• Title/Summary/Keyword: High-Temperature Air Combustion

Search Result 330, Processing Time 0.029 seconds

A Study of Flams Structure and Combustion Characteristics in a Premixed Flame Stabilized by a Stramlined Step(I) (유선형스텝에 의해 안정화된 예혼합 화염의 구조와 연소특성에 관한 연구(I))

  • 이재득;최병륜
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.12 no.3
    • /
    • pp.63-70
    • /
    • 1990
  • In a premixed flame stabilized by a streamlined step, the flame structure and combustion characteristics were investigated to identify the effect of the pressure pulsation in a combustion air. A flame stabilizing limits, visualization, mean temperature, ion current and gas concentration (O$_{2}$, CO$_{2}$, CO, UHC) were measured. With the combustion air of higher pressure pulsation, the development of the mixing layer was fast and wide, the temperature and combustion intensity were higher at arbitrary section. But, the effect was notably decreased with X=150 mm downstream. And a first eddy formation from step edge was earlier. Thus, with the combustion air of higher pressure pulsation, high rate of heat generation was expected.

  • PDF

Effect of Oxygen Enriched Air on the Combustion of a Turbulent Diffusion Flat Flame (산소부화공기가 난류 확산 평면화염의 연소에 미치는 영향)

  • Kwark, Ji-Hyun;Jeon, Chung-Hwan;Chang, Young-June
    • Journal of the Korean Society of Combustion
    • /
    • v.8 no.3
    • /
    • pp.1-7
    • /
    • 2003
  • Combustion using oxygen enriched air is an energy saving technology that can increase thermal efficiency by the improvement of burning rate and by the high temperature flame. Flame figures, OH radical intensities, temperature distributions and emission concentrations were measured according to oxygen enriched concentration and swirl number in a turbulent diffusion flat flame. It appeared that flame figure became flat and NO concentration decreased with increase of swirl number, and that the flame temperature increased high with increase of oxygen enriched concentration. In particular, it was most significant between oxygen concentration $40{\sim}60%$.

  • PDF

NOx Reduction with Secondary Air and Fuel in a Catalytic Combustor (촉매연소기에서 2단 공급공기와 연료가 NOx 저감에 미치는 연구)

  • 정진도;이보영
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.5
    • /
    • pp.541-549
    • /
    • 2003
  • A basic experimental study was conducted in order to find the optimum combustion control technology to decrease the thermal NO$_{x}$, by applying the catalytic combustion method with natural gas. NO$_{x}$ emission increased with increasing space velocity due to temperature rising in the furnace. In order to overcome the low resistance to high temperature, secondary air was supplied to the CST combustor. The following secondary fuel formed combustible mixture in part, which resulted in steep increase of the exiting temperature of the 2nd catalyst bed. It led to the more generator of NO$_{x}$, 30∼60% of the 1 st catalyst bed. It might be due to the potential increase of thermal NO$_{x}$.

Estimation method of heat flux at tube bank exposed to high temperature flue gas in large scale coal fired boilers (보일러 내부 고온가스에 노출된 전열 튜브에서의 열유속 평가 방법)

  • Jung, Jae-Jin;Song, Jung-Il
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.259-264
    • /
    • 2009
  • Most of the fossil power plants firing lower grade coals are challenged with maintaining good combustion conditions while maximizing generation and minimizing emissions. In many cases significant derate, availability losses and increase in unburned carbon levels can be attributed to poor combustion conditions as a result of poorly controlled local fuel and air distribution within the boiler furnace. The poor combustion conditions are directly related to the gas flow deviation in upper furnace and convection tube-bank but a less reported issue related to in large-scale oppose wall fired boilers. In order to develop a on-line combustion monitoring system and suggest an alternative heat flux estimation method at tube bank, which is very useful information for boiler design tool and blower optimizing system, field test was conducted at operating power boiler. During the field test the exhaust gases' temperature and tube metal temperature were monitored by using a spatially distributed sensors grid which located in the boiler's high temperature vestibule region. At these locations. the flue gas flow is still significantly stratified, and air in-leakage is minimal which enables tracing of poor combustion zones to specific burners and over-fire air ports. Test results showed that the flue gas monitoring method is more proper than metal temperature distribution monitoring for real time combustion monitoring because tube metal temp. distribution monitoring method is related to so many variables such as flue gas, internal flow unbalance, spray etc., Heat flux estimation at the tube bank with flue gas temp. and metal temp. data can be alternative method when tube drilling type sensor can't able to use.

