• Title/Summary/Keyword: High-Rise Building

Search Result 1,762, Processing Time 0.03 seconds

Extraction and Analysis of Construction Phase Risk Factors in High-rise Construction Project (초고층 건설공사 시공단계 리스크 요인 도출 및 분석)

  • Kim, Sooyong;Kim, Sunghyun;Yang, Jinkook
    • Korean Journal of Construction Engineering and Management
    • /
    • v.17 no.2
    • /
    • pp.90-98
    • /
    • 2016
  • High-rise buildings construction project have various risk factors. Major risk factors are negative results such as time delay and increase of costs. Therefore, this study was analyzed risk factors in construction stages of high-rise buildings using by PROMETHEE technique. For this, this research were identified risk factors through experts Focus Group Interview(FGI). And, PROMETHEE was used to setup evaluation standard for analysis of high-rise building construction risks. Next, the standard of evaluation index calculation was composed by using the definition level in PDRI. Preference function and evaluation index were identified through questionnaires. Through these processes, this study has calculated the importance of high-rise building construction risks using by PROMETHEE technique. As a result, high degree risk factors were as following. These are 'Operation plan of material lifting', 'Outrigger & Belt Truss Construction', 'Foundation work plan of high-rise building' and 'Considering a Structure concept of high-rise building'.

A Sutdy on the Pressure Distribution Characteristic of High-rise Buildings in Fire Using Computer Simulation (시뮬레이션을 이용한 화재 시 고층건축물의 압력분포 특성에 관한 연구)

  • Kim, Hye-Won;Lee, Byeong-Heun;Jin, Seung-Hyeon;Kwon, Young Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.49-50
    • /
    • 2019
  • In the case of High-rise buildings, it has a problem by stack effect that rise of vertical height. Especially in case of fire, it need to the consideration of stack effect that it has bigger than general. Therefore in this study, we used to the Contamw and FDS simulation for analysis of stack effect and pressure distribution characteristic in fire. As a result the Contamw simulation shows the pressure distribution by stack effect in general high-rise buildings. However, in case of fire, the height of the neutral plane is lowered and stack effect is larger. Therefore, it is necessary to multiply analyze the temperature distribution and the stack effect in fire.

  • PDF

Prediction of Torsional Behavior for High-Rise Building Structures under Lateral Load (횡하중에 의한 고층건물의 비틀림 거동분석)

  • 서현주
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.04a
    • /
    • pp.151-160
    • /
    • 1999
  • It is recommended to have symmetric plan and elevation in structural design of hight-rise building structures to reduce torsional response of the structures. However it is not always allowed to do so due to architectural purposes. in many cases high-rise buildings are asymmetric. The purpose of this study is to predict the torsional behavior of high-rise building structures with asymmetric plan. Equivalent lateral stiffness and deformation shape factor are used for prediction of torsional response of high-rise buildings. Overall torsion of a structure is estimated by equivalent lateral stiffness and torsion of each floor is estimated by deformation factor in each 2-D lateral force resisting elements.

  • PDF

Health Monitoring of High-rise Building with Fiber Optic Sensor (SOFO)

  • Mikami, Takao;Nishizawa, Takao
    • International Journal of High-Rise Buildings
    • /
    • v.4 no.1
    • /
    • pp.27-37
    • /
    • 2015
  • Structural health monitoring is becoming more and more important in the domain of civil engineering as a proper mean to increase and maintain the safety, especially in the land of earthquakes like Japan. In many civil structures, the deformations are the most relevant parameter to be monitored. In this context, a monitoring technology based on the use of long-gage fiber optic deformation sensor, SOFO is being applied to a 33-floors tall building in Tokyo. Sensors were installed on the $2^{nd}$ floor's steel columns of the building on May 2005 in the early stage of the construction. The installed SOFO sensors were dynamic compatible ones which enable both static and dynamic measurements. The monitoring is to be performed during the whole lifespan of the building. During the construction, static deformations of the columns had been measured on a regular basis using a reading unit for static measurement and dynamic deformation measurements were occasionally conducted using a reading unit for dynamic measurement. The building was completed on August 2006. After the completion, static and dynamic deformation measurements have been continuing. This paper describes a health monitoring technology, SOFO system which is applicable to high-rise buildings and monitoring results of a 33-floors tall building in Tokyo from May 2005 to October 2010.

TORANOMON HILLS - Super High-Rise Building on Urban Highway -

  • Hitomi, Yasuyoshi;Takahashi, Hiroshi;Karasaki, Hidenori
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.3
    • /
    • pp.167-171
    • /
    • 2014
  • TORANOMON HILLS is the main building of a large-scale re-development project located in the center of Tokyo. This high-rise building has a height of 247 m and 52 floors above ground, 5 floors below ground, and $62m{\times}80m$ in plan. It is used as hotel, residential facilities, offices, shops and conference facilities. The super structure is mainly a rigid steel frame with response-control devices, using concrete-filled steel tube columns. The underground section is a mixed structure composed of steel, steel-reinforced concrete and reinforced concrete framings. The piled-raft foundation type is used. The remarkable feature of this high-rise building is that the motorway runs through the basements of the building, which makes it stand just above the motorway. This condition is an important factor of the building design. The plan shape is designed to fit along the curve of the motorway. Special columns at the corners are required to avoid placing columns in the motorway. This special column is a single inclined column in the lower floors that branches into two columns in the mid-floors to suit the column location in the upper floors. The cast steel joint is used for the branching point of each special column to securely transfer the stress.

