• 제목/요약/키워드: High-Power-Factor

검색결과 1,902건 처리시간 0.154초

Zero Cross Detection Power Factor Correction IC 설계 (Design of Zero Cross Detection Power Factor Correction IC)

  • 서길수;김형우;김기현;박현일;김남균;박주성
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.519-520
    • /
    • 2008
  • In this paper, we design and implement the monolithic zero crossing detection power factor correction IC using a high voltage 30V BCD process. The ZCD PFC IC is designed for power applications, such as notebook, LCD monitor, etc. It includes power factor correction function and several protection circuit, regulator, high-voltage high current output drivers. And also, the designed IC has restart timer function which the output pulse is generated if the output signal of IC is not in a 200us. The simulation results show that the designed IC acts properly as power factor correction IC with efficient protective functions.

  • PDF

역률개선을 위해 경계전류모드로 동작하는 브리지리스 부스트 컨버터 (Boundary Current Mode Operated Bridgeless Boost Converter for Power Factor Correction)

  • 유병규;이성세;한상규;문건우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 추계학술대회 논문집
    • /
    • pp.90-94
    • /
    • 2003
  • Recently, many nations have released standard such as IEC 1000-3-2 and IEEE 519 which impose a limit on the harmonic current drawn by equipment connected to AC line in order to prevent the distortion of an AC line. Among the wide variety of active methods for improving power factor and harmonic distortion, the boost converter is very effective because it has a continuous line current , small choke filter and high power factor. In high power application, however, the bridge diode loss in the boost converter has made the efficiency lower and the temperature of the board higher. A new approach without bridge diode to make the same characteristics of the conventional boost converter has also been developed. This paper present the comparisons between the continuous current mode(CCM) operated conventional boost converter and the boundary current mode(BCM) operated the bridgeless boost converter for high efficiency and high power factor.

  • PDF

에너지재생 수동스너버를 갖는 고역율 부스트 정류기 (High-Power-Factor Boost Rectifier with a Passive Energy Recovery Snubber)

  • 김만고;백승호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.428-432
    • /
    • 1998
  • A passive energy recovery snubber for high-power-factor boost rectifier, in which the main switch is implemented with a MOSFET, is described in terms of the equivalent circuits that are operational during turn-on and turn-off sequences. The main switch combined with proposed snubber can be turned on with zero current and turned off at limited voltage stress. The high-power-factor boost rectifier with proposed snubber is implemented, and the experimental results are presented to confirm the validity of proposed snubber.

  • PDF

고역율 AC/AC 전류형 고주파 공진 인버터의 특성해석에 관한 연구 (A Study on Characteristic Analysis of AC to AC Current-Fed Type High Frequency Resonant Inverter with High Power Factor)

  • 김종해;원재선
    • 조명전기설비학회논문지
    • /
    • 제28권1호
    • /
    • pp.16-28
    • /
    • 2014
  • This paper presents a novel high-power-factor circuit topology of AC to AC current-fed type high frequency resonant inverter which includes the function of power factor correction(PFC) in the proposed inverter to operate the AC input block with high power factor. The proposed circuit topology of AC to AC current fed type high resonant inverter removes DC link electrolytic capacitor and has also the one of power factor correction(PFC) in the inverter circuit without an additional PFC circuit since the input current by constituting it in parallel as an unit inverter, which assumes the class-E high frequency resonant inverter of conventional current-fed type, flows in the form of the resultant current flowing through each constant current reactor($L_{d1}$, $L_{d2}$). The circuit analysis of proposed inverter is generally described by adopting the normalized parameters and the evaluation of its operating characteristics are conducted by using the parameters such as the ratio of switching and resonant frequency(${\mu}$), coupling coefficient(k) and so on. An example of procedure for circuit design based on the characteristic values obtained from the theoretical analysis is presented. To confirm the validity of the theoretical analysis, the experimental results are also presented. In the future, the proposed inverter shows it can be practically used as power supply system for induction heating application, DC-DC converter etc.

저가격 형광등용 전자식 안정기에 적합한 새로운 역률개선회로 (Novel High Power Factor Correction Circuit for Low-Cost Electronic Ballasts)

  • 채균;윤용식;조규형
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 F
    • /
    • pp.2072-2074
    • /
    • 1997
  • A new low-cost high power factor correction circuit for electronic ballasts is proposed. The proposed circuit provides good power factor correction, low current harmonic distortion and cost-effectiveness. The prototype meets the IEC555-2 requirements satisfactorily with nearly unity power factor.

  • PDF

구조물 및 기기의 내진성능 평가를 위한 고주파수 지진에 의한 원자력발전소의 지진응답 증폭계수 (Seismic Response Amplification Factors of Nuclear Power Plants for Seismic Performance Evaluation of Structures and Equipment due to High-frequency Earthquakes)

