• Title/Summary/Keyword: High-Dose

Search Result 4,233, Processing Time 0.034 seconds

Fluoride removal using Alum & PACl in batch & continuous mode with subsequent microfiltration

  • Dubey, Swati;Agarwal, Madhu;Gupta, A.B.
    • Membrane and Water Treatment
    • /
    • v.12 no.2
    • /
    • pp.83-93
    • /
    • 2021
  • In this study, defluoridation efficiency by aluminium sulphate (alum) and polyaluminium chloride (PACl) were compared for recommended Nalgonda dose (100%) and 80% of this dose in both batch and continuous modes. The residual turbidity was found to be higher in case of alum as compared to PACl with 80% dose representing lesser efficient settling of suspensions, which primarily comprise alumino-fluoro complexes that result in high residual aluminium in the treated water and this was confirmed by TEM and Zeta analysis. Moreover, the application of PACl also resulted in much lesser addition to the TDS and also required lesser lime for pH compensation due to its lower acidity. Hence this reduced dose was recommended for defluoridation. It was also observed that in case of alum, residual aluminium in treated water was 0.88 mg/L (100% dose) & 0.72 mg/L (80% dose) and in case of PACl, it was 0.52 mg/L(100% dose) & 0.41 mg/L(80% dose). After subsequent microfiltration, residual aluminium was 0.28 & 0.21 mg/L for 100% & 80% dose respectively and in case of alum and in case of PACl, it was 0.16 & 0.11 for 100% & 80% dose respectively, which conform to the Al standards(<0.2 mg/L).

Evaluation of Patient Exposure Dose during Cardiac Electrophysiology Study under Various Conditions (심장 전기생리학 검사 시 조건 변화에 따른 환자 피폭 선량 평가)

  • Seong-Bhin Koh;Sung-Min Ahn
    • Journal of radiological science and technology
    • /
    • v.46 no.6
    • /
    • pp.501-508
    • /
    • 2023
  • This study used a adult absorption dose phantom (CIRS model 701-G, USA) made of human equivalent material and the vascular imaging equipment Allura Xper FD 20 (Philips, Netherlands). Optically stimulated luminescent dosimeters (OSLD) were inserted into the anatomical positions corresponding to each organ, and the exposure dose was measured. Dose area product (DAP) and air kerma (AK) measured by the dose meter in the equipment were compared. Continuous imaging was performed at two angles for a total of 20 minutes, with a frame per seconds of 3.75 and 7.5 fps and an FOV of 42 cm, 37 cm, and 31 cm, respectively, under the conditions of fluoflavor I, II, and III, each selected for 5 repetitions. This study was found that selecting a lower fps was the most effective way to reduce patient exposure dose, and adjusting the fluoflavor was a good alternative method for reducing patient exposure dose at high fps. Therefore the method of condition change with the greatest dose reduction effect is to set the minimum FPS and can reduce patient exposure dose according to geometric conditions and fluoflavor characteristics.

Study on a 4-Week Recovery Test of Sweet Bee Venom after a 13-Week, Repeated, Intramuscular Dose Toxicity Test in Sprague-Dawley Rats

  • Kang, Hyunmin;Lim, Chungsan;Lee, Seungbae;Kim, Byoungwoo;Kwon, Kirok;Lee, Kwangho
    • Journal of Pharmacopuncture
    • /
    • v.17 no.2
    • /
    • pp.18-26
    • /
    • 2014
  • Objectives: This study was performed to check for reversibility in the changes induced by a 13-week, repeated, dose toxicity test of Sweet Bee Venom (SBV) in Sprague-Dawley (SD) rats. Methods: Fifteen male and 15 female SD rats were treated with 0.28 mg/kg of SBV (high-dosage group) and the same numbers of male and female SD rats were treated with 0.2 mL/kg of normal saline (control group) for 13 weeks. We selected five male and five female SD rats from the high-dosage group and the same numbers of male and female SD rats from the control group, and we observed these rats for four weeks. We conducted body-weight measurements, ophthalmic examinations, urinalyses and hematology, biochemistry, histology tests. Results: (1) Hyperemia and movement disorder were observed in the 13-week, repeated, dose toxicity test, but these symptoms were not observed during the recovery period. (2) The rats in the high-dose group showed no significant changes in weight compared to the control group. (3) No significant differences in the ophthalmic parameters, urine analyses, complete blood cell counts (CBCs), and biochemistry were observed among the recovery groups. (4) No changes in organ weights were observed during the recovery period. (5) Histological examination of the thigh muscle indicated cell infiltration, inflammation, degeneration, necrosis of muscle fiber, and fibrosis during the treatment period, but these changes were not observed during the recovery period. The fatty liver change that was observed during the toxicity test was not observed during the recovery period. No other organ abnormalities were observed. Conclusion: The changes that occurred during the 13-week, repeated, dose toxicity test are reversible, and SBV can be safely used as a treatment modality.

