• 제목/요약/키워드: High-Strength Reinforcement

검색결과 845건 처리시간 0.028초

Out of plane behavior of walls, using rigid block concepts

  • Gh.M, Mohammadi;F, Yasrebi
    • Structural Engineering and Mechanics
    • /
    • 제34권3호
    • /
    • pp.335-350
    • /
    • 2010
  • Out of plane behaviors of walls and infills are investigated in this paper, using rigid block concepts. Walls and infills are sometimes separated from top beams because of in plane movement of the walls and crumbling mortar layers under the top beams. Therefore, sufficient strength should be supplied to hold them against out of plane forces. Such walls are studied here under some real and scaled earthquakes, regarding their out of plane behavior. Influences of some reinforcements, connecting the walls to frames or perpendicular walls, are also studied. It is shown that unreinforced walls of regular sizes (3 m high and 4.5 m long) are normally unstable in the earthquakes. However, performing some reinforced bars that connect them to adjacent elements- frames or perpendicular walls - stabilizes them. Eventually, it is concluded that supplying 3 reinforced bars at 1/4, 2/4 and 3/4 of the panel's height stabilizes the walls in the assumed earthquakes. In this regard, for 20 cm and 35 cm thick walls ${\Phi}$18mm and ${\Phi}$20mm bars are to be used, respectively. For walls with other configurations, the forces and required areas of the reinforcements can be determined by the developed method of this paper.

Shear-strengthening of RC continuous T-beams with spliced CFRP U-strips around bars against flange top

  • Zhou, Chaoyang;Ren, Da;Cheng, Xiaonian
    • Structural Engineering and Mechanics
    • /
    • 제64권1호
    • /
    • pp.135-143
    • /
    • 2017
  • To upgrade shear performance of reinforced concrete (RC) beams, and particularly of the segments under negative moment within continuous T-section beams, a series of original schemes has been proposed using carbon fibre-reinforced polymer (CFRP) U-shaped strips for shear-strengthening. The current work focuses on one of them, in which CFRP U-strips are wound around steel bars against the top of the flange of a T-beam and then spliced on its bottom face in addition to being bonded onto its sides. The test results showed that the proposed scheme successfully provided reliable anchorage for U-strips and prevented premature onset of shear failure due to FRP debonding. The governing shear mode of failure changed from peeling of CFRP to its fracture or crushing of concrete. The strengthened specimens displayed an average increase of about 60% in shear capacity over the unstrengthened control one. The specimen with a relatively high ratio and uniform distribution of CFRP reinforcement had a maximum increase of nearly 75% in strength as well as significantly improved ductility. The formulas by various codes or guidelines exhibited different accuracy in estimating FRP contribution to shear resistance of the segments that are subjected to negative moment and strengthened with well-anchored FRP U-strips within continuous T-beams. Further investigation is necessary to find a suitable approach to predicting load-carrying capacity of continuous beams shear strengthened in this way.

용접구조물 요접토우부의 잔류응력이 피로강도에 미치는 영향 평가 (Evaluation of Influence on the Fatigue Strength of Residual Stresses at the Welded Toe of Welded Structure.)

  • 차용훈;김하식;김일수;성백섭
    • 한국공작기계학회논문집
    • /
    • 제10권4호
    • /
    • pp.7-13
    • /
    • 2001
  • This Study is to investigate the influence of weld residual stresses on the fatigue crack growth behaviors in pressure ves-sel reinforcement. In order to perform this study, the automatically welded specimens are prepared. The material is ASTM A516 grade 60 steel used in pressure vessel mainly. For pad-on-plate of skip welding continuous welding and PWHT specimen, fatigue crack initiation is generally initiat-ed at weld starting and end toe zone, and ruptured at weld starting toe zone, Fatigue life if pad-on-plate continuous speci-men is increased more than that of pad-on-plate skip fillet welding specimene about 85% under low load, about 20% under high load, and decreased than that of two-pad continuous welding specimen about 85%. In da/dN-$\Delta$ Κ curve under low load, pad-on-plate skip fillet welding specimen showed retardation on the initial crack, and the fatigue crack growth rate at the low region of $\Delta$Κ greater specimene E(3.8{\times}10^{-6}$mm/cycle). And the fatigue life of welding specimen was smaller than that of PWHT specimen.