E/V Shaft Cooling Method as a Stack Effect Countermeasure in Tall Buildings

  • Lee, Joonghoon;Song, Doosam;Jeong, Eunyoung
    • International Journal of High-Rise Buildings
    • /
    • v.1 no.2
    • /
    • pp.99-105
    • /
    • 2012
  • The higher the building height and the larger the temperature difference between the outdoor and indoor space, the more remarkable is the draft driven by the stack effect in high-rise buildings. Moreover, the stack effect can bring about the deterioration of habitability and the degradation of the performance of the indoor control system in high-rise buildings. In this study, as a measure to attenuate the stack effect, the E/V shaft cooling method was proposed and its performance was compared with the conventional stack effect control method for strengthening the air-tightness of the building using a numerical simulation method. The total decreasing ratios on the stack effect in a building were compared, and the probabilities of the secondary problems were analyzed. The results show that the E/V shaft cooling is very effective to decrease the stack effect in a high-rise building in terms of the reduction performance and application. Moreover, this method does not cause secondary problems, such as stack pressure transition to other walls, unlike the conventional stack effect mitigation method.

Effects of vertical ribs protruding from facades on the wind loads of super high-rise buildings

  • Quan, Yong;Hou, Fangchao;Gu, Ming
    • Wind and Structures
    • /
    • v.24 no.2
    • /
    • pp.145-169
    • /
    • 2017
  • The auxiliary structures of a high-rise building, such as balconies, ribs, and grids, are usually much smaller than the whole building; therefore, it is difficult to simulate them on a scaled model during wind tunnel tests, and they are often ignored. However, they may have notable effects on the local or overall wind loads of the building. In the present study, a series of wind pressure wind tunnel tests and high-frequency force balance (HFFB) wind tunnel tests were conducted on rigid models of an actual super high-rise building with vertical ribs protruding from its facades. The effects of the depth and spacing of vertical ribs on the mean values, fluctuating values and the most unfavorable values of the local wind pressure coefficients were investigated by analyzing the distribution of wind pressure coefficients on the facades and the variations of the wind pressure coefficients at the cross section at 2/3 of the building height versus wind direction angle. In addition, the effects of the depth and spacing of vertical ribs on the mean values, fluctuating values and power spectra of the overall aerodynamic force coefficients were studied by analyzing the aerodynamic base moment coefficients. The results show that vertical ribs significantly decrease the most unfavorable suction coefficients in the corner recession regions and edge regions of facades and increase the mean and fluctuating along-wind overall aerodynamic forces.

Properties of High Strength Concrete before and after Pumping in Response to Strength Level and Pumping Height (초고층 건축물에서 고강도 콘크리트의 강도 및 압송높이 변화에 따른 펌프 압송 전·후의 물성평가)

  • Jung, Sang-Woon;Lee, Hong-Kyu;Jo, Man-Ki;Kim, Gyu-Dong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.274-275
    • /
    • 2014
  • As the increase amount of high rise building, equipments for high rise building have been extensively studied. However quality problems caused as the pumping of concrete including loss of flowalility, air content and increasing of the temperature. In this study, fundamental performances of the 80 MPa concrete before·after pumping has been tested. Results showed slump flow increased after pumping temperature of concrete also increased after pumping. Results also shown air content all satisfied the target range and compressive strength of concrete increased about 20 % after pumping, All the performances satisfied the standard for 80 MPa.

  • PDF

Multitasking Façade: How to Combine BIPV with Passive Solar Mitigation Strategies in a High-Rise Curtain Wall System

  • Betancur, Juan
    • International Journal of High-Rise Buildings
    • /
    • v.6 no.4
    • /
    • pp.307-313
    • /
    • 2017
  • This paper outlines the processes and strategies studied and selected by the team during the design stages of the project for the incorporation of BIPV into the tower's façade. The goal was to create a system that helps reduce internal heating and cooling loads while collecting energy through photovoltaic panels located throughout the building. The process used to develop this façade system can be broken down into three stages. 1. Concept: BIPV as design catalyst for a high-rise building. 2. Optimization: Balancing BIPV and Human comfort. 3. Integration: Incorporating BIPV into a custom curtain wall design. The FKI Project clearly illustrates the evolution building enclosures from simple wall systems to high performance integrated architectural and engineering design solutions. This design process and execution of this project represent the design philosophy of our firm.

A Study on Characteristics of Normal Strength Concrete adapted to Concrete Filled Steel Tube (콘크리트 충전강관구조(CFT) 적용을 위한 일반강도 콘크리트 물성에 관한 실험적 연구)

  • 강동현;강용학;정근호;이영도;이장오
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2001.11a
    • /
    • pp.46-51
    • /
    • 2001
  • As a rule, in case of CFT for high-rise building, high strength concrete is required since it should have high fluidity, segregation resistance and large proportion of cement per unit considering the fi11ing beneath the diaphragm. However, regarding the low-rise building under 20 stories, it is somewhat difficult to use high strength concrete. This is a fundamental study to develop a concrete with normal strength and high fluidity for CFT of low-rise building, whose purposes are in speculating several kinds of changes in concrete's characteristics through various experiments and offering basic documents for practicalization in si to and production through mock-up test.

  • PDF