• Title/Summary/Keyword: High-field MR

Search Result 137, Processing Time 0.021 seconds

Performance Estimation of Magneto-rheological Brake with Different Magnetic Core Shapes (자기 코어 형상에 따른 MR 브레이크의 성능 예측)

  • Park, Jiong Min;Choi, Seung-Bok;Sohn, Jung Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.27 no.2
    • /
    • pp.175-181
    • /
    • 2017
  • In the present work, to achieve high braking performance with restricted size, characteristics of magneto-rheological (MR) fluid brake is numerically investigated considering different magnetic core shapes. As a first step, structural configuration of the MR brakes are proposed with four different magnetic core shapes, such as single flat, single inclined, dual flat and dual inclined. To estimate braking performance of the proposed MR brakes, electromagnetic analysis is carried out and the results of magnetic field intensity distribution are observed. Based on the electromagnetic analysis results, braking torque of the MR brake is estimated according to magnitude of current input and results are discussed. It is observed that enhanced braking torque can be achieved by adopting the modified magnetic core shape under limited small size of the MR brake.

State-of-the-art of semiactive control systems using MR fluid dampers in civil engineering applications

  • Jung, H.J.;Spencer, B.F. Jr.;Ni, Y.Q.;Lee, I.W.
    • Structural Engineering and Mechanics
    • /
    • v.17 no.3_4
    • /
    • pp.493-526
    • /
    • 2004
  • Semiactive control systems have received considerable attention for protecting structures against natural hazards such as strong earthquakes and high winds, because they not only offer the reliability of passive control systems but also maintain the versatility and adaptability of fully active control systems. Among the many semiactive control devices, magnetorheological (MR) fluid dampers comprise one particularly promising class. In the field of civil engineering, much research and development on MR fluid damper-based control systems has been conducted since this unique semiactive device was first introduced to civil engineering applications in mid 1990s. In 2001, MR fluid dampers were applied to the full-scale in-service civil engineering structures for the first time. This state-of-the-art paper includes a detailed literature review of dynamic models of MR fluid dampers for describing their complex dynamic behavior and control algorithms considering the characteristics of MR fluid dampers. This extensive review provides references to semiactive control systems using MR fluid dampers. The MR fluid damper-based semiactive control systems are shown to have the potential for mitigating the responses of full-scale civil engineering structures under natural hazards.

The Fabrication and Reproducing Signal Characteristics of Tri-layered Magnetoresistance Element (3층 자기저항소자의 제작 및 재생신호특성)

  • 김용성;노재철;박현순;서수정;김기출;송용진
    • Journal of the Korean Magnetics Society
    • /
    • v.8 no.4
    • /
    • pp.231-240
    • /
    • 1998
  • We investigated that the fabrication and reproducing signal characteristics of tri-layered magnetoresistance (MR) element for the high density magnetic thin film heads and sensors. Magnetoresistance curve of tri-layered MR element predicted by computer modeling was saturated above external field of -15 Oe~+22 Oe, and it was shifted to linearized region as large as 4 Oe. In the case of fabricated real device, magnetoresistance curve was saturated above external field of $\pm$15 Oe, and it was shifted to linearized region as large as 4 Oe. As shown in real device, MR response curve was in good agreement with the simulation results. As a result of experimental data of reproducing output signal in real device, it retained normal sinusoidal waveforms in 1~4 Oe external magnetic field. In this magnetic field region, the fabricated heads with tri-layered MR element can be operated with good reproduced characteristics. This will be beneficial to the use of efficient processes of manufacturing elements and the vacuum deposition techniques which control thin film properties.

