• Title/Summary/Keyword: High temperature desulfurization

Search Result 44, Processing Time 0.022 seconds

Study on the In-Furnace Desulfurization for Oxy-Fuel Combustion Flue Gases Using Drop Tube Furnace (Drop Tube Furnace를 이용한 순산소연소 배가스 로내탈황에 관한 연구)

  • An, Young-Mo;Jo, Hang-Dae;Choi, Won-kil;Park, Yeong-Sung;Keel, Sang-In;Lee, Hyung-Keun
    • Korean Chemical Engineering Research
    • /
    • v.47 no.4
    • /
    • pp.512-517
    • /
    • 2009
  • $SO_2$ concentrations in oxy-fuel combustion flue gases increases about three times as high as that of conventional air combustion system owing to the flue gas recirculation for the control of combustion temperature. So the desulfurization reaction is different from that of the conventional air combustion system due to exceptionally high $CO_2$ and $SO_2$ concentration. In this study, drop tube furnace(DTF) system was used to investigate the desulfurization characteristics of limestone in oxy-fuel combustion furnace. The experiments were performed under $O_2/CO_2$ atmosphere to examine the effect of operating variables such as reaction temperatures, Ca/S ratios and inlet $SO_2$ concentrations on the $SO_2$ removal efficiencies. $SO_2$ removal efficiency increased with reaction temperature, Ca/S ratio and inlet $SO_2$ concentration. And the addition of water vapor resulted in about 4~6% of increase in $SO_2$ removal efficiency.

Study on the Desulfurization Characteristic of Limestone Depending on the Operating Parameters of In-Furnace Desulfurization for Oxy-Fuel Combustion Using Drop Tube Furnace (순산소연소 조건에서 Drop tube furnace를 이용한 운전변수에 따른 석회석의 탈황특성 연구)

  • Choi, Wook;Jo, Hang-Dae;Choi, Won-Kil;Park, Yeong-Sung;Keel, Sang-In;Lee, Hyung-Keun
    • Korean Chemical Engineering Research
    • /
    • v.49 no.6
    • /
    • pp.857-864
    • /
    • 2011
  • Oxy-fuel combustion with many advantages such as high combustion efficiency, low flue gas flow rate and low NOx emission has emerged as a promising CCS technology for coal combustion facilities. In this study, the effects of the direct sulfation reaction on $SO_2$ removal efficiency were evaluated in a drop tube furnace under typical oxy-fuel combustion conditions represented by high concentrations of $CO_2$ and $SO_2$ formed by gas recirculation to control furnace combustion temperature. The effects of the operating parameters including the reaction temperature, $CO_2$ concentration, $SO_2$ concentration, Ca/S ratio and humidity on $SO_2$ removal efficiency were investigated experimentally. $SO_2$ removal efficiency increased with reaction temperature up to 1,200 due to promoted calcination of limestone reagent particles. And $SO_2$ removal efficiency increased with $SO_2$ concentrations and the humidity of the bulk gas. The increase of $SO_2$ removal efficiency with $CO_2$ concentrations showed that $SO_2$ removal by limestone was mainly done by the direct sulfation reaction under oxy-fuel combustion conditions. From the impact assessment of operation parameters, it was shown that these parameters have an effects on the desulfurization reaction by the order of the Ca/S ratio > residence time > $O_2$ concentration > reaction temperature > $SO_2$ concentration > $CO_2$ concentration > water vapor. The semi-empirical model equation for to evaluate the effect of the operating parameters on the performance of in-furnace desulfurization for oxy-fuel combustion was established.

A Study on Reaction Characteristics of Fe$_2$O$_3$High-Temperature Desulfurization Sorbents (Fe$_2$O$_3$계 고온건식탈황제의 반응특성 연구)

  • Kang, Suk-Hwan;Rhee, Young-Woo;Kang, Yong;Han, Keun-Hee;Yi, Chang-Keun;Jin, Gyoung-Tae;Son, Jae-Ek;Park, Yeong-Seong
    • Journal of Energy Engineering
    • /
    • v.5 no.2
    • /
    • pp.123-130
    • /
    • 1996
  • Reduction, sulfidation, and regeneration reactions were performed using domestic and Australian iron ore in order to develop a desulfurizing sorbent for the high temperature desulfurization process that is one of major processes in the integrated coal gasification combined cycle (IGCC) system. A TGA (Thermogravimetric Analysis) reactor and a fixed-bed reactor were used. Some basic kinetic information was obtained from BET surface area measurements, SEM photos, cyclic reactions, reaction temperature changes and TGA curves of the sorbents. The rates of both desulfurization and regeneration increased with increasing reaction temperature in the range of 500-700$^{\circ}C$.