  • PDF

Study on Co-incineration of Municipal Solid Waste and Organic Sludges (도시쓰레기와 유기성 하수 슬러지 혼합소각에 관한 연구)

  • Jurng, Jong-Soo;Chin, Sung-Min
    • 한국연소학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.238-244
    • /
    • 2005
  • This study performs the pilot-plant experiments to evaluate the effect of the oxygen enrichment on the co-incineration of municipal solid waste and organic sludge from a wastewater treatment facility. The design capacity of the stoker-type incinerator pilot-plant is 150 kg/h. Combustion chamber temperatures were measured as well as the stack gas concentrations, i.e., NOx, CO, and the residual oxygen. The maximum ratio of organic sludge waste to the total waste input is 30%. Also the oxygen-enriched air with 23% of oxygen in supplied air is used for stable combustion. As the co-incineration ratio of the sludge increased up to 30% of the total waste input, the primary and the secondary combustion chamber temperature was decreased $to900^{\circ}C$ (primary combustion chamber), $750^{\circ}C$(secondary combustion chamber), respectively, approximately $200^{\circ}C$ below the incineration temperature of the domestic waste only (primary: $1,100^{\circ}C$, secondary: $950^{\circ}C$). However, if the supplied air was enriched to 22% oxygen content in air, the incinerator temperature was high enough to burn the waste mixture with 30% sludge, which has the heating value of 1,600 kcal/kg.

  • PDF

Formation of MILD Combustion using Co-flow MILD Combustor (동축류 마일드 연소기를 적용한 마일드 연소 형성 연구)

  • Lee, Pil Hyong;Hwang, Sang Soon
    • Journal of the Korean Society of Combustion
    • /
    • v.22 no.3
    • /
    • pp.8-16
    • /
    • 2017
  • MILD combustion was first developed to suppress thermal NOx formation in combustor for heating industrial furnaces. In this paper, the effect of co-flow MILD combustor geometry and operating conditions on the formation of MILD combustion was analyzed using 3 dimensional numerical simulation. The numerical simulations were carried out using ANSYS Fluent. The combustion and turbulence flow was modeled using the Eddy Dissipation Concept(EDC) model and realizable $k-{\varepsilon}$ model respectively. The results show that the high temperature region and average temperature decreased due to an increase in the air velocity and decrease the wall thickness of fuel nozzle. In particular, the MILD combustion flame was found to be stable with a combustion flame region at fuel velocity 10 m/s, air velocity 20 m/s, fuel nozzle thickness 1.0 mm, equivalence ratio 0.9, and outlet area ratio 40%.

NOx Emissions in Flameless Combustion of Kerosene-Air Mixture Jets Injected into Hot Burned Gas Stream from Combustion Wall

  • Aida, Naoki;Hayashi, Shigeru;Yamada, Hideshi;Kawakami, Tadashige
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.449-452
    • /
    • 2004
  • “Flameless combustion” of lean to ultra lean mixtures, supported by high-temperature burned gas, can resolve the dilemma between complete combustion versus ultra-low NOx emissions in gas turbine combustors. The characteristics of NOx emissions and combustion in “lean-lean” two-stage combustion were investigated for fuel vapor and droplets / air mixture jets injected from the main injection tube that was placed perpendicular to the combustor wall into the primary hot burned gas prepared by combustion of lean mixtures on a perforated flame holder. The present results clearly show that the ultra-low NOx combustion supported by the reaction of lean mixtures well mixed with the hot burned gas from the primary stage is much more advantageous in achieving ultra-low NOx emissions while maintaining high combustion efficiency.

  • PDF

Understanding and Application of MILD combustion (마일드연소의 이해와 응용)

  • Kim, Nam Il
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.281-282
    • /
    • 2014
  • Recently, studies on Mild combustion have grown in many combustion application fields in the international combustion society. Compared with international activities in this field, domestic study in Korea has not been activated yet. This brief review aims to explain some essences of fundamental physics of Mild combustion and to introduce some recent application techniques of them. Fundamental physics of Mild combustion has been usually broken down into three aspects [1]; physical, thermodynamic, and chemical aspects. A major portion of Mild combustion physics is related to HiTAC (High Temperature Air Combustion) or HiCOT (High Temperature Combustion Technology). Although definition of Mild combustion is easily accepted among combustion engineers, combustion control in Mild combustion may be difficult without understanding essential physics of it. To encourage the research in this field, some representative cases will be introduced, and related essential techniques will be explained.

  • PDF

Environmentally Friendly Industrial Combustion Technologies (환경친화적 산업용 신연소기술)

  • Noh Dongsoon
    • Journal of the Korean Society of Visualization
    • /
    • v.2 no.1
    • /
    • pp.3-7
    • /
    • 2004
  • Two novel industrial combustion technologies are introduced. High temperature air regenerative combustion for industrial heating system and oxyfuel combustion for power plant are considered as a energy saving and $CO_{2}$ emission reducing combustion technology. Research works are necessary to understand fundamental phenomena and to develope application technologies to industrial sector.

  • PDF