• 제목/요약/키워드: High-Voltage Circuit Breaker

검색결과 136건 처리시간 0.035초

초고압차단기용 개폐제어기 개발(II) (Development of Controlled Switching Device for High Voltage Circuit Breakers II)

  • 김동현;김연풍;이현두;이수병;김영성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1041-1043
    • /
    • 2005
  • It is expected to reduce stresses to components of high voltage circuit breaker and transferred switching surge from power system by applying controlled switching technique to high voltage system. This technique has already been applied to switch shunt reactor or capacitor bank in advanced countries. In this paper, operating software is installed in developed controlled switching device and HMI(Human-machine Interface) is under developing, In the future, this technique is expected to contribute to S.A(Substation Automation).

  • PDF

반도체 스위칭 소자를 이용한 고속 고정밀의 전기화재 방재장치 (A Electrical Fire Disaster Prevention Device of High Speed and High Precision by using Semiconductor Switching Devices)

  • 곽동걸
    • 전력전자학회논문지
    • /
    • 제14권5호
    • /
    • pp.423-430
    • /
    • 2009
  • 최근 저압 배전계통에서 사용되고 있는 과부하겸용 누전차단기 즉, RCD의 저조한 응답특성으로 인한 전기화재 원인의 대부분을 차지하는 단락사고 및 과부하사고에 대한 대응이 매우 미흡한 실정이다. 이에 본 논문에서는 기존 RCD에 대한 모의 사고실험을 통하여 그 비신뢰성을 확인하고, 이러한 RCD의 단점을 개선하고자 내구성과 속응성이 우수한 반도체 스위칭 소자들과 고정밀 전류센서를 이용한 "전기화재 방재장치(EFDPD : Electrical Fire Disaster Prevention Device)"를 제안하여 저압 배전계통에서의 단락 및 과부하사고로 인한 전기재해를 방지하고자 한다. 제안한 장치의 고정밀 전류센서로 사용된 리드스위치는 각종 전기사고에서 수반되는 단락전류 및 과전류에 의한 배전선로의 상승된 자속을 정밀 감지한 후, 자체 차단장치를 동작시키는 원리를 가진다. 다양한 동작특성 분석을 통하여 기존의 차단기와 비교하여 차단동작 응답속도와 그 신뢰성이 입증된다. 이로써 제안한 전기안전 제어장치는 기존 RCD들의 빈번한 오동작과 비신뢰성, 저조한 응답특성으로 인한 각종 전기사고 및 전기화재의 발생을 방지하고자 한다.

임펄스전압에 대한 누전차단기의 부동작 특성 (Dead Operation Characteristics of Earth Leakage Circuit Breaker Caused by Impulse Voltages)

  • 이복희;장석훈;이승칠
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1715-1717
    • /
    • 1997
  • This paper deals with the dead operation characteristics of the earth leakage circuit breaker(ELB) caused by impulse voltages. The surge protective devices for electronic circuit and AC power lines are becoming more widely used. It is possible to give rise to the malfunction of ELB due to the operation of surge protective devices, and the interruption of AC power lines brings about several disadvantages such as low reliability of electronic and informational systems, economical loss, and etc. The dead operation characteristics of the ELB from impulse voltages were measured under the conditions of KS C 4613 and the test circuit with a varistor. As a result, the peak current value of the zero-phase sequence circuit of the ELB is increased as the surge voltage and stray capacitance increase. All of the ELBs used in this work were satisfied with the lightning impulse dead operation test condition defined in KS C 4613. However one specimen only did not cause dead operation in the condition of the test circuit with a varistor. There is high possibility that a large portion of the ELBs connected with the AC power lines having the surge protective devices bring about the dead operation.

  • PDF

특고압 가스 절연 부하 개폐기의 통합형 대전력 시험 방법 및 회로 구성에 관한 연구 (A Study on the Construction of Test circuit and Unification of Experiment Method for High Voltage Gas-insulated Load Switch using High Power Testing System)

  • 정흥수;김민영;김준석
    • 조명전기설비학회논문지
    • /
    • 제22권12호
    • /
    • pp.36-46
    • /
    • 2008
  • 본 논문은 대전력시험설비를 이용한 특고압 가스 절연 부하 개폐기의 대전력 시험회로의 구성과 통합형 시험 방법에 관하여 연구하였다. 대전력시험설비는 전기기기의 전기적 및 기계적인 성능을 검증하는 설비로서 단락발전기, 보호차단기, 투입스위치, 임피던스, 고압변압기, 저압변압기, 측정 및 보호시스템 등으로 구성되며, 이 시스템을 이용하여 단시간전류시험, 전류개폐용량시험, 단락투입 및 차단시험 등을 실시한다. 특고압 가스 절연 부하 개폐기의 규격으로는 국내 배전계통에 적용되는 ES(한국전력공사 표준규격) 5925-0002가 있으며, 국제 규격으로는 IEC 60265-1, 62271-1 및 IEEE C 37.74 등이 있다. 본 논문에서는 여러 규격에 각각 규정되어 있는 시험 절차, 시험회로 구성 및 시험 방법 등을 통합하여 600[MVA]급 대전력 시험설비에 적용하였다.

