• Title/Summary/Keyword: High-Dose

Search Result 4,246, Processing Time 0.033 seconds

Quantitative Evaluation of Image Quality using Automatic Exposure Control & Sensitivity in the Digital Chest Image (디지털 흉부영상에서 자동노출제어 및 감도변화를 이용한 영상품질의 정량적인 평가)

  • Lee, Jin-Soo;Ko, Seong-Jin;Kang, Se-Sik;Kim, Jung-Hoon;Kim, Dong-Hyun;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.8
    • /
    • pp.275-283
    • /
    • 2013
  • The patient radiation dose is different depending on selection of Ion chamber when taking Chest PA which using AEC. In this paper, we studied acquiring the best diagnostic images according to selection of Ion chamber on AEC mode as well as minimizing patient radiation dose. Experimental methods were selection of Ion chamber and change of sensitivity under the same conditions as Chest PA projection. At AEC mode, two upper ion chambers sensors and one lower ion chamber sensor were divided into 7 cases according to selection of on/off. after measuring five times respectively, we obtained average value and calculated exposure dose. Image assessment was done with measured Modulation Transfer Function, Peak Signal to Noise Ratio, Root Mean Square, Signal to Noise Ratio, Contrast to Noise Ratio, Mean to Standard deviation Ratio respectively. In exposure assessment results, selection of two upper chambers was the lowest. In resolution assessment results, image of two upper chambers had the second high spatial frequency at sensitivity at 625(High) was 1.343 lp/mm. RMS value of image selecting two upper chambers was low secondly. SNR, CNR, MSR were the high value secondly. As the sensitivity was increased, radiation dose was decreased but better image could be obtained on image quality. In order to obtain the best medical images while minimizing the dose, usage of two upper ion chambers is considered to be clinically useful at sensitivity 625(High).

The Effects of High-dose Vitamin C Administration on the Cell-mediated Immune Response in Mice (다용량 비타민 C 투여가 생쥐 세포매개면역반응에 미치는 영향)

  • Noh, Kahwa;Kim, Heun-gon;Shin, Young-ah;Lim, Hyunja;Mun, Sung-kyu;Lee, Yongtaek;Lee, Wang Jae;Lee, Dongsup;Hwang, Young-il
    • IMMUNE NETWORK
    • /
    • v.3 no.3
    • /
    • pp.211-218
    • /
    • 2003
  • Background: Vitamin C is an essential nutrient, taken as a daily supplement by many people. Recently, high-dose vitamin C is considered as a therapeutic regimen in some clinical situations. Until now, few studies have been done with the effects of high-dose vitamin C on the immune response. Methods: In this experiment, the effects of high-dose vitamin C on cell-mediated immune response in immunologically competent mice were evaluated. After intraperitoneal injection of 2.5, 5, or 10 mg/day of vitamin C for 10 days, delayed type hypersensitivity (DTH) was provoked against DNFB in the pinnae as a model for cell-mediated immune response. Severity of DTH reaction was evaluated as the thickness of pinnae, and the vitamin C levels were measured in the serum, liver, kidney, lung, pinnae, and splenocytes. Results: After challenge, the thickness increased at its peak on the $2^{nd}$ day in all groups. On the first day, the pinnae were thicker in the injected groups than in the control. On the contrary, the increment of the pinnae thickness was attenuated and the number of cells infiltrated in the site of DTH decreased proportionately to the amount of vitamin C administered from the second day on. With vitamin C exogenously given, the serum level peaked at 30 min after injection, and returned abruptly to its basal level without accumulation. However, it accumulated in the liver, kidney, and especially in the pinnae inflamed and splenopcytes, proportionately to the amount administered. Conclusion: Based on these results, it is suggested that, in one hand, exogenously administered high-dose vitamin C accumulated in the splenocytes and presumably changed the function of them resulting in the augmented cell-mediated immune response, as was revealed in the first day of DTH reaction. On the other hand, it seems likely that the vitamin C also showed anti-inflammatory effects.

Evaluated Absorbed Dose According to Prescribed Dose and Therapeutic Technique in Radiation Therapy (방사선치료 시 처방선량과 치료기법에 따른 흡수선량 평가)

  • Lee, Deuk-hee;Park, Eun-tae;Kim, Jung-hoon;Im, In-chul
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.6
    • /
    • pp.469-476
    • /
    • 2016
  • In this study, evaluated absorbed dose of moving target using PLD according to prescribed dose and therapeutic technique. First, result of MCNPX when target was deviated from exposure field was reduced dose in proportion to distance. According to prescribed dose, absorbed dose of 3D CRT was better than IMRT in low dose and IMRT was more better in high dose. Absorbed dose of 3D CRT was highest according to therapeutic technique. Therefore, 3D CRT was technique of irradiated highest dose to moving target. But, considered protective effect of normal tissue and patient condition that therapeutic technique was selected to maximized treatment efficiency.

