• Title/Summary/Keyword: High pressure pipe

Search Result 365, Processing Time 0.03 seconds

Development of optimum pump operation technique for the damage rate reduction of water distribution system (상수도관망의 피해율 저감을 위한 가압장 최적운영기법 개발)

  • Kwon, Hyuk Jae
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.5
    • /
    • pp.373-380
    • /
    • 2019
  • In this study, the optimum pump operation technique is suggested to decrease the damage rate of water distribution system. Pump operation system was developed to achieve the effective pump operation. Pressure sensors which can communicate with pumps are installed at the end of water distribution system. Pump operation system can control the pressure of water pump according to data sent from the pressure sensors. Therefore, water distribution system can reduce the pressure and maintain enough pressure which can supply the demand of water users. For proving effectiveness of new system, reliability model was introduced to compare the results of damage rates between the maintaining high pressure and selective pressure in water pump. Unsteady analysis was conducted with several scenarios. And the results were used to calculate the probability of pipe breakage. From the results, it was found that new pump operation system can reduce the energy usage and probability of pipe breakage by applying to pumps.

The Research and Application of Protective Coating for PCCP

  • Lin, Zhu;Xu, Cuizhu;Zhang, Li;Fan, Yunpeng;Zhang, Qibin
    • Corrosion Science and Technology
    • /
    • v.7 no.5
    • /
    • pp.265-268
    • /
    • 2008
  • Prestressed Concrete Cylinder Pipe(PCCP) had became one of the dominating kinds of pipes substituting for steel pipes because of its unique feature (high intensity, high pressure and high leakproofness). PCCP was produced firstly by Bonna company in France. By the end of 20th century, there were over 19000 km of this product installed in America. PCCP was introduced from Ameron company by Shandong Eletric Power Pipeline Engineering Company in 1988. As the statistical data in 2002, 700 km of PCCP had been applied in China, and the application trended towards rapid increase.Since prestressing wire would be corroded in environment, Several accidents due to the breakdown of pipe had happened. Consequently the external wall of pipe should be covered with protective coatings. There was a lack of technical study in corrosion and control of PCCP, because PCCP had been applied for a short time in China. in order to ensure the service life of PCCP, we have developed a kind of protective coating for concrete pipe, which had high intensity and anti-corrosive property with convenient applicability. The physical and chemical properties, painting technology and field application of this coating was introduced in the paper, at the same time, the future of external protective coating for PCCP was looked into.

Buckling of Laminated Cylindrical Composite Structures Subjected to Ply Angle Change Under External Uniform Pressure (등분포 하중 작용시 적층각 변화에 따른 원통형 적층구조물의 좌굴)

  • 나태수;염응준;한택희;강영종
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.04a
    • /
    • pp.349-355
    • /
    • 2004
  • The material such as steel or concrete has used to civil structures such as drainage pipes , but many problems such as corrosion in using steel and concrete pipes have happened. So, Necessity of developing new materials with high strength and anti-corrosion has been topic recently. One of this topics is study about ERP pipe. The strength of orthotropic FRP tends to be higher than it of isotropic FRP, the buckling problems can be significant in materials with high strength. thus, the study about bucking of orthotropic FRP-pipe is needed. In this study, buckling analysis of laminated cylindrical composite structures subjected In ply angle change under external uniform pressure was performed.

  • PDF

A Study on the Pumping Characteristics according to Pumping Method and Rheology Characteristics of Concrete (콘크리트의 레올로지 특성 및 펌핑조건에 따른 펌프압송특성에 관한 연구)

  • Kwon, Dae-Hun;Jung, Woong-Taek;Kim, Hyung-Rae;Jo, Ho-Kyoo;Jeon, Jun-Young;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05a
    • /
    • pp.99-101
    • /
    • 2011
  • In order to have pumping technology for high speed construction of tall building, study for quantitative evaluation of flow characteristics and pumpability should be conducted. So, this study evaluate the characteristics among the inner pipe pressure, fresh concrete properties and separated mortar through the continuous pumping test. Then it consider of relations between rheological properties and pumpability. In the result of test, it found that there are high interrelationship between the rheological characteristics which represented plastic viscosity and pressure lose by pipe length.

  • PDF

A Study on the Contact Characteristics of Metal Ring Joint Gaskets

  • Lee, Min-Young;Kim, Byung-Tak
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.3
    • /
    • pp.25-31
    • /
    • 2016
  • Gaskets are usually used for the sealing of flange joints. The joint is usually composed of two flanges, a ring gasket and clamping bolts. The metal ring gasket is suitable for pipe flanges, pumps and valve joints in high temperature and high pressure environments. A very high surface stress is developed between a ring type joint gasket and the flange groove when the ring type joint is bolted up in a flange. The dimensions of flanges and ring joint gaskets for the pipe sizes that are in common use are specified in the ANSI codes. However, sometimes it is necessary to make a new design for the flange joint which is not specified in the codes, as the equipment is getting larger and larger in size. This paper presents the contact behavior of Class 600 ring joint gaskets with oval and octagonal cross sections. Five different sizes of gaskets are employed in the analysis, and one of them is newly designed on the basis of analysis results obtained from existing models. Three load steps are used to find the stress, stain and contact pressure etc., and to compare the contact characteristics among the models due to the bolt clamping force and the working surface pressure. ANSYS Workbench version15 is used to conduct the finite element analysis.

