• 제목/요약/키워드: High performance simulation

검색결과 4,658건 처리시간 0.035초

링 블로어 내부유동장 및 성능특성 연구 (Performance and Internal Flow Analysis on Ring Blower)

  • 장춘만;한기영
    • 한국유체기계학회 논문집
    • /
    • 제11권4호
    • /
    • pp.38-44
    • /
    • 2008
  • This paper describes the performance and internal flow characteristics of two-stage high pressure ring blower. Chamber-type test rig is designed and manufactured for the performance test of the ring blower. Detailed flow characteristics inside the impeller and casing are analyzed by three-dimensional numerical simulation. Throughout numerical simulation, non-uniform inflow to the impeller inlet and reverse flow are observed near the inlet duct of the blower. This non-uniform inflow makes various recirculation flow inside the casing with the complicated shape of casing. Low velocity region is locally formed near the both sides of impeller outlet due to the non-uniform inflow to the impeller, thus deteriorates the performance of a ring blower.

혼합흐름 사이클용 흡수식 냉온수기의 성능특성 (Performance Characteristics on the Mixed Flow Type Absorption Chiller-Heater)

  • 윤정인;신기부;박석호
    • 설비공학논문집
    • /
    • 제8권3호
    • /
    • pp.351-360
    • /
    • 1996
  • This study focuses on the development and evaluation of the high efficiency absorption chiller-heater, which can be applied to a direct gas fired, double effect system with 40RT (508,000kJ) cooling capacity. The performance of the absorption chiller-heater is investigated through cycle simulation and experiment to obtain the system characteristics with the inlet tenperature of cooling, chilled water, and gas input flow rate. The efficiency of the different cycles has been studied and the simulation and experiment results show that higher coefficient of performance could be obtained for mixed flow cycle. The five percent difference was obtained from the comparison between experimental and cycle simulation results. As a result of this study, the optimum designs were determined based on the operating conditions and the coefficient of performance.

  • PDF

BIM기반의 건축시공시뮬레이션 시스템 성능분석 방법 및 사례연구 (Performance Measurement Method and Case Study for BIM based Construction Simulation System)

  • 전기현;윤석헌
    • 한국건설관리학회논문집
    • /
    • 제14권4호
    • /
    • pp.15-23
    • /
    • 2013
  • 건설프로젝트는 현장여건의 변화와 불확실성으로 신뢰성 높은 계획을 수립하기 힘들고 따라서 건축시공시뮬레이션 시스템의 도입으로 그러한 문제점을 해결하고 신뢰성 높은 계획을 수립하려는 노력을 보이고 있다. 그러나 현시점의 시뮬레이션 시스템은 단순 애니메이션 용도로만 사용되고 실제 엔지니어링 업무를 지원하는 경우도 드물다. 최근 들어 이러한 한계점을 탈피하고 보다 시뮬레이션 시스템을 보다 적극적으로 사용하기 위한 연구와 개발이 이루어지고 있다. 하지만 BIM의 가장 핵심이 업무 효율성이라는 점에서 이러한 BIM기반 건축시공시뮬레이션시스템 등의 BIM기반 시스템은 성능 분석이 매우 필요한 요소라고 판단된다. 본 연구에서는 이를 위하여 시뮬레이션의 핵심 업무 프로세스를 정의하고 표준 시나리오를 정의하여 이를 기준으로 성능을 분석하는 방법론을 제시함으로써 좀 더 효율적이고 적극성을 갖춘 시뮬레이션 시스템 개발을 가능하게 하고자 한다.

AirSim을 이용한 화력발전소 고온 환경의 보일러 내부 점검용 드론 개발 및 검증을 위한 시뮬레이션 (Simulation for Development and Validation of Drone for Inspection Inside Boilers in High Temperature Thermal Power Plants Using AirSim)

  • 박상규;정진석;시하영;강범수
    • 한국항공우주학회지
    • /
    • 제49권1호
    • /
    • pp.53-61
    • /
    • 2021
  • 본 논문은 고온 환경의 화력발전소 보일러 내부 점검용 드론 개발을 위한 선행연구로 AirSim을 이용한 고온 환경에서의 시뮬레이션을 통해 드론이 정상적인 비행이 가능한지 검증 하였다. 고온의 비행 환경에서는 공기 밀도, 점성계수 등이 상온과 달라 공력특성이 달라지며 이에 따라 드론의 비행성능 또한 달라진다. 따라서 온도 변화에 따른 프로펠러의 공력 특성의 변화를 확인하기 위해 JBLADE를 통한 프로펠러 해석과 추력 테스트, 전기추진계통 성능예측모델을 통한 동작특성예측을 수행하였다. 그리고 해석 및 성능예측 결과를 AirSim에 적용해 시뮬레이션을 진행하고 결과 분석을 통해 기체 재설계를 진행하였다. 재설계 결과 80℃의 환경에서 호버링 시 필요한 추력을 얻기 위해 재설계 전 최대 출력의 약 65% 사용하던 것이 52%로 감소함을 확인하였다.

