Study on interrupting test method for class S2 circuit breaker of distribution system (배전용 S2급 차단기의 차단 성능평가 시험법에 관한 연구)

  • Park, Byung-Rak;Jo, Man-Yong;Kim, Jin-Seok;Shin, Hee-Sang;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.8
    • /
    • pp.132-139
    • /
    • 2011
  • Technical requirements for medium voltage class circuit breaker were harmonized by IEC and IEEE, and IEC newly adopted the requirements for class S2 circuit-breaker for overhead-line with the ratings of high-frequency TRV(Transient Recovery Voltage), which IEEE already adopted. Under these circumstances, KERI(Korea Electrotechnology Research Institute) studied testing technologies and facilities, which enable to perform interrupting capacity tests for class S2 circuit-breaker. As results, KERI could carry out interrupting capacity tests for medium voltage class circuit breaker rated up to 3-phase 52[kV] 40[kA], which satisfies the IEC standard.

Virus-induced Gene Silencing as Tool for Functional Genomics in a Glycine max

  • Jeong, Rae-Dong;Hwang, Sung-Hyun;Kang, Sung-Hwan;Choi, Hong-Soo;Park, Jin-Woo;Kim, Kook-Hyung
    • The Plant Pathology Journal
    • /
    • v.21 no.2
    • /
    • pp.158-163
    • /
    • 2005
  • Virus-induced gene silencing (VIGS) is a recently developed gene transcript suppression technique for characterizing the function of plant genes. However, efficient VIGS has only been studied in a few plant species. In order to extend the application of VIGS, we examined whether a VIGS vector based on TRV would produce recognizable phenotypes in soybean. Here, we report that VIGS using the Tobacco rattle virus (TRV) viral vector can be used in several soybean cultivars employing various agro-inoculation methods including leaf infiltration, spray inoculation, and agrodrench. cDNA fragments of the soybean phytoene desaturase(PDS) was inserted into TRV RNA-2 vector. By agrodrench, we successfully silenced the expression of PDS encoding gene in soybean. The silenced phenotype of PDS was invariably obvious 3 weeks after inoculation with the TRV-based vector. Real-time RT-PCR analyses showed that the endogenous level of GmPDS transcripts was dramatically reduced in the silenced leaf tissues. These observations confirm that the silenced phenotype is closely correlated with the pattern of tissue expression. The TRV-based VIGS using agrodrench can be applied to functional genomics in a soybean plants to study genes involved in a wide range of biological processes. To our knowledge, this is the first high frequency VIGS method in soybean plants.

Surge Characteristics Analysis of Three-phase Virtual Chopping at Vacuum Circuit Breaker (진공차단기 3상 동시 차단시의 서지 특성 분석)

  • Kim, Jong-Gyeum
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.9
    • /
    • pp.1159-1164
    • /
    • 2018
  • Vacuum circuit breakers(VCB) are widely used for current interruption of high-voltage inductive loads such as induction motors. This VCB can be chopped off before the current zero due to its high arc-extinguishing capability. One of the outstanding features of VCB is that it can cut off high frequency re-ignition current more than other circuit breakers. If the transient recovery voltage generated in the arc extinguishing is higher than the dielectric strength of the circuit breaker, a re-ignition phenomenon occurs. The surge voltage of the re-ignition is very high in magnitude and the steepness of the waveform is so severe that it can act as a high electrical stress on the winding. If the high frequency current of one phase affects the other two phases when the re-ignition occurs, it may cause a high surge voltage due to the virtual current chopping. If the magnitude of the voltage allowed in the motor winding is high or the waveform level is too severe, it may lead to insulation breakdown. Therefore, it is necessary to reduce the voltage to within a certain range. In this study, we briefly explain the various phenomena at the time of interruption, analyzed the magnitude of the dielectric strength and the transient recovery voltage at the simultaneous three-phase interruption that can give the greatest influence to the inductive load, proposed a method to reduce the impact.