• 제목/요약/키워드: High-frequency PWM noise

검색결과 53건 처리시간 0.024초

부분 공진형 소프트 스위칭 PWM DC-DC 고전압 컨버터 (Soft-Switched PWM DC-DC High-Power Converter with Quasi Resonant-Poles and Parasitic Reactive Resonant Components of High-Voltage Transformer)

  • 김용주;신대철
    • 전력전자학회논문지
    • /
    • 제4권4호
    • /
    • pp.384-394
    • /
    • 1999
  • This paper deals with a fixed frequency full-bridge inverter type DC-DC high-power converter with high frequency high voltage(HFHV) transformer-coupled stage, which operates under quasi-resonant ZVS transition priciple in spite of a wide PWM-based voltage regulation processing and largely-changed load conditions. This multi-resonant(MR) converter topology is composed of a series capacitor-connected parallel resonant tank which makes the most of parasitic circuit reactive components of HFHV transformer and two additional quasi-resonant pole circuits incorporated into the bridge legs. The soft-switching operation and practical efficacy of this new converter circuit using the latest IGBTs are actually ascertained through 50kV trially-produced converter system operating using 20kHz/30kHz high voltage(HV) transformers which is applied for driving the diagnostic HV X-ray tube load in medical equipments. It is proved from a practical point of view that the switching losses of IGBTs and their electrical dynamic stresses relating to EMI noise can be considerably reduced under a high frequency(HF) switching-based phase-shift PWM control process for a load setting requirements.

  • PDF

제동장치에서 고주파수 PWM 제어에 의한 맥동특성 연구 (Study on the Characteristics of Surge Pressure by High Frequency PWM Control in Braking System)

  • 김병우
    • 한국정밀공학회지
    • /
    • 제25권3호
    • /
    • pp.109-114
    • /
    • 2008
  • The solenoid valve of ABS hydraulic modulator is a two directional on-off valve and is controlled by around 100Hz on-off control. When the on-off valve is switched from open state to closed state, there are braking force deterioration, noise and vibration due to surge pressure in the wheel cylinder. In this study, identifies surge pressure in the braking process of ABS, and investigates the way to reduce the phenomenon. To reduce the surge pressure, PWM(Pulse Width Modulation) control with high frequency of 20kHz was attempted. In conclusion, by using the results of this study for the pressure surge prediction, we could expect enhancement of braking performance in ABS.

소프트 스위칭 방식을 이용한 X-Ray용 DC-DC Converter에 관한 연구 (A Study on DC-DC Converter for X-Ray Using Soft-Switching Method)

  • 김학성;김현준;원충연;유동욱;하성운
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.379-381
    • /
    • 1994
  • This paper is concerned with a zero-voltage soft-switching PWM DC-DC high-pelter converter using IGBTs, which Bakes the most of the parastic LC parameters of high-voltage transformer link, for diagnostic X-Ray power generator. The converter circuit basically utilizes phase-shift pulse width modulated series resonant full-bridge PWM DC-DC high-Power converter operating at a constant frequency:20kHz. This technique brings about dramatic decreases in the switching losses of power devices and their electrical stresses as compared with the commonly-used hard-switching PWM DC-DC power converter. The high-frequency switching operation of the converters has some effective advantages, which consist in the physical reduction in size and weight and lowered acoustic noise.

  • PDF

2진 스위칭 주파수 변조에 의한 PWM 컨버터의 EMI 저감 (EMI reduction of PWM converter By Binary Switching Frequency Modulation)

  • 진인수;박석하;양경록;김양모
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2650-2652
    • /
    • 1999
  • To satisfy the demand for small size, light weight. high density power supply, the switching frequency of DC/DC converters has been increased. The PWM control of the conventional SMPS have a switching frequency that a level of the conducted noise spectra contribute to switching frequency band. So the electronic equipment is not only affected from that but is restricted to internal regulation like CISPR, FCC, and VDE. In this paper, we analyzed Bi-FM. Bi-FM is two fixed switching frequency with a modulation frequency. So emission spectrum of Bi-FM control signal is spreaded and spectral power level is reduced. In this paper, we analyze the spectral analysis of Bi-FM control signal and the spectral comparison between the PWM control and Bi-FM control. And we confirm that reduced the spectrum power level through simulation using Pspice and experiment.

  • PDF

진동 특성 파악을 통한 인버터 에어컨의 운전 주파수 및 파이프 형상 결정 (Determination of the Operating Frequency and Pipe Design of Inverter Air-conditioner considering Dynamic Characteristics of Inverter Rotary Compressor)

  • 모진용;이진교;박득용;김진섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 I
    • /
    • pp.203-206
    • /
    • 2001
  • The reduction of chopping noise generated from inverter compressor and the piping design reducing vibration are the most important items in the quality of air conditioner. The chopping noise is identified by the study of the relationship between carrier frequency and natural frequency of the compressor shell. The high carrier frequency is the key factor in reduction of carrier noise. To keep the natural frequencies of the system as far as away from the operating frequencies appears to be the most important factor in the design of piping system.

