• 제목/요약/키워드: High-frequency noise reduction

검색결과 261건 처리시간 0.03초

질량법칙을 이용한 연료펌프 특정음 저감 방법 (Particular Noise Reduction Method used to Mass Law)

  • 강태식;심재기
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.759-763
    • /
    • 2004
  • High frequency noise of fuel pump has does claimed by user. But high frequency of fuel pump can't heat in the car. But this noise Is an offensive noise outside car. In this study is noise reduction used to mass law. Especially high frequency (for example BPF(blade pass frequency)) is influenced of this law. In detail used to transmission and add to mass according to mass law, reduced particular noise. As a result high frequency is down until can't perception.

  • PDF

냉장고의 이상소음에 관한 사례연구 (Measurement and Control of Abnormal Sound for Refrigerator)

  • 주재만;김중래;이동현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.380-384
    • /
    • 2001
  • The household reftigerator's noise which is closely related with resident environment can hardly be evaluated its sound quality using the Korean Standards. Radiation characteristics of compressor noise consist of tonal noise in low frequency range and, or narrow band noise in high frequency range. In this study, measuring method for detecting the abnormal and low-level noise in high frequency band is presented, and control method for its reduction is proposed. After installing wall which is similar to living condition, we determined a major concerning frequency band of noise. It can be found the directivity of high frequency noise radiated from compressor by using experiment and analysis. According to isolation of noise transfer path, remarkable noise reduction is achieved.

  • PDF

왕복동 압축기의 고주파수 대역 소음 저감 (Noise Reduction of a Reciprocating Compressor in a High Frequency Range)

  • 이진우;이제원;주재만
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.521-526
    • /
    • 2004
  • This paper introduces works performed for reducing high frequency noise of a reciprocating compressor. Noise in a high frequency range strongly affects sound quality as well as increases total noise level of the compressor. In order to reduce the noise, two different works were carried out. the first work was to measure the vibration Power transferred through suspension spring and discharge pipe; and the second one was to obtain operational deflection shape from cross-power spectrum measured on shell. Based on the information, Adequate structural modification of the transfer path and shell resulted in noise reduction in a high frequency range.

  • PDF

400 km/h급 고속철도의 소음저감을 위해 방음벽 상부에 설치하는 소음저감장치 개발에 관한 연구 (A Study on the Development of a Noise Reduction Device Installed at the Top of Noise Barrier for the 400 km/h Class High-speed Railroad)

  • 윤제원;김영찬;장강석;홍병국;엄기영
    • 한국소음진동공학회논문집
    • /
    • 제23권9호
    • /
    • pp.823-830
    • /
    • 2013
  • The purpose of this study is to develop a noise reduction device installed at the top of noise barrier for further decreasing of noise level of 400 km/h class high-speed railroad. For this, the frequency spectrum of 400 km/h class high-speed railroad was analyzed through the field noise test, and the tuning frequency was determined to design a noise reduction device. The noise reduction device was designed to have noise reduction performance of at least 3 dB(A) using the prediction method(2D BEM) and through the laboratory test with the prototype. Finally, the outdoor test showed that this device could decrease noise level of 400 km/h class high-speed railroad even more than 3 dB(A).

마이크로 머플러를 이용한 ODD소음 저감에 관한 연구 (The Study on ODD Acoustic Noise Reduction by Using Micro Muffler)

  • 문병기;차성운;이병희
    • 정보저장시스템학회논문집
    • /
    • 제2권1호
    • /
    • pp.50-55
    • /
    • 2006
  • As high performance and high speed have been accomplished by technology of optical disk drive. optical disk drives have gradually high percentage of the market share in market of storage devices. This technology helps to improve the quality of record/reproduction. However, simultaneously it causes various problems in the structural aspect and increases noise largely. Especially at high speed, dominant noise is more influenced by fluid noise than by structure-borne noise. The purpose of this study is that reduce the air-born noise in optical disk drive as it decreases a quantity of flow by using a micro muffler. The micro muffler is a miniaturized muffler. The muffler is used widely by solution to reduce air-borne noise which is generated by flow. According to frequency band of the noise source, it can be applied by muffler of various forms. In this study, we examined the acoustic characteristics of the micro muffler and applied it to reduction of the ODD noise. It could get an excellent noise reduction in high frequency band through the decrease of an inner flow. But it could not get a noise reduction in low frequency band.

