• Title/Summary/Keyword: High sensitivity

Search Result 4,958, Processing Time 0.037 seconds

T1-Staging for Urinary Bladder Cancer with the Stalk and Inchworm Signs with 3.0 Tesla MRI (3.0 테슬러 자기공명영상에서 Stalk 및 Inchworm Sign이 있는 방광암의 T1 병기 진단)

  • Da-hoon Kim;Byung Chul Kang;Jin Chung
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.5
    • /
    • pp.1194-1203
    • /
    • 2020
  • Purpose To evaluate the diagnostic utility of the stalk and the inchworm sign on preoperative MRI for detecting superficial bladder cancers, and to compare the diagnostic performance between the stalk and the inchworm sign. Materials and Methods We retrospectively reviewed 240 patients (505 tumors) who had undergone radical cystectomy. The tumors were classified as follows: superficial or invasive tumors indicated by the stalk or inchworm sign on 3.0 Tesla MRI. We evaluated the diagnostic accuracy of the stalk and inchworm signs, by comparing each finding with the postoperative pathologic T stage. We compared diagnostic performance between them statistically. Results The stalk and inchworm signs showed high specificity (93% and 91%, respectively), positive predictive values (89% and 90%, respectively), and acceptable accuracy (70% and 74%, respectively), but low sensitivity (54% and 61%, respectively) and negative predictive values (60% and 63%, respectively). There was no statistically significant difference between the two signs (p > 0.05). Conclusion Superficial bladder cancers could be differentiated from invasive tumors using the stalk or inchworm sign on MRI.

Feasibility of Single-Shot Whole Thoracic Time-Resolved MR Angiography to Evaluate Patients with Multiple Pulmonary Arteriovenous Malformations

  • Jihoon Hong;Sang Yub Lee;Jae-Kwang Lim;Jongmin Lee;Jongmin Park;Jung Guen Cha;Hui Joong Lee;Donghyeon Kim
    • Korean Journal of Radiology
    • /
    • v.23 no.8
    • /
    • pp.794-802
    • /
    • 2022
  • Objective: To evaluate the feasibility of single-shot whole thoracic time-resolved MR angiography (TR-MRA) to identify the feeding arteries of pulmonary arteriovenous malformations (PAVMs) and reperfusion of the lesion after embolization in patients with multiple PAVMs. Materials and Methods: Nine patients (8 females and 1 male; age range, 23-65 years) with a total of 62 PAVMs who underwent percutaneous embolization for multiple PAVMs and were subsequently followed up using TR-MRA and CT obtained within 6 months from each other were retrospectively reviewed. All imaging analyses were performed by two independent readers blinded to clinical information. The visibility of the feeding arteries on maximum intensity projection (MIP) reconstruction and multiplanar reconstruction (MPR) TR-MRA images was evaluated by comparing them to CT as a reference. The accuracy of TR-MRA for diagnosing reperfusion of the PAVM after embolization was assessed in a subgroup with angiographic confirmation. The reliability between the readers in interpreting the TR-MRA results was analyzed using kappa (κ) statistics. Results: Feeding arteries were visible on the original MIP images of TR-MRA in 82.3% (51/62) and 85.5% (53/62) of readers 1 and 2, respectively. Using the MPR, the rates increased to 93.5% (58/62) and 95.2% (59/62), respectively (κ = 0.760 and 0.792, respectively). Factors for invisibility were the course of feeding arteries in the anteroposterior plane, proximity to large enhancing vessels, adjacency to the chest wall, pulsation of the heart, and small feeding arteries. Thirty-seven PAVMs in five patients had angiographic confirmation of reperfusion status after embolization (32 occlusions and 5 reperfusions). TR-MRA showed 100% (5/5) sensitivity and 100% (32/32, including three cases in which the feeding arteries were not visible on TR-MRA) specificity for both readers. Conclusion: Single-shot whole thoracic TR-MRA with MPR showed good visibility of the feeding arteries of PAVMs and high accuracy in diagnosing reperfusion after embolization. Single-shot whole thoracic TR-MRA may be a feasible method for the follow-up of patients with multiple PAVMs.

