• Title/Summary/Keyword: High-Performance Concrete

Search Result 2,182, Processing Time 0.028 seconds

Prediction Model on Autogenous Shrinkage of High Performance Concrete Used Material for Shrinkage Reduction (수축저감재료의 영향을 고려한 고성능 콘크리트의 자기수축 예측 모델)

  • Koh Kyoung-Taek;Kang Su-Tae;Yoo Sung-Won;Kim Do-Gyeong;Han Cheon-Goo;Lee Jang-Hwa
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.285-288
    • /
    • 2004
  • Generally, the autogenous shrinkage of high performance concrete is important in that it can lead the early cracks in concrete structures. In the previous study, The. autogenous shrinakge of HPC was found to decrease with incresing expansive additive and shrinakge reduction agent. In case of combined use, the autogenous shrinakge was more reduction than in case separate use. The purpose of this study is to derive a realistic equation to estimate the autogenous shrinakge model of high performance concrete with exapnsive agent and shrinakge reduction agent. investigated the durability of high performance concrete using expansive additive and shrinkage reducing agent. The proposed equation showed reasonably good correlation with test data on autogenous shrinakge of high performance concrete with material for shrinkage reduction.

  • PDF

Development of High-Performance Technology of Beam-Column Joints in Reinforced Concrete Building (철근콘크리트 건물의 보-기둥 접합부 고성능화 기술 개발에 관한 연구)

  • 하기주;신종학;조효식;주정준
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.553-556
    • /
    • 1999
  • In this dissertation, experimental research was carried out to study the hysteretic behavior of reinforced high-strength concrete beam-column joints designed by high performance techniques, such as application of high-strength concrete, reducing of joint regions damage, moving of beam plastic hinge. Specimens(HJAI, HJCI), designed by the development of earthquake-resistant performance, moving of beam plastic hinge, and new design approach, were attained the moving of beam plastic hinge and developed significantly earthquake-resistant performance of such joints.

  • PDF

Performance Analysis of Low-viscosity type Superplasticizer (저점도형 감수제의 성능 분석)

  • Han, Dongyeop
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.10a
    • /
    • pp.35-36
    • /
    • 2016
  • Recently, with the increasing demand of high performance of concrete, the mix design of concrete mixture has became low water-to-binder ratio with high binder content. To compensate these trend of mix design, high range water reducer, or superplascizier has been invented to achieve high flowable concrete. Although this superplasticizer provides favorable workability based on its dispersing action on the components of concrete mixture, it has an limitation of decreasing viscosity of the mixture, and thus it is difficult to secure sufficient workability for high performance concrete mixtures with high binder content. To improve the workability of concrete with high viscosity, recently, low-viscosity type superplasticizer was introduced, and in this research, a fundamental properties of low-viscosity type superplasticizer is evaluated.

  • PDF

Properties of Fire Resistance of Concrete with Contents of Polypropylene Fiber and Specimens Size (폴리프로필렌 섬유의 혼입률 및 부재크기 변화에 따른 콘크리트의 내화 특성)

  • 전선천;황인성;이병열;양성환;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.463-468
    • /
    • 2001
  • A lot of considerations on the spatting by fire of high performance concrete should be taken into for fire resistance of the concrete structures. In this paper, fire resistance of high performance concrete is described using polypropylene fiber, which is known to be contributed to fire resistance. Strength level and member size are varied with. According to test results, spatting by fire takes place more easily, as W/C increases and member size decreases. It shows that concrete containing polypropylene fiber has good effects on preventing spatting by fire. In case high performance concrete does not contain polypropylene fiber, residual strength shows to be decreased remarkably compared :o that of normal concrete. Whereas, in case 0.1% of polypropylene fiber contents, high performance concrete shows higher residual strength than that of normal concrete. As member size is smaller, residual strength shows to be decreased.

  • PDF

Effect of glass powder on the behaviour of high performance concrete at elevated temperatures

  • Kadik, Abdenour;Cherrak, Messaouda;Bali, Abderrahim;Boutchicha, Djilali;Hannawi, Kinda
    • Advances in concrete construction
    • /
    • v.10 no.5
    • /
    • pp.443-454
    • /
    • 2020
  • In recent years, many studies have been done on the performance of concrete containing glass powder (GP). For the purpose of widespread use of GP in concrete mixes, a knowledge of the performance of such a mixture after a fire is essential for the perspective of structural use. This research work was carried out to evaluate the performance of High Performance Concrete (HPC) made with GP after being exposed to elevated temperature. The studied mixtures include partial replacement of cement by GP with up to 30%. The mechanical performance and structural alterations were assessed after high temperature treatment from 200℃ to 800℃. The mechanical performance was evaluated by testing the specimens to the compressive and tensile strength. In addition, the mass loss and the porosity were measured to notice the structural alterations. Changes in microstructure due to temperature was also investigated by the X-ray diffraction (XRD) and thermal gravimetric analyses (TGA) as well as porosity adsorption tests. The results of the concrete strength tests showed a slight difference in compressive strength and the same tensile strength performance when replacing a part of the cement by GP. However, after high temperature exposition, concrete with GP showed better performance than the reference concrete for temperature below 600℃. But, after heating at 800℃, the strength of the concrete with GP drop slightly more than reference concrete. This is accompanied by an important increase in mass loss and water porosity. After the microstructure analysis, no important changes happened differently for concrete with GP at high temperature except a new calcium silica form appears after the 800℃ heating.