On the Performance of Oracle Grid Engine Queuing System for Computing Intensive Applications

  • Kolici, Vladi;Herrero, Albert;Xhafa, Fatos
    • Journal of Information Processing Systems
    • /
    • 제10권4호
    • /
    • pp.491-502
    • /
    • 2014
  • In this paper we present some research results on computing intensive applications using modern high performance architectures and from the perspective of high computational needs. Computing intensive applications are an important family of applications in distributed computing domain. They have been object of study using different distributed computing paradigms and infrastructures. Such applications distinguish for their demanding needs for CPU computing, independently of the amount of data associated with the problem instance. Among computing intensive applications, there are applications based on simulations, aiming to maximize system resources for processing large computations for simulation. In this research work, we consider an application that simulates scheduling and resource allocation in a Grid computing system using Genetic Algorithms. In such application, a rather large number of simulations is needed to extract meaningful statistical results about the behavior of the simulation results. We study the performance of Oracle Grid Engine for such application running in a Cluster of high computing capacities. Several scenarios were generated to measure the response time and queuing time under different workloads and number of nodes in the cluster.

스프트 스위칭 보조 스위치를 가지는 ZVT-PWM 부스트 컨버터 (A High Performance ZVT-PWM Boost Rectifier with Soft Switched Auxiliary Switch)

  • 김윤호;김윤복;정재웅
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.265-268
    • /
    • 1998
  • This paper presents a soft-switching average current control PWM high power factor boost converter. Conventional boost ZVT-PWM converter has a disadvantage of hard-switching for auxiliary switch at turn-off. A soft switched auxiliary switch is proposed to achieve a high performance ZVT-PWM boost rectifier. The simulation and experimental results show that soft switching operation can be maintained for wide line and load range, which in turn improves the converter performance in terms of efficiency, switching noise and circuit reliability.

  • PDF

Development of Full Coverage Test Framework for NVMe Based Storage

  • Park, Jung Kyu;Kim, Jaeho
    • 한국컴퓨터정보학회논문지
    • /
    • 제22권4호
    • /
    • pp.17-24
    • /
    • 2017
  • In this paper, we propose an efficient dynamic workload balancing strategy which improves the performance of high-performance computing system. The key idea of this dynamic workload balancing strategy is to minimize execution time of each job and to maximize the system throughput by effectively using system resource such as CPU, memory. Also, this strategy dynamically allocates job by considering demanded memory size of executing job and workload status of each node. If an overload node occurs due to allocated job, the proposed scheme migrates job, executing in overload nodes, to another free nodes and reduces the waiting time and execution time of job by balancing workload of each node. Through simulation, we show that the proposed dynamic workload balancing strategy based on CPU, memory improves the performance of high-performance computing system compared to previous strategies.

The Performance Simulation of OFDM System Employing Hierarchical 16QAM for Image and Data Transmission in Multipath Fading Channel

  • Kwak, Jae-Min;Ahn, Jun-Bae;Park, Ki-Sik;Cho, Sung-Eon;Cho, Sung-Joon
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2000년도 종합학술발표회 논문집 Vol.10 No.1
    • /
    • pp.12-15
    • /
    • 2000
  • In this paper, we have evaluated the performance of an OFDM system using hierarchical 16QAM (OFDM/HL-16QAM) for achieving high quality and high speed data and image transmission in multipath fading channel. The wireless channel for performance evaluation is assumed to include AWGN and two ray multipath fading. Through simulation we have obtained the BER performance of the system according to $E_{b}$, $N_{0}$, then compared the received image quality of proposed system with that of conventional system. From the result, it is shown that the OFDM/HL-16QAM system is more effective for data and image transmission.n.n.

  • PDF

비공비 혼합 냉매를 이용한 2단 이코노마이져 시스템 개발 (Development of 2-Stage Economizer System Using the Non-Azeotropic Mixtures.)

  • 염한길;김욱중;이성진;홍용주
    • 연구논문집
    • /
    • 통권25호
    • /
    • pp.77-90
    • /
    • 1995
  • For improving performance of heat pump system, researcher has adapted 2-stage economizer cycle and developed a high-efficiency screw compressor, new working medium(non-azeotropic mixed refrigerant) and counterflow heat exchangers operating with a small temperature difference. Target of this study is development of high performance heat pump system with the 2-stage economizer system using the non-azeotropic mixed refrigerant. For the purpose of excuting target, we constucted computer simulation programs, compared and examed various types of cycle and non-azeotropic mixture. Based on the results from computer simulation we selected optimum mixtures and reflected design and production process of performance test equipment with the 1-stage econmizer system. In order to accomplish the final target, design and production of the 2-stage economizer system, we performed pilot test using the 1-stage economizer performance test system and finally design and production of the 2-stage economizer system.

  • PDF

3차원 전열해석 및 생애비용 분석을 통한 커튼월 앵커링 유닛의 단열성능 향상 방안 평가 (Insulation Performance Evaluation of the Curtain Wall Anchoring Unit by 3D Heat Transfer Simulation and Life Cycle Cost Analysis)

  • 강승희;송승영
    • 한국태양에너지학회 논문집
    • /
    • 제23권4호
    • /
    • pp.63-70
    • /
    • 2003
  • It is very important to improve the insulation performance of curtain wall anchoring unit since it is composed of materials with high thermal conductivity, such as aluminium, steel and so on. This study aims to evaluate the heating energy performance and economical efficiency of various alternatives which are different in position and material of insulation. As results, alternative of inserting the urethane washer & pad and coating the anchoring unit with urethane foam can improve the heating energy performance and L.C.C(Life Cycle Cost) by 6.33% and 0.95%, respectively, as compared with the existing case.