Salivary Gland Uptake on 18F-FP-CIT PET as a New Biomarker in Patients With Parkinsonism

  • Seo Young Kang;Ji Young Yun;Yeon-Koo Kang;Byung Seok Moon;Hai-Jeon Yoon;Min Young Yoo;Bom Sahn Kim
    • Korean Journal of Radiology
    • /
    • v.24 no.7
    • /
    • pp.690-697
    • /
    • 2023
  • Objective: 18F-FP-CIT positron emission tomography (PET) is known for its high sensitivity and specificity for evaluating striatal dopamine transporter (DAT) binding. Recently, for the early diagnose of Parkinson's disease, many researchers focused on the diagnosis of synucleinopathy in organs involved in non-motor symptoms of Parkinson's disease. We investigated the feasibility of salivary gland uptake on 18F-FP-CIT PET as a new biomarker in patients with parkinsonism. Materials and Methods: A total of 219 participants with confirmed or presumed parkinsonism, including 54 clinically diagnosed idiopathic Parkinson's disease (IPD), 59 suspected and yet undiagnosed, and 106 with secondary parkinsonism, were enrolled. The standardized uptake value ratio (SUVR) of the salivary glands was measured on both early and delayed 18F-FP-CIT PET scans using the cerebellum as the reference region. Additionally, the delayed-to-early ratio (DE_ratio) of salivary gland was obtained. The results were compared between patients with different PET patterns. Results: The SUVR in early 18F-FP-CIT PET scan was significantly higher in patients with IPD pattern compared that in the non-dopaminergic degradation group (0.5 ± 0.19 vs. 0.6 ± 0.21, P < 0.001). Compared with the non-dopaminergic degradation group, the DE_ratio was significantly lower in patients with IPD (5.05 ± 1.7 vs. 4.0 ± 1.31, P < 0.001) or atypical parkinsonism patterns (5.05 ± 1.7 vs. 3.76 ± 0.96, P < 0.05). The DE_ratio was moderately and positively correlated with striatal DAT availability in both the whole striatum (r = 0.37, P < 0.001) and posterior putamen (r = 0.36, P < 0.001). Conclusion: Parkinsonism patients with an IPD pattern exhibited a significant increase in uptake on early 18F-FP-CIT PET and a decrease in the DE_ratio in the salivary gland. Our findings suggest that salivary gland uptake of dual-phase 18F-FP-CIT PET can provide diagnostic information on DAT availability in patients with Parkinson's disease.

Usefulness of Bone SPECT/CT for Predicting Avascular Necrosis of the Femoral Head in Children with Slipped Capital Femoral Epiphysis or Femoral Neck Fracture

  • Yoo Sung Song;Won Woo Lee;Moon Seok Park;Nak Tscheol Kim;Ki Hyuk Sung
    • Korean Journal of Radiology
    • /
    • v.23 no.2
    • /
    • pp.264-270
    • /
    • 2022
  • Objective: This study aimed to investigate the usefulness of bone single-positron emission tomography/computed tomography (SPECT/CT) of the hip in predicting the later occurrence of avascular necrosis (AVN) after slipped capital femoral epiphysis (SCFE) or femoral neck fracture in pediatric patients. The quantitative parameters of SPECT/CT useful in predicting AVN were identified. Materials and Methods: Twenty-one (male:female, 10:11) consecutive patients aged < 18 years (mean age ± standard deviation [SD], 11.0 ± 2.7 years) who underwent surgery for SCFE or femoral neck fracture and postoperative bone SPECT/CT were included. The maximum standardized uptake value (SUV), mean SUV, and minimum SUV of the femoral head were measured. The ratios of the maximum SUV, mean SUV, and minimum SUV of the affected femoral head to the contralateral side were determined. Patients were followed up for > 1 year after the surgery. The SPECT/CT parameters were compared between patients who developed AVN and those who did not. The accuracy of SPECT/CT parameters for predicting AVN was assessed. Results: Six patients developed AVN. There was a significant difference in the ratio of the mean SUV among patients who developed AVN (mean ± SD, 0.8 ± 0.3) and those who did not (1.1 ± 0.2, p = 0.018). However, there were no significant differences in the ratios of the maximum and minimum SUV between the groups (all p = 0.205). For the maximum, mean, and minimum SUVs, no significant differences were observed between the groups (p = 0.519, 0.733, and 0.470, respectively). The cutoff mean SUV ratio of 0.87 yielded a 66.7% sensitivity and 93.2% specificity for predicting AVN. Conclusion: Quantitative bone SPECT/CT is useful for evaluating femoral head viability in pediatric patients with SCFE or femoral neck fractures. Clinicians should consider the high possibility of later AVN development in patients with a decreased mean SUV ratio.

