• Title/Summary/Keyword: High sensitivity

Search Result 4,954, Processing Time 0.032 seconds

Salt Intake Behavior and Blood Pressure: the effect of taste sensitivity and preference (소금 섭취 행태와 혈압: 맛에 대한 민감도와 선호도의 영향)

  • Kim, Jin-Hee;Choi, Man-Kyu
    • Korean Journal of Human Ecology
    • /
    • v.16 no.4
    • /
    • pp.837-848
    • /
    • 2007
  • The literature suggested that a small reduction in overall blood pressure can have a large effect on overall prevalence of hypertension, and therefore, the affect of taste preferences of the population on salt intake should be considered for long-term blood pressure intervention programs. The purpose of this study is to investigate the influence of salt taste preference and salt taste sensitivity on salt intake behavior as risk factors for high blood pressure. We collected information on blood pressure, diet and lifestyle behaviors, salt taste preference and salt taste sensitivity from 540 respondents from Suseo-dong, Seoul. Salt taste sensitivity was assessed by administering a 1% NaCl solution to the subject's tongue and measuring the perceived intensity on 10 level scale. Salt intake behavior was classified into 3 categories: frequency of high-sodium foods, practice of salt-reducing behavior and frequency of vegetable and fruit intake. Salt taste preference showed a significant relation to the subjects' blood pressure, i.e. subjects with a higher salt preference had higher blood pressure. Salt taste sensitivity did not show a significant relation to blood pressure. However, there was a positive correlation between salt taste preference and salt taste sensitivity. Among the 3 indicators used to measure salt intake behavior, the practice of salt-reducing behavior remained significantly correlated to blood pressure. Moreover, salt-reducing behavior and salt taste preference showed a significant correlation, i.e. people who do not like salty foods tend to practice more salt-reducing behavior, leading to reduced levels in blood pressure. In a population, a small reduction in overall blood pressure can have large effects in overall prevalence of hypertension, in contrast to clinical studies where achievement of an individual's normal blood pressure is emphasized. Therefore, taste preference of the population should be considered for long-term blood pressure intervention programs.

The Moderating Effects of School Violence Victimization Experiences in the Relationships between Airmen's Rejection Sensitivity, Depression, and Anxiety (공군장병의 거부민감성과 우울 및 불안의 관계에서 학교폭력 피해 경험의 조절효과)

  • Park, Won-Ju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.353-361
    • /
    • 2018
  • This study aimed to examine the effects of rejection sensitivity on depression and anxiety, and the moderating effects of school violence victimization experiences on the relationships between rejection sensitivity and both anxiety and depression. Based on the results, we suggested a method of screening soldiers at high risk of depression and anxiety and interventions for their psychological adaptation. The data about anxiety, depression, rejection sensitivity, and school violence victimization experiences was collected from 126 airmen in S city, South Korea. To test the moderation effects, multiple regression analyses were conducted in which the rejection sensitivity, anxiety, school violence victimization experiences and their interaction terms were hierarchically entered. The moderation of school violence victimization experiences was found in the relationship between rejection sensitivity and school violence victimization experiences. The specific interaction patterns in each of these significant interaction effects were examined. Finally, the importance of school violence victimization experiences as a high-risk factor in army life and the clinical implication of these findings were discussed.

Diagnostic Accordance Rate and Accuracy Between Cytological and Histological Test in Lung Disease (폐질환에 있어 세포검사와 조직검사의 진단 일치율 및 정확도에 대한 조사 연구)

  • Kim, Sung-Chul;Ro, Joung-Whan;Kim, Tai-Jeon
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.41 no.4
    • /
    • pp.189-195
    • /
    • 2009
  • Lung cancer is a type of cancer with high mortality; its 5-year survival rate is at a low 14%. Related cytological tests include sputum, bronchial brushing, bronchial washing and fine needle aspiration cytology test etc. From the test specimens in which sputum, bronchial brushing, bronchial washing, and fine needle aspiration cytology were performed, the sensitivity, specificity and accuracy between cytology test and histology test. In the sputum test, sensitivity was 27.71% and specificity was 98.02%, and the bronchial brushing test showed sensitivity of 93.33% and a specificity of 91.3%. The bronchial washing test was a sensitivity of 53.7% and its specificity was 98.9%, and the fine needle aspiration cytology test showed sensitivity and specificity were 88.46% and 72.97%, respectively. In the specimens diagnosed as normal at the sputum test, malignant diagnosis was found in 21 specimens of bronchial brushing, 30 cases of bronchial washings and 37 cases of fine needle aspiration cytology specimens. In the specimens diagnosed as normal at the bronchial washing test, malignant diagnosis was found in 5 specimens of sputum, 7 specimens of bronchial brushin and 1 cases of fine needle aspiration cytology. One specimens found to be normal in fine needle aspiration cytology turned out to maligant in sputum test. The result of this research shows that, in diagnosis lung cancer, a test method of high sensitivity and specificity should be pursued. However, depending on the location and malignancy of the illness, diagnosis may not be obtained in some cases. Therefore, we conclude that the cytological tests performed for lung cancer testing such as sputum, bronchial brushing, bronchial washing, and fine needle aspiration cytology should be carried out in a mutually complementary manner.