  • PDF

반복하중을 받는 대각보강 콘크리트 연결보의 이력거동 예측을 위한 매개변수 결정방법 (Calibration of Parameters for Predicting Hysteretic Behavior of Diagonally Reinforced Concrete Coupling Beams)

  • 고혜영;한상환;허창대;이창석
    • 한국지진공학회논문집
    • /
    • 제21권6호
    • /
    • pp.303-310
    • /
    • 2017
  • The coupled shear wall system with coupling beams is an efficient structural system for high-rise buildings because it can provide excellent ductility and energy dissipation to the buildings. The objective of this study is to simulate the hysteretic behavior of diagonally reinforced concrete coupling beams including pinching and cyclic deteriorations in strength and stiffness using a numerical model. For this purpose, coupling beams are modeled with an elastic beam element and plastic spring element placed at the beam ends. Parameters for the analytical model was calibrated based on the test results of 6 specimens for diagonally reinforced concrete coupling beams. The analytical model with calibrated model parameters is verified by comparing the hysteretic curves obtained from analysis and experimental tests.

Predicting the moment capacity of RC slabs with insulation materials exposed to fire by ANN

  • Erdem, Hakan
    • Structural Engineering and Mechanics
    • /
    • 제64권3호
    • /
    • pp.339-346
    • /
    • 2017
  • Slabs prevent harmful effects of fire that may occur in any floor. However, it is necessary to protect the slabs from fire. Insulation materials may be appropriate to protect reinforced concrete (RC) slab from elevated temperature. In the present study, a model has been developed in artificial neural network (ANN) to predict the moment capacity ($M_r$) of RC slabs exposed to fire with insulation material. 672 data were obtained for ANN model through author's prepared program. Input layer in model consisted of seven input parameters; such as effective depth (d), ratio of d'/d, thermal conductivity coefficient ($k_{insulation}$), insulation materials thickness ($L_{insulation}$), reinforcement area ($A_{st}$), fire exposure time ($t_{\exp}$), and concrete compressive strength ($f_c$). The predicted $M_r$ by ANN was consistent with the obtained $M_r$ by author. It is proposed to ease computational complexity in determining $M_r$ using ANN. The effects of using insulation material on the moment capacity in RC slabs were also investigated. Insulating material with low thermal conductivity has been found to be more effective for durability to high temperature.

모래자갈과 암반의 복합지층에 시공한 저심도 터널의 사례연구 (Case Study of a Shallow Tunnelling Through Complex Strata of Sand-Gravel and Rock Mass)

  • 김치환
    • 터널과지하공간
    • /
    • 제25권3호
    • /
    • pp.244-254
    • /
    • 2015
  • 모래와 자갈이 암반 위에 퇴적된 지층에서 터널의 윗부분이 지하수가 많은 모래자갈층을 통과하는 상황에서 터널을 시공하였다. 지상의 일부 곡선구간에 빌딩들도 있는 저심도 터널을 안전하게 시공하기 위하여 강도가 작고 지하수가 많은 터널천정부의 모래자갈이 터널 내로 낙하하는 유사현상(sand flow)을 예방해야 하였다. 이를 위하여 대구경강관다단그라우팅이나 제트그라우팅으로 터널주변 충적층을 굴착 전에 미리 보강한 후 터널을 시공하였다. 이와 같이 터널을 보강한 효과와 지상빌딩의 안전을 시공 중 계측을 통하여 확인하였다.

Fabrication, Microstructures and High-Strain-Rate Properties of TiC-Reinforced Titanium Matrix Composites

  • 신현호;박홍래;장순남
    • 소성∙가공
    • /
    • 제8권3호
    • /
    • pp.259-259
    • /
    • 1999
  • TiC ceramic particulate-reinforced titanium matrix composites were fabricated and the resultant densification, microstructure, and static and dynamic mechanical properties were studied. Comparing Ti with TiH₂powders as host materials for TiC ceramic reinforcement by pressureless vacuum sintering, TiH₂-started composites showed better sinterability and resistance to both elastic and plastic deformation than Ti-started ones. When TiH₂and TiH₂-45 vol.%TiC samples were hot pressed, TiH₂matrices transformed to alpha prime Ti and alpha Ti phase, respectively. It is interpreted that the diffusion of an alpha stabilizer carbon from TiC into the matrix is one of the plausible reasons far such a microstructural difference. The 0.2% offset yield strengths of the hot pressed TiH₂and TiH₂-45 vol.%TiC samples were 1008 and 1446 MPa, respectively, in a static compressive mode (strain rate of 1×$10^{-3}$/s). Dynamic compressive strengths of the samples were 1600 and 2060 MPa, respectively, at a strain rate of 4×10³/s.

