• 제목/요약/키워드: High voltage insulation material

검색결과 206건 처리시간 0.031초

발전소 고압전동기 열화 요인 분석 (A Survey of Deterioration Causes of High Voltage Motors in Power Plants)

  • 김경열;김희동;김병래;공태식;김병한;이상길;이종훤;최홍석
    • 한국전기전자재료학회논문지
    • /
    • 제24권10호
    • /
    • pp.807-811
    • /
    • 2011
  • When the high voltage motor fails in power plants, there will be an occurrence where the generator's output would be reduced or the generators would trip. Despite of these effects, the causes of deterioration of the high voltage motor is very seldom investigated. In this paper, the collected data which tested in the field over 10 years have been treated statistically, and analyzed to correlate the insulation deterioration of high voltage motor and installation environment, number of start/stop, and service life. Moreover, the proper period of insulation test is developed to map out maintenance strategy and reduce maintenance costs.

고분자복합소재차체를 적용한 바이모달트램의 전기적 절연 및 접지시스템에 관한 연구 (Study about Electrical Insulation and earthing system of Bimodal Tram with Polymer Composite Body)

  • 이강원;목재균;길경석;박대원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1063-1064
    • /
    • 2008
  • Bimodal tram has a carbody made of polymer composite material which is good electrical insulator. As an series hybrid type, Alternating voltage generated from generator coupled with CNG engine are rectified and transformed to variable voltage ranges which are applied to electrical apparatus and ECUs equipped inside of the tram. The failures of electrical insulation between high voltage($400V{\sim}800V$) and low voltage(24V) or between different kind of voltages such as AC and DC may cause some electrical interferences to prevent from operating rightly and other safety problem. This paper have investigated about the degradation factors of the electrical insulation and the earthing method available to bimodal tram, which is effective for preventing the electromagnetic interference coming from the inside or outside of tram but need some detecting measurements of earth leakage through electrical systems.

  • PDF

열수축형을 이용한 XLPE케이블 종단부의 전기적 특성 (Electrical Properties of XLPE Cable Termination using Thermal Contraction Type)

  • 백승명;최재형;최진욱;김상현;김영석;김선구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.395-396
    • /
    • 2009
  • For investigation of electrical properties of XLPE cable termination, we prepared a thermal contraction type kit and 6.6kV XLPE cable. The cable termination that have simulated defect by badness construction have been manufactured and their insulation characteristics such as ac and impulse withstand test have been measured. The influence of defects such as thickness decrease and heating time have been studied. When thickness decreased 1mm, the decreased of AC breakdown voltage value is not very distinctive. However, when thickness decreased 2mm, the insulation AC breakdown voltage value was very low down to 43kV. When approved heat for 300s than 60s, AC Breakdown voltage value appeared high. And also, after insulation breakdown took place, the sample was observed before and after disassembly, and the insulation breakdown hole was observed by means of optical microscope.

  • PDF

Toughened 에폭시와 실리콘고무 계면의 교류 절연파괴 현상에 관한 연구 (Study on the AC Interfacial Breakdown Properties in the Interface between toughened Epoxy and Silicone Rubber)

  • 박우현;이기식
    • 한국전기전자재료학회논문지
    • /
    • 제15권12호
    • /
    • pp.1079-1084
    • /
    • 2002
  • Because complex insulation method is used in EHV(extra high voltage) insulation systems, macro Interfaces between two different bulk materials which affect the stability of insulation system exist inevitably. Interface between toughened epoxy and silicone rubber was selected as a interface in EHV insulation systems and tested AC interfacial breakdown properties with variation of many conditions to influence on electrical Properties, such as interfacial pressure, roughness and oil. Specimen was designed to reduce the effect of charge transport from electrode in the process of breakdown and to have the tangential electrical potential with the direction of the interface between epoxy and silicone rubber by using FEM(finite elements method). It could control the interfacial pressure, roughness and viscosity of oil. From the result of this study, it was shown that the interfacial breakdown voltage is improved by increasing interfacial Pressure and oil. In particular, the dielectric strength saturates at certain interracial Pressure level. The decreasing ratio of the interfacial breakdown voltage in non-oiled specimen was increased by the temperature rising, while oiled specimen was not affected by temperature.

PDA를 이용한 고압전동기 고정자 권선에서 부분방전 특성 (Partial Discharge Properties of High Voltage Motor Stator Insulation using Partial Discharge Analyzer)

  • 김희동;이상길
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.225-228
    • /
    • 2001
  • Partial discharge(PD) testing for different capacitive couplers was performed on a 6.6kV, 448kW pulverizer motor. The motor has been in service for twenty years. PD tests were measured using digital partial discharge detector(DPDD) and partial discharge analyzer(PDA), respectively. PDA is used to in the motor stator insulation, which three 80pF or three 500pF epoxy-mica couplers were installed, one per phase. The 500pF couplers did detect more normalized quantity number(NQN) than the 80pF couplers. DPDD and PDA showed that PD and NQN magnitudes increased with increase of ac voltage. Internal discharge was discovered in the motor stator insulation. DPDD and PDA test results are in accordance with the pattern and magnitude of PD.