Evaluation of Optimum Thickness of High Performance Concrete Bridge Deck Pavement (고성능 콘크리트 교면포장의 최적 두께 평가)

  • Park, Hae-Geun;Kim, Ji-Won;Jeon, Sang-Eun;Lee, Myeong-Sub;Won, Jong-Phil
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.318-321
    • /
    • 2006
  • The objective of this study is to evaluate the optimum thickness of High Performance Concrete bridge deck pavement. The application of High Performance Concrete bridge deck pavement with micro-silica was introduced to north America in the early 1980's. In order to decide the optimum thickness of High Performance Concrete bridge deck pavement, we conducted Finite Element Method analysis with Incheon Grand Bridge constructed by SAMSUNG E&C. From the FEM results, a thickness of five centimeters of High Performance Concrete bridge deck pavement with micro-silica is considered as a resonable value compared with the conventional asphalt bridge deck pavement.

  • PDF

Mix Design of High Performance Concrete (고성능콘크리트의 배합설계)

  • Jung Yong-Wook;Lee Seung-Han;Yun Yong-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.73-76
    • /
    • 2005
  • This study aims to suggest a simple and convenient design for a mix proportion method for high performance concrete by determining the optimum fine aggregate ratio and minimum binder content based on the maximum density theory. The mix design method introduced in this study adopted the optimum fine aggregate ratio with a minimum void and binder content higher than the minimum binder content level. The research results reveal that the method helps to reduce trial and error in the mixing process and is a convenient way of producing high performance concrete with self filler ability. In an experiment based on the mix proportion method, when aggregate with the fine aggregation ratio of 41$\%$ was used, the minimum binder content of high performance concrete was 470kg/$m^{3}$ and maximum aggregate capacity was $0.657m^{3}/m^{3}$. In addition, in mixing high performance concrete, the optimal slump flow to meet filler ability was 65$\pm$5cm, V load flow speed ranged from 0.5 to 1.5.

  • PDF

A Characteristic of Autogenous shrinkage and Dry shrinkage for High Performance Concrete Using Type I and Type IV Cement (1종 및 4종시멘트를 이용한 고성능 콘크리트의 자기수축 및 건조수축 특성)

  • Lee Woong-Jong;Ryu Jae-Sang;Lee Jong-Ryul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.561-564
    • /
    • 2004
  • In this study, the properties of autogenous shrinkage and dry shrinkage for high performance concrete using Type I and Type IV cement were discussed. According to experimental results, autogenous shrinkage of SN30(the high performance concrete using type I cement) shows values higher than SL30( the high performance concrete using type IV cement). But the dry shrinkage of SN30 is almost the same as SL30. It is observed that the total shrinkage strain of SN30 is higher than that of SL30, because the ratio of autogenous shrinkage of the total shrinkage is relatively large. Therefore, SL30 is more effective to control or minimize the cracking of the high performance concrete, compared with SN30.

  • PDF

Analysis of physical properties of high-performance concrete using domestic low-cost silica fume (국산 저가형 실리카퓸을 이용한 고성능 콘크리트의 물리적 특성 분석)

  • Kim, Sang Do;Yun, Kyung Ku;Ham, Seung Yeon;Lee, Kyeo Re
    • Journal of Industrial Technology
    • /
    • v.37 no.1
    • /
    • pp.32-36
    • /
    • 2017
  • In this study, as part of a research on the development of economical high-performance concrete with high strength and high quality, the physical properties of high-performance concrete were analyzed by substituting a certain amount of low-cost domestic silica fume exempted from the re-importation type distribution structure of the domestic production and the existing high-priced silica fume distribution structure. Performing tests to identify the physical properties of the fresh and hardened concrete and durability analogy of the concrete which use low-cost domestic silica fume and imported silica fume, the chloride ion penetration resistance test result showed that the strength difference between the low-cost silica fume and the imported silica fume is not big but the strength of the low-cost silica fume was measured higher than the imported silica fume. The chloride ion penetration resistance of all variables was measured as "very low". Since the low-cost domestic silica fume can be used as a high-performance admixture of concrete, the results suggest that it is possible to produce a more economical high-performance concrete.

Durability Characteristics of High-Early-Strength Concrete (조기강도 콘크리트의 내구특성)

  • 원종필;김현호;안태송
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.991-996
    • /
    • 2001
  • The long-term durability characteristics of high-early-strength concrete were assessed. The effect of long-term durability characteristics of high-early-strength concrete were investigated. In experiment, two different types of fiber were adopted for improvement of durability. High-early-strength fiber reinforced concretes using regulated-set cements are compared with high-early-strength concrete without fiber. The durability performance of the laboratory-cured high-early-strength concrete specimens was determined by conducting an accelerated chloride permeability, abrasion resistance, freeze-thaw, surface deicer salt scaling and wet-dry repetition test. The results indicated that incorporation of fibers enhance durability performance.

  • PDF