BEEF MEAT TRACEABILITY. CAN NIRS COULD HELP\ulcorner
-
- 한국근적외분광분석학회:학술대회논문집
- /
- 한국근적외분광분석학회 2001년도 NIR-2001
- /
- pp.1246-1246
- /
- 2001
The quality of meat is highly variable in many properties. This variability originates from both animal production and meat processing. At the pre-slaughter stage, animal factors such as breed, sex, age contribute to this variability. Environmental factors include feeding, rearing, transport and conditions just before slaughter (Hildrum et al., 1995). Meat can be presented in a variety of forms, each offering different opportunities for adulteration and contamination. This has imposed great pressure on the food manufacturing industry to guarantee the safety of meat. Tissue and muscle speciation of flesh foods, as well as speciation of animal derived by-products fed to all classes of domestic animals, are now perhaps the most important uncertainty which the food industry must resolve to allay consumer concern. Recently, there is a demand for rapid and low cost methods of direct quality measurements in both food and food ingredients (including high performance liquid chromatography (HPLC), thin layer chromatography (TLC), enzymatic and inmunological tests (e.g. ELISA test) and physical tests) to establish their authenticity and hence guarantee the quality of products manufactured for consumers (Holland et al., 1998). The use of Near Infrared Reflectance Spectroscopy (NIRS) for the rapid, precise and non-destructive analysis of a wide range of organic materials has been comprehensively documented (Osborne et at., 1993). Most of the established methods have involved the development of NIRS calibrations for the quantitative prediction of composition in meat (Ben-Gera and Norris, 1968; Lanza, 1983; Clark and Short, 1994). This was a rational strategy to pursue during the initial stages of its application, given the type of equipment available, the state of development of the emerging discipline of chemometrics and the overwhelming commercial interest in solving such problems (Downey, 1994). One of the advantages of NIRS technology is not only to assess chemical structures through the analysis of the molecular bonds in the near infrared spectrum, but also to build an optical model characteristic of the sample which behaves like the “finger print” of the sample. This opens the possibility of using spectra to determine complex attributes of organic structures, which are related to molecular chromophores, organoleptic scores and sensory characteristics (Hildrum et al., 1994, 1995; Park et al., 1998). In addition, the application of statistical packages like principal component or discriminant analysis provides the possibility to understand the optical properties of the sample and make a classification without the chemical information. The objectives of this present work were: (1) to examine two methods of sample presentation to the instrument (intact and minced) and (2) to explore the use of principal component analysis (PCA) and Soft Independent Modelling of class Analogy (SIMCA) to classify muscles by quality attributes. Seventy-eight (n: 78) beef muscles (m. longissimus dorsi) from Hereford breed of cattle were used. The samples were scanned in a NIRS monochromator instrument (NIR Systems 6500, Silver Spring, MD, USA) in reflectance mode (log 1/R). Both intact and minced presentation to the instrument were explored. Qualitative analysis of optical information through PCA and SIMCA analysis showed differences in muscles resulting from two different feeding systems.
기존의 공정방식에 비해 효율성이나 환경적 면에서 많은 장점을 가진 플라즈마 공정은 반도체 제작에서 널리 사용되고 있다. Plasma Sheath란 플라즈마 bulk와 그 것을 둘러싸고 있는 챔버 벽면과 전극 사이에서 관찰되는 어두운 영역으로 양이온과 전자의 이동속도 차이로 인해 발생한다. Plasma Sheath Monitoring Sensor (PSMS)는 플라즈마와 전극 사이의 전압(Voltage) 차이와 전극에 걸리는 RF power 등을 실시간으로 측정하는 센서로서 플라즈마 챔버 내에서 플라즈마의 상태와 매우 상관도가 높을 것으로 기대된다. 본 연구에서는 PSMS 데이터를 활용하여 플라즈마 챔버 내의 질소이온의 상태를 예측하는 모형을 딥러닝 기계학습 기법을 이용하여 구축하였다. 연구에 사용된 데이터는 파워와 압력을 달리 셋팅한 실험에서 측정된 PSMS 데이터를 학습데이터로 활용하고 플라즈마 bulk와 Si substrate에서 측정된 질소 이온의 비율, 플럭스, 밀도를 레이블로 활용하였다. 본 연구의 결과는 향후 플라즈마 공정의 최적화 및 실시간 정밀제어를 위한 인공지능 기술의 기초가 될 것으로 기대된다.