National trends in radiation dose escalation for glioblastoma

  • Wegner, Rodney E.;Abel, Stephen;Horne, Zachary D.;Hasan, Shaakir;Verma, Vivek;Ranjan, Tulika;Williamson, Richard W.;Karlovits, Stephen M.
    • Radiation Oncology Journal
    • /
    • v.37 no.1
    • /
    • pp.13-21
    • /
    • 2019
  • Purpose: Glioblastoma (GBM) carries a high propensity for in-field failure despite trimodality management. Past studies have failed to show outcome improvements with dose-escalation. Herein, we examined trends and outcomes associated with dose-escalation for GBM. Materials and Methods: The National Cancer Database was queried for GBM patients who underwent surgical resection and external-beam radiation with chemotherapy. Patients were excluded if doses were less than 59.4 Gy; dose-escalation referred to doses ≥66 Gy. Odds ratios identified predictors of dose-escalation. Univariable and multivariable Cox regressions determined potential predictors of overall survival (OS). Propensity-adjusted multivariable analysis better accounted for indication biases. Results: Of 33,991 patients, 1,223 patients received dose-escalation. Median dose in the escalation group was 70 Gy (range, 66 to 89.4 Gy). The use of dose-escalation decreased from 8% in 2004 to 2% in 2014. Predictors of escalated dose were African American race, lower comorbidity score, treatment at community centers, decreased income, and more remote treatment year. Median OS was 16.2 months and 15.8 months for the standard and dose-escalated cohorts, respectively (p = 0.35). On multivariable analysis, age >60 years, higher comorbidity score, treatment at community centers, decreased education, lower income, government insurance, Caucasian race, male gender, and more remote year of treatment predicted for worse OS. On propensity-adjusted multivariable analysis, age >60 years, distance from center >12 miles, decreased education, government insurance, and male gender predicted for worse outcome. Conclusion: Dose-escalated radiotherapy for GBM has decreased over time across the United States, in concordance with guidelines and the available evidence. Similarly, this large study did not discern survival improvements with dose-escalation.

Radiation Dose from Computed Tomography Scans for Korean Pediatric and Adult Patients

  • Won, Tristan;Lee, Ae-Kyoung;Choi, Hyung-do;Lee, Choonsik
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.3
    • /
    • pp.98-105
    • /
    • 2021
  • Background: In recent events of the coronavirus disease 2019 (COVID-19) pandemic, computed tomography (CT) scans are being globally used as a complement to the reverse-transcription polymerase chain reaction (RT-PCR) tests. It will be important to be aware of major organ dose levels, which are more relevant quantity to derive potential long-term adverse effect, for Korean pediatric and adult patients undergoing CT for COVID-19. Materials and Methods: We calculated organ dose conversion coefficients for Korean pediatric and adult CT patients directly from Korean pediatric and adult computational phantoms combined with Monte Carlo radiation transport techniques. We then estimated major organ doses delivered to the Korean child and adult patients undergoing CT for COVID-19 combining the dose conversion coefficients and the international survey data. We also compared our Korean dose conversion coefficients with those from Caucasian reference pediatric and adult phantoms. Results and Discussion: Based on the dose conversion coefficients we established in this study and the international survey data of COVID-19-related CT scans, we found that Korean 7-year-old child and adult males may receive about 4-32 mGy and 3-21 mGy of lung dose, respectively. We learned that the lung dose conversion coefficient for the Korean child phantom was up to 1.5-fold greater than that for the Korean adult phantom. We also found no substantial difference in dose conversion coefficients between Korean and Caucasian phantoms. Conclusion: We estimated radiation dose delivered to the Korean child and adult phantoms undergoing COVID-19-related CT examinations. The dose conversion coefficients derived for different CT scan types can be also used universally for other dosimetry studies concerning Korean CT scans. We also confirmed that the Caucasian-based CT organ dose calculation tools may be used for the Korean population with reasonable accuracy.