  • PDF

A Study on the Characteristics of Material removal using a Round endmill Type MR Polishing System for 3D Shape (3차원 형상 연마를 위한 라운드 엔드밀 타입 MR연마시스템의 재료제거 특성에 관한 연구)

  • Hong, Kwang-Pyo;Shin, Bong-Cheol;Kim, Dong-Woo;Cho, Myeong-Woo;Je, TAe-Jin
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.5
    • /
    • pp.632-638
    • /
    • 2011
  • Recently, it has been studying for the polishing process of micro parts widely. However, present MR polishing system, it is difficult to minimize electromagnet and to polish sphere or slope parts. Then, it can not be obtained demanded surface quality. In this study, material removal characteristics of BK7 glass using round endmill type MR polishing system were investigated through series of experiment. The experiments were investigated by changing imposed polishing conditions, such as rotational speed and polishing depth. As a results, very high material removal was obtained at 0.7mm gap distance, 1,980rpm.

The Low-field Tunnel-type Magnetoresistance Characteristics of Thin Films Deposited on Different Substrate (기판 효과에 따른 저 자장 영역에서의 자기저항 효과에 관한 연구)

  • Lee, Hi-Min;Shim, In-Bo;Kim, Chul-Sung
    • Journal of the Korean Magnetics Society
    • /
    • v.12 no.2
    • /
    • pp.41-45
    • /
    • 2002
  • The low-field tunnel-type magnetoresistance (MR) properties of sol-gel derived $La_{0.7}Pb_{0.3}MnO_3(LPMO)$ thin film deposited on different substrate have been investigated. Polycrystalline thin films were fabricated by spin-coating on $SiO_2/Si(100)$ substrate and that with yttria-stabilized zirconia (YSZ) buffer layer, while c-axis-oriented thim film was grown on $LaAlO_3(001)$ (LAO) single crystal substrate. The full width half maximum (FWHM) of the rocking curve scan of LPMO/LAO film is $0.32^{\circ}$. Tunnel-type MR ratio is 0.52 % in $LPMO/SiO_2/Si$(100) film and that of $LPMO/YSZ/SiO_2/Si$(100) film is as high as 0.68 %, whereas that of LPMO/LAO(001) film is less than 0.4 % under the applied field of 500 Oe at 300 K. Well-pronounced MR hysteresis was registered with an MR peak in the vicinity of the coercive field. The low-field tunnel-type MR characteristics of thin films deposited on different substrates originates from the behavior of grain boundary properties.

Basic RF Coils Used in Multi-channel RF Coil and Its B1 Field Distribution for Magnetic Resonance Imaging System (자기공명영상 촬영 장치에서 다채널 RF Coil에 이용되는 기본 구조 RF Coil의 B1 Field 분석)

  • Kim, Yong-Gwon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.12
    • /
    • pp.4891-4895
    • /
    • 2010
  • RF coil is an important component of the Magnetic Resonance Imaging (MRI) system and the performance of RF coil is one of major factors for high SNR images. Sensitivity and RF field uniformity are parameters for evaluating RF coil performance. Since the B1 field is induced by RF coil, MR signal is strongly affected by RF coil structure and arrangement. In receiving MR signal, the RF coil sensitivity to MR Signal is also determined by the induced B1 field of RF coil. Therefore, the spatial distribution of B1 field must be verified. In this work, we performed computer simulation of the basic RF coil structures using Matlab and verified their sensitivity and uniformity through their B1 field distribution. This work will be useful for the advanced multi-channel RF coil design.

3D Non-Rigid Registration for Abdominal PET-CT and MR Images Using Mutual Information and Independent Component Analysis

  • Lee, Hakjae;Chun, Jaehee;Lee, Kisung;Kim, Kyeong Min
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.4 no.5
    • /
    • pp.311-317
    • /
    • 2015
  • The aim of this study is to develop a 3D registration algorithm for positron emission tomography/computed tomography (PET/CT) and magnetic resonance (MR) images acquired from independent PET/CT and MR imaging systems. Combined PET/CT images provide anatomic and functional information, and MR images have high resolution for soft tissue. With the registration technique, the strengths of each modality image can be combined to achieve higher performance in diagnosis and radiotherapy planning. The proposed method consists of two stages: normalized mutual information (NMI)-based global matching and independent component analysis (ICA)-based refinement. In global matching, the field of view of the CT and MR images are adjusted to the same size in the preprocessing step. Then, the target image is geometrically transformed, and the similarities between the two images are measured with NMI. The optimization step updates the transformation parameters to efficiently find the best matched parameter set. In the refinement stage, ICA planes from the windowed image slices are extracted and the similarity between the images is measured to determine the transformation parameters of the control points. B-spline. based freeform deformation is performed for the geometric transformation. The results show good agreement between PET/CT and MR images.

