Electro-Acupunture stimulator for 20 seconds per each point. Treatment and measurements(R.P and VAS) was administered to each patient during the 10 times therapy per 2 weeks. The results were significant differences between the two groups. Experimental group appeared significantly greater than before in pain, and pain relief, and significant improvement in centralization phenomenon of radiating pain.

  • PDF

요추부 추간판탈출증 환자에 대한 외이치료의 동통조절 효과 (Effects of Auriculotherapy in the pain control of HIVLD)

  • 오영택;권혁철
    • 대한물리치료과학회지
    • /
    • 제6권2호
    • /
    • pp.977-988
    • /
    • 1999
  • This study compared the effects of Intermittent traction therapy alone(Group1=Control group) and Intermittent traction therapy plus Auriculotherapy (Group2=Experimental group) to 20 Sciatica patients. Subjects were assigned to two groups with each 10. The two groups received Intermittent traction therapy (Hold:25, Rest:15) for 15 minute and experimental group did received auricular stimulation. Auricular acupuncture points(max=17, min=13) were stimulated with low frequency, high intensity Electro-Acupunture stimulator for 20 seconds per a each point. Treatment and measurements(SLR and VAS) was administered to each patient during the two weeks of 10 times therapy. The results were significant differences between the two groups. Experimental group produced significantly greater pain relief, and significant improvement of limited SLR.

  • PDF