• Title/Summary/Keyword: High temperature gas

Search Result 3,297, Processing Time 0.03 seconds

High-Temperature Structural Analysis on the Small-Scale PHE Prototype using Weld Properties (용접물성치를 고려한 소형 공정열교환기 시제품의 고온구조해석)

  • Song, Kee-Nam;Hong, Sung-Deok;Park, Hong-Yoon
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.8 no.2
    • /
    • pp.1-6
    • /
    • 2012
  • A PHE (Process Heat Exchanger) in a nuclear hydrogen system is a key component required to transfer heat energy of $950^{\circ}C$ generated in a VHTR (Very High Temperature gas cooled Reactor) to the chemical reaction that yields a large quantity of hydrogen. A small-scale PHE prototype made of Hastelloy-X is being tested in a small-scale gas loop at Korea Atomic Energy Research Institute. Previous research on the high-temperature structural analysis of the small-scale PHE prototype had been performed only using parent material properties. In this study, high-temperature structural analysis using weld properties in weld zone was performed and the analysis results compared with the previous research.

The Study on the Formation Mechanism of Gas Pore During Lost Foam Casting of Al alloys (알루미늄 합금의 소실모형주조 중 기포 형성 기구에 관한 연구)

  • Shin, Seung-Ryoul;Han, Sang-Won;Lee, Kyong-Whoan;Lee, Zin-Hyoung
    • Journal of Korea Foundry Society
    • /
    • v.23 no.5
    • /
    • pp.268-275
    • /
    • 2003
  • The mechanism of the hydrogen gas pore formation was investigated in Lost Foam Casting of Al-alloy by reduced pressure test and real casting. The hydrogen gas pick-up was affected by the formed gas during the decomposition of polystyrene in addition to the liquid product. It depended on pouring temperature and a proper temperature of metal front gave the minimum hydrogen pick-up. At a low pouring temperature, the hydrogen went into the melt mainly from entrapped liquid product of polystyrene but pores were formed from the gas as well as the liquid product at a high pouring temperature. The mold flask evacuation down to 710torr decreased the gas porosity down by around 0.4% vol%. The entrapped decomposition product of polystyrene in the melt was observed through the visualization of filling behavior of Al alloy-melt with the high speed camera.

A Study on Coupled Field Analysis of 3-D Gas Turbine Blade (3차원 가스터빈 블레이드의 연성 해석에 관한 연구)

  • Park Keun-Hyung;Min Taeg-Ki;Park Chang-Soo
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.2
    • /
    • pp.38-43
    • /
    • 2006
  • A turbine blade operates under high temperature, high pressure, and the loads have the characteristics that the amplitudes change. Therefore, it is important to perform a stress analysis considering thermal and pressure loads. The purpose of this study is to investigate the effects of these loads on gas turbine blade through thermal stress analysis. The analysis results shows that pressure in gas fluid flow around blade is high in leading edge part, Gas temperature is connections with pressure of flow around blade. The distribution of stress from blade is appearing as is different at suction side and pressure side.

Suggestion of Structural Sizing Methodology on a Coaxial Double-tube Type Hot Gas Duct for the VHTR (초고온가스로의 동심축 이중관형 고온가스덕트에 대한 구조정산 방법론 제안)

  • Song, Kee-Nam;Kim, Y.W.
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.717-724
    • /
    • 2008
  • Very High Temperature Gas Cooled Reactor (VHTR) has been selected as a high energy heat source for nuclear hydrogen generation, which can produce hydrogen from water or natural gas. A primary hot gas duct (HGD) as a coaxial double-tube type cross vessel is a key component connecting the reactor pressure vessel and the intermediate heat exchanger for the VHTR. In this study, structural sizing methodology for the primary HGD with a coaxial double-tube of the VHTR that produces heat at temperatures in the order of $950^{\circ}C$ was suggested and a structural pre-sizing of it was carried out as an example.

  • PDF

The effect of gas density on the drop trajectory and drop size distribution in high speed gas stream (고속기류에 분사된 액적궤적 및 입경분포에 미치는 주위 기체밀도의 영향)

  • Lee, C.H.
    • Journal of ILASS-Korea
    • /
    • v.5 no.3
    • /
    • pp.37-44
    • /
    • 2000
  • High velocity, gas-assisted liquid drop trajectories were investigated under well-controlled experimental conditions at elevated gas densities and room temperature. A monodisperse stream of drops which are generated by a vibrating-orifice drop generator were injected into a transverse high velocity gas stream. The gas density and air jet velocity were adjusted independently to keep the Weber numbers constant. The Weber numbers studied were 72, 148, 270, 532. The range of experimental conditions included studied the three drop breakup regimes previously referred as bag, stretching/thinning and catastrophic breakup regimes. High-magnification photography and conventional spray field photographs were taken to study the microscopic breakup mechanisms and the drop trajectories in high velocity gas flow fields, respectively. The parent drop trajectories were affected by the gas density and the gas jet velocities and do not show similarity with respect to the either Weber or the Reynolds number, as expected.