Myocardial Blood Flow Quantified by Low-Dose Dynamic CT Myocardial Perfusion Imaging Is Associated with Peak Troponin Level and Impaired Left Ventricle Function in Patients with ST-Elevated Myocardial Infarction

  • Jingwei Pan;Mingyuan Yuan;Mengmeng Yu;Yajie Gao;Chengxing Shen;Yining Wang;Bin Lu;Jiayin Zhang
    • Korean Journal of Radiology
    • /
    • v.20 no.5
    • /
    • pp.709-718
    • /
    • 2019
  • Objective: To investigate the association of myocardial blood flow (MBF) quantified by dynamic computed tomography (CT) myocardial perfusion imaging (MPI) with troponin level and left ventricle (LV) function in patients with ST-segment elevated myocardial infarction (STEMI). Materials and Methods: Thirty-five STEMI patients who successfully had undergone reperfusion treatment within 1 week of their infarction were consecutively enrolled. All patients were referred for dynamic CT-MPI. Serial high-sensitivity troponin T (hs-TnT) levels and left ventricular ejection fraction (LVEF) measured by echocardiography were recorded. Twenty-six patients with 427 segments were included for analysis. Various quantitative parameters derived from dynamic CT-MPI were analyzed to determine if there was a correlation between hs-TnT levels and LVEF on admission and again at the 6-month mark. Results: The mean radiation dose for dynamic CT-MPI was 3.2 ± 1.1 mSv. Infarcted territories had significantly lower MBF (30.5 ± 7.4 mL/min/100 mL versus 73.4 ± 8.1 mL/min/100 mL, p < 0.001) and myocardial blood volume (MBV) (2.8 ± 0.9 mL/100 mL versus 4.2 ± 1.1 mL/100 mL, p = 0.044) compared with those of reference territories. MBF showed the best correlation with the level of peak hs-TnT (r = -0.682, p < 0.001), and MBV showed a moderate correlation with the level of peak hs-TnT (r = -0.437, p = 0.026); however, the other parameters did not show any significant correlation with hs-TnT levels. As for the association with LV function, only MBF was significantly correlated with LVEF at the time of admission (r = 0.469, p = 0.016) and at 6 months (r = 0.585, p = 0.001). Conclusion: MBF quantified by dynamic CT-MPI is significantly inversely correlated with the level of peak hs-TnT. In addition, patients with lower MBF tended to have impaired LV function at the time of their admission and at 6 months.

Coronal Three-Dimensional Magnetic Resonance Imaging for Improving Diagnostic Accuracy for Posterior Ligamentous Complex Disruption In a Goat Spine Injury Model

  • Xuee Zhu;Jichen Wang;Dan Zhou;Chong Feng;Zhiwen Dong;Hanxiao Yu
    • Korean Journal of Radiology
    • /
    • v.20 no.4
    • /
    • pp.641-648
    • /
    • 2019
  • Objective: The purpose of this study was to investigate whether three-dimensional (3D) magnetic resonance imaging could improve diagnostic accuracy for suspected posterior ligamentous complex (PLC) disruption. Materials and Methods: We used 20 freshly harvested goat spine samples with 60 segments and intact surrounding soft tissue. The animals were aged 1-1.5 years and consisted of 8 males and 12 females, which were sexually mature but had not reached adult weights. We created a paraspinal contusion model by percutaneously injecting 10 mL saline into each side of the interspinous ligament (ISL). All segments underwent T2-weighted sagittal and coronal short inversion time inversion recovery (STIR) scans as well as coronal and sagittal 3D proton density-weighted spectrally selective inversion recovery (3D-PDW-SPIR) scans acquired at 1.5T. Following scanning, some ISLs were cut and then the segments were rescanned using the same magnetic resonance (MR) techniques. Two radiologists independently assessed the MR images, and the reliability of ISL tear interpretation was assessed using the kappa coefficient. The chi-square test was used to compare the diagnostic accuracy of images obtained using the different MR techniques. Results: The interobserver reliability for detecting ISL disruption was high for all imaging techniques (0.776-0.949). The sensitivity, specificity, and diagnostic accuracy of the coronal 3D-PDW-SPIR technique for detecting ISL tears were 100, 96.9, and 97.9%, respectively, which were significantly higher than those of the sagittal STIR (p = 0.000), coronal STIR (p = 0.000), and sagittal 3D-PDW-SPIR (p = 0.001) techniques. Conclusion: Compared to other MR methods, coronal 3D-PDW-SPIR provides a more accurate diagnosis of ISL disruption. Adding coronal 3D-PDW-SPIR to a routine MR protocol may help to identify PLC disruptions in cases with nearby contusion.