N-methyl-D-aspartate (NMDA) and Non-NMDA Receptors are Involved in the Production and Maintenance of Nociceptive Responses by Intraplantar Injection of Bee Venom and Melittin in the Rat

  • Kim, Jae-Hwa;Shin, Hong-Kee
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.9 no.3
    • /
    • pp.179-186
    • /
    • 2005
  • Whole bee venom (WBV) and its major component, melittin, have been reported to induce long-lasting spontaneous flinchings and hyperalgesia. The current study was designed to elucidate the peripheral and spinal mechanisms of N-methyl-D-aspartate (NMDA) and non-NMDA receptors by which intraplantar (i.pl.) injection of WBV and melittin induced nociceptive responses. Changes in mechanical threshold and flinching behaviors were measured after the injection of WBV (0.04 mg or 0.1 mg/paw) and melittin (0.02 mg or 0.05 mg/paw) into the mid-plantar area of a rat hindpaw. MK-801 and CNQX (6-cyano-7-nitroquinoxaline-2,3-dione disodium) were administered intrathecally (i.t. $10{\mu}g$) or i.pl.($15{\mu}g$) 15 min before or i.t. 60 min after i.pl. WBV and melittin injection. Intrathecal pre- and postadministration of MK-801 and CNQX significantly attenuated the ability of high dose WBV and melittin to reduce paw withdrawal threshold (PWT). In the rat injected with low dose, but not high dose, of WBV and melittin, i.pl. injection of MK-801 effectively suppressed the decrease of PWTs only at the later time-points, but the inhibitory effect of CNQX (i.pl.) was significant at all time-point after the injection of low dose melittin. High dose WBV- and melittin-induced spontaneous flinchings were significantly suppressed by i.t. administration of MK-801 and CNQX, and low dose WBV- and melittin-induced flinchings were significantly reduced only by intraplantarly administered CNQX, but not by MK-801. These experimental flinchings suggest that spinal, and partial peripheral mechanisms of NMDA and non-NMDA receptors are involved in the development and maintenance of WBV- and melittin-induced nociceptive responses.

Comparison of the anesthetic effects of 2,2,2-tribromoethanol on ICR mice derived from three different sources

  • Lee, Mi Ree;Suh, Hye Rin;Kim, Myeong Whan;Cho, Joon Young;Song, Hyun Keun;Jung, Young Suk;Hwang, Dae Youn;Kim, Kil Soo
    • Laboraroty Animal Research
    • /
    • v.34 no.4
    • /
    • pp.270-278
    • /
    • 2018
  • This study was conducted to compare the anesthetic effects of 2,2,2-tribromoethanol (TBE, $Avertin^{(R)}$) in ICR mice obtained from three different sources. TBE (2.5%) was intraperitoneally injected at three doses: high-dose group (500 mg/kg), intermediate-dose group (250 mg/kg), and low-dose group (125 mg/kg). Anesthesia time, recovery time, end-tidal peak $CO_2$ ($ETCO_2$), mean arterial blood pressure, heart rate, oxygen saturation ($SpO_2$), body temperature, pH, $PCO_2$, and $PO_2$ of the arterial blood were measured. Stable anesthesia was induced by all doses of TBE and the anesthesia time was maintained exhibited dose dependency. No significant differences in anesthetic duration were found among the three different strains. However, the anesthesia time was longer in female than in male mice, and the duration of anesthesia was significantly longer in female than in male mice in the high-dose group. The recovery time was significantly longer for female than male mice in the intermediate- and high-dose groups. In the ICR strains tested, there were no significant differences in the mean arterial blood pressure, $SPO_2$, arterial blood $PCO_2$, and $PO_2$, which decreased after TBE anesthesia, or in heart rate and $ETCO_2$, which increased after TBE anesthesia. In addition, body temperature, blood biochemical markers, and histopathological changes of the liver, kidney, and lung were not significantly changed by TBE anesthesia. These results suggested that ICR mice from different sources exhibited similar overall responses to a single exposure to TBE anesthesia. In conclusion, TBE is a useful drug that can induce similar anesthetic effects in three different strains of ICR mice.

Evaluation of Dose Enhancement by Gold Nanoparticles using Mathematical Head Phantom (금 나노입자를 활용한 두부 모의피폭체에서의 선량증가 효과 평가)

  • Hwang, Chulhwan;Park, Eun-Tae;Kim, Jung-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.8
    • /
    • pp.477-483
    • /
    • 2016
  • The effect of dose enhancement was evaluated using Snyder head phantom, dependence on size of gold nanoparticle and material concentration in megavoltage X, ${\gamma}$-ray. Monte Carlo simulation using MCNPX was used for 4, 6, 10, 15 MV and Co-60 ${\gamma}$-ray. Described the tumor in Snyder head phantom, gold nanoparticle of 25, 75, 125nm diameter was inserted inside tumor. Concentration of dose enhancement material was used for 5, 15, 25 mg/g and dose enhancement factor was calculated on the basis of the no dose enhancement material. The lower incident energy and the higher concentration of material were that high dose enhancement factor is indicated. The size of gold nanoparticle had relatively high dependence on lower incident energy and higher concentration of material. It will increase dose inside the tumor, and be additional effect of use of gold nanoparticles in radiation therapy.