  • PDF

고온초전도 직류 케이블용 절연재료인 PPLP의 직류 및 임펄스 절연 특성 (DC and Impulse Insulation Characteristics of PPLP for HTS DC Cable)

  • 김우진;방만식;김해종;조전욱;김상현
    • 한국전기전자재료학회논문지
    • /
    • 제26권7호
    • /
    • pp.545-549
    • /
    • 2013
  • To realize the high-Tc superconducting (HTS) DC cable system, it is important to study not only high current capacity and low loss of conductor but also optimum electrical insulation at cryogenic temperature. A model HTS DC cable system consists of a HTS conductor, semi-conductor, cooling system and insulating materials. Polypropylene laminated paper (PPLP) has been widely adopted as insulating material for HTS machines. However, the fundamental insulation characteristics of PPLP for the development of HTS DC cable have not been revealed satisfactorily until now. In this paper, we will discuss mainly on the breakdown characteristics of 3 sheets PPLP in liquid nitrogen ($LN_2$). The characteristics of the diameter, location of butt-gap, distance between butt-gap length, pressure effect, polarity effect under DC and impulse voltage were studied. Also, the DC polarity reversal breakdown voltage of mini-model cable was measured in $LN_2$ under 0.4 MPa.

평등전계에서 SF6/CF4 혼합가스의 AC절연내력 특성 (AC Breakdown Voltage Characteristics of SF6/CF4 in Uniform field)

  • 황청호;박신우;김남렬;허창수
    • 한국전기전자재료학회논문지
    • /
    • 제20권4호
    • /
    • pp.381-387
    • /
    • 2007
  • The excellent dielectric properties of $SF_6$(sulfur hexafluoride) have lead to its wide range of application in the field of high voltage insulation. Because there has been some recent concern regarding the environmental impacts of $SF_6$ binary gas mixtures, with $SF_6$ as the main component, have been the subject of active research. Scientists have long been interested in the possible use of gaseous fluorocarbons, including $CF_4$ (Carton Tetrafluoride), in high voltage applications due to their inert character and high dielectric strength. This paper presents experimental results concerning the AC breakdown characteristics lot various mixtures of $SF_6/CF_4$ in a test chamber and 25.8 kV GIS (Gas Insulation Switchgear) at practical pressures (0.1-04 MPa) and gap lengths (0.5 mm, 1 mm) in a test chamber. In the result, it was observed that an increase in the dielectric strength is attained through the addition of $SF_6$ to $CF_4$. It is possible to make an environment friendly gas insulation material while maintaining the dielectric strength by combing $SF_6$ and $CF_4$ which generates a lower level of the "global warming" effect.

전기 방재를 위한 초고압케이블의 전기 전도 특성 (Electrical Conduction Characteristics of Ultra High Voltage Cable for Prevention of Electrical Fires)

  • 박희두;박하용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.216-217
    • /
    • 2007
  • In this paper we investigated the volume resistivity and AC conduction current according to the temperature and voltage. As a result, the volume resistivity comes to be small according to the measurement temperature and voltage. AC conduction current of the heat treatment specimen is increased because of the decrease of insulation.

  • PDF

고전계인가 고분자 절연재료의 전도현상에 관한 연구 (A Study on the Electrical Conduction in Insulation Material with High Voltage Treatment)

  • 임헌찬;정재희;이덕출
    • 한국안전학회지
    • /
    • 제9권1호
    • /
    • pp.56-60
    • /
    • 1994
  • In this study, Cuttent vs. Temperature characteristics of polyethylene with high-voltage treatment and crystallinity have been studied. The current curve( $I_{th}$) shows two peaks at 85 ($^{\circ}C$) and 50($^{\circ}C$), respectively. Trapping of carriers Proceeds during the high-field treatment, and it Is clear that 1th arises from the drift of carriers under the external voltage( $V_{b}$). From the results of TSC of BDPE and LDPE. It is realized that the traps are relation to the crystallinity.y.y.

  • PDF

The High Resistance Measurement up to 100 PΩ using a Low Resistance, a Low Voltage Source and a Commercial Digital Multimeter

  • Yu, Kwang Min;Lee, Sang Hwa;Kang, Jeon Hong;Kim, Wan-Seop
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1392-1397
    • /
    • 2018
  • The potentiometric measurement result for a high resistance up to $100P{\Omega}$ using a low resistance, a low voltage source and a commercial digital multimeter(DMM) is presented. With the method, a resistance can be easily, fast and economically measured. Using the method, resistance ranges over the $10G{\Omega}$ range which is difficult to measure using a commercial DMM and resistance ranges between $100T{\Omega}$ and $100P{\Omega}$ which cannot measure using an insulation tester were measured within accuracy of a few percent. It is expected that it can be useful to determine the temperature and voltage effect of a high resistance and an insulation material because it uses a reference resistance with a low resistance, very low temperature and voltage effect. Besides, it is expected that it can be useful to calibrate a dc high voltage divider with a large resistance ratio and a very low resistance because arbitrary resistance ratio measurements are possible with it.