Interactions Between Genetic Risk Score and Healthy Plant Diet Index on Cardiometabolic Risk Factors Among Obese and Overweight Women

  • Fatemeh Gholami;Mahsa Samadi;Niloufar Rasaei;Mir Saeid Yekaninejad;Seyed Ali Keshavarz;Gholamali Javdan;Farideh Shiraseb;Niki Bahrampour;Khadijeh Mirzaei
    • Clinical Nutrition Research
    • /
    • v.12 no.3
    • /
    • pp.199-217
    • /
    • 2023
  • People with higher genetic predisposition to obesity are more susceptible to cardiovascular diseases (CVDs) and healthy plant-based foods may be associated with reduced risks of obesity and other metabolic markers. We investigated whether healthy plant-foods-rich dietary patterns might have inverse associations with cardiometabolic risk factors in participants at genetically elevated risk of obesity. For this cross-sectional study, 377 obese and overweight women were chosen from health centers in Tehran, Iran. We calculated a healthy plant-based diet index (h-PDI) in which healthy plant foods received positive scores, and unhealthy plant and animal foods received reversed scores. A genetic risk score (GRS) was developed based on 3 polymorphisms. The interaction between GRS and h-PDI on cardiometabolic traits was analyzed using a generalized linear model (GLM). We found significant interactions between GRS and h-PDI on body mass index (BMI) (p = 0.02), body fat mass (p = 0.04), and waist circumference (p = 0.056). There were significant gene-diet interactions for healthful plant-derived diets and BMI-GRS on high-sensitivity C-reactive protein (p = 0.03), aspartate aminotransferase (p = 0.04), alanine transaminase (p = 0.05), insulin (p = 0.04), and plasminogen activator inhibitor 1 (p = 0.002). Adherence to h-PDI was more strongly related to decreased levels of the aforementioned markers among participants in the second or top tertile of GRS than those with low GRS. These results highlight that following a plant-based dietary pattern considering genetics appears to be a protective factor against the risks of cardiometabolic abnormalities.

Research on the use of Therapeutic Linear accelerator Quality Control using EPR/alanine Dosimeter (EPR/알라닌 선량계를 이용한 치료용 선형가속기 정도관리 활용 연구)

  • Yoon-Ha Kim;Hyo-Jin Kim;Yeong-Rok Kang;Dong-Yeon Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.239-248
    • /
    • 2024
  • Radiation therapy uses high energy, which can have side effects on the human body. Therefore, it is important to ensure that the appropriate dose is set for irradiation and to have confidence in the radiation produced by the generator. The EPR/Alanine dosimetry system is characterized by water equivalence, dose response linearity, and low fading, which makes it useful for quality control of radiation therapy equipment. In this study, we compared the signal and dose response curves of EPR/Alanine dosimetry by mass of alanine using 6 MV energy of a LINAC. An alanine dosimeter and EPR spectrometer from Burker, and a LINAC from Elekta, were used. A dose response curve and a 1st order regression equation were constructed from the irradiated dose and the EPR signal from the alanine dosimeter. We compared the signal magnitude and dose response curve with mass and checked the confidence through the measurement uncertainty of the dose response curve. As a result, it was found that the magnitude of the EPR signal increased by about 1.3 times at 64.5 mg, and the sensitivity of the dose response curve increased as the mass increased. The measurement uncertainty was evaluated to be between 5.84 % and 8.93 %. Through this study, it is expected that the EPR/alanine dosimetry system can be applied to the quality assurance and quality control of a LINAC.