Thermal Stability and High Exchange Coupling Field of Bottom Type IrMn-Pinned Spin Valve (Bottom형 IrMn 스핀밸브 박막의 열적안정성과 높은 교환결합력)

  • Hwang, J.Y.;Kim, M.Y.;Rhee, J.R.
    • Journal of the Korean Magnetics Society
    • /
    • v.12 no.2
    • /
    • pp.64-67
    • /
    • 2002
  • IrMn pinned spin valve (SV) films with stacks of Ta/NiFe/IrMn/CoFe/Cu/CoFe/NiFe/Ta were prepared by dc sputtering onto thermally oxidized Si (111) substrates at room temperature under a magnetic field of about 100 Oe. The annealing cycle number and temperature dependence of exchange coupling field (H$_{ex}$), magnetoresistance (MR) ratio, and coercivity (H$_{c}$) were investigated. By optimizing the process of deposition and post thermal annealing condition, we obtained the IrMn based SV films with MR ratio of 3.6%, H$_{ex}$ of 1180 Oe for the pinned layer. The H$_{ex}$ is stabilized after the second annealing cycle and it is thought that this SV reveals high thermal stability. The H$_{ex}$ maintained its strength of 600 Oe in operation up to 24$0^{\circ}C$ and decreased monotonically to zero at 27$0^{\circ}C$.

Evaluation of Hydration Effect on Human Skin by $^1H$ MRS at 14.1T

  • Choi Chi-Bong;Hong Sung-Tak;Choe Bo-Young;Woo Dong-Chul;Yoon Seong-Ik;Cho Ji-Hyun;Lee Chul-Hyun;Cheong Chae-Joon;Park Sang-Yong;Oh Chil-Hwan
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.10 no.1
    • /
    • pp.105-114
    • /
    • 2006
  • Purpose: We achieved high resolution MR imaging and spectra of human skin in vitro with using a 14.1 T MRI/MRS system, and evaluated the hydration effect of various cosmetic products by measuring the skin's. moisture concentration. Materials and Methods: We used the Bruker 14.1 T MRI/MRS system with a vertical standard bore that was equipped with a DMX spectrometer gradient system (200 G/cm at a maximum 40 A), RF resonators (2, 5 and 10 mm) and Para Vision software. Spin echo and fast spin echo pulse sequences were employed for obtaining the high resolution MR images. The 3D-localized point resolved spectroscopy (PRESS) method was used to acquire the MR spectra. Results: The high resolution MR images and spectra of human skin in vitro were successfully obtained on a 14.1 T system. The water concentration of human skin after applying a moisturizer was higher than that before applying a moisturizer. Conclusions: The present study demonstrated that the high-resolution MR images and spectra of human skin from a high field NMR instrument could be applicable to evaluating the hydration state of the stratum corneum.

  • PDF

Assessment of Malignancy in Brain Tumors by 3T MR Spectroscopy

  • 최보영;전신수;김범수;이재문;정성택;안창범;오창현;김선일;이형구
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.84-84
    • /
    • 2003
  • Purpose: To assess clinical proton MR spectroscopy (MRS) as a noninvasive method for evaluating tumor malignancy at 3T high field system. Materials and methods: Using 3T MRI/MRS system, localized water-suppressed single-voxel technique in patients with brain tumors was employed to evaluate spectra with peaks of N-acetyl aspartate (NAA), choline-containing compounds (Cho), creatine/phosphocreatine (Cr) and lactate. On the basis of Cr, these peak areas were quantificated as a relative ratio.

  • PDF