• Title/Summary/Keyword: High pressure experiments

Search Result 898, Processing Time 0.026 seconds

Large-Scale Experiments on the Wave-Induced Liquefaction of Sandbed (파랑작용에 의한 모래지반의 액상화에 관한 대형 수리모형실험)

  • Kang, Yoon-Koo;Suzuki, Kojiro
    • Journal of Ocean Engineering and Technology
    • /
    • v.21 no.3 s.76
    • /
    • pp.26-32
    • /
    • 2007
  • A series of large-scale experiments were carried out in order to examine wave-induced liquefaction in a loosely packed sandbed, its afterward high densification and liquefaction by oscillatory pore pressure. The experiments were conducted in a Large Hydro-Geo Flume that can nearly solve the problems of scale effects of the sandbed, and the 50% sieve diameter of sand was 0.2 mm. The generation of residual pore pressure and its afterward high densification which had observed by Takahashi et al. (1999) in a wave flume experiment using fine sand with the size of 0.08 mm. As a result, the relative density of the sandbed after high densification was increased up to 79% and liquefaction by oscillatory pore pressure was not observed.

Effect of Glass Fiber Contents on the Tensile Strength in Injection Molding Process (사출성형공정에서 유리섬유함유량이 인장강도에 미치는 영향)

  • 김영수;김인관
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.5
    • /
    • pp.63-69
    • /
    • 2000
  • The main target of this research is investigating the relations between mechanical properties and injection conditions, like injection pressure, packing pressure and packing time for various contents ratio of glass fiber and resin. In general idea, high injection pressure produces high strength of molded parts as a monotonic function. but it was revealed that high pressure does not make high strength directly through various experiments of injection molding. In this experiments, PA66 was selected as resin and Glass Fiber was selected as reinforcing fiber Fiber reinforcement was controlled, as 14%, 25%, 33%, 44% of total volume and packing pressure was divided 55%, 65%, 75%, 85% of reference pressure, i.e. 100% equal to 1400kgf/$\textrm{cm}^2$. Finally, tensile testing was executed for injected test specimen. Optimum results based on authors' experiments have been obtained under conditions of 25% and 33% of glass fiber contents. Tensile strength rather depends on the packing pressure and packing time than injection pressure. Especially almost equal value of tensile strength was obtained for various percentage of packing and injection pressure as 65%, 75% and 85% of reference pressure.

  • PDF

A STUDY OF THE PRESSURE SOLUTION AND DEFORMATION OF QUARTZ CRYSTALS AT HIGH pH AND UNDER HIGH STRESS

  • Choi, Jung-Hae;Seo, Yong-Seok;Chae, Byung-Gon
    • Nuclear Engineering and Technology
    • /
    • v.45 no.1
    • /
    • pp.53-60
    • /
    • 2013
  • Bentonite is generally used as a buffer material in high-level radioactive waste disposal facilities and consists of 50% quartz by weight. Quartz strongly affects the behavior of bentonite over very long periods. For this reason, quartz dissolution experiment was performed under high-pressure and high-alkalinity conditions based on the conditions found in a high-level radioactive waste disposal facility located deep underground. In this study, two quartz dissolution experiments were conducted on 1) quartz beads under low-pressure and high-alkalinity conditions and 2) a single quartz crystal under high-pressure and high-alkalinity conditions. Following the experiments, a confocal laser scanning microscope (CLSM) was used to observe the surfaces of experimental samples. Numerical analyses using the finite element method (FEM) were also performed to quantify the deformation of contact area. Quartz dissolution was observed in both experiments. This deformation was due to a concentrated compressive stress field, as indicated by the quartz deformation of the contact area through the FEM analysis. According to the numerical results, a high compressive stress field acted upon the neighboring contact area, which showed a rapid dissolution rate compared to other areas of the sample.

Field Experiments on Performance Evaluation of Pressure Differential System for Smoke Management (급기가압 제연시스템의 현장 성능평가 연구)

  • Kim, Jung-Yup;Rie, Dong-Ho;Kim, Ha-Young
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.251-254
    • /
    • 2008
  • The fact that the major cases of life casualties are from smoke in the fire accidents and the expected steep increase of skyscrapers, huge spaces, multiplexes and huge scaled underground spaces demand establishment of efficient smoke countermeasure. The field experiments on two high buildings of 20 stories and 21 stories are carried out to evaluate the field performance of pressure differential systems for smoke management and the results of experiments are presented.

  • PDF

Numerical Analysis for Characteristics of Coaxial Swirl Injector in High-Pressure Environment (고압환경에서 동축 스월 분사기 분무 특성에 대한 수치적 해석)

  • Moon, Yoon-Wan;Seol, Woo-Seok;Kim, Dong-Jun;Yoon, Young-Bin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.131-134
    • /
    • 2007
  • This numerical analysis was performed in order to validate adoption of the sheet breakup model in high-pressure environment, which were used for prediction of spray characteristics in atmosphere environment. In experiments the higher environment pressure the shorter breakup length; the results of new sheet breakup model predicted the breakup length in good agreement with experimental results qualitatively and quantitatively. Also the shape of spray calculated by numerical analysis were agreed well with experiments quantitatively.

