• 제목/요약/키워드: High-efficiency induction motor

검색결과 162건 처리시간 0.026초

Decoupled Control of Induction Motors for Both High Power Efficiency and High Dynamic Performancea

  • Kim, Dong-Il;Ko, Myoung-Sam;Ha, In-Joong;Park, Jae-Wha
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1988년도 한국자동제어학술회의논문집(국제학술편); 한국전력공사연수원, 서울; 21-22 Oct. 1988
    • /
    • pp.852-857
    • /
    • 1988
  • In induction motor control, power efficiency as well as high dynamic performance is important. We attempt to achieve both of them by decoupled control of rotor speed and flux. A nonlinear feedback controller with a well-known rotor flux observer is proposed with its stability analysis. Experimental results demonstrate that the proposed control method based on recently developed nonlinear feedback control theory is of practical use.

  • PDF

유도전동기의 자기적 포화가 가변속 제어의 효율에 미치는 영향 (Effect for Eefficiency of Variable Speed Control of Magnetic Saturation in Induction Machine)

  • 정종호;윤서진;이은웅;문제연
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.52-54
    • /
    • 1998
  • In this paper, analytically presented the magnetic saturation impact on the efficiency of induction motor. Especially, in this study concerned with various cases such as included magnetic saturation, constant flux.

  • PDF

Design of Self-Starting Hybrid Axial Flux Permanent Magnet Synchronous Motor Connected Directly to Line

  • Eker, Mustafa;Akar, Mehmet;Emeksiz, Cem;Dogan, Zafer;Fenercioglu, Ahmet
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권5호
    • /
    • pp.1917-1926
    • /
    • 2018
  • In view of the current state of the reserves of electric energy generated resources and the share of electric motors in electricity consumption, many researches and studies related to efficiency in electric motors are being made. The presented work is related to the Axial Flux Permanent Magnet Synchronous Motor (AF-PMSM), which has recently undergone significant work based on the development of magnet and motor technology. In this study, a novel AF-PMSM was designed analytically through Finite Element Method (FEM) which can be started by connecting to a line such as an asynchronous motor in a transient state and can operate with high efficiency and power factor after synchronization in steady state without the need for an expensive motor drive. According to the obtained FEM results, a design with an efficiency class of IE4 of 5.5 kW shaft power, a 4 poles motor was obtained. As a result, economic calculations indicate that the extra cost of the designed Line start AF-PMSM with respect to the asynchronous motor is rapidly compensated by energy saving due to a more efficient operation, especially constant speed operations. As a result of the analysis obtained, the targeted values are reached. For induction motors and radial flux permanent magnet synchronous motors, a good alternative motor that can operate with high efficiency and power factor has been obtained.

고효율 유도 전동기 소형 모터코어 금형개발 (Development of Small Motor Core Die for High Efficiency Induction Motor)

  • 임세종;최계광
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2009년도 춘계학술발표논문집
    • /
    • pp.249-251
    • /
    • 2009
  • 고효율 유도전동기는 일반 유도전동기의 발생 손실을 절감시킨 것으로 적은 소비전력으로 에너지를 절약하고, 운전비용이 낮아서 단기간에 초기 설비투자 비용회수가 가능하고, 온도상승이 크지 않아 전동기 수명을 연장시킬 수 있다. 이에 포스코아에서는 이제까지의 경험을 바탕으로 전기 연구원과 협력하여 고효율 유도전동기 개발에 나섰다. 본 논문에서는 고효율 유도전동기 소형모터금형개발에 관하여 연구하였다.

  • PDF

A Performance of Single Phase Switched Reluctance Motor having both Radial and Axial air gap

  • 임준영;정윤철;권경안
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.184-188
    • /
    • 1999
  • Switched Reluctance Motor has doubly salient poles in stator and rotor, windings are wound in just stator and no magnet or windings on the rotor. This configuration is robust mechanically and thermally. The inverter of SRM is more robust than that of induction or brushless DC(BLDC) motor, but still its drive is comparatively expensive for home appliance. To drive the conventional three or four-phase SRM, 6 to 8 power switches are required when asymmetric bridge inverter is employed. Generally, more than 50% of the cost for the SRM drive is allocated to power devices and gate drives. This paper proposed single phase SRM that have both radial and axial air gaps. The stator and rotor were stacked with two types of stampings that have different diameters. This configuration is very effective to increase align inductance(Lmax). The high value of Lmax increases the motor efficiency and power density. The proposed single phase SRM(Claw SRM) can be driven by only two power switches. To show the validity of the proposed idea, the analysis using finite element method(FEM) and experimental works are carried out. The proposed SPSRM can be driven with high efficiency and can be made compactly and inexpensively because of high value of align inductance and less number of switches. For the comparison, we used same stator for three-phase and single phase, and slightly different stator and rotor for proposed single phase SRM(Claw SRM)

  • PDF

한국형 고속전철용 견인전동기의 포화현상에 따른 특성연구 (A Study on The characteristics based on the stauration effects of traction motor for korea High Speed Train)