  • PDF

Temperature Compensation of NDIR $CO_{2}$ Gas Sensor Implemented with ASIC Chip (ASIC 칩 내장형 비분산 적외선 이산화탄소 가스센서의 온도보상)

  • Yi, Seung-Hwan;Park, Jong-Seon
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.1 s.34
    • /
    • pp.40-45
    • /
    • 2007
  • This paper describes NDIR $CO_{2}$ gas sensor that shows the characteristics of temperature compensation. It consists of novel optical cavity that has two elliptical mirrors and a thermopile that includes ASIC chip in the same metal package for the amplification of detector output voltage and temperature sensor. The newly developed sensor module shows high accuracy ($less\;than {\pm}40\;ppm$) throughout the measuring concentration of $CO_{2}$ gas from 0 ppm to 2,000 ppm. After implementing the calculation methods of gas concentration, which is based upon the experimental results, the sensor module shows high accuracy less than ${\pm}5\;ppm$ error throughout the measuring temperature range ($15^{\circ}C\;to\;35$^{\circ}C$) and gas concentrations with self-temperature compensation.

  • PDF

A Study on the Occurrence Character of Contaminant in the Kitchen that Use Gas Fuel (가스를 연료로 사용한 주방에서의 오염물질 발생 특성에 대한 연구)

  • 박명길;함진식
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2001.11a
    • /
    • pp.77-82
    • /
    • 2001
  • This paper is contents that measure the ventilation rates and temperature by driving condition of exhaust fan, vapor, contaminant occurrence amount of carbon dioxide etc. In kitchen of apartment house. The ventilation rates in the apartment kitchen measured by Tracer Gas Method. And, temperature of when cook by gas table hood lower part 10cm and floor upside 10cm of kitchen central part, 120cm, 210cm heights measure. As ventilation rates measurement result, ventilation number of times was 0.7(number of times/hour) when did not to operate exhaust fan. but we were measured by 2.3(number of times/hour) when drove strongly. As temperature measurement result at cooking by gas table, temperature showed highest in hood lower part 10cm of case that do not operate exhaust fan. Temperature at kitchen central was most low in 10cm height in talc floor, and 210cm were measured highest. Concentration of carbon dioxide is very high by 4,350ppm after measurement time 10 minutes in state who do not operate exhaust fan at cooking by gas table.

  • PDF

A Study on Quenching Characteristics of a High Pressure Gas Quenching System (고압가스 냉각시스템의 특성 연구)

  • Kim, Han-Seok;An, Guk-Yeong;Lee, Sang-Min;Jang, Byeong-Rok
    • 연구논문집
    • /
    • s.34
    • /
    • pp.11-19
    • /
    • 2004
  • An Experimental study on the characteristics of high pressure gas quenching system was carried out in the present study. The characteristics of gas quenching system have been studied with high pressure gas chamber and specimen for various gas pressure and velocity which are the design parameter of quenching system. The quenching gas was used compressed air which properties are very similar with Nitrogen gas usually used in industrial gas quenching system. The result shows that the quenching rate of mid surface of specimen is lower than each ends of them which are close to low temperature quenching surface. And to increases the quenching intensity, the increment of quenching gas pressure is more efficient than the increment of quenching gas velocity at the point of reducing the circulation fan power.

  • PDF

MOLECULAR SCALE MECHANISM ON EVAPORATION AND REMOVAL PROCESS OF ADHERENT MOLECULES ON SURFACE BY BURNT GAS

  • Yang, Y.J.;Lee, C.W.;Kadosaka, O.;Shibahara, M.;Katsuki, M.;Kim, S.P.
    • International Journal of Automotive Technology
    • /
    • v.7 no.2
    • /
    • pp.121-128
    • /
    • 2006
  • The interaction between adherent molecules and gas molecules was modeled in the molecular scale and simulated by the molecular dynamics method in order to understand evaporation and removal processes of adherent molecules on metallic surface using high temperature gas flow. Methanol molecules were chosen as adherent molecules to investigate effects of adhesion quantity and gas molecular collisions because the industrial oil has too complex structures of fatty acid. Effects of adherent quantity, gas temperature, surface temperature and adhesion strength for the evaporation rate of adherent molecules and the molecular removal mechanism were investigated and discussed in the present study. Evaporation and removal rates of adherent molecules from metallic surface calculated by the molecular dynamics method showed the similar dependence on the surface temperature shown in the experimental results.

A Study on the Effect of Turbulent Combustion upon Soot Formation in Premixed Constant-Volume Propane Flames (정적 예혼합 프로판 화염의 매연생성에 미치는 난류연소 영향에 관한 연구)

  • 배명환;안수환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.7
    • /
    • pp.889-898
    • /
    • 2003
  • The soot yield is studied by a premixed propane-oxygen-inert gas combustion in a specially designed disk-type constant-volume combustion chamber to investigate the effect of turbulence on soot formation. Premixtures are simultaneously ignited by eight spark plugs located on the circumference of chamber at 45 degree intervals in order to observe the soot formation under high pressures and high temperatures. The eight flames converged compress the end gases to a high pressure. The laser schlieren and direct flame photographs for observation field with 10 mm in diameter are taken to examine into the behaviors of flame front and gas flow in laminar and turbulent combustion. The soot volume fraction in the chamber center during the final stage of combustion at the highest pressure is measured by the in situ laser extinction technique and simultaneously the corresponding burnt gas temperature by the two-color pyrometry method. It is found that the soot yield of turbulent combustion decreases in comparison with that of laminar combustion because the burnt gas temperature increases with the drop of heat loss.