The Effect of Preoperative Interscalene Block Using Low-Dose Mepivacaine on the Postoperative Pain after Shoulder Arthroscopic Surgery (어깨 관절경 수술에서 저용량 Mepivacaine을 이용한 술전 사각근간 차단이 수술 후 진통에 미치는 효과)

  • Cho, Yong Hyun;Shin, Seung Ho;Lee, Dong Hyun;Yu, Eun Young;Yoon, Myo Seop
    • The Korean Journal of Pain
    • /
    • v.22 no.3
    • /
    • pp.224-228
    • /
    • 2009
  • Background: Shoulder arthroscopic surgery is frequently associated with severe postoperative pain, which can be difficult to manage without the use of high-dose opioids. Although an interscalene brachial plexus block (ISBPB) can be used to provide anesthesia for shoulder arthroscopic surgery, its effect using low-dose mepivacaine on postoperative pain management has not been reported. We hypothesized that ISBPB using a low-dose mepivacaine can provide effective postoperative analgesia for shoulder arthroscopic surgery without the need for high-dose opioids and act as a significant motor or sensory block. Methods: This study examined a total of 40 patients, who underwent shoulder arthroscopic surgery, and received ISBPB with 10 ml of normal saline (group NS; n = 20) or 10 ml of 1% mepivacaine with epinephrine 1:200,000 (group MC; n = 20). The block was performed preoperatively. The postoperative pain score, opioid consumption, and side effect were recorded. Results: The visual analog scale scores were significantly lower in group MC than in group NS at 120 minutes after shoulder arthroscopic surgery ($1.9{\pm}1.0$ versus $4.0{\pm}1.4$). Group MC showed significantly lower fentanyl consumption after shoulder arthroscoic surgery than group NS ($27{\pm}32.6$ versus $79{\pm}18.9{\mu}g$). The degree of motor and sensory block after surgery was minimal. Conclusions: ISBPB using low-dose mepivacaine reduced the level of postoperative pain and fentanyl consumption without significant side effects. ISBPB using low-dose mepivacaine is a useful analgesic technique for shoulder arthroscopic surgery.

Measurement of Patient Dose from Computed Tomography Using Physical Anthropomorphic Phantom (물리적 팬텀을 이용한 CT 촬영 환자의 피폭 선량 측정 및 평가)

  • Jang, Ki-Won;Lee, Choon-Sik;Kwon, Jung-Wan;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.3
    • /
    • pp.113-119
    • /
    • 2005
  • The computed tomogrpahy(CT) provides a high quality in images of human body but contributes to the relatively high patient dose. The frequency of CT examination is increasing and, therefore, the concerns about the patient dose are also increasing. In this study the experimental determination of patient dose was performed by using a physical anthropomorphic phantom and thermoluminescent dosimeter(TLD). The measurements were done for the both axial and spiral scan mode. As a result the effective doses for each scan mode were 17.78mSv and 10.01 mSv respectively and the fact that the degree of the reduction in the patient dose depends on the pitch scan parameter was confirmed. The measurement methods suggested in this study can be applied for the reassessment of the patient dose when the technique in CT equipment is developed or the protocol for CT scanning is changed.

A Study on the Image Quality and Patient Dose in Erect Simple Abdomen Radiography (복부 선자세 단순촬영시 화질과 피폭선량에 관한 연구)

  • Kim, Jung-Min;Hayashi, Taro;Ishida, Yuji;Sakurai, Tatsuya
    • Journal of radiological science and technology
    • /
    • v.21 no.1
    • /
    • pp.29-34
    • /
    • 1998
  • The purpose of simple abdomen erect projection is to see the fluid level which indicates gastrointestinal ileus or free air due to perforation. we do not have to insist on low kVp technique in simple abdomen erect position as long as we can detect the fluid level and free air shadow. Therefore, the author tried to decrease patient dose by high kVp technique and to improve the image quality due to motion artifact by reduction of exposure time. [Methods] Experiment 1. * screen/film SRO1000/HRH * exposure factor : $140\;kvp{\pm}5\;kv$ with added filters, 200 mA, 0.01 sec * phantom : Acryles : 15.0 cm(equivalent to 17 cm body thickness) 17.5 cm(equivalent to 21 cm body thickness) 20.0 cm (equivalent to 25 cm body thickness) With the exposure factor for same film density($D=0.8{\pm}0.1$) and with the materials above, we tried to find out entrance skin dose and gonad dose for both male and female. Experiment 2. Burger's phantom radiography were checked to see whether there was any change of image quality according to the kVp and the added filters. Experiment 3. Using rotating meter(self made), we examined the motion artifact and the exposure time limitation. [Results and conculution] 1. Using high voltage technique of 140 kVp with added filter, Skin dose, testicle dose and ovary dose decrease to 89.3%, 47% and 71.4% respectively compare to 70 kVp technique, 2. No great changes of Burger's phantom image has detected as from 70 kVp to 140 kVp and the air hole size of Burger's phantom over 0.028 cc(Diameter 3 mm, hight 4 mm) can be distinghished. 3. 0.01 sec(1 pulse) exposure time is possible in the single phase full wave rectification that why we can quitely reduce the unsharness caused by patient's movement.