  • PDF

Variation in seedling growth inhibition due to Maleic Hydrazide treatment of rice(Oryza sativa) and ragi(Eleusine coracana) genotypes and its relationship with yield and adaptability

  • Das, Swarnalata;Sinha, Susil Kumar;Misra, Rama Chandra
    • Journal of Crop Science and Biotechnology
    • /
    • v.11 no.3
    • /
    • pp.215-222
    • /
    • 2008
  • Multilocation trials on 36 rice(Oryza sativa) genotypes of 3 different maturity groups were conducted at four different locations of Orissa for 3 years and 30 ragi(Eleusine coracana) genotypes of 2 different maturity groups were evaluated in three environmental conditions for 3 years. Grain yield data were subjected to stability analysis following linear regression model to estimate adaptability and stability parameters, i.e. b, and $S^2d$ Stability of performance of genotypes was also estimated by two other stability parameters viz., ecovalence W and AMMI stability value ASV. The rice and ragi genotypes of different duration groups showed wide variation in their mean yield, b, $S^2d$, W and ASV parameters. Seeds of the 36 rice and 30 ragi genotypes were treated with 500 and 100 ppm aqueous solution of maleic hydrazide(MH) for 24 hours, respectively to study MH-sensitivity. Sensitivity of genotypes to MH treatment was estimated in terms of seedling growth inhibition index(SGI). The rice and ragi genotypes showed wide differences in their MH-sensitivity in terms of SGI. Relationship of MH-sensitivity of genotypes with their yielding ability, adaptability and stability of performance was tested by contingency $x^2$ test. Low sensitivity of rice and ragi genotypes to MH in terms of SGI appeared to be good indicators of high yielding ability of genotypes. Also, low and high MH-sensitivity of genotypes would be a good indicator of better adaptability to rich and poor environments, respectively, in ragi but not in rice. Low MH-sensitivity of genotypes could be the good indicator of stability of yield performance in rice but not in ragi.

  • PDF

Quantitative Evaluation of Image Quality using Automatic Exposure Control & Sensitivity in the Digital Chest Image (디지털 흉부영상에서 자동노출제어 및 감도변화를 이용한 영상품질의 정량적인 평가)

  • Lee, Jin-Soo;Ko, Seong-Jin;Kang, Se-Sik;Kim, Jung-Hoon;Kim, Dong-Hyun;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.8
    • /
    • pp.275-283
    • /
    • 2013
  • The patient radiation dose is different depending on selection of Ion chamber when taking Chest PA which using AEC. In this paper, we studied acquiring the best diagnostic images according to selection of Ion chamber on AEC mode as well as minimizing patient radiation dose. Experimental methods were selection of Ion chamber and change of sensitivity under the same conditions as Chest PA projection. At AEC mode, two upper ion chambers sensors and one lower ion chamber sensor were divided into 7 cases according to selection of on/off. after measuring five times respectively, we obtained average value and calculated exposure dose. Image assessment was done with measured Modulation Transfer Function, Peak Signal to Noise Ratio, Root Mean Square, Signal to Noise Ratio, Contrast to Noise Ratio, Mean to Standard deviation Ratio respectively. In exposure assessment results, selection of two upper chambers was the lowest. In resolution assessment results, image of two upper chambers had the second high spatial frequency at sensitivity at 625(High) was 1.343 lp/mm. RMS value of image selecting two upper chambers was low secondly. SNR, CNR, MSR were the high value secondly. As the sensitivity was increased, radiation dose was decreased but better image could be obtained on image quality. In order to obtain the best medical images while minimizing the dose, usage of two upper ion chambers is considered to be clinically useful at sensitivity 625(High).

A Relationship between Kinetic Visual Acuity and Contrast Sensitivity (동적시력과 대비감도의 상관관계)