  • PDF

마이크로 머플러를 이용한 ODD소음 저감에 관한 연구 (The Study on ODD Acoustic Noise Reduction by Using Micro Muffler)

  • 문병기;차성운;이병희
    • 정보저장시스템학회:학술대회논문집
    • /
    • 정보저장시스템학회 2005년도 추계학술대회 논문집
    • /
    • pp.197-202
    • /
    • 2005
  • Current Optical Disk drive is dominating high share gradually in information storage device market through development of great skill. These technologies can achieve not only improvement of transmission speed but also elevation of recording/reproduction technology. However, these present state cause not only the increase of vibration in structural viewpoint but also problem of serious noise while the ODD becomes high speed/high performance. Specially, air-born noise is being bigger than structural-born noise as disk rotation speed increases gradually. The object of this research is that reduce the air-born noise in optical disk drive by reducing a quantity of flow by using a miniaturized muffler. The micro muffler is a miniaturized muffler. The muffler is used widely by solution to reduce air-born noise which is generated by flow. According to frequency band of the noise source, it can be applied by muffler of various forms. In this research, we examined the noise characteristics of the micro muffler and applied it by noise reduction solution of the ODD. It could get an excellent noise reduction in high frequency band by using the micro muffler than the opened case through the decrease of an inner flow. But it could not get a noise reduction in low frequency band through the decrease of an inner flow.

  • PDF

공동주택 변기 배수소음 저감 방안에 관한 연구 (A Study on reduction of drainage noise for water closet)

  • 김인수;고철수;문재호;한문성;심경석;이준서
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.881-885
    • /
    • 2001
  • The study about a drainpipe of water closet was performed as reduction of drainage noise for water closet. The Drainage noise is composed two characteristics. One is Low frequency noise and the other is high frequency noise. Low frequency noise is dominant in the first stage and high frequency noise is dominant in the last stage. This is due to water splashing and that is caused by formation of chamber pot. In this experiment, for the purpose for reducing the noise, we choose the hollow rubber pipe element. As a result, we reduced drainage noise about 11㏈A.

  • PDF

스피커를 이용한 400km/h급 고속철도 소음저감용 방음벽 상단장치의 음향성능 시험방법에 관한 연구 (A study on the acoustic performance test method using speaker of a noise reduction device for noise reduction of the 400km/h class high-speed railroad)

  • 윤제원;김영찬;장강석;엄기영;장승호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 춘계학술대회 논문집
    • /
    • pp.625-629
    • /
    • 2014
  • For the purpose of the acoustic performance evaluation of noise reduction device(NRD) installed at the top of noise barrier for further decreasing of noise level of 400km/h class high-speed railroad(HEMU), the acoustic performance test method using speaker instead of really running railway vehicle was suggested in this paper. For this, noise source location and frequency spectrum of HEMU was analyzed through the field noise test. These data were used for the determination of speaker's installation positions and frequency correction values applied to the speaker noise source. And, 400 meters long NRD was installed at the site where HEMU will be running at a speed of 400km/h. Finally, the outdoor speaker test with and without NRD showed that this NRD could decrease noise level even more than 3dB(A). In the future, the acoustic performance results of NRD conducted with speaker test will be compared with that of field test for HEMU running at a speed of 400km/h.

  • PDF

Noise-reduction Function and its Affecting Factors of Plant Communities

  • Song, Xiu-hua;Wu, Qian-qian;Yu, Dong-ming;PIAO, Yong-ji;Cho, Tae-Dong
    • 한국환경과학회지
    • /
    • 제25권10호
    • /
    • pp.1407-1415
    • /
    • 2016
  • In this study, we investigated the relationship between noise reduction and the community structure of nine groups of typical plant communities as well as the reduction in noise at different frequencies. The semantic differential method was adopted to explore the perception of noise reduction. The results indicated that there was a significantly positive correlation between noise reduction and coverage, a significantly negative correlation between noise reduction and bifurcate height, and a negative correlation between noise reduction and bare rate. However, there was no significant correlation between noise reduction and height, diameter at breast height, or crown width. The reduction of middle-frequency noise was better than that of low- and high-frequency noise. The indicators "quiet" and "calm" showed that plant communities could reduce the noise perceived by humans. However, overly dense woodland caused nervousness, fear, depression, and other negative effects. Relatively open environments and those with large forest gaps obtained the highest evaluation.

압전 션트를 이용한 패널의 투과소음 저감 성능에 관한 연구 (Performance test for transmitted noise reduction of smart panel using piezoelectric shunt damping)

  • 최진영;김재환;이중근
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.1120-1125
    • /
    • 2001
  • A new concept of piezoelectric smart panels for noise reduction in wide band frequencies is proposed and their possibility is experimentally investigated. Multi-mode damping is studied by using a newly proposed tuning method. The proposed panels are based on passive shunt damping methods. This method is based on electrical impedance model and maximizing the dissipated energy at the shunt circuit. four PZT are attached on smart panel for improving performance of transmission noise reduction. 0 prove the concept of piezoelectric smart panels, an acoustic measurement experiment was performed. The smart panels exhibit a good noise reduction in middle and high frequency ranges due to the mass effects of absorbing materials or/and the air gap. The use of piezoelectric smart panel renders noise reduction at resonance frequency. Noise reduction at multiple resonance frequencies is experimentally investigaed.

  • PDF