  • PDF

Intraluminal High-Dose-Rate Brachytherapy for the Tumors of Gastrointestinal Tract (위장관 종양의 고선량율 강내 방사선치료)

  • Choi Byung Ock;Choi Ihl Bhong;Chung Su Mi;Kim In Ah;Choi Myoung Gyu;Chang Suk Kyun;Shinn Kyeong Sub
    • Radiation Oncology Journal
    • /
    • v.13 no.3
    • /
    • pp.243-252
    • /
    • 1995
  • Purpose : Intraluminal high dose rate brachytherapy is an accepted treatment for the tumors of GI tract. However, there is only some limited clinical data for intraluminal high dose rate brachytherapy for the tumors of GI tract. Materials and Methods : Between February 1991 and July 1993, 18 Patients who have the tumors of GI tract (esophageal cancer-8 cases, rectal cancer-10 cases) were treated with high dose rate Iridium-192 afterloading system (Microselectron-HDR, Nucletron CO, Netherland) at the department of therapeutic radiology, St. Mary's hospital, Catholic university medical college. Age range was 47-87 years with a mean a9e 71 years. All patients were treated with intraluminal high dose rate brachytherapy within two weeks after conventional external radiation therapy and received 3-5 Gy/fraction 3-4 times per week to a total dose 12-20 Gy (mean 17 Gy). Standard fractionation and conventional dose were delivered for external radiation therapy. Total dose of external radiation therapy ranged 41.4-59.4 Gy (mean 49.6 Gy). Median follow up was 19 months Results : The analysis was based on 18 patients, The complete response and partial response in esophageal cancer was similar (38%). Two year rates for survival and median survival were 13% and 10 months, respectively. Among 10 patients of rectal cancers, partial response was obtained in 6 patients (60%). There was no complete response in the patients with rectal cancer, but good palliative results were achieved in all patients. Conclusion : Although the number of patients was not large and the follow-up period was relatively short, these findings suggested that intraluminal high dose rate brachytherapy could be useful in the treatment of the patients with advanced tumors of GI tract.

  • PDF

Acute Effects of Ethanol on Blood Pressure and Renal Function in Rat (Ethanol 급성투여(急性投與)가 흰쥐의 혈압(血壓)과 신기능(腎機能)에 미치는 영향(影響))

  • Bae, Gui-Sook;Park, Jae-Sik;Lee, Won-Jung
    • The Korean Journal of Physiology
    • /
    • v.15 no.2
    • /
    • pp.103-109
    • /
    • 1981
  • In order to determine the dose-response relationship of ethanol on blood pressure and renal function, 2 doses of ethanol were intubated into albino rats. For a direct measurement of arterial blood pressure, a polyethylene catheter(PE 10) was implanted in the abdominal aorta, and the other end of the catheter was pulled out of the back of the neck. The experiment was conducted after the rats recovered from the surgery. After emptying their bladders, the rats were placed in a metabolism cage. Mean arterial pressure (MAP) was measured and arterial blood samples were collected through the catheter. Following the collection of the control urine sample, 1 ml of 10 g% (low dose), or 30 g% (high dose) of ethanol/100 g BW was intubated. 1 ml of water/100 g BW was intubated into the control group. MAP and blood samples were taken every hour, and urine samples were collected every 90 min for 3 hours. Blood alcohol concentrations reached a peak at 1 hour (low dose: $105.0{\pm}7.5$, high dose: $214.7{\pm}20.2\;mg%$) and decreased linearly thereafter. Following alcohol ingestion, MAP began to decrease at 15 min and remained at a significantly low level thoughout the 3 hours experimental period(low dose: $112{\pm}2{\rightarrow}102{\pm}4$, high dose: $117{\pm}2{\rightarrow}100{\pm}8\;mmHg$). Urine Flow increased markedly during the first 90 min of ethanol ingestion (low dose: $0.88{\pm}0.20{\rightarrow}1.04{\pm}0.22$, high dose: $0.56{\pm}0.11{\rightarrow}1.35{\pm}0.18\;ml/1.5\;hr$) and decreased during the second 90 min period(low dose: $0.25{\pm}0.06$, high dose: $0.22{\pm}0.06\;ml/1.5\;hr$). Urine flow of the control group decreased gradually during the experiment $(0.88{\pm}0.10{\longrightarrow}0.59{\pm}0.09{\rightarrow}0.45{\pm}0.09\;ml/1.5\;hr)$. These results indicate that the blood-pressure-lowering and diuretic effects of ethanol are dose-related: higher doses of ethanol produce a greater decrease in blood pressure and greater diuresis.

  • PDF