포스트텐션된 3연속 스팬 슬래브의 실험연구 (Experimental Study on Post-tensioned 3-Continuous Span Slabs)

  • 임재형;문정호;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표대회 논문집(III)
    • /
    • pp.668-673
    • /
    • 1998
  • The specimen of current study has the same type with the 3-span slabs of Burns et al used in the study by Mojtahedi/Gamble, which laid a ground for the revision of the ACI318-77 code to the ACI 318-83 code. But those specimens was failed prematurely before it reached the ultimate strength which the specimen had. The reason is that bonded reinforcements were cut off where there is no need for the flexural reinforcement. As results. the slabs failed ultimately where the reinforcements was cut off. Thus, the tendon stresses of failure may have been much smaller than the values which culd reach if the bonded reinforcements were extended beyond the theoretical cut off points. On the based on the fact mentioned above. the specimens which had the same conditions as the specimens of Burns et al were used in the current study, but in which the reinforcements were distributed in a sequence for the reinforcements not to be cut anywhere in the 3-span. As a results, it was known that the current ACI code, revised by the result of Mojtahedi/Gamble's study, overestimated the effect of span/depth ratio on the members with high span/depth ratio. Thus it was concluded that the effect of span/depth ratio on the ultimate stress of unbonded tendon regulated by the current ACI code must be reconsidered and reevaluated.

  • PDF

Experimental Cyclic Behavior of Precast Hybrid Beam-Column Connections with Welded Components

  • Girgin, Sadik Can;Misir, Ibrahim Serkan;Kahraman, Serap
    • International Journal of Concrete Structures and Materials
    • /
    • 제11권2호
    • /
    • pp.229-245
    • /
    • 2017
  • Post-earthquake observations revealed that seismic performance of beam-column connections in precast concrete structures affect the overall response extensively. Seismic design of precast reinforced concrete structures requires improved beam-column connections to transfer reversed load effects between structural elements. In Turkey, hybrid beam-column connections with welded components have been applied extensively in precast concrete industry for decades. Beam bottom longitudinal rebars are welded to beam end plates while top longitudinal rebars are placed to designated gaps in joint panels before casting of topping concrete in this type of connections. The paper presents the major findings of an experimental test programme including one monolithic and five precast hybrid half scale specimens representing interior beam-column connections of a moment frame of high ductility level. The required welding area between beam bottom longitudinal rebars and beam-end plates were calculated based on welding coefficients considered as a test parameter. It is observed that the maximum strain developed in the beam bottom flexural reinforcement plays an important role in the overall behavior of the connections. Two additional specimens which include unbonded lengths on the longitudinal rebars to reduce that strain demands were also tested. Strength, stiffness and energy dissipation characteristics of test specimens were investigated with respect to test variables. Seismic performances of test specimens were evaluated by obtaining damage indices.

항공기용 연료호스의 빔 시일 피팅의 형상변화에 따른 접촉특성에 관한 연구 (A Study on Contact Characteristics by the Geometry Variation of Beam Seal Fitting of an Aircraft Fuel Hose)

  • 전준영;김병탁
    • 한국기계가공학회지
    • /
    • 제12권6호
    • /
    • pp.101-108
    • /
    • 2013
  • An aircraft fuel hose is a kind of high pressure hose, and generally consists of a nipple, a socket, an inner tube, and a reinforcement layer to increase the tensile strength. Especially the nipple supports the other components in manufacturing stages such as the swaging or crimping processes however, the nipple also serves to prevent leakage in cases of hose engagement with a hydraulic system. To ensure the seal of the hose assembly, a beam seal fitting with metal-to-metal contact is usually adopted at the end of a nipple. Therefore, the geometry of the beam is an important parameter to be determined to make sure there is sufficient contact force. This study aims to investigate the effects of beam seal geometry on the contact force by changing the inclined angle and the thickness of the beam. The results reveal that the proper thickness and inclined angle of the beam seal are 0.45 mm and $8.5^{\circ}$, respectively.