Experience in Visual Testing of the Main Feed Water Piping Weld for Hanul Unit 3 (한울 3호기 주급수 배관 용접부 육안검사 경험)

  • Yoon, Byung Sik;Moon, Gyoon Young;Kim, Yong Sik
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.11 no.1
    • /
    • pp.74-78
    • /
    • 2015
  • Nuclear power plant steam generator that is one of the main component has several thousands of thin tubes. And the steam generator tube is subject to damage because of the severe operation conditions such as the high temperature and pressure. Therefore periodic inspections are conducted to ensure the integrity of steam generator component. Hanul unit 3 also has been inspected in accordance with in-service inspection program and is scheduled to be replaced for exceeding the plugging rate which was recommended by manufacturer. During the steam generator replacement activity, we found several clustered porosity on inner surface of main feed water pipe. Additionally crack-like indications were found at weld interface between base material and weld of main feed water pipe. This paper describes the field experience and visual testing results for inner surface of main feed water pipes. The destructive test result had shown that these indications were porosities which were caused by manufacturing process not by operation service.

Analysis on Fitting Characteristics of a Metal-Sealing Pipe of the Hydrogen Fuel Tank for FCEV (FCEV용 고압연료탱크 메탈씰링 파이프의 체결특성 해석)

  • Lee, J.M.;Jeong, J.H.;Chon, M.S.;Lee, H.W.
    • Transactions of Materials Processing
    • /
    • v.27 no.1
    • /
    • pp.54-59
    • /
    • 2018
  • In connecting parts of a hydrogen fuel cell vehicle, since the rubber ring is permeable to hydrogen, it is necessary to use a metal sealing structure which ensures leakage stability. Finite element analysis was performed to verify the fitting characteristics of the metal sealing structure, which is used to connect the pipe to a high pressure hydrogen FCEV tank. Deformation shape, contact distance and axial load were compared experimentally and these values were in agreement with each other. In the contact surface, between the pipe and the fitting body, the stress at the edge of the contact surface was higher than the center point, which was considered to be a good characteristic in view point of the leakage. The location of the contact points has almost no change in the upper part of the fitting, but that of the lower parts move downward as the fastening amount increases. The contact pressure at the lower part is maintained at the same constant level.

Bending ratcheting behavior of pressurized straight Z2CND18.12N stainless steel pipe

  • Wang, Lei;Chen, Gang;Zhu, Jianbei;Sun, Xiuhu;Mei, Yunhui;Ling, Xiang;Chen, Xu
    • Structural Engineering and Mechanics
    • /
    • v.52 no.6
    • /
    • pp.1135-1156
    • /
    • 2014
  • The ratcheting effect greatly challenges the design of piping components. With the assistance of the quasi-three point bending apparatus, ratcheting and the ratcheting boundary of pressurized straight Z2CND18.12N stainless steel pipe under bending loading and vertical displacement control were studied experimentally. The characteristics of progressive inelastic deformation in axial and hoop directions of the Z2CND18.12N stainless steel pipes were investigated. The experiment results show that the ratcheting strain occurs mainly in the hoop direction while there is less ratcheting strain in the axial direction. The characteristics of the bending ratcheting behavior of the pressure pipes were derived and compared under load control and displacement control, respectively. The results show that the cyclic bending loading and the internal pressure affect the ratcheting behavior of the pressurized straight pipe significantly under load control. In the meantime, the ratcheting characteristics are also highly associated with the cyclic displacement and the internal pressure under displacement control. All these factors affect not only the saturation of the ratcheting strain but the ratcheting strain rate. A series of multi-step bending ratcheting experiments were conducted under both control modes. It was found that the hardening effect of Z2CND18.12N stainless steel pipe under previous cyclic loadings no matter with high or low displacement amplitudes is significant, and the prior loading histories greatly retard the ratcheting strain and its rate under subsequent loadings. Finally, the ratcheting boundaries of the pressurized straight Z2CND18.12N stainless steel pipe were determined and compared based on KTA/ASME, RCC-MR and the experimental results.

Heat Dissipation of Sealed LED Light Fixtures Using Pulsating Heat Pipe Technology

  • Kim, Hyung-Tak;Park, Hae-Kyun;Bang, Kwang-Hyun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.1
    • /
    • pp.64-71
    • /
    • 2012
  • An efficient cooling system is an essential part of the electronic packaging such as a high-luminance LED lighting. A special technology, Pulsating Heat Pipe (PHP), can be applied to improve cooling of a sealed, explosion-proof LED light fixture. In this paper, the characteristics of the pulsating heat pipes in the imposed thermal boundary conditions of LED lightings were experimentally investigated and a PHP device that works free of alignment angle was investigated for cooling of explosion-proof LED lights. Five working fluids of ethanol, FC-72, R-123, water, and acetone were chosen for comparison. The experimental pulsating heat pipe was made of copper tubes of internal diameter of 2.1 mm, 26 turns. A variable heat source of electric heater and an array of cooling fins were attached to the pulsating heat pipe. For the alignment of the heating part at bottom, an optimum charging ratio (liquid fluid volume to total volume) was about 50% for most of the fluids and water showed the highest heat transfer performance. For the alignment of the heating part on top, however, only R-123 worked in an un-looped construction. This unique advantage of R-123 is attributed to its high vapor pressure gradient. Applying these findings, a cooling device for an explosion-proof type of LED light rated 30 W was constructed and tested successfully.