  • PDF

Study of Kinetics for Removal H2S by Natural Manganese ore Sorbent (황화수소 제거를 위한 천연망간광석 탈황제의 반응 속도 연구)

  • Yoon, Yeo Il;Kim, Myung Wook;Kim, Sung Hyun
    • Clean Technology
    • /
    • v.7 no.3
    • /
    • pp.187-194
    • /
    • 2001
  • The desulfurization process which belongs to the gas refining part is the unit process that eliminates $H_2S$ and COS in the coal gas formed by the coal gasification part in the integrated gasification combined cycle(IGCC). In this study, natural manganese ores were selected as the raw material of the desulfurization sorbent due to economical efficiency. Initial rates for the reactions between $H_2S$ and desulfurization sorbent using natural manganese ores were determined in a temperature range of $400{\sim}800^{\circ}C$ using a thermobalance reactor. All reactions were first order with respect to $H_2S$ and were in accord with the Arrhenius equations. When sulfidation reaction was controlled by diffusion, the temperature dependence of the effective diffusivity was given by the Arrhenius equation. Activation energies and frequency factors were obtained from the product layer diffusion coefficient of various sorbents by plotting as Arrhenius equation form.

  • PDF

A Study on Preparation and Reactivity of Zinc Titanate Sorbents for H2S Removal (아연-티타늄 복합산화물 탈황제의 제조 및 반응특성 연구)

  • Kim, Ki-Seok;Park, No-Kuk;Lee, Tae-Jin
    • Applied Chemistry for Engineering
    • /
    • v.8 no.1
    • /
    • pp.122-131
    • /
    • 1997
  • Zinc titanate sorbents for $H_2S$ removal were prepared and their reactivities were studied for high temperature desulfurization of coal gas. Sulfidation of zinc titanates by $H_2S$ sorption was conducted in a packed-bed tubular flow reactor at the temperature range of $550{\sim}750^{\circ}C$, and the results reveal that $650^{\circ}C$ was the optimal sulfidation temperature with respect to desulfurization efficiency and zinc loss. The structural change of sorbent particle was investigated by SEM analysis for the forbents sulfided at $650^{\circ}C$ and subsequently regenerated at $750^{\circ}C$. The stability of desulfurization capability as well as the mechanical stability of the zinc titanates was studied by means of the successive cycles of sulfidation-regeneration of sorbents, and the sorbent samples taken after the 10th cycle were characterized using BET, XRD, and SEM/EDX analyses. Zinc titanate sorbents exhibited nearly constant desulfurization capability in the successive cycle operation.

  • PDF

The Utilization of Waste Seashell for High Temperature Desulfurization

  • Kim, Young-Sik;Hong, Sung-Chul
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.2
    • /
    • pp.136-140
    • /
    • 2010
  • The integrated gasification combined cycle (IGCC) is one of the most promising proposed processes for advanced electric power generation that is likely to replace conventional coal combustion. This emerging technology will not only improve considerably the thermal efficiency but also reduce or eliminate the environmentally adverse effects normally associated with coal combustion. The IGCC process gasifies coal under reducing conditions with essentially all the sulfur existing in the form of hydrogen sulfide ($H_2S$) in the product fuel gas. The need to remove $H_2S$ from coal derived fuel gases is a significant concern which stems from stringent government regulations and also, from a technical point of view and a need to protect turbines from corrosion. The waste seashells were used for the removal of hydrogen sulfide from a hot gas stream. The sulphidation of waste seashells with $H_2S$ was studied in a thermogravimetric analyzer at temperature between $600^{\circ}C$ and $800^{\circ}C$. The desulfurization performance of the waste seashell sorbents was experimentally tested in a fixed bed reactor system. Sulfidation experiments performed under reaction conditions similar to those at the exit of a coal gasifier showed that preparation procedure and technique, the type and the amount of seashell, and the size of the seashell affects the $H_2S$ removal capacity of the sorbents. The pore structure of fresh and sulfided seashell sorbents was analyzed using mercury porosimetry, nitrogen adsorption, and scanning electronmicroscopy.