Mechanism of Radioresistance Induced by Low-Dose Irradiation (저준위 방사선에 의해 유도된 방사선저항의 기전)

  • Park, Sang-Hee;Cho, Chul-Koo;Yoo, Seong-Yul;Lee, Yeon-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.2
    • /
    • pp.99-105
    • /
    • 1996
  • After high-dose irradiation(8 Gy). the viability of lymphocyte with a prior low-dose irradiation was 3.7-fold higher than that without a prior low-dose irradiation The viability could be increased by the reduction of oxygen radicals or the removal of damaged molecules-DNA, protein. lipid membrane. or the removal of damaged cells. In this paper. we studied the radioresistance mechanism in lymphocytes and lymphoma cells by examining the activities of radical scavengers(catalase. peroxidase, superoxide dismutase, and glucose-6-phosphate dehydrogenase), and a radical protector(glutathione). Different enzymes were induced in lymphocyte and lymphoma with low-dose irradiation. The activity of peroxidase increased most(133.3%) in lymphoma while the enzymes increased most in lymphocyte were superoxide dismutase (138.5%), glucose-6-phosphate dehydrogenase (122.4%) and glutathione(120.8%). The activities of these enzymes were highest when the interval was 7 hours between low-dose and high-dose irradiation.

  • PDF

Dosimetric Characteristic of Digital CCD Video Camera for Radiation Therapy

  • Young Woo. Vahc;Kim, Tae Hong.;Won Kyun. Chung;Ohyun Kwon;Park, Kyung Ran.;Lee, Yong Ha.
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.147-155
    • /
    • 2000
  • Patient dose verification is one of the most important parts in quality assurance of the treatment delivery for radiation therapy. The dose distributions may be meaningfully improved by modulating two dimensional intensity profile of the individual high energy radiation beams In this study, a new method is presented for the pre-treatment dosimetric verification of these two dimensional distributions of beam intensity by means of a charge coupled device video camera-based fluoroscopic device (henceforth called as CCD-VCFD) as a radiation detecter with a custom-made software for dose calculation from fluorescence signals. This system of dosimeter (CCD-VCFD) could reproduce three dimensional (3D) relative dose distribution from the digitized fluoroscopic signals for small (1.0$\times$1.0 cm$^2$ square, ø 1.0 cm circular ) and large (30$\times$30cm$^2$) field sizes used in intensity modulated radiation therapy (IMRT). For the small beam sizes of photon and electron, the calculations are performed In absolute beam fluence profiles which are usually used for calculation of the patient dose distribution. The good linearity with respect to the absorbed dose, independence of dose rate, and three dimensional profiles of small beams using the CCD-VCFD were demonstrated by relative measurements in high energy Photon (15 MV) and electron (9 MeV) beams. These measurements of beam profiles with CCD-VCFD show good agreement with those with other dosimeters such as utramicro-cylindrical (UC) ionization chamber and radiographic film. The study of the radiation dosimetric technique using CCD-VCFD may provide a fast and accurate pre-treatment verification tool for the small beam used in stereotactic radiosurgery (SRS) and can be used for verification of dose distribution from dynamic multi-leaf collimation system (DMLC).

  • PDF

Assessment of Dose Distribution using the MIRD Phantom at Uterine Cervix and Surrounding Organs in High Doserate Brachytheraphy (자궁주위 방사선 근접치료시 MIRD 팬텀을 이용한 주변장기의 피폭환경평가)

  • Lee, Yun-Jong;Nho, Young-Chang;Lee, Jai-Ki
    • Korean Journal of Environmental Biology
    • /
    • v.24 no.4
    • /
    • pp.387-391
    • /
    • 2006
  • Computational and experimental dosimetry of Henschke applicator with respect to high dose rate brachytherapy using the MIRD phantom and a remote control afterloader were performed. A comparison of computational dosimetry was made between the simulated Monte Carlo dosimetry and GAMMADOT brachytherapy Planning system's dosimetry. Dose measurements was performed using ion chamber in a water phantom. Dose rates are calculated using Monte Carlo code MCNP4B and the GAMMADOT. Thecomputational models include the detailed geometry of Ir-192 source, tandem tube, and shielded ovoids for accurate estimation. And transit dose delivered during source extension to and retraction from a given dwell position was estimated by Monte Carlo simulations. Point doses at ICRU bladder/rectal pointswhich have been recommened by ICRU 38 was assessed. Calculated and measured dose distribution data agreed within 4% each other. The shielding effect of ovoids leads to 19% and 20% dose reduction at bladder surface and rectal points.