Physical habitat characteristics of freshwater crayfish Cambaroides similis (Koelbel, 1892) (Arthropoda, Decapoda) in South Korea

  • Jin-Young Kim;Yong Ju Kwon;Ye Ji Kim;Yeong-Deok Han;Jung Soo Han;Chae Hui An;Yong Su Park;Dongsoo Kong
    • Journal of Ecology and Environment
    • /
    • v.47 no.4
    • /
    • pp.200-210
    • /
    • 2023
  • Background: Cambaroides similis is an endangered candidate species living in the stream of South Korea. Freshwater crayfish is known to decline rapidly not only domestically, but also internationally. Its decline is projected to be further exacerbated due to climate change. Understanding physical characteristics of the habitat is crucial for the conservation of an organism. However, comprehensive data regarding the distribution and physical habitat characteristics of C. similis are currently unavailable in South Korea. Thus, the objective of this study was to ascertain preferred ranges for water depth, current velocity, and streambed substrate of C. similis using Weibull model. Results: In this study, C. similis was found at 59 sites across 12 regions in South Korea. Its optimal water depth preferences ranged from 11.9 cm to 30.1 cm. Its current velocity preferences ranged from 9.8 cm s-1 to 29.1 cm s-1. Its substrate preferences ranged from -5.1 𝜱m to -2.5 𝜱m. Median values of central tendency were determined as follows: water depth of 21.4 cm, current velocity of 21.2 cm s-1, and substrate of -4.1 𝜱m. Mean values of central tendency were determined as follows: water depth of 21.8 cm, current velocity of 22.0 cm s-1, and substrate of -4.4 𝜱m. Mode values of central tendency were determined as follows: water depth of 21.7 cm, current velocity of 20.1 cm s-1, and substrate of -3.7 𝜱m. Conclusions: Based on habitat suitability analysis, physical microhabitat characteristics of C. similis within a stream were identified as Run section with coarse particle substrate, low water depth, and slow current velocity. Due to high sensitivity of these habitats to environmental changes, prioritized selection and assessment of threats should be carried out as a primary step.

Preliminary Study on Effect of the Field Correlation Factor for Increasing of the Accuracy in a Direct Reading Instruments on Photoionization Detector for Total Volatile Organic Compounds (총휘발성유기화합물 측정 직독식장비 정확도 향상을 위한 현장보정계수 활용 연구)

  • Sungho Kim;Gwangyong Yi;Sujin Kim;Hae Dong Park
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.34 no.1
    • /
    • pp.67-76
    • /
    • 2024
  • Objectives: Direct reading instruments (DRIs) are widely used by industrial hygienists and other experts for preliminary survey and identifying source locations in many industrial fields. Photoionization detectors (PIDs), which are a form of hand-held portable DRIs, have been used for a variety of airborne vaporized chemicals, especially evaporated hydrocarbon solvents. The benefits of PIDs are high sensitivity between each chemical, competitive price, and portability. With the goal of increasing the accuracy of logged PID concentrations, previous studies have performed tests for the assessment of single chemical compounds, not mixtures. The purpose of this preliminary study was to measure mixtures with a PID and charcoal tube at the same time and compare the accuracy between them. Methods: A chamber test was implemented with different mixtures of hydrocarbon chemicals (acetone, isopropyl alcohol, toluene, m-xylene) and levels in the range of 14 to 864 ppm. Three PIDs and charcoal tubes were connected to the chamber and measured the chemical mixtures simultaneously. A comparison of accuracy and the PID group of concentrations with manufacture correction factor (M_CF) and field correction factor (F_CF) applied was performed. Results: The accuracy of the PID concentrations data-logged from the PID did not meet the accuracy criteria except for the mixture level B and C logged from PID No. 2, which was 18% of all tests for meeting accuracy criteria. The mean and standard deviation (SD) of concentration (ppm) of the charcoal tube followed by each mixtures' level were 10.37±0.26, 155.33±5.28, 300.80±11.65, and 774.93±22.65, respectively. When applying F_CF into the PID concentrations, the accuracy increased by nearly 82%. However, in the case of M_CF, none met the accuracy criterion. Between the PID there were differences of logged concentrations. Conclusions: In this preliminary study, the concentration of a logged PID with F_CF applied was a better way to increase accuracy compared to applying M_CF. We suggest that additional research is necessary to consider environmental factors such as temperature and humidity.