The utilization of waste seashell for high temperature desulfurization

  • Kim, Young-Sik;Kim, Taek-Geun;Sim, Eon-Bong;Seo, Jeong-Min
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.12a
    • /
    • pp.66-71
    • /
    • 2005
  • The waste seashells were used for the removal of hydrogen sulfide from a hot gas stream. The sulphidation of waste seashells with $H_2S$ was studied in a thermogravimetric analyzer at temperature between 600 and 800$^{\circ}C$. The desulfurization performance of the waste seashell sorbents was experimentally tested in a fixed bed reactor system. Sulfidation experiments performed under reaction conditions similar to those at the exit of a coal gasifier showed that preparation procedure and technique, the type and the amount of seashell, and the size of the seashell affect the $H_2S$ removal capacity of the sorbents. The pore structure of fresh and sulfided seashell sorbents was analyzed using mercury porosimetry, nitrogen adsorption, and scanning electron microscopy.

  • PDF

The Effect of ZnO Content on the Performance of Spray-dried Zn-based Desulfurization Sorbent for H2 Cleanup (황화수소 정제용 아연계 분무건조 탈황제의 활성성분 함량 변경에 따른 물성 및 반응 특성)

  • Baek, Jeom In;Eom, Tae Hyoung;Lee, Joong Beom;Jegarl, Seong;Ryu, Chong Kul
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.25 no.5
    • /
    • pp.482-490
    • /
    • 2014
  • Gaseous sulfur compound such as $H_2S$ or COS in coal- or biomass-derived hot syngas can be purified by solid sorbents at high temperatures. In this study, we investigated the physical properties and reactivity of solid regenerable desulfurization sorbents with 37.2, 41.9, and 46.5wt% ZnO to look into the ZnO content effect. The sorbents were produced by spray-drying method to apply to a fluidized-bed process. Sulfidation and regeneration reaction were carried out using a thermogravimetric analyzer. Sorbent prepared with 46.5wt% ZnO had physical properties suitable for a fluidized-bed process applications such as spherical shape, sufficient mechanical strength and density, high porosity and surface area. It showed high sulfur sorption capacity of 10.4wt% (ZnO utilization of 57%) at reaction temperatures of 500 and $650^{\circ}C$ for sulfidation and regeneration, respectively. However, the sulfur sorption capacity and ZnO utilization were significantly reduced and dimple shape appeared when the ZnO content decreased to 37.2 and 41.9wt%. Sulfur sorption capacity and regenerability were improved as reaction temperature increased within the experimental temperatures used in this work. The reaction temperature zones of $1500{\sim}550^{\circ}C$ and $650{\sim}700^{\circ}C$ are recommended for sulfidation and regeneration, respectively, to lead best reaction performances of the ZnO-based spray-dried sorbents developed in this work.

Ni/ZnO-based Adsorbents Supported on Al2O3, SiO2, TiO2, ZrO2: A Comparison for Desulfurization of Model Gasoline by Reactive Adsorption

  • Meng, Xuan;Huang, Huan;Weng, Huixin;Shi, Li
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.10
    • /
    • pp.3213-3217
    • /
    • 2012
  • Reactive adsorption desulfurization (RADS) experiments were conducted over a series of commercial metal oxide supports ($Al_2O_{3-}$, $SiO_{2-}$, $TiO_{2-}$ and $ZrO_{2-}$) supported Ni/ZnO adsorbents. The adsorbents were characterized by X-ray diffraction (XRD), temperature programmed reduction (TPR), and Fourier transform infrared spectroscopy (FTIR) in order to find out the influence of specific types of surface chemistry and structural characteristics on the sulfur adsorptive capacity. The desulfurization performance of all the studied adsorbents decreased in the following order: Ni/ZnO-$TiO_2$ > Ni/ZnO-$ZrO_2$ > Ni/ZnO-$SiO_2$ > Ni/ZnO-$Al_2O_3$. Ni/ZnO-$TiO_2$ shows the best performance and the three hour sulfur capacity can achieve 12.34 mg S/g adsorbent with a WHSV of $4h^{-1}$. Various characterization techniques suggest that weak interaction between active component and support component, high dispersion of NiO and ZnO, high reducibility and large total Lewis acidity of the adsorbents are important factors in achieving better RADS performance.