  • Shim, Moon-Sik;Kang, Hye-Sook;Kim, Sang-Hyun;Shim, Hyun-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.225-229
    • /
    • 2014
  • Purpose: The study was to analyze the correlation between kinetic visual acuity (KVA), visual acuity(static visual angle, SVA) and contrast sensitivity. Methods: Ninety-nine undergraduate students studying Ophthalmic Optics were fully corrected by the Topcon CV-3000 Phoropter. The contrast sensitivity was measured for the participants under the photopic condition ($100cd/m^2$) with Vector Vision CSV-1000E at 2.5 meter, while KVA was measured with KOWA AS-4A. The participants were classified into three groups L, M and H depending on the KVA (0.1~0.3, 0.31~0.6 and greater than 0.61, respectively) and were analyzed whether there was the correlation between the contrast sensitivity, visual acuity and refractive error. Results: The KVA was correlated with the contrast sensitivity for 3 cpd (r=0.26), for 6 cpd (r=0.48), for 12 cpd (r=0.38) and 18 cpd (r=0.47). Except for the low frequency of 3 cpd, they all were higher than the one of the SVA and the KVA (r = -0.37). The contrast sensitivity for 3, 6, 12 and 18 cpd was 59.41, 92.22, 38.41 and 14.39 in the group L, respectively. The contrast sensitivity in the group M was 66.03, 108.78, 53.51 and 19.20 and the one in the group H was 70.90, 146.10, 62.90 and 25.33 for 3, 6, 12 and 18 cpd, respectively. Conclusions: The correlation of the contrast sensitivity and the KVA was higher than the one of the contrast sensitivity and the SVA. It can be assumed that the contrast sensitivity will be high if the KVA is high, except for the case for low spatial frequency.

High Sensitivity 3-axis Actuator for Slim Optical Disc Drive (슬림광디스크드라이브를 위한 고감도 3축구동 액추에어터)

  • Cheong, Young-Min;Lee, Jin-Won;Kim, Kwang
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.1000-1003
    • /
    • 2002
  • For high density optical storage, there should be a high NA objective lens and a shorter wavelength laser diode. To secure the disc tilt margin related to the coma aberration, moreover, it's difficult to apply the tilt compensation mechanism into the portable PC. In this paper, we proposed the 3-axis asymmetry pickup actuator with high efficiency symmetric magnetic circuit, which consisted of the top cover type inner yoke for high magnetic flux density, the coil stack unit for the 3-axis independent operation and vertically polarized magnets. This newly suggested actuator features DVD-RAM recording, we achieved the high focus & track AC sensitivity and the greatly stabilized system.

  • PDF

Development of the High Temperature Silicon Pressure Sensor (고온용 실리콘 압력센서 개발)

  • Kim, Mi-Mook;Nam, Tae-Chul;Lee, Young-Tae
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.175-181
    • /
    • 2004
  • A pressure sensor for high temperature was fabricated by using a SDB(Silicon-Direct-Bonding) wafer with a Si/$SiO_{2}$/ Si structure. High pressure sensitivity was shown from the sensor using a single crystal silicon of the first layer as a piezoresistive layer. It also was made feasible to use under the high temperature as of over $120^{\circ}C$, which is generally known as the critical temperature for the general silicon sensor, by isolating the piezoresistive layer dielectrically and thermally from the silicon substrate with a silicon dioxide layer of the second layer. The pressure sensor fabricated in this research showed very high sensitivity as of $183.6{\mu}V/V{\cdot}kPa$, and its characteristics also showed an excellent linearity with low hysteresis. This sensor was usable up to the high temperature range of $300^{\circ}C$.

CMOS binary image sensor with high-sensitivity metal-oxide semiconductor field-effect transistor-type photodetector for high-speed imaging

  • Jang, Juneyoung;Heo, Wonbin;Kong, Jaesung;Kim, Young-Mo;Shin, Jang-Kyoo
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.5
    • /
    • pp.295-299
    • /
    • 2021
  • In this study, we present a complementary metal-oxide-semiconductor (CMOS) binary image sensor. It can shoot an object rotating at a high-speed by using a gate/body-tied (GBT) p-channel metal-oxide-semiconductor field-effect transistor (PMOSFET)-type photodetector. The GBT PMOSFET-type photodetector amplifies the photocurrent generated by light. Therefore, it is more sensitive than a standard N+/P-substrate photodetector. A binary operation is installed in a GBT PMOSFET-type photodetector with high-sensitivity characteristics, and the high-speed operation is verified by the output image. The binary operations circuit comprise a comparator and memory of 1- bit. Thus, the binary CMOS image sensor does not require an additional analog-to-digital converter. The binary CMOS image sensor is manufactured using a standard CMOS process, and its high- speed operation is verified experimentally.

A gene responsible for ozone sensitivity (ozrB) in chromosome of escherichia coli B. MQ 1844 (E. coli B. MQ1844 균주의 오존감수성 유전자의 특성)

  • ;Hamelin C.
    • Korean Journal of Microbiology
    • /
    • v.25 no.2
    • /
    • pp.103-109
    • /
    • 1987
  • An ozone-sensitive mutant of Escherichia coli strain B, MQ 1844 is described. Its properties, including high sensitivity to ozone and radiation, inducible filamentation, extensive DNA degradation and impaired DNA synthesis following ozonation, are attributable to a mutation in ozrB, a gene which is cotransducible with malB. Based on differences in phenotypic expression as well as on the particular location of this gene on the bacterial chromosome, ozrB appears as distinct from the other ozone-or radiation-sensitivity genes previously described.

  • PDF