• Title/Summary/Keyword: High-Altitude Nuclear Explosion

Search Result 5, Processing Time 0.023 seconds

Simulation Study for Electromagnetic Pulse by High-Altitude Nuclear Explosion (고고도핵폭발 전자기펄스 피해 분석을 위한 전산모사 연구)

  • Kah, Dong-Ha;Shim, Woosup
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.822-828
    • /
    • 2015
  • This paper describes computer simulation program of high-altitude electromagnetic pulse (HEMP). The HEMP is produced by the gamma rays form high-altitude nuclear explosion. The gamma rays generate a current of compton electron that leads to the production of electromagnetic fields. In case of high altitude nuclear burst, the electrical fields at the earth's surface are strong enough to be damaged for electrical and electronic device over a very much larger area. Therefore, national infrastructure will be serious damage such as power grid and communication network. In this paper introduce simulation program for calculation of HEMP and present to simulation study results of high altitude nuclear explosion experiment from U.S. and U.S.S.R.

Electromagnetic Pulse Coupling into Naval Warship and Protective Measures (해군 함정에서의 EMP 영향 및 대책)

  • Yang, Jin-Ho;Nam, Sang-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.4
    • /
    • pp.426-433
    • /
    • 2014
  • The high-altitude electromagnetic pulse(HEMP) generated by a high-altitude nuclear explosion. This paper presents the comparison of electric field penetration in Bell laboratories and IEC 61000-2-9 standard when HEMP source penetrates through Naval Warship conducted coupling path and radiated coupling path. Also we analyze the effects of two kinds of coupling and propose Protective measures. Simulation results confirm IEC 61000-2-9 standard is more strict than the Bell Laboratories standard except for a lower frequency band, so we proposed IEC 61000-2-9 standard as a Naval HEMP standard. Finally, we offer the protective measures such as the shielding coating, Honeycomb ventilation, TVS in order to meet the military criteria.

Electromagnetic Modeling of High Altitude Electromagnetic Pulse Coupling into Large-Scale Underground Multilayer Structures (다층 지하 구조물로의 고고도 전자기파(HEMP) 커플링 현상에 대한 전자기적 모델링)

  • Kang, Hee-Do;Oh, Il-Young;Kim, Jung-Ho;Yook, Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.3
    • /
    • pp.392-401
    • /
    • 2012
  • This paper gives a electromagnetic coupling mechanism of the high altitude electromagnetic pulse (HEMP) into large- scale underground multilayer structures using analytic and numerical methods. The modeling methods are firstly addressed to the HEMP source which can be generated by intentional nuclear explosion. The instantaneous and intense electromagnetic pulse of the HEMP source is concerned from DC to 100 MHz band, because the power spectrum of the HEMP is rapidly decreased under -30 dB over the 100 MHz band. Through this range, a penetrated electric field distribution is computed within the large-scale underground multilayer structures. As a result, the penetrated electric field intensities at 0.1 and 1 MHz are about 10 and 5 kV/m, respectively. Therefore, additional shielding techniques are introduced to protect buried structures within the large-scale underground structures such as high-lossy material and filtering structures (wire screen).

Analysis of PCI Cable Effects in HEMP Conducted Disturbance (HEMP 전도성 방해 펄스 전류 주입(PCI) 케이블의 영향 분석)

  • Jang, Tae-Heon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.8
    • /
    • pp.772-780
    • /
    • 2013
  • The high-altitude electromagnetic pulse(HEMP) conducted environment and the HEMP radiated environment are established as the consequences of a high-altitude nuclear explosion. The IEC 61000-2-10, the international standard, defines the HEMP conducted environment. The IEC 61000-5-5 defines how protective devices for conducted disturbance proposed for HEMP protection shall be specified. The IEC 61000-4-24 deals with methods for testing protective devices for HEMP conducted disturbance. The IEC 61000-4-24:1997 mainly describes the measurement method of small protective components. However, it does not provide the measurement method for a combination filter of a protective component and a filter which is widely used in recent. It is important to consider the characteristic of the measurement setup parameters like thickness and length of the cable and its height above ground plane etc. in establishing measurement setup because HEMP conducted disturbances include the frequency spectrum below 50 MHz. This paper deals with the optimized measurement method, considering the frequency spectrum of HEMP conducted disturbance, current waveform, and analyzing the effects of cables existing in the measurement setup.

A Study for the Efficient Improvement Measures of Military EMP Protection Ability (국방 EMP 방호능력의 효율적 개선을 위한 방안 연구)

  • Jung, Seunghoon;An, Jae-Choon;Hwang, Yeung-Kyu;Jung, Hyun-Ju;Shin, Yongtae
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.7 no.1
    • /
    • pp.219-227
    • /
    • 2017
  • Current military command information system uses electronic equipment a lot on which semiconductor chip is attached. It seems its' importance will increase more with latest information communication technology developing. Electronic equipment which uses electricity contains regular tolerance to high output electric signal. And EMC specification is the standardized of this electronic equipment's tolerance. On the other hand, the Institute of Atomic Energy Research has ever declared that high output electromagnetic pulse(EMP) will be broken out within the radius of 170Km when 10kt nuclear explosion occurs at an altitude of 40Km above Seoul. Then, the region suffer from the damage of most electronic equipments. Therefore, the norm to protect the influences in that case is defined by EMP protection specification. Most common electronic equipments meet the EMC norm, but there is no way to check whether they meet the EMP norm or not. That is because it is difficult to check whether they meet EMP protection norm and is on the matter of cost. Except inevitable cases, there is no review of checking whether they meet the norm or not. Considering the above, in this research, we speculate about the measures to improve military EMP protection ability by analyzing the EMC-EMP correlation and checking the EMP protection ability of general electronic equipment through the analysis.