• 제목/요약/키워드: High voltage electric field

검색결과 555건 처리시간 0.025초

평행판 전극과 전기장 센서를 이용한 교류 고전압 발생원의 측정범위 확장기술 개발 (Development for Measurement Range Extension Technique of AC High Voltage Source using Parallel Plates Electrode and Electric Field Sensor)

  • 강전홍;류제천;이상화;김규태;김명수;한상옥;정재갑
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권9호
    • /
    • pp.446-451
    • /
    • 2006
  • The output voltage value of AC high voltage source has been usually measured by employing the high voltage divider of inductive or capacitive type. In the study, we have developed a new method for measuring the output voltage up to 60kV using parallel plates electrode and electric field sensor, which are constructed by home-made. Unlikely the conventional method using a high voltage divider, this developed method makes it possible to extend the range of output voltage from known low voltage measurement to high voltage measurement. From the linearity measured between electric field and applied voltage in the output voltage range of 1kV-30kV, the output voltage value up to 60kV can be obtained by the electric field measurement using the electric field sensor. The output voltage value obtained using the method is consistent with that obtained using high voltage divider within corresponding uncertainties.

절연유의 도전전류와 직류절연파괴특성에 관한 연구 (A study on conduction current and D.C. breakdown characteristics in dielectric liquids)

  • 서국철
    • 전기의세계
    • /
    • 제30권4호
    • /
    • pp.231-236
    • /
    • 1981
  • It has been known that D.C. breakdown Voltage is lower than A.C. breakdown Voltage in insulatingoil, but there are still many unvivid points at electric conduction in breakdown or under of high electric field. This study measured the electric current-electric field characteristics (I-E characteristics) and the breakdown Voltage under of D.C. electric field of insulating oil using the system of electrodes that are near the Uniform electric field with a result. I can study, electric conduction in area of high electric field depends upon the Schottky effect. The liquidity of breakdown electric field takes place by the local concentration of electric field. The longer gap is and the more electric current is the more breakdown Voltage decreased. There are not almost the change of electric current-electric field characteristics by materials of electrode.

  • PDF

고전압 전력기기 개발을 위한 기중 절연파괴특성 분석에 관한 연구 (A Study on the Lightning Impulse Dielectric Characteristics of Air for the Development of Air-Insulated High Voltage Apparatuses)

  • 남석호;강형구
    • 전기학회논문지
    • /
    • 제60권5호
    • /
    • pp.1005-1010
    • /
    • 2011
  • The accidents caused by dielectric instability have been increasing in power grid. It is important to enhance the dielectric reliability of a high voltage apparatus to reduce the damage from electrical hazards. To develop an electrically reliable high voltage apparatus, the experimental study on the electrical breakdown field strength is indispensable, as well as theoretical approach. In this paper, the lightning impulse breakdown characteristics considering utilization factors are studied for the establishment of insulation design criteria of an high voltage apparatus. The utilization factors are represented as the ratio of mean electric field to maximum electric field. Dielectric experiments are performed by using several kinds of sphere-plane electrode systems made of stainless steel. As a result, it is found that dielectric characteristics are affected by not only maximum electric field intensity but also utilization factors of electrode systems. The results are expected to be applicable to designing the air-insulated high voltage apparatuses.

전기장 센서를 이용한 교류 400 kV 고전압 분압기의 제작 및 평가 (Fabrication and Evaluation of AC 400 kV High Voltage Divider using Electric Field Sensor)

  • 이상화;한상길;정재갑;강전홍;김윤형;정진혜;한상옥
    • 전기학회논문지P
    • /
    • 제57권3호
    • /
    • pp.265-269
    • /
    • 2008
  • Output voltage value of AC high voltage source has usually been obtained by measuring the low arm voltage of high voltage divider or the secondary voltage of high voltage transformer. In this study, we have fabricated the AC 400 kV high voltage divider using high voltage electrode and electric field measurement sensor. The dividing ratio of the fabricated 400 kV high voltage divider was evaluated using reference 400 kV capacitive divider. The dividing ratio of 400 kV high voltage divider is found to be 12,322 and has the good linearity within 0.63 % against AC high voltage up to 400 kV. Therefore, the developed 400 kV high voltage divider could evaluate 400 kV high voltage supply and voltage divider used in industry.