  • PDF

Modeling of a novel power control scheme for Photovoltaic solar system

  • Park, Sung-Joon
    • Journal of information and communication convergence engineering
    • /
    • 제6권4호
    • /
    • pp.417-420
    • /
    • 2008
  • Solar electric systems have very little impact on environment, making them one of the cleanest power-generating technologies available. While they are operating, PV systems produce no air pollution, hazardous waste, or noise, and they require no transportable fuels. In PV system design, the selection and proper installation of appropriately-sized components directly affect system reliability, lifetime, and initial cost. In this research, we have studied the PWM(Pulse Width Modulation) signals. I proposed an efficient photovoltaic power interface circuit incorporated with a DC-DC converter and a sine-pwm control method full-bridge inverter. In grid-connected solar power systems, the DC-DC converter operates at high switching frequency to make the output current a sine wave, whereas the full-bridge inverter operates at low switching frequency which is determined by the ac frequency. Thus, it can reduce the switching losses incurred by the full-bridge inverter. Full-bridge converter is controlled by using microprocessor control method, and its operation is verified through computer aided simulations.

Random PWM 기법을 이용한 전도노이즈 저감 (A study on the Conducted Noise Reduction in Random PWM)

  • 정동효
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.154-158
    • /
    • 2006
  • The switching-mode power converter has been widely used because of its features of high efficiency and small weight and size. These features are brought by the ON-OFF operation of semiconductor switching devices. However, this switching operation causes the surge and EMI(Electromagnetic Interference) which deteriorate the reliability of the converter themselves and entire electronic systems. This problem on the surge and noise is one of the most serious difficulties in AC-to-DC converter. Random Pulse Width Modulation (RPWM) is peformed by adding a random perturbation to switching instant while output-voltage regulation of converter is performed. RPWM method for reducing conducted EMI in single switch three phase discontinuous conduction mode boost converter is presented. The more white noise is injected, the more conducted EMI is reduced. But output-voltage is not sufficiently regulated. This is the reason why carrier frequency selection topology is proposed. In the case of carrier frequency selection, output-voltage of steady state and transient state is fully regulated. A RPWM control method was proposed in order to smooth the switching noise spectrum and reduce it's level. Experimental results are verified by converter operating at 300v/1kW with $5%{\sim}30%$ white noise input. Spectrum analysis is performed on the Phase current and the CM noise voltage. The former is measured with Current Probe and the latter is achieved with LISN, which are connected to the spectrum analyzer respectively.

  • PDF

영전류 스위칭 방식의 보조스위치를 갖는 새로운 영전압 스위칭 방식의 PWM 컨버터 (A New Zero-Voltage-Switching PWM Converters with Zero-Current-Switched Auxiliary Switch)

  • 마근수;홍일희;김양모
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권12호
    • /
    • pp.632-640
    • /
    • 2003
  • In conventional Zero-Voltage-Transition(ZVT) PWM converters, zero-voltage turn-on and turn-off for main switch without increasing voltage/current stresses is achieved at a fixed frequency. The switching loss, stress, and noise, however, can't be minimized because they adopt auxiliary switches turned off under hard-switching condition. In this paper, new ZVS-PWM converters of which both active and passive switches are always operating with soft-switching condition are proposed. Therefore, the proposed ZVS-PWM converters are most suitable for avionics applications requiring high-power density. Breadboarded ZVS-PWM boost converters using power MOSFET are constructed to verify theoretical analysis.

새로운 영전류 스위칭 방식의 PWM 컨버터 (New Zero-Current-Switching PWM Converters)

  • 마근수;김양모
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권9호
    • /
    • pp.467-472
    • /
    • 2001
  • In conventional zero-current-switching(ZCS) PWM converters, zero-current turn-off for main switch without increasing voltage/current stresses is achieved at a fixed frequency. The switching loss, stress, and noise, however, can\`t be minimized because they adopt auxiliary switches turned off and main switches turned on under hard-switching condition. In this paper, new ZCS-PWM converters of which all switches are always operating with soft-switching condition are proposed. Therefore, the proposed ZCS-PWM converters are most suitable for systems requiring high-power density Breadboarded ZCS-PWM boost converters using power MOSFET are constructed to verify theoretical analysis.

  • PDF

Output filter design for conducted EMI reduction of PWM Inverter-fed Induction Motor System

  • Kim Lee-Hun;Won Chung-Yuen;Kim Young-Seok;Choi Se-Wan
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.761-767
    • /
    • 2001
  • In this paper, filtering techniques to reduce the adverse effects of motor leads on high-frequency PWM inverter fed AC motor drives will be examined. The filter was designed to keep the motor terminal from the cable surge impedance to reduce overvoltage reflections, ringing, and the dv/dt, di/dt. Therefore, filtering techniques are investigated to reduce the motor terminal overvoltage, ringing, and EMI noise in inverter fed ac motor drive systems. The output filter is used to limit the rate of the inverter output voltage and reduce EMI(common mode noise) to the motor. The performance of the output filter is evaluated through simulations (PSIM) and experiment on PWM inverter-fed ac motor drive(3phase, 3hp(2.2kw), input voltage 220/380V, induction motor). An experimental PWM drive system reduction of conducted EMI was implemented on an available TMS320C31 microprocessor control board. Finally, experimental results showed that the inverter output filter reduces more CM noise than the LPF(low pass filter) and reduce overvoltage and ringing at the motor terminal.

  • PDF