  • 임승현;최인길;전법규;곽신영
    • 한국지진공학회논문집
    • /
    • 제24권3호
    • /
    • pp.123-128
    • /
    • 2020
  • Analysis of the 2016 Gyeongju earthquake and the 2017 Pohang earthquake showed the characteristics of a typical high-frequency earthquake with many high-frequency components, short time strong motion duration, and large peak ground acceleration relative to the magnitude of the earthquake. Domestic nuclear power plants were designed and evaluated based on NRC's Regulatory Guide 1.60 design response spectrum, which had a great deal of energy in the low-frequency range. Therefore, nuclear power plants should carry out seismic verification and seismic performance evaluation of systems, structures, and components by reflecting the domestic characteristics of earthquakes. In this study, high-frequency amplification factors that can be used for seismic verification and seismic performance evaluation of nuclear power plant systems, structures, and equipment were analyzed. In order to analyze the high-frequency amplification factor, five sets of seismic time history were generated, which were matched with the uniform hazard response spectrum to reflect the characteristics of domestic earthquake motion. The nuclear power plant was subjected to seismic analysis for the construction of the Korean standard nuclear power plant, OPR1000, which is a reactor building, an auxiliary building assembly, a component cooling water heat exchanger building, and an essential service water building. Based on the results of the seismic analysis, a high-frequency amplification factor was derived upon the calculation of the floor response spectrum of the important locations of nuclear power plants. The high-frequency amplification factor can be effectively used for the seismic verification and seismic performance evaluation of electric equipment which are sensitive to high-frequency earthquakes.

새로운 고역률 승압형 AC-DC 컨버터의 입력전류 파형분석에 관한 연구 (A Study on Waveform Analysis of Input Current for Novel Boost AC-DC Converter of High Power Factor)

  • 곽동걸
    • 조명전기설비학회논문지
    • /
    • 제19권8호
    • /
    • pp.102-108
    • /
    • 2005
  • 본 논문에서는 소프트 스위칭에 의한 새로운 고역률 승압형 AC-DC 컨버터가 제안되고 입력전류의 파형 및 고조파분석에 대해 상세히 해석된다. 시비율 일정의 전류불연속 제어에 의해 동작되는 제안된 컨버터의 입력전류는 교류 입력전압의 크기에 비례한 불연속적인 펄스열의 정현파 형태로 되어 입력역률을 개선시킨다. 또한 제안된 컨버터는 소프트 스위칭을 위한 공진동작에 의해 무손실 스너버 커패시터의 입력측 에너지 유입에 따른 역률증대의 효과를 가지며, 기존의 고역률 승압형 AC-DC 컨버터와 비교되어 입력전류의 수학적 분석과 컴퓨터 시뮬레이션, 실험결과 등에 의해 그 우수성이 입증된다.

Feedforward제어 방식을 이용한 역률개선회로의 비교분석 (Comparative analysis of power factor correction circuit using Feedforward)

  • 김철진;장준영;유병규;이달은;백수현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.187-189
    • /
    • 2003
  • Conventional Switched Mode Power Supplies(SMPS) with diode-capacitor rectifier have distorted input current waveform with high harmonic content. Typically, these SMPS have a power factor lower than 0,65. To improve with this problem the power factor correction(PFC) circuit of power supplies has to be introduced. Specially. to the reduce size and manufacture cost of power conversion device, the single-stage PFC converter is increased to demand as necessary of study. in this paper, The comparative analysis of power factor correction circuit using Feedforward control with average current mode flyback converter(single-stage) and boost converter(two-stage). Also, the validity of designed and manufactured high power factor flyback converter and boost converter is confirmed by simulation and experimental results.

  • PDF

90-260Vrms 입력 범위를 갖는 단일 전력단 고역률 컨버터 (Single-Stage High Power Factor Converter for 90-260Vrms Input)

  • 김학원;문건우;조관열;윤명중
    • 전력전자학회논문지
    • /
    • 제7권1호
    • /
    • pp.18-29
    • /
    • 2002
  • 기존의 역률 개선 컨버터는 경 부하에서 높은 직류 링크 전압을 갖는다. 특히 라인 전압이 높고 부하가 작을 경우, 직류 링크 전압은 매우 높은 전압을 갖게 되어 실용상 문제가 존재한다. 본 논문에서 역률 개선 부로 벅 토폴로지를 갖는 새로운 단일 전력 단 역률 개선 컨버터를 제안하였다. 또한 제안된 컨버터의 타당성을 증명하기 위해 제안된 회로의 설계 예를 보였으며, 설계 시 고려되어야 할 사항들과 관련 설계 식을 유도하였다. 유도된 설계 식으로부터 정해진 회로 정수 값을 이용하여 실험을 실시하였고, IEC1000-3-2의 역률 규제를 만족함을 입증하였다. 본 논문에서 제안된 컨버터를 통하여 기존의 단일 전력 단 컨버터의 문제점인 경 부하 시 높은 직류 링크 전압 문제를 해결할 수 있었다.

높은 역률을 가지는 단순 구조 LED 구동 전력컨버터 (Simple Structure LED-Driving Power Converter with High Power Factor)

  • 정강률
    • 전기전자학회논문지
    • /
    • 제22권3호
    • /
    • pp.767-773
    • /
    • 2018
  • 본 논문에서는 높은 역률을 가지는 단순 구조 LED 구동 직류 전력컨버터를 제안한다. 제안한 전력컨버터는 PFC 부스트 컨버터와 전통적인 플라이백 컨버터를 오직 하나의 전력변환 회로로 병합함으로써 LED 구동 전력컨버터의 구조를 단순화한다. 그리하여 제안한 컨버터는 오직 하나의 PWM 제어기 IC를 이용하여 제어되고 높은 역률과 정출력 전압/전류 및 제작비용의 효율성을 달성한다. 따라서 제안한 컨버터는 LED 조명시스템의 산업 생산과 이용에 적합하다. 본 논문에서는 제안한 컨버터의 동작분석과 설계예시를 간단하게 설명한다. 또한 설계된 회로파라미터들에 근거하여 제작된 프로토타입의 실험결과를 통하여 제안한 컨버터의 동작특성을 입증한다.