액체질소를 사용하는 초전도 고전압 전력기기의 절연 특성 연구 (Analytical and Experimental studies on Dielectric Characteristics of High Voltage Superconducting Machines in Liquid Nitrogen)

  • 나진배;고태국;강형구;석복렬;김태중
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제13권1호
    • /
    • pp.46-50
    • /
    • 2011
  • The electrical insulation design of high voltage superconducting fault current limiters (SFCLs) should be confirmed to be applied for the stabilization of the power grid. This paper describes numerical analysis and AC dielectric experiments for developing high voltage SFCLs. The electric field distributions between applied high voltage part and ground were calculated by finite element method (FEM) simulation tool and AC criterion of liquid nitrogen at 200 kPa was calculated from correlation between the field utilization factor and FEM simulation results. This paper deals with ceonceptual insulation design of a 154 kV class single-phase no-inductively wound solenoid type SFCL which was focused on gap distance between the cryostat and superconducting coils. Furthermore, the shield ring effect was confirmed to reduce maximum electric field at applied high voltage part.

고전압 전기장을 이용한 하수처리장 방류수 중의 대장균군 소독에 관한 연구 (A Study on the Disinfection of Coliform Group in the Effluent of Sewage Plant by High Voltage Electric Field Treatment)

  • 이민규;정근식;감상규
    • 한국환경과학회지
    • /
    • 제17권7호
    • /
    • pp.817-826
    • /
    • 2008
  • Using high voltage electric fields induced by high voltage AC (10-12 kV/cm, 20 kHz) and pulsed (20-30 kV/cm, 40 Hz) electric field generator as a semipermanent and environment-friendly disinfecting apparatus, the disinfection effect of coliform group in the effluent of sewage plant was investigated. The effects of electric field strength, treatment time, discharge area of a discharge tube, water quality factors (electric conductivity, pH and SS) on its death rate were examined. The death rate of coliform group was increased with increasing electric field strength and treatment time. For AC and pulsed electric field generator, the critical electric field strength was 6 kV/cm and 2 kV/cm, respectively, and the critical treatment time was 5 min and 2 min, respectively, regardless of electric field strength. Comparing the death rate of coliform group by AC and pulsed electric fields used in this study, its death rate was higher for the latter than the former, but did not increase linearly with increasing electric field strength. The results obtained for the effects of discharge area, electric conductivity, pH and SS on the death rate of coliform group using AC electric field (12 kV/cm, 20 kHz) were as follows: its death rate showed the trend to increase linearly with increasing discharge area; for the effect of electric conductivity, its death rate was increased with increasing electric conductivity, regardless of ionic species, increased with increasing cationic valency, but was similar between the same cationic valency; the pH $5{\sim}9$ used in this study did not affect its death rate; its death rate was decreased with increasing SS concentration.

교류전기장이 프로판 난류제트 화염의 부상특성에 미치는 영향 (A Study on the Effect of AC Electric Field on the Liftoff Characteristics of Turbulent Propane Jets.)

  • 박철수;이상민;차민석;정석호
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2004년도 제28회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.83-88
    • /
    • 2004
  • High voltage AC electric field has been applied to turbulent propane jets to investigate the effect of electric field on liftoff characteristics. Liftoff velocity and liftoff height have been measured by varying the applied voltage and frequency. Liftoff velocities were delayed and liftoff heights were reduced by applying AC, not by DC. The electric effect became disappeared with further increasing jet velocities, which shows that the effect can be explained by the balance between inertia force and electric force. The flame stabilization effect was intensified as either applied voltage or frequency increased. Plasma streamers were generated between the flame and the jet under high voltage conditions. Liftoff velocity in the absence of plasma can be well correlated by the function of voltage and frequency.