분할격자법을 이용한 초고압 가스차단기 유동해석 (The Application of Cartesian Cut Cell Method for a High-Voltage GCB)

  • 이종철;안희섭;김윤제
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.91-94
    • /
    • 2002
  • It is important to develop new effective technologies for increasing the interruption capacity and reducing the size of a GCB (Gas Circuit Breaker). It is not easy to test the real GCB model in practice as in theory. Therefore, a simulation tool based on a CFD (Computational Fluid Dynamics) algorithm has been developed to facilitate an optimization of the interrupter. But the choice of grid is not at all trivial in the complicated geometries like a GCB. In this paper, we have applied a CFD-CAD integration using Cartesian cut-cell method, which is one of the grid generation techniques for dealing with complex and multi-component geometries.

  • PDF

초전도 한류기 투입 위치에 따른 TRV 영향 분석 (Analysis of a TRV influence according to application position of a SFCL)

  • 방승현;이상봉;김철환;김재철;현옥배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.91-92
    • /
    • 2008
  • The rating of a circuit breaker depends not only on the interrupting current but also on a transient recovery voltage (TRV). To achieve a successful interruption, the circuit breaker must withstand the TRV. A superconducting fault current limiter (SFCL) is a device that limits the fault current fast and effectively without having high impedance during normal operation of the power system. Therefore, we studied the influence of the TRV according to the application of a resistive type SFCL in distribution system. This paper analyses the influence of the TRV for various application position of the resistive SFCL. The distribution system and the resistive SFCL were modeled by using EMTP-RV (Electromagnetic Transient Program - Restructured Version)

  • PDF

Experimental Investigations Into Low Current Steady State Arcs In A Dual-Airflow Model Interrupter

  • Shin, Young-June;Cho, Yun-Ok;Kim, Jin-Gi;Lee, Jeong-Rim
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.961-965
    • /
    • 1992
  • It is well-known that shock waves frequently occur inside the nozzle of the interrupter, and that they play important roles in the arc interruption. A model interrupter with two-dimensional dual-airflow nozzles was used for this experiment. The arc was ignited with 1.4 mil copper wire stretched between the electrodes which were spaced out 56 mm. The arc current of 60 to 230 A was achieved by adjusting the external resistance from 5.5 to 1.6 ohms. The arc tests have been conducted for investigating the air arc characteristics, and the effects of shock waves and nozzle pressure ratios on the arc voltage, the arc resistance, the arc power, and average electric field. The results of these tests have been analyzed to provide insights into the arc characteristics for gas circuit breakers. The average electric field is represented by the function of the arc current to show the negative E-I characteristic explicitly. The effects of shock waves and nozzle pressure ratios are shown to be significant for a circuit breaker performance.

  • PDF

초고압 차단부 아크방전 수치해석 및 난류모델에 관한 연구 (STUDY ON NUMERICAL ANALYSIS AND TURBULENCE MODELS FOR ARC DISCHARGES IN HIGH-VOLTAGE INTERRUPTERS)

  • 이종철
    • 한국전산유체공학회지
    • /
    • 제15권3호
    • /
    • pp.9-15
    • /
    • 2010
  • In this study, we calculated arc discharges and flow characteristics driven by arcs in a thermal puffer chamber, which is one of most outstanding high-voltage interrupters, for understanding the complex physics and the probability of thermal breakdown. The four main parts of arc model for this virtual-reality are radiation, PTFE ablation, Cu evaporation, and turbulence. Among these important parts the turbulence model can be critical to the reliability of computation results during the whole arcing history because the plasma flow is affected by high heat energy and mass momentum. Two turbulence models, the Prandtl's mixing length model and the standard $k-\varepsilon$ model, are applied for these calculations and are compared with pressure-rise inside chamber and arc voltage between the contacts as well as flow characteristics near current zero.

저압 배전선로의 누전 및 배선용 차단기의 오동작 방지를 위한 전기안전 제어장치 개발 (Development of electric safety control system for incapable operation of ELB and MCB using the low voltage distribution line)

  • 곽동걸;신미영;정도영;김효진;백성현;최병섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.371-372
    • /
    • 2007
  • The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The occurrence factor of the fire is electric arc or spark accompanied with electrical faults. Residual Current Protective Device (RCD), that is Earth Leakage Circuit Breaker(ELB) and Molded_case Circuit Breaker (MCB), of high sensitivity type used at low voltage wiring cuts off earth leakage and overload, but the RCD can't cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied low voltage distribution panel are prescribed to rated breaking time about 30[ms] (KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To be improved on such problem, this research development is proposed to a auxiliary control apparatus for RCD trip on electric arc or spark due to electrical fire. Some experimental results of the proposed apparatus is confirmed to the validity of the analytical results.

  • PDF

36kV급 진공차단기에 적용 가능한 PMA(영구자석형 조작기) 연구 및 동작특성 해석 (Research and Analysis of Dynamic Behavior Permanent Magnetic Actuator applicable to 38kV Vacuum Circuit Breaker)

  • 강종호;신동규;배채윤;정현교
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.18-20
    • /
    • 2004
  • This paper formulates the principle of the permanent magnetic actuator (PMA) and its dynamic characteristic calculation applicable to High Voltage Vacuum Interrupter (38kV/31.5kA). The new type of PMA is need to apply to High Voltage Vacuum Interrupter for large stroke length and contact force at interrupter. Consequently this paper describes the ideal matching of the new type of PMA mechanism with the characteristics required to operate successfully, reliably and efficiently a High Voltage Vacuum Interrupter.

  • PDF