본 총설은 부화 후 1주일간 급여되는 초이사료 적용의 필요성 및 배합설계방안을 제시하여 육계생산성을 증대하는 방안을 살펴보고자 한다. 육계는 지난 수년 간 괄목할 만한 증체 속도 증가, 출하일령 단축 그리고 사료효율 향상을 보 여줬다. 이는 육종 개량, 사육 환경 개선, 과학적인 사양관리기법 적용 및 적정 영양공급 등의 결과이며, 한국의 경우 다른 나라에 비해 육계사육기간이 매우 짧아, 부화 후 약 31일령이면 출하가 이루어지고 있는 실정이다. 따라서 육계초기 1주일간은 전체 사육기간의 20% 이상을 차지할 뿐만 아니라, 초기성장이 출하체중과 일령 그리고 사료효율에 지대한 영향을 미치고 있으므로 초기 1주일간의 사료공급을 통한 생산성 향상이 매우 중요하다. 생후 7일령까지의 어린 병아리는 소화기관 미발달과 효소의 분비 및 활력 부족으로 사료 내 영양소의 소화 흡수 및 이용률이 낮은 편임을 고려하여, 초이사료의 급여를 위한 영양적 접근 방법으로는 크게 3가지로 나눌 수 있다. 첫 번째로는 단순히 영양수준을 올리기보다는 양질의 원료 사용, 특히 단백질과 탄수화물 이용률 증진을 위 한 선택적인 원료 사용 및 원료의 가공처리가 필요하다. 에너지 공급의 경우, 에너지 수준 못지않게 에너지 공급원이 중요한데, 특히 불포화지방산공급원인 식물성이 기름 첨가를 권장한다. 영양소 공급의 경우, 단백질 함량을 증가시키기보다는 이상적 아미노산 비율에 따른 필수아미노산 공급이 중요하다. 필요 시 효소제를 비롯한 항생제 등의 대체 물질 첨가를 통해 항병력이나 소화흡수율을 향상시키는 방안을 고려해 볼 수 있다. 아울러 기타 제한 아미노산의 충족에 대한 연구와 부화 후 7일간 사료 내 전해질 균형의 영향에 대한 연구가 앞으로 필요하다.
Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70
본 연구에서는 다양한 가공공정 처리를 한 더덕 추출물의 총 폴리페놀 및 플라보노이드 함량과 항산화활성 변화를 비교하였다. 총 폴리페놀 및 플라보노이드 함량은 S5FDW에서 73.9 mg GAE/g과 50.9 mg QUE/g으로 가장 높게 나타났으며, DE에서는 15.7 mg GAE/g과 14.7 mg QUE/g으로 가장 낮았다. DPPH와 ABTS radical 소거능은 농도 의존적인 경향을 나타냈으며, 1.0 mg/mL 농도에서
krill을 식용화하기 위한 한 방법으로서 paste상 및 분말상의 krill soluble을 가공하고 제품의 구성아미노산 및 유리아미노 리의 조성을 검토하였다. 생동결 krill, 자가소화 및
연소시설에서는 화석연료에 포함된 질소와 황이 산소와 반응하여 대기 오염물질인 질소산화물(NOX)과 황산화물(SOX)을 발생시킨다. 인체에 유해하고 환경 오염을 야기하는 NOX, SOX를 저감하기 위해 전세계적으로 환경규제를 시행 중이며, 규제를 충족하기 위해 다양한 기술들을 적용하고 있다. 상용화된 NOX 및 SOX 저감방식들로 SCR (selective catalytic reduction), SNCR (selective non-catalytic reduction), WFGD (wet flue gas desulfurization) 등이 있으나 이 방식들의 단점들 때문에 NOX, SOX를 동시제거하는 연구가 근래 많이 수행되고 있다. 그러나 NOX, SOX 동시 제거 방식에서도 산화제 및 흡수제로 인한 폐수 발생에 대한 문제점, 특정 산화제를 활성화 하기 위한 촉매 및 전기분해 사용에 따른 비용 발생, 마지막으로 기체 산화제들 자체 유해성의 문제점을 가지고 있다. 따라서 본 연구에서는 NOX, SOX 동시처리 방식의 단점들을 보완하고자 고압분산기에서 생성된 마이크로버블과 환원제를 이용하여 비용절감 및 폐수처리 시 환경부하저감 가능성을 확인해 하고자 하였다. 분산기가 마이크로버블을 생성하는 것을 이미지 프로세싱과 ESR (electron spin resonance) 분석을 통해 확인하였으며, 마이크로버블만을 이용하여 온도에 따른 NOX, SOX 제거율 성능 테스트도 진행하였다. 뿐만 아니라 폐수를 저감하기 위해 환원제와 마이크로버블을 이용하여 습식으로 NOX 제거율 약 75%, SOX 제거율 99%를 달성하였다. 본 마이크로버블 시스템에 산화제를 함께 투여할 경우 NOX, SOX제거율 모두 99%이상을 달성 하였다. 이러한 연구 결과를 토대로 습식산화제거방식을 적용하는 시설의 단점이었던 비용 및 환경 문제를 해결함에 기여할 수 있을 것으로 기대 된다.
미래모빌리티의 발전 기대에 따라 에너지 소비 절감에 대한 수요가 증가하고 있다. 경량구조용소재는 온실가스 배출 감소 및 에너지 효율 향상을 위한 방안으로 알려져 있다. 특히, 섬유강화복합재료(FRP, fiber reinforced polymer composite)는 뛰어난 기계적 특성 및 낮은 무게로 인해 기존 합금을 대체할 수 있는 소재로 주목받는다. 본 논문에서는, 탄소섬유강화복합재료(CFRP, carbon FRP) 및 자기강화복합재료(SRC, self-reinforced composite)의 산업 적용 및 연구 동향을 강화재, 고분자 매트릭스 및 공정에 기반하여 검토하였다. 항공분야에서 주로 활용되는 에폭시 수지 기반 오토클레이브 공법의 높은 공정단가 및 긴 제조시간을 극복하기 위하여, 속경화성 에폭시 수지를 이용한 고압수지이송성형 공정으로 CFRP가 적용된 전기자동차의 양산을 보고하였다. 또한, 탄소섬유복합재료의 재활용 이슈를 해결하기 위한 열가소성 수지 기반 CFRP 및 계면 향상 방안들이 재료 및 공정 측면에서 검토되었다. FRP의 우수한 기계적 특성을 유도하는 주요한 요인으로 알려진 완벽한 매트릭스-강화재 계면을 형성하기 위하여, 고분자 섬유에 동일한 매트릭스를 함침시킨 SRC에 대한 연구들이 보고되고 있다. 다양한 열가소성 고분자에 기초한 SRC의 물리적 및 기계적 특성들을 고분자 배향 및 복합재료 구조 측면에서 검토하였다. 또한, 고연 신 폴리프로필렌 섬유 기반 SRC의 공정창 확장을 위한 공중합체 매트릭스 전략이 논의되었다. 경량구조용소재의 CFRP 및 SRC 적용은 미래모빌리티의 에너지 효율 향상에 대한 잠재적인 선택을 제공할 수 있다.
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70