  • PDF

자가 발전 시스템을 갖춘 고전압 전기장 수질개선 장치 개발 (Water Quality Improvement System Using High Voltage Electric Field with Self-Generation System)

  • 강래윤;강철웅
    • 동력기계공학회지
    • /
    • 제19권2호
    • /
    • pp.84-89
    • /
    • 2015
  • The occurrence of algae caused by eutrophication of fresh water is a pollution source to destroy the aquatic environment. When the high voltage electric field is applied in the water, When a high voltage is applied to the electric field in the water, the algae can be broken the balance of cell membranes, and is dead. In this paper, we develop a water quality improvement system for generating an electric field having a higher energy than the zeta potential when a high voltage is applied to 4,000V. To ensure the mobility of the water quality improvement system, we designed the PV generation system using the optimal size technique that is based on the model of power lack ratio. By evaluating the output characteristics of the water quality improvement system, power generation characteristics of the PV generation system, and battery charging characteristics, we can show that the proposed system can be applicable to the water quality improvement system inhibiting the growth rate of the algae in the fresh water.

전류자극 및 전기장 처리가 현미 발아에 미치는 영향 (Effects of Electric Current Stimuli and High-Voltage Electric Field Treatments on Brown Rice Germination)

  • 임기택;김장호;선우훈;홍지향;정종훈
    • Journal of Biosystems Engineering
    • /
    • 제35권2호
    • /
    • pp.100-107
    • /
    • 2010
  • This study was conducted to investigate the effects of electric current stimuli and high-voltage electric field treatments on brown rice germination. The brown rice stimulated by electrical current stimuli, functional electrical stimuli of a pulse type, and high-voltage electric field treatments were observed (Type I, II and III). Treatment Type I was a method of semi-soaking brown rice with electric current stimuli of 0.13 V/cm, 0.19 V/cm, and 0.25 V/cm into Petri-dishes for 72 hours. Type II was a method of semi-soaking brown rice with functional electrical stimuli of a pulse type(DC 1 V, 1 Hz, 5%, and duty cycles of 5%, 20%, and 35%) into Petri-dishes for 72 hours. Type III was a method of water-soaking with high-voltage electric field treatments for 60 hours. High-voltage electric field treatments at 15 kV/cm were also conducted for 2.5 min, 7.5 min, and 10 min, respectively. The germination rate and the sprout growth of brown rice germinated by electric current stimuli with 0.13 V/cm, 0.19 V/cm, and 0.25 V/cm were increased by about 10-15% compared with those of the control group. The germination rate and the sprout growth of brown rice germinated by functional electrical stimuli of pulse type(DC 1 V, 1 Hz, 5% duty cycle) were increased by about 10∼15% compared to those of the control group. Also, the best effective treatment among high-voltage electric field treatments was the 10 min group at 15 kV/cm. The germination rate and the sprout growth of brown rice germinated by this treatment of 10 min at 15 kV/cm were increased by about 10∼20% compared to those of the control group. The treatments of electric current stimuli and high-voltage electric field accelerated the germination rate and sprout growth of brown rice by about 10∼15% compared to those of the control group.

전기장이 튜브내 예혼합화염 전파속도에 미치는 영향에 관한 연구 (Effect of Electric Fields on Flame Speed of Propagating Premixed Flames in Tube)

  • 류승관;원상희;차민석;정석호
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2006년도 제32회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.137-143
    • /
    • 2006
  • The effect of electric fields on flame speed has been investigated experimentally by observing propagating premixed flames in a tube for methane/air mixtures. The flame speeds were measured in both the normal and micro gravity conditions to substantiate the measurements. The results show that the flame speeds were enhanced by both the AC and DC electric fields, as the flame approached to the high voltage electrode located on the one end of the tube. The enhancement of flame speed was proportional to the square root of the electric field intensity, defined as the voltage applied divided by the distance of flame from the high voltage electrode, when the electric field intensity is sufficiently large. When the electric field intensity was low, there existed critical intensities, below which the electric fields did not influence the flame speed. This critical electric field intensity correlated well with the flame speed.

  • PDF