  • 이상우;김근웅;윤종학;한성수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1999년도 추계학술대회 논문집
    • /
    • pp.360-367
    • /
    • 1999
  • An inverter-driven induction motor is used as the traction motor for a high speed drive system that required safety, reliabillity, performance, compact size owing to the space and weight alloted for attaching to train, etc. particularly it is possible to happen the saturation effects of flux density at constant voltage-frequency region and then increase very higher than the at lowed capacity of no-load current and temperature in any case. therefore the optimum design of core, optimum voltage-frequency ratio, adoption of high grade magnetic core have been developed and researched for preventing these problems. this paper show the saturation effects of traction rotor by measuring the induced voltage of search coil at stator teeth and presents optimum voltage-frequency ratio as well as optimum core design through the comparison with efficiency, power factor, load current and no-load current for korea high speed train.

  • PDF

수치해석에 의한 고효율 BLDC 모터의 제어기 설계 및 성능평가에 관한 연구 (The Performance Evaluation and the Design of Controller for the Highly Efficient BLDC Motor using Numerical Analysis)

  • 우천희;박건식
    • 전기학회논문지P
    • /
    • 제55권2호
    • /
    • pp.62-66
    • /
    • 2006
  • This thesis focuses on the design of control schemes for highly efficient BLDC motor drive applications using drives with output capacity of 1Hp. The control system was designed and implemented on a PIC micro-controller and applied to an electric vehicle as a viable replacement to the existing a high phase induction motor that is currently being used for these low cost, small traction drive applications. This paper for the brushless drive research has shown the optimization of the drive system for improved drive design and switching techniques that can improve the entire drive system efficiency for electric vehicle both large and small traction applications using sinusoidal PWM techniques for synthesizing the AC waveforms needed to control these traction drives. In addition, Numerical simulation was conducted to evaluate the performance of designed BLDC Motor using MotorPro simulator.

Test Result Analysis of a 1MW HTS Motor for Industry Application

  • Baik, S.K.;Kwon, Y.K.;Kim, H.M.;Lee, E.Y.;Kim, Y.C.;Park, H.J.;Kwon, W.S.;Park, G.S.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제11권2호
    • /
    • pp.33-36
    • /
    • 2009
  • A 1 MW class HTS (High-Temperature Superconducting) synchronous motor has been developed. This motor is aimed to be utilized for industrial application such as large motors operating in large plants. The HTS field coil of the developed motor is cooled by way of neon thermo siphonmechanism and the stator (armature) coil is cooled by water through hollow copper conductor. This paper also describes evaluation of some electrical parameters from performance test results of our motor, which was conducted at steady state in generator mode and motor mode. Open and short circuit tests were conducted in generator mode while a 1.1 MW rated induction machine was rotating the HTS machine. Electrical parameters such as mutual inductance and synchronous inductance are deduced from these tests. Load test was done upto rating torque during motor mode and efficiency was measured at each load torque.

Speed and Current Sensor Fault Detection and Isolation Based on Adaptive Observers for IM Drives

  • Yu, Yong;Wang, Ziyuan;Xu, Dianguo;Zhou, Tao;Xu, Rong
    • Journal of Power Electronics
    • /
    • 제14권5호
    • /
    • pp.967-979
    • /
    • 2014
  • This paper focuses on speed and current sensor fault detection and isolation (FDI) for induction motor (IM) drives. A new, accurate and high-efficiency FDI approach is proposed so that a system can continue operating with good performance even in the presence of speed sensor faults, current sensor faults or both. The proposed three paralleled adaptive observers are capable of current sensor fault detection and localization. By using observers, the rotor flux and rotor speed can be estimated which allows the system to run under the speed sensorless vector control mode when a speed sensor fault occurs. In order to detect speed sensor faults, a threshold-based scheme is proposed. To verify the feasibility and effectiveness of the proposed FDI strategy, experiments are carried out under different conditions based on a dSPACE DS1104 induction motor drive platform.

자기부상 열차용 부상 및 안내 결합형 횡자속 선형 전동기 설계에 관한 연구 (A Study on the Design of Transverse Flux Linear Motor in Combination with the Magnetic Levitation and Guidance)

  • 강도현;김문환
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권2호
    • /
    • pp.102-109
    • /
    • 2000
  • The magnetically levitated system technology is highly expected to contribute the new transportation system of the 21st century with its high velocity operation, better riding comforts, friendliness to environment and saving of maintenance labour. Its development has been completed in low speed and in high speed application. In 2005, the Transrapid with 430 km/h speed will go into operation between Berlin and Hamburg[1]. In the year 2000, the realization of JR-Maglev will be basically evaluated for commercial operation[2]. In korea, maglev test vehicle with magnet for levitation and single sided linear induction motor for propulsion is under test at 1 [km] test track in KIMM.[3,4] Here, a transverse flux linear motor in combination with the levitation and the guidance leads to a considerable high power density and high efficiency simultaneously. The designed and measured performance of transverse flux linear motor for maglev system revealed a great potential of system mass reduction.

  • PDF