  • PDF

Method for Measuring pH and Alkalinity of High-Pressure Fluid Samples : Evaluation through Artificial Samples (고압 유체 시료의 pH 및 알칼리도 측정 방법 : 가상 시료를 활용한 실용성 평가)

  • Minseok Song;Soohyeon, Moon;Gitak Chae;Jun-Hwan Bang
    • Journal of Soil and Groundwater Environment
    • /
    • v.29 no.1
    • /
    • pp.1-9
    • /
    • 2024
  • As part of monitoring technology aimed at verifying the stability of CO2 geologic storage and mitigating concerns about leakage, a method for measuring the pH and alkalinity of high-pressure fluid samples was established to obtain practical technology. pH measurement for high-pressure samples utilized a high-pressure pH electrode, and alkalinity was measured using the Gran titration method for samples collected with a piston cylinder sampler (PCS). Experimental samples, referencing CO2-rich water and CO2 geologic storage studies, were prepared in the laboratory. The PCS controls the piston, preventing CO2 degassing and maintaining fluid pressure, allowing mixing with KOH to fix dissolved CO2. Results showed a 6.1% average error in high-pressure pH measurement. PCS use for sample collection maintained pressure, preventing CO2 degassing. However, PCS-collected sample alkalinity measurements had larger errors than non-PCS measurements, limiting PCS practicality in monitoring field settings. Nevertheless, PCS could find utility in preprocessing for carbon isotope analysis and other applications. This research not only contributes to the field of CCS monitoring but also suggests potential applications in studies related to natural analogs of CCS, CO2-rock interaction experiments, core flooding experiments, and beyond.

The Effect of High Pressure Chamber's Shape on the Characteristics of Annular Jet Pump (고압실 형상에 따른 환형 제트펌프의 특성)

  • 권오붕
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.35 no.4
    • /
    • pp.428-434
    • /
    • 1999
  • Experimental studies on the characteristics of annular jet pump were carried out in this paper. Jet pump can be used widely for the transportation of solid materials, farm produce and fishes. The effects of high pressure chamber on the characteristics of annular jet pump were sought in this paper. Experiments were done for three shapes of high pressure chamber, and for several lengths of the high pressure chamber. Three types of the high pressure chamber's entrances($90^{\circ}$ single inflow, $45^{\circ}$single inflow, and $45^{\circ}$ double inflow) were tested. Water was used for both the primary fluid and secondary fluid. The results obtained in this study are as follows; $45^{\circ}$double inflow type is the most effective among the tested three types of the high pressure chamber's entrances. The efficiency of jet pump with 400mm of high pressure chamber length is the highest among the chamber lengths tested in this study, thus indicating appropriate chamber length is required to get an efficient.

  • PDF

The Effect of High Pressure Chamber's Shape on the Characteristics of Annular Jet Pump (고압실 형상에 따른 환형 제트펌프의 특성)

  • Kim, Myung Gwan;Kwon, Oh Boong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.75-81
    • /
    • 2000
  • Experimental studies on the characteristics of annular jet pump were carried out in this paper. The effects of high pressure chamber on the characteristics of annular jet pump were sought in this paper. Experiments were done for three shapes of high pressure chamber, and for several lengths of the high pressure chamber. Three types of the high pressure chamber's entrances($90^{\circ}$ single inflow, $45^{\circ}$ single inflow, and $45^{\circ}$ double inflow) were tested. Water was used for both the primary fluid and secondary fluid. The results obtained in this study are as follows; $45^{\circ}$ double inflow type is the most effective among the tested three types of the high pressure chamber's entrances. The efficiency of jet pump with 400mm of high pressure chamber length is the highest among the chamber lengths tested in this study, thus indicating appropriate chamber length is required to get an efficient jet pump.

  • PDF

Experiments on Condensation Heat Transfer Characteristics and Flow Regime Inside Microfin Tubes (마이크로핀관내 유동 양식과 응축 열전달 특성 연구)

  • 한동혁;이규정
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.7
    • /
    • pp.602-611
    • /
    • 2001
  • Experiments on the condensation heat transfer characteristics inside a smooth and a microfin tube with R410A/R22 are performed in this study. The test tubes 7/9.52 mm in outside diameters and 3m in length are used. Varying the mass flux of the refrigerant and the condensation temperatures, the average heat transfer coefficients and pressure drop are investigated. Most flows in this study are in the annular and/or wavy flow regime. It is shown that the heat transfer is enhanced and the pressure drops are larger in the microfin tube than the smooth tube. From the heat transfer enhancement coefficients and the pressure drops, it is found that the high heat transfer enhancement factors are obtained in the range of small mass flux while the penalty factors are almost equal. Experiments results show that average heat transfer coefficients of R410A is larger than that of R22 and pressure drop of R410A is less than R22.

  • PDF

Analysis on the Blood F1ow, Pressure and Pulsatility of a Dual Pulsatile Extracorporeal Life Support (이중 박동형 생명구조장치의 혈류, 혈압, 박동성의 분석)

  • Choi, Seong-Wook;Min, Byoung-Goo
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.5
    • /
    • pp.684-693
    • /
    • 2007
  • Previous trials for development of a pulsatile-Extracorporeal Life Support had some defects such as insufficient blood flow, high pressure at its membrane oxygenator and the high risk of blood cell damage. To solve those problems of previous pulsatile-ECLSs, we suggest dual pulsatile blood pump structure for the new pulsatile-ECLS. Two pulsatile pumps areconnected in a parallel manner and this new structure raises the inflow capacity and efficiency and it decreases the high blood pressure at membrane oxygenator. In in-vitro experiments, The Energy Equivalent Pressure Increment(EEP inc.) was 10%, and it showed that its pulsatilty was $5{\sim}10$ times higher than other commercial ECLS In in-vivo experiments, we had applied a new pulsatile-ECLS to 30 Kg pigs and a new pulsatile-ECLS couldsupport high blood flow and pulsatility above 2 L/min, 10% EEP inc.